{"title":"Bently Nevada 3300 Series","description":"\u003cp\u003eThe Bently Nevada 3300 series remains a reliable pillar of machinery protection. This collection features original rack-mounted monitors, power supplies, and interface modules for the 3300 system. Whether you are maintaining legacy 3300\/10 or 3300\/12 components, we provide 100% genuine, tested parts to extend the life of your proven monitoring infrastructure.\u003c\/p\u003e","products":[{"product_id":"3300-20-13-03-01-00-00-bently-nevada-dual-thrust-position","title":"3300\/20-13-03-01-00-00 | Bently Nevada | Dual Thrust Position","description":"\u003ch3\u003e\u003cstrong\u003eBently Nevada 3300\/20-13-03-01-00-00 Axial Position Dual Thrust Monitor\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/20-13-03-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision Dual Thrust Position Monitor belonging to the Bently Nevada 3300 Series machinery protection system. This module is specifically engineered for the continuous tracking of a rotating shaft's axial (thrust) position. By interfacing with Bently Nevada proximity transducer systems—such as the 3300 XL 8 mm probes—the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides critical data to prevent catastrophic machinery failure caused by excessive axial movement. This specific configuration features a layered protection strategy with three integrated relays and a flexible recorder output, making it a cornerstone for safety-critical monitoring in turbines, compressors, and high-speed pumps.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/20-13-03-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers high-resolution measurement with industrial-grade fail-safe features.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/20-13-03-01-00-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor Type\u003c\/strong\u003e: Dual Thrust Position Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 2 Independent Thrust Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e: Bently Nevada Proximity Probes (e.g., 7200, 3300, 3300 XL series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Typically ±2.0 mm to ±5.0 mm (probe dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e: 3 Relays total (1 Alert, 2 Danger)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Terminal Type\u003c\/strong\u003e: D-type terminal interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e: Configurable 4–20 mA current or 0–10 VDC voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 5.5 Watts (Typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: Rack-mounted in standard Bently Nevada 3300 Series enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to +60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE, UL, CSA compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Performance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Channel Redundancy\u003c\/strong\u003e: The module monitors two independent channels, allowing for voting logic or redundant probe placement to eliminate false trips while ensuring absolute protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLayered Alarm Protection\u003c\/strong\u003e: Equipped with three physical relays, the module provides a multi-stage safety response: one Alert relay for early warning and two Danger relays for emergency shutdown triggers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Data Acquisition\u003c\/strong\u003e: Integrated recorder outputs can be configured by the user to provide either proportional voltage or current signals, facilitating easy connection to external PLC, DCS, or SCADA systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration and EMI Resistance\u003c\/strong\u003e: Built with a rugged aluminum faceplate and high-quality internal shielding, the monitor maintains accuracy in high-vibration and electrically noisy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Self-Diagnostics\u003c\/strong\u003e: The monitor constantly performs internal self-tests to ensure the integrity of the proximity probe circuit and the module's own logic processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870828433498,"sku":"3300\/20-13-03-01-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/73._a7de930e-15c7-4de2-b651-387984965ade.jpg?v=1770946143"},{"product_id":"bently-nevada-3300-10-02-02-00-vibration-monitoring-power","title":"Bently Nevada 3300\/10-02-02-00 Vibration Monitoring Power","description":"\u003ch3\u003e\u003cstrong\u003eBently Nevada 3300\/10-02-02-00 3300 Series Rack Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Power Supply Module engineered to deliver stabilized DC power to the Bently Nevada 3300 Series machinery protection and condition monitoring system. Functioning as the primary energy hub for the rack, it converts standard AC line voltage into the regulated DC rails required by up to 12 monitoring modules and their associated transducers (supporting up to 36 channels total). Designed for mission-critical turbomachinery applications, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports dual-redundant configurations, ensuring that a single power supply failure does not compromise the vibration monitoring of essential assets like turbines, compressors, and large motors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to exacting industrial standards, featuring EMI shielding and passive cooling for long-term durability.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: 3300 Vibration Monitoring System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 115 VAC (95–125 VAC) or 230 VAC (190–250 VAC), 47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e: Regulated DC output for rack-wide distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e: Powers up to 12 monitors and 36 transducers per rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e: Supports 1:1 power supply redundancy for fault tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e: Passive convection cooling (fanless design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e: Aluminum alloy with integrated EMI shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to +60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: Up to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.8 kg (1.76 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 16 cm × 16 cm × 12 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE, UL, CSA compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870828466266,"sku":"3300\/10-02-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/72.1_d889be97-269c-4f87-8831-954d10585e18.jpg?v=1770945984"},{"product_id":"3300-01-01-00-bently-nevada-machinery-protection-brain","title":"3300\/01-01-00 Bently Nevada Machinery Protection Brain","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 3300\/01-01-00 occupies the critical first slot (leftmost position) of the 3300 Machinery Protection System rack. This module functions as the administrative supervisor, continuously monitoring the health of the rack power supply and the operational status of all installed modules. It acts as the primary diagnostic interface, ensuring that the protection system itself remains fault-free while monitoring high-value rotating assets. By managing system-wide resets and power-up inhibits, the 3300\/01-01-00 prevents false trips during machine startup and provides clear, immediate visual confirmation of system integrity through its front-panel LED array.