{"title":"Bachmann","description":"","products":[{"product_id":"00010464-00-mx220-bachmann-high-speed-real-time-cpu","title":"00010464-00 MX220 | Bachmann | High-Speed Real-Time CPU","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMX220 (Order Number: 00010464-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-tier Central Processing Unit (CPU) designed for the Bachmann M1 automation platform. As the primary intelligence hub for complex control architectures, it balances high-speed computational power with extreme thermal efficiency. The module is housed in a fanless, maintenance-free industrial enclosure, making it suitable for deployment in the most demanding environments, including wind turbine nacelles and maritime engine rooms.\u003c\/p\u003e\n\u003cp\u003eFeaturing a deterministic real-time architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMX220 (00010464-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures consistent cycle times for complex mathematical operations and high-speed logic execution. With integrated dual independent Ethernet controllers and non-volatile memory protection, this processor provides the reliability required for mission-critical industrial automation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMX220 (00010464-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built on an Intel-based architecture optimized for the M-OS real-time multitasking operating system.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMX220 (00010464-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed Intel-based industrial CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWorking Memory (RAM):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e256 MB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Program Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 MB Flash storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRetentive Data (nvRAM):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e512 kB battery-backed + 128 kB battery-free\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 × 10\/100 Mbit\/s (RJ45), independent controllers for network separation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 × RS232 plus 1 × configurable RS232\/422\/485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUSB Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 × USB 2.0 for service, firmware updates, and external storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7-segment LED display for boot codes and hardware health status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eM-OS Real-Time OS (supports C\/C++, IEC 61131-3, and MATLAB\/Simulink)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e127 mm × 51 mm × 127 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.58 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePassive, fanless design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870842032218,"sku":"MX220","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/171._45786542-ddb5-4c9f-ac0f-5710a1e61a45.jpg?v=1773113076"},{"product_id":"isolated-serial-communication-00012220-00-rs204-bachmann","title":"Isolated Serial Communication | 00012220-00 RS204 | Bachmann","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS204 (Order Number: 00012220-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance communication expansion module for the Bachmann M1 automation system. It provides four independent, software-configurable serial interfaces within a single-slot housing, enabling the central processor to manage multiple peripheral device streams simultaneously. This module is essential for integrating legacy hardware, specialized sensors, or third-party controllers into the M1 ecosystem.\u003c\/p\u003e\n\u003cp\u003eTo ensure deterministic performance and data integrity in harsh industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS204 (00012220-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 500 V RMS galvanic isolation between the ports and the system bus. Its rugged Austrian-built design provides high vibration resilience, making it a reliable choice for mission-critical applications in the maritime, energy, and heavy industrial sectors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS204 (00012220-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers flexible physical layer settings and hardware-buffered data handling to maintain high-speed communication without CPU congestion.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS204 (00012220-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Independent Serial Ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS232, RS422, RS485 (Selectable per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaud Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 115.2 kbit\/s per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS galvanic isolation (Ports to internal bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated hardware FIFO buffers per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs for TX (Transmit) and RX (Receive) activity per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-mounted D-Sub or terminal connectors (configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus RTU, NMEA 0183, and custom ASCII protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e55 mm × 55 mm × 120 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.24 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870842523738,"sku":"RS204","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/172._14f0dce6-d1ac-433c-939d-198d7bb74073.jpg?v=1773113342"},{"product_id":"bachmann-do232-00012240-00-0-5a-actuator-interface-card","title":"Bachmann DO232 (00012240-00) 0.5A Actuator Interface Card","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO232 (Order Number: 00012240-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital output module designed for the Bachmann M1 automation system. Occupying only a single-slot footprint, it provides 32 independent digital outputs, making it an ideal choice for driving high-volume industrial loads such as solenoid valves, contactors, and signaling devices.\u003c\/p\u003e\n\u003cp\u003eEngineered for mission-critical reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO232 (00012240-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates robust galvanic isolation (500 V RMS) between the field electronics and the system backplane. Each channel is equipped with comprehensive protection against short circuits and thermal overload, ensuring the safety of the central processor and continuous system uptime even during localized field faults.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO232 (00012240-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides deterministic actuator control with integrated diagnostic feedback for industrial environments.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO232 (00012240-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Digital Outputs (Sourcing\/High-side switching)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Operating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC (Acceptable range: 18 V to 34 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 A per channel (Max. total current depends on temperature and connector rating)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS (Field side vs system bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Circuitry:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShort-circuit protection per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal overload and over-temperature shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated freewheeling diodes for inductive load suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 individual green LEDs for channel status; 1 red LED for collective error reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching Behavior:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFast, deterministic switching optimized for resistive and inductive loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40-pin high-density front connector interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870844063834,"sku":"DO232","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/173._1e414208-62df-4916-8ac1-59bad1a23ce4.jpg?v=1773113696"},{"product_id":"64-channel-mixed-digital-i-o-bachmann-dio264-00012247-00","title":"64-Channel Mixed Digital I\/O | Bachmann DIO264 (00012247-00)","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO264 (Order Number: 00012247-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, multifunctional digital interface module engineered for the Bachmann M1 automation platform. Featuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e64 digital channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin a single-slot footprint, it provides exceptional hybrid flexibility: 16 of these channels are software-configurable as either inputs or outputs. This versatility allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO264 (00012247-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto replace multiple dedicated I\/O cards, significantly reducing hardware costs and cabinet space requirements.\u003c\/p\u003e\n\u003cp\u003eBeyond standard switching, the module is equipped with advanced on-board processing capabilities. It supports eight interrupt-capable inputs for rapid event response and four 32-bit hardware counters for precision motion tracking. Additionally, its Pulse Width Modulation (PWM) functionality enables energy-efficient \"valve economy\" control, making it a premier choice for hydraulic and high-speed industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO264 (00012247-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines high-speed signal acquisition with ruggedized output stages for deterministic control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO264 (00012247-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channel Count:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e64 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Channels (Individually programmable as Input or Output)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Interrupt-capable channels for microsecond-level response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCounter Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 × 32-bit hardware counters (Supports Incremental Encoder, Frequency, Event counting, and Cycle Time measurement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWM Output Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable on all outputs; configurable hold time (0–2 s) for valve economy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 A per channel (Parallel connection supported for higher loads)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e18–34 VDC (Integrated reverse polarity protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoftware-configurable hardware filters to eliminate contact bounce\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS between field electronics and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-visibility green LED per channel for real-time status monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870844620890,"sku":"DIO264","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/174._ffef3c25-720a-4bf2-8abf-e286f78b0057.jpg?v=1773114059"},{"product_id":"00010464-50-mx213-bachmann-m1-cpu-with-dual-ethernet","title":"00010464-50 | MX213 Bachmann | M1 CPU with Dual Ethernet","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMX213 (Order Number: 00010464-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance central processing unit designed for the Bachmann M1 automation platform. Engineered as a mid-to-high range controller, it delivers the fast, deterministic logic execution required for complex industrial systems. This module is optimized for high-speed motion control, extensive I\/O management, and multi-protocol communication within a single, fanless industrial housing.\u003c\/p\u003e\n\u003cp\u003eRunning on the proprietary M-OS real-time operating system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMX213 (00010464-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures microsecond-level synchronization and consistent cycle times. Its hardware is purpose-built for continuous operation in thermally demanding and high-vibration environments, such as wind turbine nacelles and maritime engine rooms. With integrated dual Ethernet and serial interfaces, it serves as a robust centralized hub for distributed automation networks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMX213 (00010464-50)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high computational density and reliable data retention for mission-critical logic.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMX213 (00010464-50)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade high-performance CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuntime Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated high-speed DRAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Storage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNon-volatile internal Flash memory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRetentive Data:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBattery-backed SRAM for process variable retention during power loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 × 10\/100 Mbit\/s (RJ45), independent controllers for network segmentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable RS232\/RS485 for peripheral integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann M-OS (Real-time multitasking)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocal Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7-segment LED display for boot states and hardware error codes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e127 mm × 51 mm × 127 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.6 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePassive cooling, fanless maintenance-free design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870844653658,"sku":"MX213","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/175._a41d994d-8d4a-4a0c-a971-9aa0d1a1a4d5.jpg?v=1773114461"},{"product_id":"bachmann-mpc240-00010460-00-128mb-dram-processor-module","title":"Bachmann MPC240 (00010460-00) 128MB DRAM Processor Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC240 (Order Number: 00010460-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, fanless CPU module designed for the Bachmann M1 automation platform. Engineered for deterministic real-time control, it is powered by a 400 MHz industrial processor capable of managing complex logic and synchronized processes in demanding environments.\u003c\/p\u003e\n\u003cp\u003eThis module serves as a reliable central processing unit for mid-to-high range applications, featuring dual independent Ethernet controllers that allow for physical network separation—a critical requirement for modern industrial security and performance. Its robust mechanical design and multi-tier memory architecture (DRAM, battery-backed SRAM, and battery-free nvRAM) ensure maximum system availability and data integrity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC240 (00010460-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to rigorous industrial standards, providing a stable foundation for the M-OS real-time operating system.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC240 (00010460-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCeleron \/ Pentium III equivalent, 400 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWorking Memory (RAM):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e128 MB DRAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Storage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 MB Flash (Includes 4 MB for M-OS system software)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRetentive Data (SRAM):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e512 kB (Battery-backed for process variables)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRetentive Data (nvRAM):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e64 kB (Battery-free for critical parameters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 × 10\/100 Base-TX Ethernet (RJ45, independent controllers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × RS232 (Fixed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Configurable RS232\/422\/485 (Serial interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × USB Interface (Service and expansion)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnosis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 7-segment LED status display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupplied via backplane (5 VDC \/ ±15 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePassive cooling (fanless design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870844850266,"sku":"MPC240","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/176._7160605d-591a-43a1-92c8-4d8048d4052c.jpg?v=1773114646"},{"product_id":"00012201-10-fs221-n-bachmann-m1-slave-with-integrated-psu","title":"00012201-10 | FS221\/N Bachmann | M1 Slave with Integrated PSU","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS221\/N (Part Number: 00012201-10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance FASTBUS slave substation interface module engineered for the Bachmann M1 automation system. It is designed to extend the controller's reach in distributed architectures, enabling high-speed real-time data exchange across distances up to 2,000 meters. A critical advantage of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS221\/N (00012201-10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its integrated 100W power supply, which energizes the local backplane and connected I\/O modules directly, effectively eliminating the need for additional NT series power units in remote racks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS221\/N (00012201-10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes deterministic fiber optic communication to maintain microsecond-level synchronization with the central master CPU.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS221\/N (00012201-10)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Role:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFASTBUS Slave (Remote Substation Interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 W (Powers internal bus and I\/O logic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC \/ 48 VDC (Nominal, variant dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Medium:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultimode Fiber Optic (High EMI immunity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2,000 meters between segments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Mbit\/s (Deterministic FASTBUS protocol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Connectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupport for LC Patch or Harting PushPull (IP65\/67)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSubstation Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupport for up to 15 distributed units per master\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull optical isolation between substation and master\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard M1 Backplane slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870845079642,"sku":"FS221\/N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/170._ef2880a7-63ad-4aa8-ade6-7a978ebe8549.jpg?v=1773112792"},{"product_id":"00012290-20-cnt204-h-bachmann-4-channel-counter-interface","title":"00012290-20 CNT204\/H Bachmann 4-Channel Counter Interface","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCNT204\/H (00012290-20)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized high-speed counter and positioning interface for the Bachmann M1 automation system. Engineered for precision tasks such as frequency measurement, phase-shift detection, and incremental encoder tracking, this module provides a hardware-based solution for pulse trains that exceed the capabilities of standard digital inputs. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCNT204\/H (00012290-20)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures four independent channels, two of which are specifically optimized for incremental encoders with A\/B tracks, ensuring synchronized data acquisition at the hardware level.