{"product_id":"yokogawa-agp813-s10-centum-vp-dcs-high-speed-protection-module","title":"Yokogawa AGP813-S10 CENTUM VP DCS High-Speed Protection Module","description":"\u003ch2\u003eYokogawa AGP813-S10 CENTUM VP Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for motor starter protection and regulated power distribution in CENTUM VP systems, the \u003cstrong\u003eYokogawa AGP813-S10\u003c\/strong\u003e (\u003cstrong\u003eYokogawa AGP813\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. The hardware establishes galvanic isolation and regulated voltage transformation while managing specialized signal inputs to interface seamlessly with industrial distributed control infrastructure.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAGP813-S10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 28 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 75 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC \/ 200-240 V AC wide range (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC plus\/minus 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by loop load, efficiency greater than or equal to 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Channels\u003c\/td\u003e\n\u003ctd\u003e4 high-speed channels, 6 basic cycle channels (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Input Channels\u003c\/td\u003e\n\u003ctd\u003e4 basic cycle channels (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Pickup Inputs\u003c\/td\u003e\n\u003ctd\u003e0.5 to 150 Vpp, 50 Hz to 25 kHz frequency range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Pickup Inputs\u003c\/td\u003e\n\u003ctd\u003eTYPE1 and TYPE2 compliance, 0.04 Hz to 2 kHz frequency range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs (SOE)\u003c\/td\u003e\n\u003ctd\u003e4 high-speed channels, 8 basic cycle channels (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDistributed Control System Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe electronic design incorporates channel-to-channel isolation parameters to prevent electrical noise propagation across the field backplane structure. The input channels run parallel to the 4-20 mA HART loop protocol architectures, ensuring that transient high-speed signals or magnetic pickup frequencies do not distort analog loop values. Independent isolation barriers secure the input processing matrix, filtering industrial common-mode voltages and preventing grounding faults from damaging downstream processor electronics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal controller manage internal components when a transient overvoltage occurs?\u003c\/p\u003e\n\u003cp\u003eA: The architecture deploys independent hardware-level overcurrent, overvoltage, and short-circuit protection circuits that clamp internal rails without interrupting adjacent processing cards during redundant execution.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum latency for high-speed digital inputs mapping to the Sequence of Events (SOE) buffer?\u003c\/p\u003e\n\u003cp\u003eA: High-speed channels operate via dedicated internal interrupt vectors on a sub-millisecond hardware scanning clock cycle, ensuring precise event time-stamping before internal system communication cycles occur.\u003c\/p\u003e\n\u003cp\u003eQ: Can this unit execute hot-swap processes under active load conditions?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is fully supported only when the module is part of a dual redundant power supply configuration; removing a single non-redundant module will disrupt the 5 V DC bus potential.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRack Mount Execution: Insert the module into the designated slot of the CENTUM VP cabinet. Tighten the faceplate retention screws according to factory torque standards to ensure firm backplane connector mating.\u003c\/li\u003e\n\u003cli\u003eSignal Line Routing: Separate the high-speed pulse and magnetic pickup sensor cables from surrounding 240 V AC power distributions lines. Use shielded twisted-pair cables to mitigate high-frequency interference.\u003c\/li\u003e\n\u003cli\u003eFunctional Grounding: Connect the cabinet frame grounding wire directly to the room low-impedance earth bar. Ensure all cable shields tie back to a single designated instrumentation ground point to avoid circulating ground currents.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43767837163610,"sku":"AGP813-S10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/473._3d9857a1-7ec2-4b2e-a3e6-1d08f72bc576.jpg?v=1785465816","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-agp813-s10-centum-vp-dcs-high-speed-protection-module","provider":"SpareOil Automation","version":"1.0","type":"link"}