{"product_id":"yokogawa-akb337-m010-20-pin-shielded-signal-cable-assembly","title":"Yokogawa AKB337-M010 20-Pin Shielded Signal Cable Assembly","description":"\u003ch2\u003eYokogawa AKB337-M010 Shielded Signal Transmission Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AKB337-M010\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eYokogawa AKB337\u003c\/strong\u003e Shielded Signal Transmission Cable, operates as a dedicated hardware component for transmitting analog and digital signals within CENTUM VP, CS 3000, ProSafe-RS, and FA-M3 PLC networks. The hardware establishes physical Layer 1 connectivity between controllers, I\/O modules, and field terminal boards, executing direct data and electrical signal distribution without routing latency or active power overhead.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe formal product nomenclature details the functional interface design and specific length boundaries established for the multi-core cable assembly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (AKB337):\u003c\/strong\u003e Designates the core system cable architecture, incorporating a 20-pin to 20-pin proprietary interface pattern wrapped in a multi-core twisted pair layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength Suffix (-M010):\u003c\/strong\u003e Specifies the absolute physical length parameters determined at production. The -M010 indicator fixes the total assembly measurement to exactly 10 m, matching medium-range cabinet-to-cabinet interconnections or distributed marshalling panel runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAKB337-M010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 to 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10 m (Cable Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable (N\/A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e20-pin to 20-pin standard interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Material\u003c\/td\u003e\n\u003ctd\u003eCross-linked polyethylene (XLPE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Jacket Material\u003c\/td\u003e\n\u003ctd\u003ePolyvinyl chloride (PVC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding Structure\u003c\/td\u003e\n\u003ctd\u003eAluminum foil + braided copper shield (\u0026gt;= 85% coverage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e300 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Impedance\u003c\/td\u003e\n\u003ctd\u003e120 ohms plus or minus 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Typology\u003c\/td\u003e\n\u003ctd\u003eAnalog and digital current\/voltage loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Integration \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eOperating within complex industrial topologies, this cable assembly protects low-level voltage signals from adjacent field interference. The integration of an aluminum foil tape and a high-density braided copper shield with minimum 85% coverage isolates internal pairs from external electromagnetic noise. This grounding shield architecture guarantees signal integrity for parallel 4-20 mA HART loop protocol lines and high-frequency digital communication links. The twisted-pair cross-linked polyethylene insulation lowers cross-talk levels between adjacent channels, providing passive channel-to-channel isolation metrics that prevent electrical noise loops from corrupting real-time process control operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AKB337-M010 cable assembly be disconnected or swapped while the connected DCS I\/O modules are fully energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes, because this cable assembly is a passive electrical conductor with no active electronic components, physical disconnection will not cause an electrical surge or hardware damage. However, removing the 20-pin connector breaks the hardware link, instantly disrupting all analog or digital signals traveling through the cable and tripping the corresponding control loops.\u003c\/p\u003e\n\u003cp\u003eQ: How does the 120 ohm nominal impedance rating affect the physical deployment limits when mixing analog inputs and digital pulse streams?\u003c\/p\u003e\n\u003cp\u003eA: The 120 ohm nominal impedance configuration is matched to standard industrial signaling metrics to eliminate wave reflections along the 10 m line. This matching enables the cable to simultaneously handle slow 4-20 mA current loops and fast digital pulse signals without wave shape deformation or loss of measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Management:\u003c\/strong\u003e Maintain a strict minimum static bend radius of at least 10 times the cable outer diameter during mounting. Do not force sharp corners or kinks inside cabinet wireways, as this deforms the twisted-pair structure and lowers common-mode noise rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Protocol:\u003c\/strong\u003e Terminate the internal cable shield at a single reference point to prevent ground loops. Connect the shield braid directly to the cabinet instrument earth bus bar on the controller side, and keep the opposite terminal end isolated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Routing Separation:\u003c\/strong\u003e Route the 10 m cable through dedicated low-voltage wire trays. Keep a physical separation barrier of at least 300 mm from any high-power AC conductors, motor cables, or variable frequency drive outputs to avoid inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Engagement Lock:\u003c\/strong\u003e Seat both 20-pin terminal heads squarely into the matching receptacles on the I\/O modules or terminal boards. Tighten all mechanical locking screws completely to prevent pins from working loose due to low-frequency industrial cabinet vibrations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43683862872154,"sku":"AKB337-M010","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/635..jpg?v=1784600306","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-akb337-m010-20-pin-shielded-signal-cable-assembly","provider":"SpareOil Automation","version":"1.0","type":"link"}