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 4 independent counter channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncremental Encoder Support\u003c\/strong\u003e: 2 channels (supporting A\/B phase tracks)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Level\u003c\/strong\u003e: 24V HTL (High Threshold Logic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTiming Resolution\u003c\/strong\u003e: 42 ns (minimum pulse duration for period and differential measurement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Input Frequency\u003c\/strong\u003e: Up to 250 kHz (depending on mode and signal quality)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e: Frequency, Period, Incremental Counter, Phase-shift, Gate measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Isolation\u003c\/strong\u003e: 500 V RMS between field side and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e: Hardware-integrated clock for cross-channel precision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Integrated status LEDs for every input (channel activity and error states)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: Internal via backplane; encoder power available at front connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -30 °C to +60 °C (Cold-climate compliant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870845898842,"sku":"CNT204\/H","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/14_74345efb-7a3c-48f0-a64e-8c50a0e0a4a8.jpg?v=1773191248"},{"product_id":"bachmann-ptai216-00012278-00-precision-voltage-current-card","title":"Bachmann PTAI216 (00012278-00) Precision Voltage Current Card","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePTAI216 (Order Number: 00012278-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a professional-grade, high-density analog input module engineered for the Bachmann M1 automation system. Occupying only a single backplane slot, it provides 16 independent channels for high-precision sensor acquisition. The module is specifically designed to bridge the gap between high-volume data collection and limited cabinet space, offering a 16-bit resolution that ensures exceptional measurement accuracy for critical industrial processes.\u003c\/p\u003e\n\u003cp\u003eEquipped with 500 V RMS galvanic isolation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePTAI216 (00012278-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeffectively protects the internal system bus from field-side electrical interference and ground loops. Its versatile input stage allows for the simultaneous monitoring of various signal types, making it a cornerstone for condition monitoring in wind turbines and complex hydraulic systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePTAI216 (00012278-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-speed, deterministic sampling across all channels with the following hardware parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePTAI216 (00012278-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Analog Inputs (Single-ended or differential depending on wiring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16-bit A\/D conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e* Voltage: ±10 V, 0 to 10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent: 0 to 20 mA, 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.05% of Full Scale (typical at 25°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS between field and system electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e* Voltage mode: \u0026gt; 1 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent mode:  50 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated anti-aliasing filters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for real-time M1 bus cycle synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LED status indicators for hardware health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e55 mm x 55 mm x 120 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870846128218,"sku":"PTAI216","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/169._6a567ca7-61d8-48f9-b0c4-de28938e880d.jpg?v=1773112508"},{"product_id":"bachmann-bs210-00012130-00-10-slot-din-rail-backplane","title":"Bachmann BS210 (00012130-00) 10-Slot DIN Rail Backplane","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS210 (Order Number: 00012130-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity 10-slot backplane engineered for the Bachmann M1 automation system. It provides the essential physical and electrical infrastructure for large-scale controller configurations, offering high-speed internal bus connectivity for a CPU module, power supply, and up to eight expansion I\/O or communication modules.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-density integration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS210 (00012130-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the primary choice for complex automation hubs that require centralized processing of a large volume of signals. The unit features a vibration-resistant screw-locking system to ensure module stability in demanding environments such as offshore wind platforms or marine engine rooms. Additionally, lateral bus extension ports allow for seamless bridging with other BS series backplanes for modular system growth.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS210 (00012130-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes an integrated 16-bit high-speed parallel bus to ensure deterministic data exchange across all 10 slots.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS210 (00012130-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 slots total (Typically 1 CPU + 1 Power Supply + 8 Expansion Modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Bus:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 16-bit high-speed M1 parallel system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e35mm DIN rail (compliant with EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLateral bus connectors for multi-backplane coupling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVibration-resistant reinforced screw-locking system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (W×H×D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e550 mm × 119 mm × 23 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 (according to IEC 60664-1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReinforced industrial-grade housing for high mechanical stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870846357594,"sku":"BS210","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/168.1_a2bf2b89-af3b-4850-b290-6417bb054193.jpg?v=1773112224"},{"product_id":"bachmann-bs204-00012110-00-vibration-proof-4-slot-rack","title":"Bachmann BS204 (00012110-00) Vibration-Proof 4-Slot Rack","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS204 (Part Number: 00012110-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a fundamental 4-slot backplane designed for the Bachmann M1 automation system. It serves as the physical and electrical backbone for compact PLC configurations, providing structural support and high-speed internal bus connectivity. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS204 (00012110-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically accommodates one CPU module and up to three additional I\/O or communication modules.\u003c\/p\u003e\n\u003cp\u003eEngineered for reliability in high-vibration environments, such as wind turbine towers or maritime engine rooms, the backplane features a reinforced housing and a secure module-to-backplane screw locking system. Its lateral bus connectors allow for seamless side-by-side expansion, enabling engineers to bridge multiple backplanes to meet evolving system requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS204 (00012110-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures low-latency data transfer between the processor and expansion modules through its integrated system bus.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS204 (00012110-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 slots total (Typically 1 CPU + 3 expansion modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated high-speed M1 internal system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e35mm DIN rail mounting (compliant with EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLateral bus connectors for multi-backplane bridging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompact, vibration-resistant reinforced industrial housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Securing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated module-to-backplane screw locking mechanism\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 (according to IEC 60664-1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870846816346,"sku":"BS204","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/167._43d538d7-c7ca-4519-b082-0448fb3dd1c0.jpg?v=1773111967"},{"product_id":"00012235-00-di232-bachmann-m1-system-32-point-input","title":"00012235-00 | DI232 Bachmann | M1 System 32-Point Input","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI232 (Order Number: 00012235-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital input module engineered for the Bachmann M1 automation system. It consolidates 32 digital channels into a single-slot footprint, providing an efficient solution for high-volume signal acquisition. Designed for industrial-grade reliability, the module features robust galvanic isolation and configurable hardware filtering to ensure signal integrity in electrically noisy environments.\u003c\/p\u003e\n\u003cp\u003eWhether utilized for monitoring complex safety chains or gathering status feedback from hundreds of sensors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI232 (00012235-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers the precision and vibration resistance required for demanding applications in wind energy, maritime automation, and heavy manufacturing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI232 (00012235-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadheres to international IEC standards for programmable controllers, ensuring seamless integration with standard industrial sensors.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI232 (00012235-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Digital Inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogic Levels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eType 1 and Type 3 (compliant with IEC 61131-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 3.5 mA per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoftware-configurable from 1 ms to 5 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS (field circuitry to system bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 individual channel LEDs plus 1 system status LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Power Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.5 W from system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Power Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC external supply via front connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40-pin front connector (standard M1 interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-slot width with vibration-proof backplane locking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functional Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding 32 channels in a single slot significantly reduces the required cabinet width, making the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDI232 (00012235-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eideal for space-constrained retrofit projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe configurable input filters allow engineers to suppress contact bounce or electrical interference, ensuring the M1 CPU receives clean, debounced signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Sensor Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupport for Type 1 and Type 3 logic levels ensures compatibility with virtually all industrial 2-wire and 3-wire proximity sensors and switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWind Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReal-time monitoring of nacelle sensors, limit switches, and hydraulic status feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCentralized status acquisition for large-scale conveyor systems and production lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Interlock Chains:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density monitoring of door interlocks and emergency stop feedback circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870847471706,"sku":"DI232","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/166._13e0a957-e026-4548-8972-f2839e893cd0.jpg?v=1773111708"},{"product_id":"80-channel-digital-i-o-module-bachmann-dio280-00012248-00","title":"80-Channel Digital I\/O Module | Bachmann DIO280 (00012248-00）","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO280 (Order Number: 00012248-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital I\/O interface designed for the Bachmann M1 automation system. Engineering for maximum efficiency, it consolidates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80 channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(48 digital inputs and 32 digital outputs) into a single-slot footprint. This high-density architecture is specifically developed for space-constrained environments where high signal counts are required without expanding the physical rack size.\u003c\/p\u003e\n\u003cp\u003eEquipped with hardware-level input filtering and 500 V RMS galvanic isolation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO280 (00012248-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures signal integrity in harsh industrial and energy sectors. Its outputs feature integrated short-circuit and thermal protection, making it a reliable backbone for complex control systems in wind turbine nacelles and heavy industrial machinery.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO280 (00012248-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes precision-engineered components to handle high-volume signal processing within a compact thermal envelope.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO280 (00012248-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e80 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e48 Channels (24 VDC nominal, Type 1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLogic Low: \u0026lt; 5 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogic High: \u0026gt; 15 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Channels (24 VDC, 0.5 A max per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS (Field to system bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Circuitry:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOutputs: Short-circuit, thermal overload, and demagnetization protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInputs: Overvoltage protection and hardware filtering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSynchronous with the M1 system bus cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density LED array for individual channel status monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e108 × 57 × 121 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C (Standard version)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePollution Degree 2 according to IEC 60664-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870847701082,"sku":"DIO280","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/165._c5f7031a-54ec-4577-bf20-66df5fb3ee5b.jpg?v=1773111480"},{"product_id":"00012242-00-dio232-bachmann-m1-system-16-input-16-output","title":"00012242-00 | DIO232 Bachmann | M1 System 16 Input 16 Output","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO232 (Part Number: 00012242-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a mid-density digital input\/output module engineered for the Bachmann M1 automation system. Occupying a single-slot footprint, it provides 32 channels symmetrically divided into 16 digital inputs and 16 digital outputs. This module is designed for engineers seeking a balanced I\/O distribution for local or distributed control substations.\u003c\/p\u003e\n\u003cp\u003eEquipped with 500 V RMS galvanic isolation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO232 (00012242-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that field-side transients do not compromise the system electronics. Its robust construction and wide thermal range make it a standard choice for high-reliability sectors, including wind energy, maritime engine monitoring, and heavy industrial plant automation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO232 (00012242-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers deterministic signal processing, ensuring all I\/O states are updated in sync with the M1 system bus cycle.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO232 (00012242-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann M1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channel Count:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Channels (24 VDC, Type 1\/Type 3 per IEC 61131)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Channels (24 VDC, 0.5 A per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated short-circuit and thermal overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC (Range: 20.4 V to 28.8 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS (Field side to internal bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual LED status indicator per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Sync:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSynchronous update with M1 backplane bus cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized low-power design for internal electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupport for standard Bachmann front connectors (Screw or Push-in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertified for maritime and energy sector environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870847930458,"sku":"DIO232","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/164_525da15e-13db-459e-82cc-0a48b1163ae4.jpg?v=1773111254"},{"product_id":"bachmann-m1-fm221-00012200-10-dual-port-fastbus-interface","title":"Bachmann M1 FM221 (00012200-10) Dual-Port FASTBUS Interface","description":"\u003cp\u003eBachmann FM221 | 00012200-10 | FASTBUS Fiber Optic Master Module\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM221 (00012200-10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance FASTBUS Master module designed for the Bachmann M1 automation system. This dual-port fiber optic interface enables deterministic, real-time communication between a central processor and multiple remote I\/O substations. By utilizing HCS (Hard Clad Silica) fiber technology, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM221 (00012200-10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides complete galvanic isolation and absolute immunity to electromagnetic interference (EMI), making it the industry standard for demanding environments such as wind power nacelles and maritime engine rooms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: FASTBUS Master Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e: 2 x Independent Optical Ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Transmission Rate\u003c\/strong\u003e: 10 Mbit\/s (Deterministic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Medium\u003c\/strong\u003e: HCS Fiber Optic (200\/230 µm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Distance\u003c\/strong\u003e: 200 meters between segments (Total network span up to several kilometers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Connector\u003c\/strong\u003e: V-PIN (Versatile Link) standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e: Typically 300 mA at 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTopology Support\u003c\/strong\u003e: Daisy-chain, Star, and Tree structures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 55 x 80 x 118 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.30 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Topology and Connectivity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnlike the single-port variant, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM221 (00012200-10)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures two optical channels. This allows system integrators to implement redundant line structures or branch out into complex star topologies. The use of HCS fiber over Plastic Optical Fiber (POF) ensures significantly lower signal attenuation and higher mechanical durability, which is critical for long-term stability in vibrating industrial machinery.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Comparison: FM221 vs. FM211\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFM221\u003c\/strong\u003e: Dual optical ports. Supports network branching and more complex distributed architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFM211\u003c\/strong\u003e: Single optical port. Limited to simple point-to-point or end-of-line termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWind Energy\u003c\/strong\u003e: Bridging data communication between the base controller and the nacelle\/hub pitch systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaritime Engineering\u003c\/strong\u003e: Secure links between the bridge control systems and engine room I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Manufacturing\u003c\/strong\u003e: Connecting remote I\/O islands in large-scale plants where electrical interference prevents the use of copper cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870848782426,"sku":"FM221","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/13._b9a7b123-0254-4663-a444-3bd92aa86699.jpg?v=1773190698"},{"product_id":"high-density-i-o-interface-00012245-00-dio248-bachmann","title":"High-Density I\/O Interface | 00012245-00 DIO248 | Bachmann","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO248 (Order Number: 00012245-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital input\/output module specifically designed for the Bachmann M1 automation system. This module provides a significant I\/O concentration, featuring 32 digital inputs and 16 digital outputs within a single-slot footprint. