{"product_id":"yokogawa-adv551-p60-d5a00-centum-vp-digital-output-module","title":"Yokogawa ADV551-P60\/D5A00 CENTUM VP Digital Output Module","description":"\u003ch2\u003eYokogawa ADV551-P60\/D5A00 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed signal actuation in CENTUM VP control system platforms, the \u003cstrong\u003eYokogawa ADV551-P60\/D5A00\u003c\/strong\u003e (\u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe suffix structure defines functional features and system termination hardware for the ADV551 base platform:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eP\u003c\/strong\u003e: Specifies integrated pulse width output and time-proportional output execution functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6\u003c\/strong\u003e: Indicates front status display functionality with standard non-explosion-proof housing construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Designates the standard base module layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD5A00\u003c\/strong\u003e: Incorporates the factory KS Cable Interface Adapter designed for 32-channel digital field connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P60\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance \/ Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e27.4 cm x 6.4 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA at 5 VDC, 60 mA at 24 VDC external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor output (sink\/source configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current\u003c\/td\u003e\n\u003ctd\u003eUp to 0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2000 VAC withstand (channel-to-channel and channel-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Loop Management\u003c\/h3\u003e\n\u003cp\u003eThe hardware incorporates optoelectronic isolation barriers rated for 2000 VAC withstand, preventing ground loops and transient noise propagation across system backplane buses. Engineered to operate in close proximity to sensitive 4-20 mA HART loop protocol wiring and analog instruments, each output channel isolates electrical transients generated during switching operations. Individual short-circuit and overload protection circuits prevent field faults from compromising adjacent channels, maintaining signal stability for high-density valve actuators and interlock relays.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support online extraction while the DCS chassis is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, operators can perform online hot-swap replacements without removing backplane power or disturbing adjacent active I\/O cards, provided standard field wiring removal steps are followed.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle overcurrent conditions on an active output channel?\u003c\/p\u003e\n\u003cp\u003eA: Each output circuit features short-circuit and thermal overload protection. When an overcurrent state occurs, the module isolates the fault to the affected line while adjacent channels remain operational.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAlign the module edge connector with the designated slot on the CENTUM VP rack and push firmly until the locking mechanisms engage fully. Connect the KS interface cable directly to the front terminal block adapter, ensuring all retention screws are hand-tightened. Connect signal shielding conductors to the single-point cabinet ground bus to mitigate ground potential loops. Route 24 VDC field actuator cables separately from low-voltage analog wiring inside the enclosure ducts to suppress cross-talk and electromagnetic interference.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859610533978,"sku":"ADV551-32DO","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/832..jpg?v=1787021113","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-adv551-p60-d5a00-centum-vp-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}