{"product_id":"nfdv551-p60-yokogawa-digital-output-module-new-original-stock","title":"NFDV551-P60 Yokogawa Digital Output Module | New \u0026 Original Stock","description":"\u003ch2\u003eYokogawa NFDV551-P60 STARDOM\/CENTUM VP Series Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFDV551-P60\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFDV551\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for driving solid-state field loads within STARDOM and CENTUM VP industrial automation networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model\u003c\/strong\u003e: NFDV551 (Digital Output Module, 32 Channels)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-P\u003c\/strong\u003e: Standard type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6\u003c\/strong\u003e: With status display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Basic type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption \/D5S10\u003c\/strong\u003e: Terminal block with surge absorber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFDV551-P60\/D5S10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 x 60 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 - 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent-sink transistor output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel @ 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeak Current (OFF)\u003c\/td\u003e\n\u003ctd\u003e0.1 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e3 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC for 1 minute (Output to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes optocouplers to establish rigid galvanic separation between the internal backplane logic and external field wiring. This loop topology integrates channel-to-channel group isolation rated at 500 VAC between individual 16-channel common paths. The integrated \/D5S10 terminal configuration provides transient surge absorption directly across the 24 VDC line loops to prevent back-EMF spikes from inductive actuators from degrading the switching transistors. Furthermore, the unit features configurable fallback safety states, allowing the output logic to execute explicit HOLD or FORCE OFF operations when backplane communication faults are detected.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical limitations govern the hot-swap capability of this module?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping must be executed only when the backplane is in a stable state and the specific field-side common terminal block is isolated from active 24 VDC power lines to prevent terminal arcing.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle inductive load configurations without damaging the internal circuits?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on the integrated \/D5S10 surge absorber terminal matrix to suppress voltage spikes. If driving high-current external relays, external flywheel diodes must be wired in parallel across the load.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum allowable backplane current draw for the logic circuitry?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum of 700 mA from the 5 VDC system backplane logic power supply rail.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting Stability\u003c\/strong\u003e: Snapping the module onto the 35 mm DIN-rail requires verification of the rear locking clip engagement. Ensure the module is seated perpendicular to the rail to prevent stress on the backplane connector pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Terminations\u003c\/strong\u003e: Connect all field cable shields to a single, dedicated low-impedance instrument ground bus. Do not loop ground wires or connect shields at both ends to prevent the formation of ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separations\u003c\/strong\u003e: Route the 24 VDC discrete output lines in separate wire ducts away from high-voltage AC power lines and variable frequency drive (VFD) motor cables to suppress cross-talk and electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screw Torque\u003c\/strong\u003e: Tighten all pressure-clamp terminal block screws to the manufacturer-specified torque limits to ensure gas-tight electrical contact and prevent loose connections under high-vibration conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43509447262298,"sku":"NFDV551-P60","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/183.1_9f0bccd5-45a9-4c80-92ee-5b22e5e9a655.jpg?v=1781661387","url":"https:\/\/www.spareoil.com\/ar\/products\/nfdv551-p60-yokogawa-digital-output-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}