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO248 (00012245-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an ideal solution for engineers looking to reduce hardware costs and panel space without compromising on signal integrity or diagnostic depth. It incorporates full galvanic isolation to protect the system backplane from field-side transients and electrical noise.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO248 (00012245-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadheres to international industrial standards, providing reliable 24 VDC logic interfacing for complex automation tasks.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO248 (00012245-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann M1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channel Count:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e48 Channels (High-density configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Channels (24 VDC, Type 1 according to IEC 61131)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Channels (24 VDC, 0.5 A per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated short-circuit and overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable via software (Default 1 ms hardware\/software filter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS between field circuitry and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual LED indicators for every channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUndervoltage detection for field supply and over-temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density front terminal blocks (Push-in or ribbon cable options)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870849667162,"sku":"DIO248","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/156_fbae3045-07ba-47e2-99dc-756da01cbf71.jpg?v=1773108255"},{"product_id":"bachmann-fm211-00012200-00-emi-immune-fiber-optic-master","title":"Bachmann FM211 (00012200-00) EMI-Immune Fiber Optic Master","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM211 (Part Number: 00012200-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed FASTBUS Master fiber optic communication module designed for the Bachmann M1 automation system. It serves as the primary interface for distributed I\/O architectures, converting internal bus signals into optical pulses. By utilizing fiber optic technology, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM211 (00012200-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures total EMI (Electromagnetic Interference) immunity and high-speed deterministic data transmission over long distances, making it a critical component for wind turbines, power plants, and maritime applications where signal integrity is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM211 (00012200-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for deterministic performance, ensuring consistent communication cycles required for real-time control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFM211 (Item No. 00012200-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFASTBUS Master Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann FASTBUS (Deterministic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Speed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Mbit\/s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMedium:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHCS (Hard Clad Silica) Fiber Optic Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized FASTBUS fiber optic ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 200 meters per segment (Point-to-point)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComplete galvanic isolation via optical medium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle slot in M1 backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LEDs for Link status, Activity, and Error detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaged via Bachmann SolutionCenter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870850125914,"sku":"FM211","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/433..jpg?v=1773107196"},{"product_id":"fiber-optic-fastbus-slave-bachmann-fs211-n","title":"Fiber Optic FASTBUS Slave | Bachmann FS211\/N","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS211\/N (Part Number: 00012201-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance FASTBUS slave interface module engineered for the Bachmann M1 automation system. It facilitates the creation of remote I\/O substations, allowing for real-time, deterministic data exchange with a central M1 master controller. A defining feature of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS211\/N (00012201-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its integrated 100 W power supply, which directly energizes the local backplane and all connected I\/O modules. This dual-functionality design eliminates the need for a separate system power module in the remote rack, significantly reducing hardware costs and cabinet space.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS211\/N (00012201-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for distributed architectures requiring low-latency signal processing across long distances.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS211\/N (00012201-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Role:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFASTBUS Slave Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 W (System bus supply for local I\/O)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e48 V DC (Range-tolerant for industrial grids)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Transmission Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Mbit\/s (Deterministic FASTBUS protocol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax. Communication Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200 meters per segment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Medium:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHCS (Hard Clad Silica) Fiber or High-grade Shielded Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 32 single-ended channels\/module mapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-level isolation between communication and logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs for Power, Link, and Data Activity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−20 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870850355290,"sku":"FS211\/N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/163._75ebeae2-f981-40c4-b0ea-240a4f6977ef.jpg?v=1773110162"},{"product_id":"bachmann-mpc270-00016400-00-800mhz-master-controller","title":"Bachmann MPC270 (00016400-00) 800MHz Master Controller","description":"\u003ch3\u003e\u003cstrong\u003eBachmann MPC270 | 00016400-00 | M1 High-Performance Processor Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC270 (Part Number: 00016400-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance central processing unit designed for the Bachmann M1 automation system. Built on a robust 32-bit ARM Cortex-A9 architecture, this controller is engineered to manage complex control algorithms and high-speed communication tasks with deterministic precision.\u003c\/p\u003e\n\u003cp\u003eWith its 800 MHz clock speed and substantial onboard memory (512 MB RAM \/ 1 GB Flash), the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC270 (00016400-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the computational hub for large-scale industrial applications. It supports up to 270 local and remote I\/O points, making it an ideal choice for consolidating decentralized automation architectures into a single, high-performance master controller. The fanless design ensures long-term reliability in harsh environments, from offshore wind turbines to maritime engine rooms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC270 (00016400-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines high-tier processing power with a real-time operating system (M-OS) to guarantee execution stability.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC270 (00016400-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32-bit ARM Cortex-A9\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClock Speed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e800 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e512 MB DDR3 RAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 GB Internal Flash (Application and data logging)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum I\/O Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e270 points (Sum of local backplane and remote stations)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Ethernet (10\/100\/1000 Mbit\/s)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x RS232 Serial Port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x USB 2.0 Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time OS:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann M-OS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Display:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 7-segment display for status and error codes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClock Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Real-Time Clock (RTC) with battery backup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-30 °C to +60 °C (Fanless)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% (Non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupport for external USB storage and CompactFlash\/SD (revision dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870851240026,"sku":"MPC270","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/162.1_1702ccbe-fb06-41d9-8b2f-6704eae79c33.jpg?v=1773110000"},{"product_id":"00012300-00-isi222-bachmann-m1-dual-axis-motion-control","title":"00012300-00 ISI222 | Bachmann | M1 Dual-Axis Motion Control","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISI222 (Order Number: 00012300-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an advanced dual-axis intelligent motion control module specifically engineered for the Bachmann M1 automation system. Unlike standard I\/O cards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISI222 (00012300-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a dedicated onboard processor that handles complex motion profile generation, velocity ramping, and closed-loop positioning locally. This \"edge intelligence\" effectively offloads high-speed calculations from the main M1 CPU, eliminating communication latency and ensuring deterministic performance for precision-critical axis control.\u003c\/p\u003e\n\u003cp\u003eEquipped with high-speed incremental encoder interfaces and integrated digital I\/O for drive management, the module is a versatile solution for high-dynamic positioning tasks in a compact, single-slot backplane footprint.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISI222 (00012300-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-fidelity feedback and control signals with robust electrical isolation for industrial reliability.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISI222 (00012300-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDedicated onboard motion processor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Independent high-speed axes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncremental (Supports A, B, and Zero\/Index tracks)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Levels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS422, TTL, or 24V DC (Model\/Hardware configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCounter Depth:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32-bit (Wide range for long-travel actuators)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Digital I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Digital Inputs \/ 4 Digital Outputs (For limit switches, home sensors, and drive enable\/status)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePositioning Modes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePoint-to-point, Velocity control, Electronic gearing (Follower mode)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS between field circuitry and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs for channel status, error reporting, and pulse activity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard M1 module footprint\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann SolutionCenter with standard motion libraries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870851469402,"sku":"ISI222","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/161._1e078c98-db92-4b91-ac5e-858c8ca2c4a4.jpg?v=1773109622"},{"product_id":"acr222-2-bachmann-axis-module-datasheet-technical-manual","title":"ACR222\/2 Bachmann Axis Module Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eBachmann ACR222\/2 M1 Motion Control System\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed pulse generation and closed-loop positioning in Bachmann M1 Automation System architectures, the \u003cstrong\u003eBachmann ACR222\/2\u003c\/strong\u003e (\u003cstrong\u003eACR222\/2 (00012285-10)\u003c\/strong\u003e Step\/Direction Axis Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eACR222\/2 (Part Number: 00012285-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e63 x 119 x 63 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard M1 system operating limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18-34 VDC (Reverse polarity protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAxis Capacity\u003c\/td\u003e\n\u003ctd\u003e2 Independent stepper channels (Step\/Direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003eMaximum 150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder Interface\u003c\/td\u003e\n\u003ctd\u003e2 x 24-bit resolution (RS422 \/ HEDL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Encoder Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Levels\u003c\/td\u003e\n\u003ctd\u003eHigh: 3-34 V, Low: 0-2 V (Imax 10 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe module relies on internal high-velocity backplane bus communication pathways to cross-reference data frames directly with the main processing node. This allows the internal 24-bit quadrature inputs and 150 kHz step generation channels to synchronize without data lag. The physical sub-circuits maintain exact firmware flash compatibility across standard M1 control chassis variations, ensuring predictable I\/O density scaling during concurrent processing of multi-axis linear positioning profiles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the internal encoder excitation voltage set for RS422 or HEDL feedback devices?\u003c\/p\u003e\n\u003cp\u003eA: The onboard encoder power supply logic provides selectable outputs of +5 V or +15 V. The exact voltage configuration is determined via internal physical jumpers located on the module circuit board prior to slot engagement.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane integration restrictions when adding this module to a live M1 rack?\u003c\/p\u003e\n\u003cp\u003eA: The module does not support hot-swap insertion. The entire M1 system backplane rack must be completely powered down before seating the hardware to prevent data disruption or component logic latch-up.\u003c\/p\u003e\n\u003cp\u003eQ: How does the pulse generation circuit respond to step commands exceeding the maximum range?\u003c\/p\u003e\n\u003cp\u003eA: The step range limits operate from 1 to 16,777,215 pulses per discrete command. Values initiated outside these bounds are intercepted by the module firmware driver and flag a positional overflow status register bit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Slide the module housing carefully into the designated M1 backplane slot along the physical guide rails to secure direct mating with the high-velocity bus connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Topology:\u003c\/strong\u003e Connect encoder and step\/direction signal lines using twisted-pair shielded cables, and land the drain wires on the central panel enclosure bulkhead earth rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Routing:\u003c\/strong\u003e External excitation lines supplying 18-34 VDC must be sized correctly to accommodate peak step drive logic loads without causing localized voltage drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Isolation:\u003c\/strong\u003e Route the pulse output signal paths separate from high-current AC motor supply lines to reduce inductive cross-talk and maintain clean 150 kHz signal boundaries.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870851698778,"sku":"ACR222\/2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/160..jpg?v=1773109317"},{"product_id":"cm202-bachmann-can-communication-module-new-original-stock","title":"CM202 Bachmann CAN Communication Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann CM202 CAN Communication Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann CM202 (00012160-00)\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCM202\u003c\/strong\u003e CAN Communication Module, operates as a dedicated hardware component for 2-channel CAN communication within Bachmann M1 Automation System networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCM202 (Item No. 00012160-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard M1 module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Channels\u003c\/td\u003e\n\u003ctd\u003e2 Independent CAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eCANopen (Master\/Slave), DeviceNet, J1939, CAN Layer 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e10 kbit\/s up to 1 Mbit\/s (Software configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V (between CAN channels and system bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCANopen Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 128 TxPDO and 128 RxPDO per network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the host controller via high-velocity backplane bus communication pathways, allowing real-time data sync across the physical network. Bus interface logic handles deterministic network transfers for J1939, DeviceNet, and CANopen profiles without incurring processing jitter. It scales I\/O density requirements by transmitting up to 128 TxPDO and 128 RxPDO parameters per network channel, maintaining firmware flash compatibility across standard M1 controller variations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the firmware flash compatibility requirements when replacing a legacy module variant?\u003c\/p\u003e\n\u003cp\u003eA: The hardware requires the M1 system software version to support the corresponding device driver profiles configured via the Bachmann SolutionCenter. Ensure the controller firmware matches or exceeds the module revision level.\u003c\/p\u003e\n\u003cp\u003eQ: How is the backplane bus current load affected when installing multiple modules?\u003c\/p\u003e\n\u003cp\u003eA: Each interface draws power directly from the 5 V and 24 V internal backplane rails. Total current calculations must sum the module requirements against the maximum rating of the M1 power supply card to prevent voltage sag.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum physical isolation voltage rating between the two separate CAN interfaces?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic isolation blocks potential differences up to 500 V between the individual CAN channels and the internal system backplane components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Connection Sequence:\u003c\/strong\u003e Power down the entire M1 backplane rack before inserting or removing the module from the bus slots to avoid data disruption or electrical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Resistor Placement:\u003c\/strong\u003e Install standard 120 Ohm termination resistors at the physical endpoints of each CAN bus segment to suppress signal reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Connect the CAN cable shield directly to the functional earth ground terminal rail at the cabinet entry bulkhead using low-impedance ground clamps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate Constraints:\u003c\/strong\u003e Match network cable segment lengths to the configured baud rates, keeping total distances within 40 meters when operating at the maximum 1 Mbit\/s velocity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870851928154,"sku":"CM202","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/432.jpg?v=1773106830"},{"product_id":"00012220-00-lm201-bachmann-m1-backplane-placeholder","title":"00012220-00 | LM201 | Bachmann | M1 Backplane Placeholder","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLM201 (Part Number: 00012220-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a mechanical blank filler module designed specifically for the Bachmann M1 automation system backplanes (such as the BS206 and BS210). While the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLM201 (00012220-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtains no electronic components, it is a critical accessory for maintaining the integrity of the PLC rack. It serves as a protective placeholder for unpopulated slots, preventing the ingress of dust and contaminants while ensuring that internal airflow is correctly channeled to active modules. By filling empty positions, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLM201 (00012220-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealso enhances the vibration resistance and mechanical stability of the entire control system assembly.