{"product_id":"yokogawa-adm51t-centum-cs-3000-contact-output-module","title":"Yokogawa ADM51T CENTUM CS 3000 Contact Output Module","description":"\u003ch2\u003eYokogawa ADM51T Contact Output Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADM51T\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADM51T\u003c\/strong\u003e Contact Output Module, operates as a dedicated hardware component for transistor switching and external load actuation within CENTUM CS 3000 and CENTUM VP platforms. The module drives external relays, solenoids, and indicator circuits across 32 discrete sink-type transistor output channels. Featuring 1500 Vrms dielectric isolation between channel terminals and system backplane logic, the hardware delivers rapid \u0026lt;= 1 ms response times for real-time control execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADM51T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 - 0.65 kg (1 lbs 0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e125 mm x 100 mm x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 W typical (400-600 mA @ 5 VDC backplane draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003eTransistor output (sink type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-10% (Maximum 30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel (0.6 A maximum per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 Vrms channel-to-backplane for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eYokogawa process control architectures incorporate strict galvanic isolation barriers to prevent field-side inductive spikes and voltage surges from propagating into central control buses. The ADM51T provides 1500 Vrms isolation between transistor output drivers and central system logic. When operating in control enclosures alongside 4-20 mA HART analog loops, this isolation barrier suppresses common-mode noise and prevents ground potential differences from causing signal degradation or system backplane resets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical load restrictions for individual output channels on the ADM51T? A: Each sink-type transistor channel operates nominally at 24 VDC +\/-10% with a standard load rating of 0.5 A, up to a maximum continuous threshold of 0.6 A at 30 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What front-panel diagnostic indications does the ADM51T hardware provide? A: The module front panel includes 1 green LED for system power verification and 32 red status LEDs displaying active state logic for each individual output channel.\u003c\/p\u003e\n\u003cp\u003eQ: How is field wiring terminated to the ADM51T module? A: External field cables connect via a removable 40-screw terminal block designed for wire sizes ranging from 0.2 mm2 to 2.5 mm2.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that cabinet power is off or that the destination rack slot is isolated prior to inserting the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module base keying features with the rack slot tracks and insert straight to avoid pin bending on the rear connector.\u003c\/li\u003e\n\u003cli\u003eTerminate external load wires onto the removable 40-pin terminal block using conductors sized between 0.2 mm2 and 2.5 mm2.\u003c\/li\u003e\n\u003cli\u003eRoute DC output cabling through dedicated cabinet raceways physically separated from high-voltage AC lines to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround all cable shields and enclosure ground points directly to the system grounding bar using short, low-impedance copper straps.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43787425218650,"sku":"ADM51T","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/728.1.jpg?v=1785900683","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-adm51t-centum-cs-3000-contact-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}