{"product_id":"yokogawa-adv859-p00-centum-vp-cs-fio-digital-output-module","title":"Yokogawa ADV859-P00 CENTUM VP\/CS FIO Digital Output Module","description":"\u003ch2\u003eYokogawa ADV859-P00 FIO Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density transistor signal execution in CENTUM VP\/CS distributed control systems, the \u003cstrong\u003eYokogawa ADV859-P00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eYokogawa ADV859\u003c\/strong\u003e Digital Output Module, provides direct physical\/electrical execution. It operates as a dedicated hardware interface, driving up to 64 isolated field loads such as solenoids, relays, indicator alarms, and industrial actuators via low-side current sinking.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV859-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 119.9 x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~700 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e64 isolated digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (operational range: 20.4 to 26.4 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor output (current sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLower than or equal to 3 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeak Current (OFF)\u003c\/td\u003e\n\u003ctd\u003eLower than or equal to 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (signal-to-system, 1 min); 500 V AC between commons (per 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Modes\u003c\/td\u003e\n\u003ctd\u003eON\/OFF status output, pulse width output (8 ms to 7200 s), time-proportioning output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eMIL connector cable (AKB337)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eStandard coating (no G3 conformal coating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe hardware features a strict 4-20 mA HART loop protocol compatibility within the wider DCS environment, complemented by robust channel-to-channel isolation grouped per 16 channels. The galvanic isolation barrier rated at 2 kV AC prevents high-voltage transients on the field side from migrating back to the system backplane bus. The module utilizes high-speed transistor arrays configured as current sinks, ensuring clean, bounce-free switching logic. Internal circuitry accommodates precise time-proportioning execution and pulse width modulation directly at the hardware layer, mitigating CPU overhead during complex loop adjustments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV859-P00 support hot-swapping under live system conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports live online removal and insertion when installed within a compatible FIO node unit. However, field termination blocks or MIL cables must be disconnected or unpowered first to eliminate field-side short-circuit risks during extraction.\u003c\/p\u003e\n\u003cp\u003eQ: What are the electrical implications of the P00 suffix compared to other variants?\u003c\/p\u003e\n\u003cp\u003eA: The P00 suffix denotes the standard hardware version utilizing standard physical board coatings. It lacks the G3 ISA-S71.04 compliant conformal coating, meaning it is restricted to general-purpose environments free from elevated levels of corrosive gases like H2S or SO2.\u003c\/p\u003e\n\u003cp\u003eQ: How is the common return circuit wired for the 64 output channels?\u003c\/p\u003e\n\u003cp\u003eA: The 64 output channels are electrically segmented into four distinct isolated groups containing 16 channels each. Each group shares an independent common minus side return, allowing for different 24 VDC external power supply distributions if required.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure absolute compliance with the DIN-rail grounding guidelines by confirming the chassis rail connects directly to the system structural earth or protective earth bar with a low-impedance conductor.\u003c\/li\u003e\n\u003cli\u003eMaintain the mandatory physical clearance of at least 50 mm above and below the module housing to allow passive thermal dissipation and prevent internal component degradation within enclosed cabinets.\u003c\/li\u003e\n\u003cli\u003eThe external MIL connector cable (Model AKB337) must be routed through dedicated low-voltage DC cable trays, separate from high-voltage AC power distribution lines, to suppress electromagnetic induction.\u003c\/li\u003e\n\u003cli\u003eFor inductive field loads such as heavy solenoids or mechanical relays, external flywheel diodes must be wired in parallel at the load termination points to suppress destructive inductive back-EMF spikes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43778037514330,"sku":"ADV859-P00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/668_9127386e-4e2f-4e54-bc64-7efd4ccdea30.jpg?v=1785722980","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-adv859-p00-centum-vp-cs-fio-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}