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLM201 (00012220-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to the same high industrial standards as active Bachmann modules to ensure a perfect fit and environmental compliance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Order Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLM201 (00012220-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann M1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMechanical slot filler \/ placeholder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReinforced, industrial-grade plastic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e54 × 118 × 54 mm (Standard single-slot width)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.18 kg (0.4 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirect insertion into M1 backplane slots with standard locking mechanism\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDust ingress prevention and airflow optimization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with standard M1 system range (−30 °C to +60 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhances overall rack stability in high-motion environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870852386906,"sku":"LM201","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/159.1_a51236d2-a236-46b7-9a55-296bd636f918.jpg?v=1773109080"},{"product_id":"00012170-00-nt255-bachmann-24v-logic-power-supply-module","title":"00012170-00 | NT255 Bachmann | 24V Logic Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNT255 (Part Number: 00012170-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the fundamental power regulation module for the Bachmann M1 automation system. Engineered for installation in Slot 1 of the M1 backplane, it converts a standard external 24 VDC input into the precise, low-noise internal voltages required to drive the processor modules, communication interfaces, and I\/O cards. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNT255 (00012170-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the system's electrical heartbeat, featuring high efficiency and integrated protective circuitry to ensure continuous operation in demanding industrial environments like wind farms and maritime vessels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNT255 (00012170-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides robust galvanic isolation and voltage stabilization to protect the internal logic bus from external fluctuations.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNT255 (00012170-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem Power Supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC (Acceptable range: 18–34 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 85% at nominal load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eM1 System Bus power distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Position:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBackplane, Slot 1 (Primary slot)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOvervoltage Protection (OVP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-circuit Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Overload (Automatic shutdown)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs for \"Power OK\" and \"Fault\" status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e130 × 57 × 67 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.35 kg (0.77 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–30°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePassive convection through the M1 chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870853271642,"sku":"NT255","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/157_6693a06a-faf3-4a13-86d4-11ce4752b599.jpg?v=1773108653"},{"product_id":"bachmann-aio288-1-00012270-00-rtd-potentiometer-module","title":"Bachmann AIO288\/1 (00012270-00) RTD \u0026 Potentiometer Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIO288\/1 (Part Number: 00012270-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, multifunctional analog interface module engineered for the Bachmann M1 automation system. This module consolidates 8 analog inputs and 8 analog outputs into a single-slot footprint, providing an optimal balance of density and performance for space-constrained control cabinets.\u003c\/p\u003e\n\u003cp\u003eDesigned for versatile signal acquisition, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIO288\/1 (00012270-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures dedicated support for Pt100\/Pt1000 RTD sensors and integrated excitation for up to four potentiometers. With 14-bit resolution and advanced wire-break diagnostics, it ensures high-fidelity data conversion and operational safety in demanding industrial environments such as wind energy and hydraulic control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIO288\/1 (00012270-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides robust galvanic isolation and professional-grade accuracy for complex feedback loops.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Ordering Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIO288\/1 (00012270-00)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Channels (8 Analog Inputs \/ 8 Analog Outputs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Input Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±10 V (Single-ended or Differential)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Output Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e14-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12-bit (typical for M1 analog logic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRTD Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 × Pt100 \/ Pt1000 temperature sensor channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Excitation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated power for up to 4 potentiometers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.1% (typical, fully calibrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V RMS galvanic isolation (field side to system bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual wire-break detection and error status monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870853730394,"sku":"AIO288","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/158._385d7736-d36b-4285-a356-e153268b0b1b.jpg?v=1773108817"},{"product_id":"pcc200-bachmann-00010313-00-plc-program-backup-memory","title":"PCC200 Bachmann 00010313-00 | PLC Program \u0026 Backup Memory","description":"\u003ch3\u003e\u003cstrong\u003eBachmann PCC200 00010313-00 M1 System PCMCIA Flash Memory Card\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePCC200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00010313-00\u003c\/strong\u003e) is an industrial-grade PCMCIA Flash memory module specifically engineered for the Bachmann M1 automation system. Functioning as a high-reliability, non-volatile storage medium, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePCC200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for storing PLC application programs, system configurations, firmware, and retentive data. Its primary role in the M1 ecosystem is to serve as an external boot and backup device, ensuring that the controller can restore its full operating state immediately after a power loss or hardware replacement. Built with rugged FLASH technology, it eliminates the risk of data corruption common in standard consumer cards, providing a stable foundation for critical control tasks in energy and transportation infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePCC200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows strict industrial memory standards to ensure compatibility with legacy and current Bachmann processor modules.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bachmann Electronic GmbH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePCC200\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00010313-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Capacity\u003c\/strong\u003e: 8 MB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Technology\u003c\/strong\u003e: Non-volatile FLASH (Industrial Grade)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Standard\u003c\/strong\u003e: PCMCIA (Type I\/II)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 5 V DC (Read\/Write)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgramming Voltage\u003c\/strong\u003e: 12 V DC (Internal conversion)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Retention\u003c\/strong\u003e: \u0026gt; 10 years without power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCPU Compatibility\u003c\/strong\u003e: Supports M1 single-core and legacy quad-core processor modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e: Data accessible via Ethernet, Modbus, or TCP\/IP when installed in CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 85.6 × 54 × 3.3 mm (Standard PCMCIA Form Factor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 °C to +60 °C (Industrial Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: −40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Austria\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870854156378,"sku":"PCC200","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/71._d4adb4c7-bec5-4444-b20c-7a9403230486.jpg?v=1770945183"},{"product_id":"cnt204-r-bachmann-00012290-20-m1-motion-control-interface","title":"CNT204\/R Bachmann 00012290-20 | M1 Motion Control Interface","description":"\u003ch3\u003e\u003cstrong\u003eBachmann CNT204\/R 00012290-20 M1 System Counter Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCNT204\/R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012290-20\u003c\/strong\u003e) is a professional-grade, high-speed counter and position measurement module specifically engineered for the Bachmann M1 automation platform. This module is designed to bridge the gap between high-frequency field signals and the controller logic, offering four independent channels for pulse acquisition. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCNT204\/R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile solution for motion control, providing flexible interface options for both HTL (24V) pulse generators and RS422 (5V) incremental encoders. With its high-resolution 32-bit architecture and advanced timing analysis capabilities, it is a critical component for applications requiring nanosecond-level precision in velocity, frequency, or period duration measurements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCNT204\/R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines robust electrical isolation with high-speed signal processing hardware.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bachmann Electronic GmbH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCNT204\/R\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012290-20\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Counter Channels\u003c\/strong\u003e: 4 independent channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 32-bit per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Support (Standard)\u003c\/strong\u003e: 4 x HTL single-line pulse generator inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncremental Encoder Support\u003c\/strong\u003e: 2 x RS422 (A, B, Zero\/Reference) inputs (optional channel use)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax. Input Frequency\u003c\/strong\u003e: 20 kHz (Standard HTL), higher with RS422 configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePeriod Measurement Resolution\u003c\/strong\u003e: 42 ns (nanoseconds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e: Integrated, adjustable from 183 Hz to 46.88 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: 500 V RMS between field signals and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Monitoring\u003c\/strong\u003e: Integrated voltage sensing for reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: Typ. 2.5 W from system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: −30 °C to +60 °C (industrial extended range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Austria\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Performance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Timing Analysis\u003c\/strong\u003e: Beyond simple counting, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCNT204\/R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels at period duration measurement with a resolution of 42 ns, making it ideal for high-accuracy speed calculations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMixed Logic Compatibility\u003c\/strong\u003e: Supports 5V RS422 differential signals and 24V HTL levels, ensuring compatibility with virtually any industrial rotary or linear encoder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Signal Filtering\u003c\/strong\u003e: Configurable hardware filters allow engineers to suppress high-frequency noise and contact bounce, ensuring signal integrity in high-EMI environments like wind turbine nacelles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Encoder Power\u003c\/strong\u003e: The module can provide power directly to the connected sensors via the terminal block, simplifying cabinet wiring and reducing external component counts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Diagnostics\u003c\/strong\u003e: Each channel is equipped with a green status LED for immediate visual verification of pulse activity, while the system software monitors for undervoltage and hardware faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870854615130,"sku":"CNT204\/R","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/70._4d4d542a-f559-402d-aca0-fc5ccf678631.jpg?v=1770944912"},{"product_id":"dio216-bachmann-00012240-00-industrial-configurable-i-o","title":"DIO216 Bachmann 00012240-00 | Industrial Configurable I\/O","description":"\u003ch3\u003e\u003cstrong\u003eBachmann DIO216 00012240-00 M1 System Digital 16-Channel I\/O Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO216\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Order Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012240-00\u003c\/strong\u003e) is a highly versatile digital interface module designed for the Bachmann M1 automation platform. It features 16 high-density channels that are individually configurable, allowing each point to function as either an input or an output. This \"all-in-one\" flexibility allows engineers to optimize cabinet space and minimize spare part inventories by adapting a single module to varying field requirements. Engineered for the rigors of heavy industry, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO216\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes 3-wire connection technology to simplify wiring for sensors and actuators while providing robust galvanic isolation to safeguard the system bus from electromagnetic interference and field-side transients.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO216\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its adaptive hardware configuration and industrial-grade electrical protection.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bachmann Electronic GmbH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO216\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012240-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e: 16 individually configurable (Input or Output)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e: 15–34 VDC (Nominal 24 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Level Input Voltage\u003c\/strong\u003e: 0–5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e: Typ. 4 mA (IEC 61131 Type 1\/3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e: Typ. 600 µs (Software programmable up to 5 ms)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 24 VDC (dependent on supply voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e: Up to 1.0 A per channel (Max total current limited by supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Circuitry\u003c\/strong\u003e: Short-circuit, overload, and over-temperature protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: 500 V RMS galvanic isolation (field to system bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e: 3-wire technology for direct sensor\/actuator wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e: Green LED per channel for I\/O state; Red LED for local faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -30°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 120 × 60 × 25 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.14 kg (0.30 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870854844506,"sku":"DIO216","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/69_85110e76-110a-49b5-9a37-05f2abb5cf64.jpg?v=1770944737"},{"product_id":"bachmann-bs206-6-slot-high-speed-internal-bus-backplane","title":"Bachmann BS206 6-Slot High-Speed Internal Bus Backplane","description":"\u003ch3\u003e\u003cstrong\u003eBachmann BS206 00012130-00 M1 Automation System 6-Slot Backplane\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS206\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012130-00\u003c\/strong\u003e) is a precision-engineered 6-slot backplane that serves as the essential communication and power distribution hub for the Bachmann M1 automation system. Designed to meet the rigorous demands of industrial environments, this unit facilitates high-speed data transfer between processor modules and I\/O modules via an integrated internal system bus. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS206\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a rigid mechanical architecture and vibration-resistant module locking mechanisms, ensuring continuous signal integrity in heavy-duty applications. Its modular interlocking design allows for easy lateral expansion, enabling engineers to scale control systems from simple logic tasks to complex, multi-rack process automation architectures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS206\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for reliability and high-performance system bridging:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bachmann Electronic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS206\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00012130-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Slot Capacity\u003c\/strong\u003e: 6 slots for M1 series modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Bus\u003c\/strong\u003e: Integrated high-speed internal communication bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution\u003c\/strong\u003e: Conducted via the backplane from the central power supply module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e: 35 mm DIN rail (compliant with EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e: Reinforced industrial-grade polycarbonate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: −30 °C to +60 °C (−22 °F to +140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: −40 °C to +85 °C (−40 °F to +185 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Ports\u003c\/strong\u003e: Lateral connectors for bridging multiple backplanes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Securing\u003c\/strong\u003e: Vibration-proof screw locking system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e: IP20 (when fully populated with modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: Optimized for medium-density cabinet layouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Performance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMedium-Density Footprint\u003c\/strong\u003e: The 6-slot configuration provides an ideal balance between physical space and I\/O capacity, suitable for localized control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Vibration Resistance\u003c\/strong\u003e: Specifically designed for extreme environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBS206\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains stable electrical contacts even when subjected to the constant mechanical stress found in wind turbines or marine engines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Scalability\u003c\/strong\u003e: The lateral bridging capability allows the system bus to extend across multiple backplane units without external wiring, simplifying complex system setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Power Management\u003c\/strong\u003e: Eliminates the need for multiple external power feeds by distributing a stabilized supply from the primary power module in Slot 1 across all secondary slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTool-Free Installation\u003c\/strong\u003e: The integrated DIN rail clip facilitates rapid mounting and dismounting, significantly reducing assembly time during cabinet builds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":42870855073882,"sku":"BS206","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/68._6b5a5b67-984e-4533-8e8d-388d0a5a48f0.jpg?v=1770944404"},{"product_id":"bachmann-dio264-c-configurable-64-point-digital-slave","title":"Bachmann DIO264-C Configurable 64-Point Digital Slave","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann DIO264-C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a high-density, standalone CAN slave module designed for distributed control architectures. This versatile unit provides up to 64 configurable digital channels, allowing engineers to tailor the input\/output ratio to specific machine requirements without hardware swaps. By connecting directly to the CAN bus via dual D-Sub ports, the DIO264-C eliminates the need for expensive backplanes and complex rack assemblies. