{"product_id":"schneider-electric-140ddo35310-modicon-quantum-dc-discrete-output-module","title":"Schneider Electric 140DDO35310 Modicon Quantum DC Discrete Output Module","description":"\u003ch2\u003eSchneider Electric 140DDO35310 Modicon Quantum DC Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density digital output control in Modicon Quantum automation platform networks, the \u003cstrong\u003eSchneider Electric 140DDO35310\u003c\/strong\u003e (\u003cstrong\u003e140DDO35310\u003c\/strong\u003e DC Discrete Output Module) provides direct physical\/electrical execution. The module commands 32 solid-state discrete channels structured into 4 isolated groups of 8 channels each, operating under negative logic (sink) configurations. This hardware component translates internal backplane logic states into external 24 VDC switching actions, requiring 2 output words of register addressing from the master controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140DDO35310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (0.99 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 x 31.2 x 16.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e330 mA bus current requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (19.2 to 30 VDC limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel (4 A per group, 16 A total per module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms DC channel-to-bus for 1 minute; 500 Vrms DC group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms (state 0 to 1 and state 1 to 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.4 mA at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.0 W + (0.4 V x total load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Indicators\u003c\/td\u003e\n\u003ctd\u003e1 Active LED (green), 1 Fault LED (red), 32 Status LEDs (green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Protection Matrix\u003c\/h3\u003e\n\u003cp\u003eThe hardware integrates directly with the standard Quantum rack to maintain stable backplane bus communication velocity under varying load configurations. Internal protection circuits feature an integrated 5 A fuse per channel group to handle short circuits and protect the internal solid-state components. The module detects physical faults, lighting the red external fault LED (F) when it identifies a loss of field power or a blown fuse condition. This diagnostic data transfers to the processor within the standard backplane scan cycle.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What happens to the output channels if field power drops below the minimum operating threshold?\u003c\/p\u003e\n\u003cp\u003eA: When external field power falls outside the 19.2 to 30 VDC range, the hardware senses a loss of field power condition, triggers the front red Fault LED, and reports the error state to the controller while forcing the affected output group into a de-energized state.\u003c\/p\u003e\n\u003cp\u003eQ: Does this module support hot-swap replacement within an active Quantum rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Quantum platform mechanical design permits the module to be removed and inserted under power. However, the field wiring connector block must be detached first to isolate field currents and prevent transient voltage damage to the backplane interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module into the designated slot of the standard Quantum backplane and press firmly until the rear ground clips and bus connectors seat securely.\u003c\/li\u003e\n\u003cli\u003eVerify that each external group is protected by an external 3 A fuse per point or 5 A fuse per group to prevent overcurrent damage from high inductive fields.\u003c\/li\u003e\n\u003cli\u003eRoute the 24 VDC field output wiring separate from low-voltage analog signal cables and high-voltage AC mains inside the wire ducts to prevent inductive coupling and signal corruption.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43536774266970,"sku":"140DDO35310","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/215_2975670c-1300-4baf-a2b6-2b96f1a1a30c.jpg?v=1782180979","url":"https:\/\/www.spareoil.com\/ar\/products\/schneider-electric-140ddo35310-modicon-quantum-dc-discrete-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}