{"product_id":"yokogawa-akb331-m010-akb331-signal-cable-50-50-pins","title":"Yokogawa AKB331-M010 AKB331 Signal Cable 50-50 Pins","description":"\u003ch2\u003eYOKOGAWA AKB331-M010 Signal Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for Specific Technical Task in System\/Network Name, the \u003cstrong\u003eYOKOGAWA AKB331-M010\u003c\/strong\u003e (\u003cstrong\u003eAKB331\u003c\/strong\u003e Signal Cable (50-50 pins)) provides direct physical\/electrical execution. This passive hardware assembly establishes point-to-point electrical connectivity between discrete I\/O modules, safety modules, and dedicated field terminal boards within CENTUM VP, CENTUM CS 3000, and ProSafe-RS control architectures. The cable acts as the primary pathway for high-density multi-channel signal routing, securing low-impedance connection integrity without signal degradation across industrial control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAKB331-M010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eFactory length 10 m, 50-pin to 50-pin interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.0 W (Passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eMulti-core industrial signal cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003e50-pin to 50-pin MIL standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eSDV144, SDV531, SDV53A, SDV541, SAT145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding Structure\u003c\/td\u003e\n\u003ctd\u003eDual-layer (aluminum foil + copper braid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003eHigh-purity stranded copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Attributes\u003c\/h3\u003e\n\u003cp\u003eThe AKB331-M010 signal assembly incorporates dual-layer electromagnetic interference shielding designed to stabilize 4-20 mA HART loop protocol parameters when deployed alongside high-density distributed control system components. The structural geometry of the multi-core conductor maintains tight channel-to-channel isolation metrics, suppressing electrostatic crosstalk and inductive coupling between adjacent pairs. This physical barrier ensures that low-level analog inputs and micro-ampere safety signals maintain strict signal integrity throughout transmission. Furthermore, the low resistance profile of the stranded copper conductors prevents voltage drops across the 10 m span, preserving the measurement accuracy required by host modules performing cold junction compensation or process variable digitization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AKB331-M010 signal cable be altered or truncated in the field to match specific panel dimensions?\u003c\/p\u003e\n\u003cp\u003eA: No. The assembly is factory-terminated and sealed to maintain precise electrical characteristics. Field modification breaks the integrity of the dual-layer shielding and invalidates the safety certifications for high-density I\/O routing.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum voltage threshold allowed across the individual pin contacts of this cable?\u003c\/p\u003e\n\u003cp\u003eA: The insulation system and connector spacing are rated for a maximum operating voltage of 300 V. Exceeding this limit compromises the channel-to-channel isolation and risks dielectric breakdown between internal stranded cores.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eDuring deployment, installers must maintain the minimum bend radius constraints specified for multi-core shielded cables to prevent mechanical stress on the inner conductor strands. Route the cable through dedicated low-voltage wireways, ensuring absolute physical separation from high-current AC power lines or variable frequency drive outputs to avoid electromagnetic interference. Secure the 50-pin MIL connectors into the mating module receptacles until the mechanical locking mechanisms engagement is complete. The integrated dual-layer shield must connect directly to the system cabinet earth ground via the specified grounding bars, preventing ground loops while ensuring maximum electrostatic drain performance.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43767701438554,"sku":"AKB331","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/682..jpg?v=1785458978","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-akb331-m010-akb331-signal-cable-50-50-pins","provider":"SpareOil Automation","version":"1.0","type":"link"}