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, ensuring seamless integration into your Bachmann or third-party CANopen networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DIO264-C combines extreme channel density with robust electrical protection to maintain signal integrity in high-interference environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIO264-C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 Configurable Channels (Input or Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 64 Channels; \u0026lt;3.5 ms delay; 6 kΩ Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 32 Channels; 18–34 V DC; 1 A per Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCAN Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 × 9-pin D-Sub (Node ID 1–254)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kbps to 1000 kbps (Auto-negotiation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V Galvanic Isolation (CAN to Electronics)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit and Overload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 50022 DIN Rail Snappable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DIO264-C resolves the challenges of high-point-count remote sensing by offering a decentralized, backplane-free solution.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Configuration Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike fixed-ratio modules, the DIO264-C allows you to define channels as inputs or outputs. This adaptability reduces spare part inventory, as a single DIO264-C unit can replace multiple variations of lower-density fixed modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStand-Alone Network Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module functions as a complete CAN node. By removing the requirement for a local CPU or backplane, it reduces the physical footprint in remote junction boxes and lowers the overall system cost per I\/O point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Output Current Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach output channel delivers up to 1 A of continuous current. This capability allows the module to drive heavy-duty solenoids, hydraulic valves, and large contactors directly, bypassing the need for interposing relays in many applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Loop-Through Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual 9-pin D-Sub ports facilitate easy \"daisy-chain\" wiring. This simplifies the CAN bus trunk layout and ensures that the communication signal remains stable across the entire network branch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500V galvanic isolation protects the internal control logic from field-side electrical noise and ground loops. This protection ensures reliable data transmission even when the module sits adjacent to high-frequency variable speed drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DIO264-C require a separate bus terminator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module supports loop-through, you must install an external 123\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003etermination resistor at the physical end of the CAN bus segment to prevent signal reflections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module with non-Bachmann controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The DIO264-C follows standard CAN communication protocols (Node ID range 1–254), making it compatible with any industrial PLC or PC-based controller that supports CANopen or standard CAN frames.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum output switching frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports switching frequencies up to 500 Hz. This high-speed performance makes it suitable for pulse-width modulation (PWM) tasks and rapid-cycle packaging machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a lower-density version of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor applications requiring fewer points, Bachmann offers the DIO16-C (16 channels) and DIO32-C (32 channels), both of which share the same standalone CAN slave architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166103928922,"sku":"DIO264-C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/470.jpg?v=1775034849"},{"product_id":"high-speed-sync-backplane-100-brand-new-bs202-bachmann","title":"High-Speed Sync Backplane 100% Brand New | BS202 Bachmann","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann BS202\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary electrical and structural backbone for the M200 automation platform. Unlike standard DIN rail mounts, this module provides a high-speed functional bus that facilitates deterministic communication between CPUs, power supplies, and I\/O modules. It establishes the critical data link required for synchronized motion control and multi-axis robotics. We supply this component in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal condition, ensuring the mechanical and electrical integrity of your distributed control system.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe BS202 utilizes a modular design to provide high-bandwidth data transfer and precise synchronization across the system backplane.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBS202\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Family\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM200 Automation System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBus Terminal \/ Backplane Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIO-Bus-Sync \u0026amp; PreSYNC Mechanisms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBS200 Series (BS201–BS216)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL Approved\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe BS202 eliminates the latency associated with traditional external wiring by providing an integrated, high-speed synchronization path.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports Bachmann’s proprietary IO-Bus-Sync and PreSYNC technologies. These mechanisms ensure that all connected modules execute tasks with microsecond precision, which is vital for high-speed production lines and complex robotic movements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Bus Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe BS202 provides full electrical bus capabilities, surpassing simple mechanical supports. It manages the data traffic between the processor and I\/O modules, maintaining signal purity even in environments with heavy electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs a key component of the BS200 family (ranging from BS201 to BS216), the BS202 allows for flexible system expansion. Engineers can scale the hardware configuration to match the specific slot requirements of the machine without redesigning the cabinet layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Resistant Interconnects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-quality gold-plated contacts ensure a gas-tight electrical connection. This prevents intermittent communication faults in heavy industrial applications where constant machine vibration is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Cabinet Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim DIN rail form factor reduces the overall width of the PLC rack. This compact design allows for higher component density within the control enclosure, effectively lowering cabinet costs and footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between a BS202 and an S202 adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BS202 is an active bus terminal that provides electrical communication and synchronization between modules. The S202 is typically a passive DIN rail adapter used for mechanical support only, lacking the integrated bus architecture required for PLC operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this backplane support all M200 series modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The BS202 provides universal compatibility for M200 processors, power supply modules, and various digital or analog I\/O cards within the Bachmann ecosystem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many modules can I connect to a BS202?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BS202 serves as a specific slot segment in the backplane assembly. For larger systems requiring more modules, you can combine or select other models in the BS200 series (up to BS216) to meet your specific slot count needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the PreSYNC mechanism benefit motion control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePreSYNC allows for the simultaneous latching of input data and the synchronized output of control commands across multiple modules. This eliminates \"jitter\" and ensures that multi-axis drives start and stop in perfect harmony.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166105043034,"sku":"BS202","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/471..jpg?v=1775035062"},{"product_id":"00014647-00-bachmann-bms-hvac-integration-module","title":"00014647-00 Bachmann BMS HVAC Integration Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann 00014647-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance communication gateway, bridging Bachmann programmable logic controllers (PLCs) with BACnet MS\/TP networks. This module eliminates the need for expensive external protocol converters by providing native BACnet integration. It excels in Building Management Systems (BMS) and smart infrastructure, allowing the PLC to manage up to 128 BACnet objects simultaneously. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition with original packaging, ensuring a seamless, high-reliability link between your industrial hardware and facility management layers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 00014647-00 utilizes a high-speed processing core to handle complex object management and real-time alarm synchronization.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e00014647-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBACnet MS\/TP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eObject Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 128 BACnet Objects\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Discovery, Property Access, Alarm\/Event Handling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTime Synchronization Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug-and-Play System Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Network Health Monitoring Tools\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAustria\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 00014647-00 optimizes building automation projects by simplifying the data hierarchy and reducing commissioning time.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Protocol Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy embedding BACnet MS\/TP capabilities directly into the PLC rack, this module removes the latency and points of failure associated with third-party gateways. This direct link ensures faster response times for critical HVAC and lighting control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomated Device Discovery:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes an \"auto-discovery\" algorithm to identify existing BACnet devices on the network. This feature significantly reduces manual configuration errors and slashes commissioning hours during large-scale infrastructure deployments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Object Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting up to 128 objects—including analog inputs, binary outputs, and multistate variables—the 00014647-00 handles the density required for complex chillers, air handling units (AHUs), and energy monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Diagnostic Suite:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated software tools monitor network health and traffic load. Engineers use these diagnostics to troubleshoot baud rate mismatches or address conflicts without requiring external protocol analyzers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile primarily used in commercial BMS, the module meets CE industrial standards. Its rugged construction resists electromagnetic interference (EMI) and temperature fluctuations typical of mechanical plant rooms and industrial rooftops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support BACnet\/IP or just MS\/TP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 00014647-00 specifically supports the BACnet MS\/TP (Master-Slave\/Token-Passing) protocol over twisted-pair wiring. For BACnet\/IP requirements, please consult our alternative Bachmann networking modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the 128 objects?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfiguration occurs through Bachmann’s standard engineering environment. The \"plug-and-play\" architecture allows you to map PLC internal variables directly to BACnet object properties with minimal coding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module act as a BACnet Time Master?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports time synchronization functions, allowing it to either receive time updates from a central BMS or broadcast its internal clock to synchronize other devices on the MS\/TP segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 00014647-00 compatible with older Bachmann PLC series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module integrates with the current M1 automation system. Always verify your specific CPU firmware version to ensure full support for the latest BACnet object profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166106452058,"sku":"00014647-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/472.jpg?v=1775035342"},{"product_id":"mpc265-bachmann-multi-core-industrial-processor","title":"MPC265 Bachmann Multi-Core Industrial Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann MPC265\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-performance computational core of the M1 automation system. This multi-core processor module handles complex, high-speed algorithms required for wind turbine pitch control, marine dynamic positioning, and precision robotics. It integrates dual Ethernet ports and CAN bus connectivity natively, supporting deterministic execution through the Bachmann Real-Time Operating System (RTOS). We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, providing the sub-millisecond precision necessary for mission-critical industrial applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe MPC265 architecture focuses on high memory throughput and synchronized multi-tasking for large-scale distributed control.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMPC265\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32\/64-bit Multi-Core CPU (\u0026gt;1 GHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard RAM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e256 MB to 1 GB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Expansion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCF Card Slot (Up to 8 GB supported)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x Ethernet, 1x CAN, optional PROFIBUS\/PROFINET\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOPC UA, Modbus TCP\/RTU, IEC 61131-3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSync Precision\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSync error \u0026lt;10 μs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61508 SIL3 Capable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP67 Ruggedized Housing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C (-4°F to 158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe MPC265 hardware resolves the limitations of standard PLCs by combining edge computing power with extreme environmental resilience.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Multi-Axis Sync:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe MPC265 maintains synchronization errors at less than 10 microseconds. This level of precision allows for perfect coordination between dozens of motion axes, making it a standard choice for CNC machinery and high-speed robotic cells.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy and Failover:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports redundant CPU architectures with a failover time of less than 50 milliseconds. In wind power or marine applications, this ensures that the system maintains control of the pitch or thrusters even during a primary hardware fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized for Extreme Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn IP67 protection rating and an extended temperature range (-20°C to +70°C) allow for installation in offshore nacelles or engine rooms. The MPC265 operates reliably where standard commercial-grade controllers fail due to vibration or humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Edge Computing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in data processing capabilities allow the MPC265 to perform local analytics and condition monitoring. By processing data at the source, the module reduces the bandwidth required for cloud communication and enables faster predictive maintenance responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrated Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompliance with IEC 61508 SIL3 allows engineers to implement safety-critical functions within the same controller framework, simplifying the overall system design and reducing hardware footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the MPC265 include a CompactFlash (CF) card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard CPU modules typically require a separate industrial-grade CF card for the operating system and user application. We recommend Bachmann-certified CF cards (up to 8 GB) to ensure data retention and write-cycle durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the MPC265 handle hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe M1 system backplane and MPC265 architecture support hot-swappable module replacement. This allows maintenance teams to replace I\/O modules while the CPU continues to manage the process, provided the system configuration permits it.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the MPC265 for OPC UA communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The MPC265 natively supports OPC UA, facilitating secure and direct communication with SCADA systems, ERP layers, and other IIoT platforms without needing an external gateway.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the MPC265 compatible with older M1 power supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MPC265 integrates with standard M1 system backplanes and power modules. However, always verify that your power supply provides sufficient current for the increased power requirements of the multi-core processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166109892698,"sku":"MPC265","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/473.jpg?v=1775035809"},{"product_id":"bachmann-isi202-plc-encoder-interface-100-brand-new","title":"Bachmann ISI202 PLC Encoder Interface 100% Brand New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann ISI202\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a high-precision encoder interface within the M1 automation ecosystem. This module provides a dual-channel solution for capturing position and speed data from both incremental and Synchronous Serial Interface (SSI) encoders. Beyond signal acquisition, the ISI202 features dual analog outputs and digital trigger inputs, allowing the module to function as a self-contained closed-loop controller for motion applications. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal condition, ensuring sub-microsecond signal evaluation for your most demanding robotics and CNC tasks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ISI202 utilizes advanced differential signal processing to maintain accuracy at high input frequencies.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISI202\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEncoder Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (Incremental or SSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (Reference or Trigger signals)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Channels (±10 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Input Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MHz (Incremental) \/ Up to 5 MHz (SSI Mode)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCounter Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24-Bit (Software-extendable to 32-Bit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA, A+, B, B+, N, N+ (Differential)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEvaluation Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-edge, 2-edge, 4-edge, or Pulse\/Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Monitoring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous external supply tracking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ISI202 solves the challenge of high-speed synchronization between physical position feedback and actuator command signals.