{"product_id":"yokogawa-aip502-centum-vp-v-net-coupler-communication-module","title":"YOKOGAWA AIP502 CENTUM VP V-Net Coupler Communication Module","description":"\u003ch2\u003eYOKOGAWA AIP502 V-Net Coupler Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed network integration in CENTUM VP\/CS distributed control systems, the \u003cstrong\u003eYOKOGAWA AIP502\u003c\/strong\u003e (\u003cstrong\u003eAIP502\u003c\/strong\u003e V-Net Coupler Module) provides direct physical execution of data exchange between field controllers and I\/O nodes across configurable star or bus network topologies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIP502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 mm x 120 mm x 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VAC\/VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 100 Mbps (Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eV-Net, Modbus, PROFIBUS-DP, DeviceNet, Ethernet\/IP, PROFINET IO, EtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Nodes\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AIP502 module functions as the primary communication bridge, facilitating low-latency transmission within Yokogawa process automation platforms. This unit utilizes advanced V-Net proprietary protocols alongside standard industrial communication interfaces to ensure deterministic data throughput. When implementing this module, users must verify that channel-to-channel isolation parameters align with the existing network segment architecture, effectively mitigating potential noise or ground interference inherent in multi-node industrial network deployments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the AIP502 support hot-swapping during active system communication?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is engineered with a hot-swappable design, allowing for replacement without interrupting the V-Net communication loop. Ensure the system is configured to handle the temporary node removal, and verify communication health status via the online diagnostic interface immediately after insertion.\u003c\/p\u003e\n\u003cp\u003eQ: How are communication diagnostics monitored during operation?\u003c\/p\u003e\n\u003cp\u003eA: The module performs continuous online health monitoring, providing real-time data on node status and communication errors. Status is reflected through the host DCS interface, allowing for proactive identification of bus faults or individual node failures before they impact process control loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module within the designated rack slot of the I\/O nest. Ensure the backplane interface is fully seated and the mechanical locking latches are engaged to prevent vibration-induced intermittent connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify the module chassis achieves a low-impedance connection to the rack ground. Shielded communication cabling must be terminated at the cabinet's designated grounding point to ensure effective EMI suppression at higher data rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain adequate spacing between the communication cabling and high-power AC lines to minimize inductive crosstalk. Use high-quality shielded twisted-pair cables for bus segments, ensuring that shield continuity is maintained across all network joints.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43616480657498,"sku":"AIP502","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/479_df61ae08-a1a5-43e8-b7b0-ac1331095ad6.jpg?v=1783480830","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-aip502-centum-vp-v-net-coupler-communication-module","provider":"SpareOil Automation","version":"1.0","type":"link"}