{"product_id":"schneider-modicon-tsx-micro-tsxdsz08r5-digital-output-modules","title":"Schneider Electric TSXDSZ08R5 Modicon TSX Micro Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric TSXDSZ08R5 is a dedicated relay output module engineered for the Modicon TSX Micro programmable logic controller series. This module provides 8 independent, normally open (NO) relay outputs, enabling the PLC to interface directly with high-voltage field devices, including AC motors, contactors, and solenoid valves. By utilizing mechanical relay contacts, the unit ensures robust galvanic isolation between the low-voltage controller logic and high-power field circuits, protecting sensitive CPU components from electrical transients and voltage spikes common in industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight independent relay output channels for versatile load control.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between field contacts and the internal system backplane.\u003c\/li\u003e\n\u003cli\u003eIntegrated RC snubber circuitry to suppress inductive spikes during reactive load switching.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators providing real-time status monitoring for each output channel.\u003c\/li\u003e\n\u003cli\u003eRemovable screw terminal blocks for simplified field wiring and rapid maintenance.\u003c\/li\u003e\n\u003cli\u003eCompact form factor designed for integration into standard TSX Micro racks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe TSXDSZ08R5 is widely utilized in industrial automation, particularly in sectors requiring high-voltage switching flexibility. Common applications include boiler control systems, fluid management and pumping stations, HVAC control, and general discrete manufacturing processes where physical isolation of control signals is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDSZ08R5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e8 x Normally Open (NO) Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e24 to 240 VAC \/ 24 to 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current (per channel)\u003c\/td\u003e\n\u003ctd\u003e2.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current\u003c\/td\u003e\n\u003ctd\u003e10.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Switching Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA at 5 VDC \/ 60 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC (contacts to logic bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack power is disconnected before installing or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the module securely into the designated TSX Micro slot and ensure the backplane connector is fully seated.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded cabling for field wiring where high-EMI sources are present to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that total load current does not exceed the 10.0 A module limit to prevent relay contact degradation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the control cabinet to ensure ambient temperatures remain within the 0 to 60 deg C operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the TSXDSZ08R5?\u003c\/strong\u003e\u003cbr\u003eThis module acts as an output interface for the TSX Micro PLC, allowing it to switch AC or DC power loads up to 240 VAC through its 8 onboard mechanical relays.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the relays?\u003c\/strong\u003e\u003cbr\u003eThe module draws its control power from the internal PLC bus, while the field-side load power is provided by the external circuit connected to the screw terminals.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAre the outputs isolated?\u003c\/strong\u003e\u003cbr\u003eYes, the module provides galvanic isolation between the outputs and the internal logic bus to protect the controller from field-side electrical faults.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":44052623130714,"sku":"TSXDSZ08R5","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_23b3a2ae-9e11-4787-9dde-52bb7f5c9453.jpg?v=1789192039","url":"https:\/\/www.spareoil.com\/ar\/products\/schneider-modicon-tsx-micro-tsxdsz08r5-digital-output-modules","provider":"SpareOil Automation","version":"1.0","type":"link"}