{"product_id":"yokogawa-adv561-p50-centum-vp-digital-output-module","title":"Yokogawa ADV561-P50 Centum VP Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV561-P50\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV561\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for pulse width and time-proportional output execution within Yokogawa Centum VP platforms. Configured for direct electrical driving of external industrial loads, the module processes logic command signals from the system processor into distinct physical field states across 64 isolated channels.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eADV561\u003c\/strong\u003e: Base module identifier for the 64-channel, 24 V DC isolated digital output architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-P\u003c\/strong\u003e: Specifies the integration of pulse width output function and time-proportional output function capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5\u003c\/strong\u003e: Validates the hardware configuration as having no status display and no integrated explosion protection ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Indicates the standard basic hardware type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV561-P50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 12.7 cm x 14.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e64 isolated digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (range: 20.4 to 26.4 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current (OFF)\u003c\/td\u003e\n\u003ctd\u003eMax 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eMax 3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7200 s (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (output to system), 500 V AC (between commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Grouping\u003c\/td\u003e\n\u003ctd\u003e4 commons (16 channels per common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe module implements 4-20 mA HART loop protocol emulation mechanics through its time-proportional output functionality, alongside robust channel-to-channel isolation matrices across the four distinct common groups. This electrical isolation framework shields the internal system backplane from field-side transients up to 2 kV AC. The continuous monitoring of leakage current during the OFF state (restricted to 0.1 mA) ensures high signal fidelity when interfacing with high-impedance interposing relays or field instrumentation indicators.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the specific power supply requirements for the field-side channels?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an external, regulated 24 V DC power supply operating within the 20.4 to 26.4 V DC threshold to power the 64 output channels, as the internal backplane 5 V DC bus only supplies logic-side power.\u003c\/p\u003e\n\u003cp\u003eQ: What occurs if the continuous current load on an individual channel exceeds 100 mA?\u003c\/p\u003e\n\u003cp\u003eA: Exceeding the 100 mA channel current rating will trigger internal thermal or overcurrent stress, leading to hardware degradation or permanent failure of the solid-state output switch component on that specific channel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal and Cable Connections:\u003c\/strong\u003e Utilize specialized AKB337 cables or approved MIL connector assemblies to interface with the high-density output termination blocks. All connections must be checked for proper pin alignment before applying external power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Ground Base:\u003c\/strong\u003e Connect all field cable shields to a single, dedicated instrumentation ground bar. Do not daisy-chain ground lines between separate modules to prevent the formation of ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Ensure unhindered physical clearance around the FIO rack slot structure to permit passive heat sink dissipation. Do not block the vertical ventilation pathways of the module chassis.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43517511434330,"sku":"ADV561-P50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/393_84df1378-5ab3-499e-9829-05dbc056005d.jpg?v=1781747718","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-adv561-p50-centum-vp-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}