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Encoder Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accepts both RS422 incremental signals and SSI absolute data. This flexibility allows engineers to standardize on the ISI202 regardless of whether the machine uses traditional pulse-train encoders or modern digital absolute sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Control Loop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual ±10V analog outputs enable the module to drive motor controllers or hydraulic valves directly based on the encoder feedback. This localizes the control loop, reducing backplane traffic and improving overall system response times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Signal Evaluation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ISI202 supports 1x, 2x, and 4x edge evaluation modes. By evaluating every signal edge, the module quadruples the effective resolution of standard incremental encoders, providing ultra-fine positioning for precision machining.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a maximum input frequency of up to 5 MHz in specific modes, the ISI202 tracks high-speed shafts without losing pulses. This makes it a critical component for high-speed turbine monitoring and rapid-cycle packaging lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Diagnostic Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module continuously monitors external supply voltages and signal integrity. Integrated LEDs provide immediate visual feedback on encoder power status and signal presence, simplifying on-site troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix an incremental encoder and an SSI encoder on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ISI202 supports independent configuration for its two channels, allowing you to interface one incremental and one SSI encoder simultaneously if required by your system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the software expansion to 32-bit resolution work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware natively tracks up to 24 bits. For applications requiring a larger range (such as long-travel linear actuators), the Bachmann software environment handles the overflow to extend the effective counter range to 32 bits without losing accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ISI202 provide power to the encoder?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supplies the necessary excitation voltage directly via the connectors, eliminating the need for external power distribution blocks for your sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable type should I use for the differential signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure 1 MHz\/5 MHz performance and minimize EMI, always use shielded, twisted-pair cabling for the A\/B\/N signal lines. Connect the shield to the designated ground point on the ISI202 terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166110941274,"sku":"ISI202","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/475.jpg?v=1775036221"},{"product_id":"mpc293-bachmann-pentium-class-industrial-processor","title":"MPC293 Bachmann Pentium-Class Industrial Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann MPC293\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the high-performance central processing unit for the Bachmann M1 automation platform. Equipped with an embedded Pentium-class processor, this module executes complex control algorithms with absolute deterministic real-time behavior. It serves as the primary intelligence for large-scale distributed architectures in renewable energy, marine engineering, and sophisticated manufacturing cells. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal condition, ensuring your system maintains maximum computational throughput and microsecond-level synchronization.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe MPC293 integrates high-speed communication interfaces with expandable memory architecture to support data-intensive automation tasks.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMPC293\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Family\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann M1 Automation Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmbedded Pentium-Class CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeterministic Real-Time Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnboard RAM (Expandable via CF Card)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Ethernet Ports, Integrated CAN Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 × 160 × 25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAustria\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe MPC293 hardware architecture resolves the processing bottlenecks found in traditional PLCs by utilizing PC-based computational power within an industrial form factor.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePentium-Class Computational Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated Pentium-class CPU handles high-level language programming and complex mathematical models simultaneously. This enables the controller to perform advanced PID regulation and predictive maintenance analytics without degrading cycle times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Real-Time Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBachmann’s proprietary real-time operating system ensures that every control task executes within its assigned time window. This eliminates \"jitter\" in high-speed motion control and ensures perfect synchronization across distributed I\/O banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Communication Backbone:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual Ethernet ports facilitate redundant network topologies. This architecture ensures the CPU maintains contact with the HMI and SCADA layers even if a primary network cable fails, significantly increasing overall plant availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Storage Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard CompactFlash (CF) card slot allows for easy memory upgrades and project backups. Engineers swap CF cards to update firmware or move applications between CPUs, reducing MTTR (Mean Time To Repair).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Thermal Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its high-speed processor, the MPC293 utilizes an efficient heat dissipation design that allows it to operate reliably up to +60°C. This eliminates the need for internal cooling fans, which are frequent points of failure in dusty industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the MPC293 require a fan for cooling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The MPC293 utilizes a fanless design for maximum reliability. It dissipates heat through its high-performance aluminum housing, preventing dust ingress and mechanical wear associated with cooling fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard CF cards for memory expansion?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe strictly recommend industrial-grade CompactFlash cards. Standard consumer cards lack the write-cycle endurance and thermal stability required for the Bachmann M1 operating system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the MPC293 compatible with the latest M1 software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The MPC293 integrates seamlessly with Bachmann’s SolutionCenter and supports standard IEC 61131-3 programming as well as C\/C++ for custom algorithmic development.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical boot time for the MPC293?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Pentium-class architecture ensures a rapid boot sequence. Typically, the module enters a \"Run\" state and establishes communication with the I\/O bus in a matter of seconds after power-on, depending on the complexity of the user application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166113497178,"sku":"MPC293","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/472._b8fa944b-1532-47b1-b8a4-72320490cff3.jpg?v=1775036410"},{"product_id":"bachmann-00020628-00-aio208-m1-system-analog-card","title":"Bachmann 00020628-00 AIO208 M1 System Analog Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann AIO208\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number: 00020628-00) provides a high-density, flexible solution for analog signal processing within the M1 automation platform. This module features 8 universal channels that engineers can individually configure as either inputs or outputs. It supports all industrial standard signals, including voltage (±10 V) and current (4–20 mA), making it the primary interface for pressure transmitters, flow meters, and proportional valves. We supply this module in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal condition, ensuring 16-bit measurement precision for your critical process control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AIO208 utilizes advanced A\/D and D\/A converters to deliver linear, high-resolution performance across the entire signal spectrum.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAIO208 \/ 00020628-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Configurable (Input or Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 V, 0–10 V, 0–20 mA, 4–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 V, 0–10 V, 0–20 mA, 4–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Bit A\/D and D\/A Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation (Channels to System Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 200 k$\\Omega$ (Voltage) \/ 50 \u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e118 × 35 × 87 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe AIO208 architecture resolves the common industrial challenge of mixed-signal requirements by consolidating inputs and outputs into a single hardware footprint.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHybrid Channel Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 8 channels operates independently. This eliminates the need to purchase separate 4-channel input and 4-channel output cards, effectively halving the required DIN rail space for small-to-medium scale analog tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior 16-Bit Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-bit-depth conversion allows the module to maintain extreme accuracy even when measuring signals that do not span the full range (such as a 0–5 V sensor mapped to a 0–10 V range). This provides the \"overhead\" necessary for precise PID tuning in temperature and pressure control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Bus Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated galvanic isolation shields the sensitive M1 system bus from field-side electrical noise and ground loops. This protection prevents transient surges from damaging the central CPU or other I\/O modules in the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Signal Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module handles standard ±10 V to ±10 mV voltage ranges and 0\/4–20 mA current loops. This broad compatibility allows you to standardize on the AIO208 across diverse sectors, including wind energy, marine engineering, and process manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in monitoring circuits detect wire breaks (in 4–20 mA mode) and short circuits. The module reports these errors directly to the CPU, allowing for immediate alarm triggering and reduced troubleshooting time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure 4 channels as inputs and 4 as outputs simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The AIO208 allows for any combination of inputs and outputs within its 8-channel limit. You define the function of each channel during the software configuration phase in the Bachmann SolutionCenter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external power for 4–20 mA loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module typically requires an external 24V DC supply to power the analog circuitry and field-side loops. Ensure your power supply provides clean, regulated DC to maintain the ±0.1% accuracy specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the AIO208 compatible with the AIO216?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth modules belong to the same Bachmann analog family and share signal characteristics. The AIO208 offers 8 channels, while the AIO216 provides 16 channels for higher-density applications. They are interchangeable in terms of logic and signal type support.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle signals smaller than 10V, such as 0–5V?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 16-bit resolution provides high granularity even if the physical signal only utilizes half of the 0–10V range. You simply scale the values within the PLC software to match your specific sensor calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166116937818,"sku":"AIO208","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/476..jpg?v=1775036812"},{"product_id":"00009634-00-bachmann-bs209-9-slot-expansion-rack","title":"00009634-00 Bachmann BS209 9-Slot Expansion Rack","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann BS209\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number: 00009634-00) constitutes the primary mechanical and electrical foundation for medium-to-large Bachmann M1 automation assemblies. This 9-position backplane facilitates high-speed data communication between the central processor, power supply, and up to seven additional I\/O or communication modules. By integrating Bachmann’s proprietary synchronization mechanisms, the BS209 ensures deterministic performance across all connected hardware. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(2022 Manufacture), providing a stable, high-performance platform for your distributed control architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe BS209 provides the physical bus infrastructure necessary for millisecond-level task execution within the M1 environment.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBS209 \/ 00009634-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 Positions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann M1 Automation System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports IO-Bus-Sync and PreSYNC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 35mm DIN Rail (EN 50022)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.3 cm × 5.5 cm × 11.9 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Year\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2022\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAustralia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe BS209 optimizes complex control cabinet layouts by consolidating multiple expansion requirements into a single, high-density backplane.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e9-Slot Expansion Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe BS209 offers significant slot density, allowing for a complete system configuration—including CPU, Power Supply, and multiple Fieldbus or Analog I\/O modules—on a single rack. This minimizes the need for expansion cables and secondary racks, reducing overall system latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic IO-Bus-Sync:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated backplane bus supports Bachmann’s IO-Bus-Sync technology. This ensures that all 9 slots receive and transmit data in perfect synchronization, a requirement for high-speed motion control and multi-axis robotics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Interconnects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-quality backplane connectors provide gas-tight electrical contacts that resist oxidation. This maintains the integrity of the high-speed bus signals even in environments subject to thermal cycling and industrial pollutants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Heat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe narrow 2.3cm profile and modular design promote natural convection airflow between the backplane and the installed modules. This prevents heat concentration behind the CPU, extending the operational lifespan of the internal electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined DIN Rail Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe snappable mounting mechanism allows for rapid installation on standard DIN rails. This design simplifies both the initial assembly of the control cabinet and any future field service requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the BS209 include the bus termination?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BS209 provides the internal bus paths for the 9 slots. In a single-rack configuration, the system typically requires a bus terminal or end-cap depending on the specific M1 modules used. Always refer to your CPU's hardware manual for termination requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different module types in the 9 slots?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The BS209 serves as a universal interface for the M1 system. You can install any combination of Bachmann digital I\/O, analog I\/O, communication interfaces, and processor modules, provided they follow the M1 slot addressing rules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this backplane compatible with older M1 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BS209 belongs to the standard BS200 series and maintains full compatibility with the M1 automation platform. It supports both legacy and current-generation M1 modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of a 2022 manufactured unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNewer manufacture dates ensure that the hardware utilizes the latest material components and adheres to the most recent manufacturing tolerances. This provides maximum longevity and reliability compared to older \"New Old Stock\" (NOS) units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166137024602,"sku":"BS209","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/477..jpg?v=1775037080"},{"product_id":"bs212-bachmann-high-speed-sync-12-position-baseboard","title":"BS212 Bachmann High-Speed Sync 12-Position Baseboard","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann BS212\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-density mechanical and electrical foundation for the Bachmann M1 automation system. Featuring 12 module slots, this backplane provides the necessary infrastructure for large-scale control configurations, linking the central processor and power supply with an extensive array of I\/O and communication modules. It eliminates the need for multiple smaller racks by consolidating system components into a single, synchronized bus. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, ensuring deterministic data exchange for complex energy, marine, and manufacturing applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe BS212 utilizes a robust internal bus architecture to maintain signal integrity across all 12 expansion positions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBS212\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Family\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann M1 Automation System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Module Positions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIO-Bus-Sync and PreSYNC Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 35mm DIN Rail Compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Bus\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed internal M1 system bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL Approved\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe BS212 addresses the complexities of large-scale automation by providing a centralized, high-speed interconnectivity solution.