{"product_id":"t8193-ics-triplex-trusted-tmr-digital-input-module","title":"T8193 ICS Triplex Trusted TMR Digital Input Module","description":"\u003ch2\u003eICS Triplex T8193 TMR Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-integrity digital signal acquisition in Trusted safety systems, the \u003cstrong\u003eICS Triplex T8193\u003c\/strong\u003e (\u003cstrong\u003eT8193\u003c\/strong\u003e TMR Digital Input Module) provides direct physical signal processing via a 32-channel interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142 x 92 x 54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e3000 VAC channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Reliability Safety Execution\u003c\/h3\u003e\n\u003cp\u003eThe T8193 utilizes a triple modular redundancy (TMR) architecture to maintain continuous safety state execution. Each of the 32 input channels undergoes galvanic isolation, ensuring that electrical noise or ground loops from field devices do not compromise the processor backplane. The module executes internal diagnostics to detect open circuits, short circuits, and stuck-on or stuck-off conditions at a response time of 0.5 ms or less. This design ensures that the module complies with IEC 61508 SIL 3 requirements, facilitating fail-safe state execution in the event of an internal hardware fault or peripheral signal loss.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the T8193 support hot-swapping while the Trusted controller is in RUN mode?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is engineered for hot-swap operations. The backplane design allows for the insertion or removal of the module without interrupting the TMR voting logic of the remaining installed modules.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle fault detection for field-side dry contacts?\u003c\/p\u003e\n\u003cp\u003eA: The T8193 performs continuous voltage-sensing on each input loop. When configured for dry contacts, it monitors the loop current; deviations outside the defined 6–8 mA current signature trigger an immediate fault status report to the system controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the T8193 module firmly into the designated Trusted backplane slot. Ensure the locking mechanisms are fully engaged to maintain structural integrity and proper backplane bus contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted-pair cabling for all field signal inputs to mitigate induced electromagnetic interference. Terminate cable shields at the designated chassis grounding rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Confirm that the dual redundant 24 VDC power supplies are stable and within the 18–32 VDC operating range before energizing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e After installation, verify that the module health and channel status LEDs indicate normal operation via the system engineering workstation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":43569445306458,"sku":"T8193","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/84._8110305e-8a02-44ab-8160-17a1add1e0d6.jpg?v=1782714065","url":"https:\/\/www.spareoil.com\/ar\/products\/t8193-ics-triplex-trusted-tmr-digital-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}