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3300\/01\u003c\/strong\u003e: System Monitor Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01\u003c\/strong\u003e: Power-up Inhibit Option (Enabled).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Agency Approval Option (None\/Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProfessional Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300\/01-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3300 Series Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 Watts (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFront Panel LEDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupply OK (+5V, -24V, +V, -V), Rack OK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Reset Pushbutton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInhibit Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower-up Inhibit \/ System Reset\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 °C to +65 °C (-4 °F to +149 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Position\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePosition 1 (Leftmost Slot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAPI 670 Standard for Machinery Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (Net Module Weight: 0.8 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/01-01-00 resolves critical system-level reliability challenges in industrial monitoring:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentralized Health Supervision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module monitors all internal DC rail voltages (+5V, -24V, +V, and -V). If any power rail fluctuates outside of tolerance, the \"Rack OK\" relay de-energizes, alerting operators that the protection system's reliability is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrevention of Startup Nuisance Trips:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated Power-up Inhibit function suppresses alarm outputs for a set duration during system startup. This allows transducer signals and internal circuitry to stabilize, ensuring that the turbine or compressor does not trip due to transient power-up noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnified System Reset:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA single front-panel pushbutton allows technicians to clear latched alarms across the entire rack simultaneously. This streamlines post-fault diagnostics and simplifies the return-to-service protocol for the machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Determinism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to meet rigorous API 670 standards, the hardware prioritizes the \"OK\" status logic. It ensures that any internal failure within the monitoring rack triggers a system-wide alert rather than allowing the machine to run unprotected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Bently Nevada 3300\/01-01-00 brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the 3300\/01-01-00 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition. Each module arrives in original factory packaging, providing a reliable spare part solution for legacy 3300 series installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the 3300\/01 in any slot in the 3300 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 3300\/01-01-00 must occupy the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eleftmost slot (Position 1)\u003c\/strong\u003e. This position allows the module to interface directly with the rack power supply and the common backplane traces used for system-wide communication and resets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the \"Rack OK\" LED turns off?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the \"Rack OK\" LED extinguishes, the module has detected an internal fault, such as a power supply failure or a self-test error in one of the monitoring cards. This state typically triggers a contact closure to the plant DCS to indicate that the machinery protection system is currently unreliable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require software configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300\/01-01-00 is a hardware-configured module. While the 3300 series has a static architecture compared to the software-driven 3500 series, you must ensure that any onboard jumpers or option switches match your specific rack's power-up and reset requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42912159629402,"sku":"3300\/01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/230.jpg?v=1776760370"},{"product_id":"3300-03-01-00-bently-nevada-keyphasor-interface-new-original-stock","title":"3300\/03-01-00 Bently Nevada Keyphasor Interface | New \u0026 Original Stock","description":"\u003ch2\u003eBently Nevada 3300\/03-01-00 3300 Series System Monitor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/03-01-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3300\/03\u003c\/strong\u003e System Monitor \/ Keyphasor Interface, serves as the primary \u003cstrong\u003e3300\/03\u003c\/strong\u003e System Monitor utilized to execute synchronized timing signals and serial data communication across 3300 Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSystem Monitor \/ Keyphasor Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 24 VDC (Via rack backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 Watts Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eRS232 Serial Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input\u003c\/td\u003e\n\u003ctd\u003eKeyphasor Proximity Probe Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e33.0 cm x 5.1 cm x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation and Eddy-Current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/03-01-00 processes input thresholds from proximity transducers configured for eddy-current probe scaling to ensure precise phase-synchronous tracking. Field instrumentation routines require strict gap voltage validation, targeting a nominal -10 VDC baseline from the proximity sensor to place the physical measurement within the linear domain of the transducer calibration curve. Correct scaling prevents cross-talk suppression failures and signal clipping across the internal backplane bus, allowing downstream rack instruments to accurately extract 1X vibration amplitude, phase angle matrices, and transient rotor dynamics parameters without data distortion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What action does the 3300\/03-01-00 execute if the field-side Keyphasor proximity probe signal undergoes an open-circuit or short-circuit event?\u003c\/p\u003e\n\u003cp\u003eA: The module checks signal integrity parameters continuously. If the transducer voltage exits the pre-defined linear range, the internal logic drops the front-panel OK LED status and flags a system fault across the backplane to prevent invalid speed data calculation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 3300\/03-01-00 interface module be hot-swapped while the 3300 machinery protection rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Removing or inserting the primary system monitor while the backplane is live interrupts the serial data backbone and common timing references, which can destabilize adjacent monitoring cards and cause unintended machine trip signals.