{"product_id":"yokogawa-pw301-pw301-100-centum-power-supply-module","title":"Yokogawa PW301 PW301\/100 CENTUM Power Supply Module","description":"\u003ch2\u003eYokogawa PW301 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 100-120 VAC to DC voltage conversion and backplane power distribution in CENTUM CS\/VP systems, the \u003cstrong\u003eYokogawa PW301\/100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePW301\u003c\/strong\u003e Power Supply Module, provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (PW301):\u003c\/strong\u003e Standard Yokogawa System Power Supply Module designed to supply regulated DC power to Field Control Units (FCUs) and system communication buses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Suffix (\/100):\u003c\/strong\u003e Designates the 100-120 VAC input line voltage configuration operating at 50\/60 Hz with a 6.0 A maximum input current rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW301\/100 (PW301)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e44 x 264 x 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50-60 W output power capacity (6.0 A input at 100-120 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage 1\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC regulated (for internal logic circuits, up to 7.8 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage 2\u003c\/td\u003e\n\u003ctd\u003e24 VDC regulated (for I\/O and communication modules, up to 1.7 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant hot-standby configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eFused outputs, overvoltage, overcurrent, short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation \u0026amp; Fieldbus Loop Power Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe PW301\/100 module features complete galvanic isolation between the primary AC input and secondary DC output channels to prevent external line noise from corrupting internal bus signals. By delivering separate, regulated 5.1 VDC and 24 VDC rails, the unit insulates internal logic components while providing continuous power for 4-20 mA HART loops and fieldbus communication interfaces connected across the Field Control Unit chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PW301\/100 support hot-swapping during active system operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, hot-swapping is supported when the chassis is configured in a dual-redundant power setup and the secondary PW301\/100 module carries the full system load.\u003c\/p\u003e\n\u003cp\u003eQ: What primary mounting methods are supported for the module frame?\u003c\/p\u003e\n\u003cp\u003eA: The module installs directly into dedicated power supply slots within the standard CENTUM CS\/VP rack chassis using guide rails and secure faceplate mounting screws.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit protect downstream logic cards from power surges?\u003c\/p\u003e\n\u003cp\u003eA: Integrated overvoltage and fused overcurrent protection circuits automatically trip and clamp output lines to restrict fault current propagation into sensitive backplane logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eLine Voltage Disconnection: De-energize primary 100-120 VAC power feeds before wiring input terminals unless replacing a faulty unit under a verified online dual-redundant setup.\u003c\/li\u003e\n\u003cli\u003eSlot Alignment: Slide the module straight into the designated power supply slot along card cage guide channels until the rear multi-pin system connector seats fully against the backplane.\u003c\/li\u003e\n\u003cli\u003eScrew Attachment: Torque the top and bottom retaining thumbscrews to secure the assembly against vibration and establish continuous frame grounding to the chassis frame.\u003c\/li\u003e\n\u003cli\u003eConductor Separation: Route AC line voltage power cables away from low-voltage DC signals and fieldbus cables to prevent electromagnetic noise induction into analog control loops.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859587268698,"sku":"PW301\/100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/44_0d9a6e4d-71cc-46ff-87c6-a8819a214bf8.jpg?v=1787017664","url":"https:\/\/www.spareoil.com\/ar\/products\/yokogawa-pw301-pw301-100-centum-power-supply-module","provider":"SpareOil Automation","version":"1.0","type":"link"}