{"product_id":"yokogawa-adv551-p00-digital-output-module-32-channel","title":"Yokogawa ADV551-P00 Digital Output Module 32-Channel","description":"\u003ch2\u003eYokogawa ADV551-P00 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density signal distribution in CENTUM VP platforms, the \u003cstrong\u003eYokogawa ADV551-P00\u003c\/strong\u003e (\u003cstrong\u003eADV551-P00\u003c\/strong\u003e Digital Output Module) provides direct electrical execution of field device control and discrete state switching.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSuffix\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003ctd\u003eBase Model: 32-Channel, 24 VDC, Isolated Digital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith Pushbutton Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eWithout Status Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/D5S00\u003c\/td\u003e\n\u003ctd\u003eOption: Pressure Clamp Terminal Block (ATD5S-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P00\/D5S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e125 x 130 x 248 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eVia I\/O Base Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e32 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC Field to System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProcess Control and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eADV551-P00\u003c\/strong\u003e operates as a discrete command interface between the field control station and field-mounted actuators or relays. Yokogawa engineers incorporate channel-to-channel isolation within the module architecture to suppress electromagnetic interference and prevent ground loops. This isolation maintains signal integrity during high-density switching operations. Furthermore, the module filters transient voltages to protect the internal logic circuits from noise generated by inductive field loads. Because the unit includes a pressure clamp terminal block, operators ensure high-reliability mechanical connections in vibration-sensitive environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV551-P00 module support hot-swapping during normal system runtime? A: You may remove or insert the module while the system is powered, provided the I\/O rack supports hot-swapping configurations. However, you must command the module to a \"standby\" or \"test\" state via the engineering station to prevent unexpected field device activation during the transition.\u003c\/p\u003e\n\u003cp\u003eQ: How does the pushbutton input function on this module? A: The \"P\" suffix denotes integrated pushbutton input support. This feature allows operators to perform manual overrides or verification tests directly at the terminal level without requiring secondary logic processing from the main controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the ADV551-P00 firmly into the designated I\/O base slot. Secure the module using the integrated locking mechanism to guarantee consistent contact with the backplane communication pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the field actuators to the ATD5S-00 pressure clamp terminal block. You must ensure all wiring conforms to the cabinet's wire management specifications to prevent mechanical strain on the terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate the cable shields to the cabinet protective earth bar. Effective grounding prevents EMI from leaking into the output circuits, which ensures deterministic control of sensitive field actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e Perform a loop check after installation. Verify that the output state corresponds to the command signal issued from the DCS, ensuring the pushbutton inputs are correctly mapped within the system configuration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43627508793434,"sku":"ADV551-P00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/496._76dd6c5b-2857-4e4d-a8e5-570f513ec457.jpg?v=1783663765","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-adv551-p00-digital-output-module-32-channel","provider":"SpareOil Automation","version":"1.0","type":"link"}