{"product_id":"triconex-3604e-tricon-3000-series-digital-output-module","title":"Triconex 3604E Tricon 3000 Series Digital Output Module","description":"\u003ch2\u003eTRICONEX 3604E Tricon 3000 Series Digital Output Modules\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-reliability final control element actuation in Tricon 3000 Series SIS platforms, the \u003cstrong\u003eTRICONEX 3604E\u003c\/strong\u003e (\u003cstrong\u003e3604E\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. The module drives discrete field devices by executing safe state switching across triple modular redundant paths.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3604E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg net weight (5.00 kg shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e177.8 mm x 101.6 mm x 228.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete, non-commoned outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e22 to 45 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 4 V typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd\u003e2 A maximum per point (10 A surge for 10 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Leakage\u003c\/td\u003e\n\u003ctd\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Code\u003c\/td\u003e\n\u003ctd\u003eDark blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL3, IEC 61511, TÜV, UL Class I Div 2, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety Control (SIS) Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates a Triple Modular Redundancy (TMR) 2oo3 architecture featuring three internal, isolated logic legs executing parallel output algorithms. Quad voting circuitry on the output stage ensures that internal electronic component faults are automatically voted out, executing fail-safe state execution without interrupting process uptime or dropping the load. Individual channel galvanic isolation rated at 1500 VDC decouples the processing electronics from field loop interference and inductive voltage spikes. The module runs integrated diagnostic subroutines to verify the switching readiness of the output switches and to monitor field wiring paths for open loops or short circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module control the thermal energy generated during inductive load switching?\u003c\/p\u003e\n\u003cp\u003eA: The internal switching array routes the inductive kickback current through integrated clamp diodes. To maintain operational safety margins and prevent hardware degradation, external field termination bases require fast-acting 2.5 A fuses on each individual output to interrupt high-energy short circuits before they reach the main module frame.\u003c\/p\u003e\n\u003cp\u003eQ: What are the specific visual status indications when an internal leg fault occurs during runtime?\u003c\/p\u003e\n\u003cp\u003eA: When an internal diagnostic routine flags an error on one of the logic legs, the module front-panel FAIL LED activates while the ACTIVE light remains illuminated. The remaining two functional legs sustain the 2oo3 voting structure by operating in a degraded 1oo2 mode, transmitting full diagnostic parameters to the TriStation application without causing a spurious process trip.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing Infrastructure:\u003c\/strong\u003e Ensure every output point has a 2.5 A fast-acting fuse installed on the associated field termination baseplate to secure the module against field load overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Separation Rules:\u003c\/strong\u003e Enforce absolute separation between these 24 VDC discrete output control paths and low-voltage analog signal circuits within the panel wireways to eliminate transient switching EMI injection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Torque Limit:\u003c\/strong\u003e Tighten all field terminal wire connections to 0.5 Nm to prevent high-resistance contact arcs that can destabilize the discrete load circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":43724342100058,"sku":"3604E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/187._0f882889-8cd3-4448-b692-1462451d8002.jpg?v=1784864212","url":"https:\/\/www.spareoil.com\/ar\/products\/triconex-3604e-tricon-3000-series-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}