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density 12-Slot Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis backplane accommodates up to 12 modules, making it the standard choice for complex machine control where high point counts for digital and analog I\/O are required. It reduces the physical complexity of the control cabinet by housing the entire PLC assembly on a single continuous bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Synchronization (IO-Bus-Sync):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe BS212 supports Bachmann's proprietary IO-Bus-Sync and PreSYNC mechanisms. These features ensure that data from all 12 slots reaches the CPU simultaneously, preventing the phase shifts and timing jitter that often plague large-scale distributed I\/O systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStructural and Electrical Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rugged baseboard design provides a stable mechanical platform for heavy CPU and power modules. High-quality electrical contacts ensure gas-tight connections, preventing signal degradation caused by industrial vibrations or atmospheric corrosives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Cabinet Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its 12-slot capacity, the BS212 maintains a compact DIN rail form factor. This allows engineers to snap the entire rack into place quickly, streamlining the assembly process and reducing labor costs during panel builds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Bus Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal bus architecture handles high-bandwidth data transfers effortlessly. Whether you are running high-speed motion control profiles or extensive process telemetry, the BS212 maintains consistent bus cycle times across all occupied slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I combine the BS212 with other backplanes in the BS200 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Bachmann M1 system allows for expansion beyond a single rack. While the BS212 provides 12 slots on one baseboard, you can use expansion cables to link it with other BS200 series modules (from BS201 to BS216) to increase total system capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need to fill all 12 slots for the backplane to function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The BS212 functions with any number of modules from 1 to 12. Unused slots do not affect the electrical performance of the bus, though we recommend using bus covers for protection in dusty environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the BS212 compatible with both AC and DC power supply modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe backplane provides the electrical paths for the system voltage. It is compatible with all M1-series power supply modules (NT series), which deliver the required internal voltages to the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the BS212 handle grounding?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features integrated grounding contacts that interface directly with the DIN rail. For optimal EMI protection, ensure the DIN rail itself has a low-impedance connection to the central functional earth (FE) of the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166231330906,"sku":"BS212","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/477.1_a62f5cec-03c5-4f87-a7cf-ad1112acb3ca.jpg?v=1775037332"},{"product_id":"gm260-bachmann-4-quadrant-energy-counter-plc-card","title":"GM260 Bachmann 4-Quadrant Energy Counter PLC Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann GM260\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-speed, precision acquisition unit for three-phase electrical networks within the M1 automation environment. It enables the simultaneous monitoring of two separate three-phase branches from a single voltage reference point, calculating True RMS values online. This module performs advanced harmonic analysis up to the 40th harmonic, providing essential data for power quality assessment in wind turbines, hydroelectric plants, and industrial microgrids. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, ensuring laboratory-grade measurement accuracy for your critical power generation assets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe GM260 integrates 16-bit A\/D conversion with high-speed digital signal processing to evaluate complex grid variables in real-time.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGM260\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase (2 separate branches via 1 voltage point)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 690 V AC (Nominal), Galvanically Isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCT inputs (1 A \/ 5 A Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCalculation Mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrue RMS including harmonics (up to 40th)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz – 1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnergy Counting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Integrated 4-Quadrant Energy Counters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Detection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver\/Under Voltage \u0026amp; Frequency, Phase Imbalance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit A\/D Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe GM260 architecture replaces multiple standalone power meters and protection relays by integrating all grid-monitoring functions into the PLC backplane.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Harmonic Analysis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard analog cards, the GM260 calculates harmonics up to the 40th order online. This allows engineers to detect non-linear load interference and prevent premature equipment failure caused by total harmonic distortion (THD) in industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual 4-Quadrant Energy Counting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module integrates two separate 4-quadrant counters, measuring active, reactive, and apparent power in both consumption and generation directions. This proves vital for renewable energy systems that fluctuate between grid-tie feeding and local consumption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronous Machine Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated algorithms detect phase imbalances and frequency shifts instantaneously. These features allow the GM260 to act as a high-speed protection interface, triggering safety shutdowns or load shedding faster than traditional external relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic High-Voltage Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirect 690 V AC inputs utilize high-grade galvanic isolation to protect the M1 system bus. This design eliminates the need for external voltage transducers for standard 690V industrial grids, saving cabinet space and reducing wiring errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Grid Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports generator-to-grid synchronization by providing precise phase-angle and frequency data to the CPU. This enables smooth paralleling of generators in marine dynamic positioning or decentralized power systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor two different generators with one GM260?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GM260 monitors two separate current branches but shares a common voltage monitoring point. If your generators share a common busbar voltage, you can acquire the current data for both simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external Current Transformers (CTs)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The current inputs utilize standard 1 A or 5 A secondary signals from external CTs. You must configure the CT ratio within the Bachmann software to ensure accurate scaling of the primary current values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle high-frequency transients?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 16-bit A\/D conversion and 1 kHz frequency range capture rapid fluctuations. However, for lightning-strike level transients, you should still install standard external surge protection devices (SPDs) upstream of the voltage inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the GM260 compatible with IEC 61850?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen paired with an appropriate Bachmann communication processor (like an MPC series CPU), the data acquired by the GM260 can be mapped to IEC 61850 data objects for substation automation and smart grid integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166328717402,"sku":"GM260","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/478..jpg?v=1775037641"},{"product_id":"wt205v-bachmann-analog-output-module-new-original-stock","title":"WT205V Bachmann Analog Output Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann WT205V M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann WT205V\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eWT205V\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for 8-channel analog signal loop execution within Bachmann M1 Automation System networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWT205V (Item No. 00014431-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg (variant dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard M1 enclosure dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 VDC @ 150 mA (Local Bus), 24 VDC @ 300 mA (Bussed Field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 independent analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA with HART transparency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePer-Channel Field Circuit\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g half-sinewave, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm p-p (2-13.2 Hz), 0.7 g (13.2-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe module transmits converted analog control values directly across internal high-velocity backplane bus communication pathways to regulate downstream field interfaces without processing lag. Backplane communication logic handles simultaneous updates for all 8 output channels, allowing loop synchronization while executing deterministic data transfers from the central processing assembly. The integrated hardware layer maintains continuous firmware flash compatibility, allowing users to execute I\/O density scaling options across the M1 chassis platform without impacting real-time telemetry processing loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the backplane interface respond during an active firmware flash sequence?\u003c\/p\u003e\n\u003cp\u003eA: The module locks output channel parameters to safe-state limits when a firmware flash sequence modifies the controller assembly, blocking random signal transmission across the high-velocity backplane bus communication channels.\u003c\/p\u003e\n\u003cp\u003eQ: What are the continuous backplane bus load limits for local bus and bussed field power?\u003c\/p\u003e\n\u003cp\u003eA: The hardware architecture draws a fixed current load of 150 mA at 12 VDC from the local bus power rail, and 300 mA at 24 VDC from the bussed field power rail to energize the output channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module handle live backplane hot-swap operations within the M1 rack?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal backplane bus interface requires the main rack assembly to be completely powered down before insertion or removal to prevent physical data channel corruption or voltage damage to the bus logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the module housing with the physical chassis tracks and seat it firmly into the M1 backplane to secure the high-velocity bus connection before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Connect all 4-20 mA signal wire shields directly to the copper enclosure earth ground rail at the cable bulkhead entry using low-impedance ground clamps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosive Gas Isolation:\u003c\/strong\u003e Verify that the enclosure seals remain intact in fields exceeding ISA-S71.04-1985 Class G3 thresholds to protect the conformal coating matrix from aggressive atmospheric contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation:\u003c\/strong\u003e Route all low-voltage analog output and HART loops in dedicated wire ducts isolated from high-current AC power cables to prevent electromagnetic cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431335985242,"sku":"WT205V","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/288._571c73aa-c9ac-421c-ab53-b5fe2ccd9ccb.jpg?v=1780019923"},{"product_id":"isi222-8-bachmann-positioning-module-new-original-stock","title":"ISI222\/8 Bachmann Positioning Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann ISI222\/8 M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann ISI222\/8\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eISI222\/8\u003c\/strong\u003e Positioning Module, operates as a dedicated hardware component for dual-axis motion control and encoder feedback processing within Bachmann M1 Automation System networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eISI222\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 25 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2 incremental\/SSI encoder channels, 4 fast digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2 analog outputs (14-bit resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounter Resolution\u003c\/td\u003e\n\u003ctd\u003eFull 32-bit counter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003eUp to 8 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between channels and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail \/ M1 base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe positioning module relies on high-velocity backplane bus communication pathways to execute real-time synchronization with the master controller. This architecture supports integrated system synchronization (I\/O-Bus-Sync) to lock the 32-bit counter values and encoder data frames to the system clock cycle without incurring jitter. It allows scalable I\/O density options while maintaining firmware flash compatibility with M-SMC, M-CNC, and M-SHAFT system profiles, converting physical encoder pulses into deterministic logic variables.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle encoder line faults under extreme operating conditions?\u003c\/p\u003e\n\u003cp\u003eA: The internal hardware features built-in continuous error monitoring circuits that perform real-time cable break detection and encoder voltage monitoring to isolate intermittent ESD or wiring failures.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module accept higher frequency inputs without data loss?\u003c\/p\u003e\n\u003cp\u003eA: The internal optical isolation and hardware counter structures are rated to support maximum input pulse frequencies up to 8 MHz on the incremental encoder tracking channels.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane load restrictions regarding live module swapping?\u003c\/p\u003e\n\u003cp\u003eA: The hardware architecture requires a complete system backplane power shutdown before inserting or pulling the module from the M1 base rack to avoid interrupting bus communication logic or causing electrical latch-up.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Unit Alignment:\u003c\/strong\u003e Insert the module firmly into the M1 base unit chassis tracking, verifying that the high-velocity backplane bus connectors match completely before locking the assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Connect encoder and analog command line shields to the main functional earth grounding bar at the cabinet entrance utilizing low-impedance ground clamps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Separation Architecture:\u003c\/strong\u003e Route high-frequency encoder wires (up to 8 MHz) inside dedicated conduits isolated from 400 VAC motor power feeds to block magnetic cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screw Tensioning:\u003c\/strong\u003e Torque all field terminal wiring points to standard industrial specifications to maintain reliable physical contacts in high-vibration control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431336771674,"sku":"ISI222\/8","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/289.1_152d3448-1de4-4a60-964c-5932de3b8e6b.jpg?v=1780020212"},{"product_id":"slc284-bachmann-security-processor-module-new-original-stock","title":"SLC284 Bachmann Security Processor Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann SLC284 M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic logic execution in Bachmann M1 Automation System platforms, the \u003cstrong\u003eBachmann SLC284\u003c\/strong\u003e (\u003cstrong\u003eSLC284\u003c\/strong\u003e Security Processor Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSLC284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 100 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between channels and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail \/ M1 base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, IEC standards, IEC 61508 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe security processor module relies on internal high-velocity backplane bus communication pathways to cross-examine data registers across safety network nodes without software jitter. The physical layer processes dedicated safe communication links to distributed input\/output blocks over standard bus expansions, FASTBUS, CAN, or bluecom networks. This architecture scales internal I\/O density requirements while enforcing firmware flash compatibility across safety-rated controller chassis variants, converting internal CPU logic frames into deterministic field execution signals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane integration restrictions regarding live hot-swapping for this security processor?\u003c\/p\u003e\n\u003cp\u003eA: The hardware architecture lacks hot-swap support. The entire backplane base rack must be completely powered down before seating or removing the module to prevent electrical damage to the system bus components.\u003c\/p\u003e\n\u003cp\u003eQ: How is the total current demand validated when all 32 output channels are active?\u003c\/p\u003e\n\u003cp\u003eA: Each channel manages a maximum current load of 0.5 A at 24 VDC. Total simultaneous current consumption must be calculated against the maximum backplane power supply rating to avoid voltage drops on the internal bus logic.\u003c\/p\u003e\n\u003cp\u003eQ: Does the system software require specific licenses to enable the integrated safety functions?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Utilizing the dedicated safety communication pathways and IEC 61508 execution logic requires the corresponding backplane bus communication velocity licenses to be loaded into the engineering software environment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Chassis Engagement:\u003c\/strong\u003e Slide the module firmly along the structural rails of the base unit chassis to secure proper physical seating with the high-speed backplane interface before applying auxiliary power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Connect all digital control wire shields to the master cabinet grounding rail using low-impedance grounding clamps to prevent electrical noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation Rules:\u003c\/strong\u003e Route the 24 VDC low-voltage signal lines through dedicated wire paths separated from high-voltage AC motor or inductive breaker switching circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Retaining Torque:\u003c\/strong\u003e Tighten all field wiring screws to standard engineering torque matrices to eliminate high-resistance points under continuous industrial machine vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431340539994,"sku":"SLC284","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/290._dc9e37a3-cf51-42a8-96bc-1323d3cbdd9c.jpg?v=1780020772"},{"product_id":"cpc210-bachmann-cpu-processor-module-new-original-stock","title":"CPC210 Bachmann CPU Processor Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann CPC210 M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann CPC210\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCPC210\u003c\/strong\u003e CPU Processor Module, operates as a dedicated hardware component for control logic execution within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCPC210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 100 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Speed\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e64 MB SDRAM, 16 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eBachmann real-time OS (VxWorks architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003e2x Ethernet (10\/100 Mbit), 1x RS-232, 1x CAN bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe processor module utilizes an integrated system architecture to establish low-latency communication via internal high-velocity backplane bus communication pathways. This localized interface logic enforces microsecond-level synchronization across neighboring input\/output channels, preventing signal jitter when executing motion trajectories or fast sequence loops. This high-density backplane interface optimizes total I\/O density scaling options while ensuring absolute firmware flash compatibility between peripheral functional cards and the central real-time VxWorks kernel.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the processor handle peripheral configuration changes during an active firmware flash sequence?\u003c\/p\u003e\n\u003cp\u003eA: An active firmware flash requires the processor to transition out of execution mode into a safe standby state. Peripheral I\/O modules connected across the high-velocity backplane will drop to predefined safe values until the master boot block reinitializes.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current load limit this module can draw from the 24 VDC bus input?\u003c\/p\u003e\n\u003cp\u003eA: The central processor assembly has a nominal power consumption of approximately 10 W at 24 VDC. Auxiliary module additions across the backplane bus will scale the total system power consumption metrics and must be calculated against the main supply limits.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CAN bus interface require independent physical termination at the module connector?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When utilizing the embedded CAN bus interface for networking field devices, a standard 120 Ohm termination resistor must be physically installed across the terminal pins at the end points of the network line.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Alignment Matrix:\u003c\/strong\u003e Insert the module along the chassis tracking grooves until the internal multi-pin backplane bus adapter locks with the connector interface to prevent pins from bending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Clamp all Ethernet and CAN bus communications cables directly to the master copper ground terminal rail at the cabinet entrance to mitigate high-frequency interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Power Circuits:\u003c\/strong\u003e Route the 24 VDC processor supply conductors in wiring ducts separated from 400 VAC motor leads or variable frequency drive cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Clearance Boundaries:\u003c\/strong\u003e Maintain a minimum 50 mm free space envelope above and below the module assembly to allow correct convection airflow over the internal heat sinks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431344046170,"sku":"CPC210","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/291_10a9c5dd-b6c8-4845-a67d-b76bdf309295.jpg?v=1780021823"},{"product_id":"mpc240-w-bachmann-cpu-processor-module-new-original-stock","title":"MPC240\/W Bachmann CPU Processor Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann MPC240\/W M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann MPC240\/W\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMPC240\u003c\/strong\u003e CPU Processor Module, operates as a dedicated hardware component for automation program execution within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMPC240\/W (MPC240-64\/512 variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 100 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Speed\u003c\/td\u003e\n\u003ctd\u003e400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB SDRAM, 32 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eBachmann real-time OS (VxWorks architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003e2x Ethernet (10\/100 Mbit), 1x RS-232, 1x CAN bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe processor module establishes high-velocity backplane bus communication pathways to regulate downstream peripheral interfaces without introducing software scheduling jitter. This localized hardware execution environment guarantees real-time cycle synchronization across high-density digital and analog I\/O points. By keeping critical control matrices tied directly to the central VxWorks kernel runtime engine, the unit manages variable I\/O density scaling options while ensuring permanent firmware flash compatibility across legacy and current M1 system configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the functional constraints concerning live backplane hot-swapping for this central processor?\u003c\/p\u003e\n\u003cp\u003eA: This CPU card does not support hot-swap capabilities. The internal backplane bus interface requires a complete power shutdown of the M1 rack before unseating or inserting the module to prevent digital component failure.\u003c\/p\u003e\n\u003cp\u003eQ: How are field module parameters affected during an active firmware flash sequence on the CPU?\u003c\/p\u003e\n\u003cp\u003eA: When executing a firmware flash sequence, the processor halts active program execution, driving connected backplane modules to predefined safe fallback states until the software image is verified and reloaded.\u003c\/p\u003e\n\u003cp\u003eQ: Does the embedded CAN bus channel require separate external power or termination?\u003c\/p\u003e\n\u003cp\u003eA: The physical CAN bus channel is powered through the internal system rail, but it requires standard 120 Ohm termination resistors placed across the physical data lines at each endpoint of the physical network.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Socket Insertion:\u003c\/strong\u003e Align the module frame along the integrated chassis slots and push straight back into the M1 rack to mate the multi-pin backplane connector cleanly without bending pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Terminate all communication cable shields (Ethernet, CAN, RS-232) directly on the functional low-impedance grounding rail located at the cabinet entry bulkhead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Signal Paths:\u003c\/strong\u003e Route the low-voltage 24 VDC supply conductors and high-speed communication wiring through wire ducts isolated from high-voltage inductive lines and AC motor cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Envelope Maintenance:\u003c\/strong\u003e Maintain a continuous physical boundary of at least 50 mm above and below the module housing to allow adequate air circulation across the chassis vent slots.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431357907034,"sku":"MPC240\/W","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/292._55d5c829-67d9-4290-a33b-5827ffe7e3d2.jpg?v=1780022048"},{"product_id":"swi205-bachmann-digital-input-output-module-new-original-stock","title":"SWI205 Bachmann Digital Input\/Output Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann SWI205 M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann SWI205\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSWI205\u003c\/strong\u003e Digital Input\/Output Module, operates as a dedicated hardware component for configurable on\/off signal interfacing within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSWI205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 100 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels (individually configurable as input or output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e15-30 VDC (24 VDC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e 7 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between channels and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail \/ M1 base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe module transmits bi-directional binary states over internal high-velocity backplane bus communication pathways, preventing cycle jitter between the physical field connections and the main processor node. Configurable configuration matrices permit distinct channels to cycle as either 24 VDC sinks or 0.5 A sourcing switches, adjusting local I\/O density scaling profiles inside a single slot partition. The embedded field-programmable logic blocks maintain permanent firmware flash compatibility with standard M1 controller series platforms, tracking input transitions and forcing execution commands under tight deterministic network constraints.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal bus logic react during a concurrent module configuration or firmware flash sequence?\u003c\/p\u003e\n\u003cp\u003eA: During a firmware flash or initialization sequence, the backplane bus interface isolates the hardware execution layer, driving all 16 configurable output points to a high-impedance state until the master processing module confirms the register matrix map.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current constraints concerning hot-swap operation for this digital module?\u003c\/p\u003e\n\u003cp\u003eA: This module does not support hot-swapping. Unseating or inserting the module while the M1 backplane bus is energized can result in voltage transients that corrupt system bus communication velocity licenses or damage internal optical isolators.\u003c\/p\u003e\n\u003cp\u003eQ: Can channels configured as outputs safely handle inductive solenoid valve loads without external clamping diodes?\u003c\/p\u003e\n\u003cp\u003eA: While the 24 VDC outputs manage up to 0.5 A per channel, external inductive loads require flywheel diode suppression loops installed directly at the field device to eliminate inductive voltage spikes from entering the terminal block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Engagement Verification:\u003c\/strong\u003e Slide the module housing carefully into the physical M1 base unit slot guides, seating the multi-pin connector into the backplane bus assembly prior to energizing the power rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Connect all external digital input and output signal cable shields to the functional earth terminal rail at the cabinet interface point using low-impedance ground clamps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Conductor Isolation:\u003c\/strong\u003e Route all low-voltage 24 VDC discrete lines in wire ducts segregated from 400 VAC supply tracks and high-frequency variable speed drive motor conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screws Retaining Torque:\u003c\/strong\u003e Verify that all field terminal screws are tensioned to standard industrial values to prevent contact resistance failures under continuous physical vibration profiles.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431359152218,"sku":"SWI205","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/293.1_eef882ee-fcf4-449b-aa2b-a8a1e6617e95.jpg?v=1780022414"},{"product_id":"ai204-2-bachmann-analog-input-module-new-original-stock","title":"AI204\/2 Bachmann Analog Input Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann AI204\/2 M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann AI204\/2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAI204\/2\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for high-resolution analog signal acquisition within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI204\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg (packaged) \/  0.5 kg (net)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage (+\/-10 V), Current (0-20 mA \/ 4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% FS typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 1 kHz per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between channels and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe hardware subsystem routes digitized telemetry packets across internal high-velocity backplane bus communication pathways directly to the processing stack, suppressing cycle execution jitter. The integrated 16-bit analog-to-digital converter sub-circuits process concurrent sampling profiles across the voltage and current loops up to 1 kHz per channel without dropping frames. This bus coupling architecture facilitates flexible I\/O density scaling options within the M1 rack configuration while ensuring permanent firmware flash compatibility with master controller runtimes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the continuous electrical isolation limits when mapping concurrent voltage and current loops?\u003c\/p\u003e\n\u003cp\u003eA: The onboard galvanic isolation circuitry completely separates the 4 analog input channels from the logic planes of the internal system bus to prevent common-mode voltage spikes from disrupting backplane bus operations.\u003c\/p\u003e\n\u003cp\u003eQ: How does a running firmware flash sequence on the M1 controller affect the channel inputs?\u003c\/p\u003e\n\u003cp\u003eA: During a firmware flash, the module enters a passive hardware holding pattern. The A\/D converter suspends backplane bus data transmission, and the master CPU flags input variables as invalid until the software boot sequence registers the hardware profile.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of supporting active hot-swap insertion within the backplane rack?\u003c\/p\u003e\n\u003cp\u003eA: No. Hot-swapping is not supported on this platform. The M1 base unit assembly must be completely de-energized before mounting or unseating the hardware module to prevent terminal latch-up or damage to the backplane communication pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Guide Rail Alignment:\u003c\/strong\u003e Align the module frame precisely with the physical slots of the M1 base unit and seat firmly to connect with the high-velocity backplane socket before routing field power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Connect all external analog current loop and voltage cable shields directly to the low-impedance functional earth grounding rail at the control cabinet entry bulkhead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Segregation:\u003c\/strong\u003e Route all low-level 4-20 mA and +\/-10 V field sensor wiring within dedicated ducts separated from high-voltage AC motor lines or inductive contactor switches to suppress electromagnetic cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Retaining Calibration:\u003c\/strong\u003e Tighten all field terminal wire connections to standard factory torque ratings to maintain stable contact electrical continuity under conditions of constant industrial vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431364591706,"sku":"AI204\/2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/294_e69ece3d-02ea-4ebf-865e-55bb86a0b139.jpg?v=1780022820"},{"product_id":"bs208-bachmann-8-slot-base-rack-new-original-stock","title":"BS208 Bachmann 8-Slot Base Rack | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann BS208 M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann BS208\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBS208\u003c\/strong\u003e Base Rack, operates as a dedicated hardware component for module mounting and bus distribution within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBS208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e438 mm x 121 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (system backplane dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003e8 module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eHigh-strength aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Matrix\u003c\/td\u003e\n\u003ctd\u003ePassive convection cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe chassis frame routes power rails and processing lines across a passive structure to interconnect up to 8 slots without active semiconductor nodes. This layout enables real-time synchronization between the master processor card and adjacent modules by running data paths through standard high-velocity backplane bus communication pathways. The architecture maintains direct physical and electrical properties required for full firmware flash compatibility across attached components, allowing field engineers to scale I\/O density configurations while preserving deterministic network timing tolerances under continuous vibration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the passive backplane bus handle high-density module insertion during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: The passive architecture lacks isolated live-insertion sub-circuits. The main power supply feed to the backplane rack must be completely de-energized before unseating or adding components to prevent signal line corruption or electrical arcing across the bus pins.\u003c\/p\u003e\n\u003cp\u003eQ: What are the current capacity limits for the internal backplane bus lines when filling all 8 slots?\u003c\/p\u003e\n\u003cp\u003eA: The structural copper bus tracks are optimized to handle standard continuous M1 module load matrices. Total power consumption from the coupled CPU and I\/O modules must be validated against the maximum rating of the installed power supply module to prevent localized voltage drops.\u003c\/p\u003e\n\u003cp\u003eQ: Does the physical backplane assembly require independent firmware flash upgrades to maintain compatibility?\u003c\/p\u003e\n\u003cp\u003eA: No. The backplane operates as a completely passive mechanical and electrical routing interface. It contains no onboard microprocessors, meaning it is immune to firmware conflicts and maintains permanent hardware-level compatibility.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding Matrix:\u003c\/strong\u003e Connect the aluminum chassis body directly to the master control cabinet copper grounding bar using a low-impedance conductor to ensure adequate shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Alignment Execution:\u003c\/strong\u003e Slide each functional module precisely along the integrated physical guide tracks of the slot to ensure square engagement with the backplane pin sockets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting Stability:\u003c\/strong\u003e Verify that the rear tensioning springs lock securely onto the standard DIN rail structure to prevent mechanical shifting in high-vibration equipment environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvective Thermal Clearances:\u003c\/strong\u003e Maintain unobstructed boundaries above and below the rack assembly to support proper passive convection cooling across the internal heat dissipation pathways.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431375634522,"sku":"BS208","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/295._f252f683-74ca-4213-a479-a91d4ed1cf81.jpg?v=1780023164"},{"product_id":"gio212-bachmann-universal-input-output-module-new-original-stock","title":"GIO212 Bachmann Universal Input\/Output Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann GIO212 M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann GIO212\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eGIO212\u003c\/strong\u003e Universal Input\/Output Module, operates as a dedicated hardware component for multi-signal analog and digital interfacing within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGIO212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 100 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels (analog\/digital configurable input or output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Signal Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D and D\/A conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, 0\/4-20 mA, Pt100\/Pt1000, Thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC (15-30 VDC range), ~ 7 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 0.5 A per channel max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between channels and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe universal interface module utilizes embedded parameter registers to adjust electrical execution paths on a per-channel basis, adapting local I\/O density scaling profiles without modifying the physical footprint of the backplane sub-assembly. Internal high-velocity backplane bus communication pathways facilitate the transmission of high-resolution 16-bit analog conversions, 32-bit counter metrics, and fast binary transitions directly to the runtime engine kernel. This software-defined routing mechanism maintains strict hardware timing tolerances while ensuring permanent firmware flash compatibility with the primary M1 processor platform during active operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal backplane logic respond when changing channel parameters between analog and digital functions?\u003c\/p\u003e\n\u003cp\u003eA: Channel configuration matrices are locked during the initial controller boot sequence via the system configuration files. Modifying channel assignments requires a complete restart of the M1 rack to upload new hardware profiles over the backplane bus communication interface.\u003c\/p\u003e\n\u003cp\u003eQ: Is this universal hardware component hot-swappable on an energized M1 base unit?\u003c\/p\u003e\n\u003cp\u003eA: No. The backplane design does not support active hot-swap functionality. Power to the M1 base rack must be isolated prior to removing or seating the module to protect the internal optical isolation components from transient voltage damage.\u003c\/p\u003e\n\u003cp\u003eQ: What buffering capacity is available for high-speed digital counter or period measurement operations?\u003c\/p\u003e\n\u003cp\u003eA: The module contains an integrated physical hardware FIFO buffer capable of storing up to 1022 timed values for pulse length and period measurements, insulating the data from backplane bus communication latencies.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Socket Alignment:\u003c\/strong\u003e Insert the module housing straight into the M1 base unit guide channels, applying even pressure until the multi-pin rear connector is fully seated into the passive backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Clamp all analog instrumentation and high-speed digital signal cable shields to the low-impedance master cabinet ground bus at the physical entry partition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Type Segregation:\u003c\/strong\u003e Maintain separate physical wiring paths for 24 VDC digital actuation loops, low-level RTD\/thermocouple signals, and adjacent high-voltage power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Boundary Clearances:\u003c\/strong\u003e Verify a minimum vertical gap of 50 mm above and below the module ventilation openings to permit unobstructed convection airflow through the assembly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431388414042,"sku":"GIO212","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/296_6200bf33-6a9f-4ba0-8b3b-d70fa3b16dcf.jpg?v=1780023454"}],"url":"https:\/\/www.spareoil.com\/collections\/bachmann.oembed?page=5","provider":"SpareOil Automation","version":"1.0","type":"link"}