\u003c\/p\u003e\n\u003cp\u003eQ: How is the RS232 serial communication interface utilized for machinery diagnostics?\u003c\/p\u003e\n\u003cp\u003eA: The integrated physical RS232 connection outputs raw and processed diagnostic data arrays directly from the backplane architecture to external host computers running automated machinery management and analysis platforms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Alignment and Locking Precision:\u003c\/strong\u003e Slide the module package vertically along the chassis guide rails until the rear edge connectors seat completely with the backplane terminal matrix. Tighten the front panel screws securely to resist the effects of structural industrial machinery vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Cable Isolation and Shielding:\u003c\/strong\u003e Route all incoming Keyphasor probe coaxial runs through independent, grounded steel conduits. Terminate the outer shield wire at a single point on the main rack earth bar to block electromagnetic fields from injecting noise into the speed measurement loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximity Sensor Gap Voltage Adjustment:\u003c\/strong\u003e Set the physical distance between the probe tip and the target shaft until a digital voltmeter registers a gap voltage validation value of -10 VDC during zero-speed shaft positioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS232 Data Line Length Thresholds:\u003c\/strong\u003e Limit the physical deployment distance of the unshielded RS232 serial interface cable to a maximum of 15 meters to prevent signal attenuation and frame transmission errors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42912234373210,"sku":"3300\/03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/231.jpg?v=1770776724"},{"product_id":"bently-nevada-3300-05-22-00-00-3300-series-protection-rack-chassis","title":"Bently Nevada 3300\/05-22-00-00 3300 Series Protection Rack Chassis","description":"\u003ch2\u003eBently Nevada 3300\/05-22-00-00 3300 Series Machinery Protection Rack\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3300\/05-22-00-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3300\/05\u003c\/strong\u003e Machinery Protection Rack, operates as a dedicated hardware component for housing monitoring modules and distributing system power within 3300 series protection networks. It accepts standard 3300 series monitor cards, transmitting raw proximity sensor signals and processed vibration metrics across a central backplane bus. The unit provides structural alignment, backplane grounding, and power routing to manage continuous dynamic vibration, axial position, and speed monitoring across rotating machinery loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode \/ Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDesignation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3300\/05\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e6-Slot Machinery Protection Rack chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-22\u003c\/td\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e19-inch EIA rack mount configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eStandard power supply and interface bus backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eStandard unapproved or basic commercial build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/05-22-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 x 267 x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on module load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eMachinery Protection Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e6 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e19-inch EIA rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMachinery Protection and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/05 rack provides the mechanical housing and passive backplane required for complex rotor dynamics analysis. Bently Nevada engineers design these racks to maintain exact tolerances for eddy-current probe scaling, ensuring that proximity sensor signals remain linear across the transducer's measurement range. Furthermore, the rack incorporates shielding to facilitate cross-talk suppression between high-density modules. This separation prevents signal interference when monitoring multiple vibration vectors on high-speed rotating shafts. Additionally, the system monitor position in slot 2 performs constant gap voltage validation against -10 VDC targets to confirm probe health before triggering protection logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 3300\/05 rack support module hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: You may insert or remove monitoring modules while the rack remains powered. However, you must ensure the system monitor module remains seated to maintain constant rack-level diagnostic scanning and alarm communication.\u003c\/p\u003e\n\u003cp\u003eQ: What are the grounding requirements for the 3300 rack?\u003c\/p\u003e\n\u003cp\u003eA: You must connect the rack chassis to the cabinet protective earth (PE) bus using a low-impedance conductor. Proper grounding prevents ground loops, which introduce DC offsets into the proximity probe signals.\u003c\/p\u003e\n\u003cp\u003eQ: Which slot must the system power supply module occupy?\u003c\/p\u003e\n\u003cp\u003eA: Install the system power supply into slot 1 to achieve balanced power distribution across the internal backplane traces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSecure the rack into the 19-inch cabinet frame using the dedicated mounting flange screw holes. Verify the chassis sits level to ensure consistent edge-connector alignment along the backplane assembly.\u003c\/p\u003e\n\u003cp\u003eInspect backplane connectors for proper pin orientation prior to seating individual monitoring cards. Avoid applying excessive force during module insertion to protect the gold-plated contact fingers from mechanical damage. Connect the primary rack frame directly to the cabinet protective earth bus using a short, heavy-gauge grounding strap. Verify supply voltage levels from the main power module before energizing installed monitor channels, and perform gap voltage validation with a digital voltmeter at the rear field wiring terminals to confirm probe bias falls within nominal operating limits.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057199513690,"sku":"3300\/05-22-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/298.jpg?v=1773622863"},{"product_id":"bently-nevada-145193-01-330180-x1-05-3300-xl-proximitor-sensor","title":"Bently Nevada 145193-01 330180-X1-05 3300 XL Proximitor Sensor","description":"\u003ch2\u003eBently Nevada 145193-01 3300 XL 8mm Proximitor Sensor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 145193-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3300 XL 8mm\u003c\/strong\u003e Proximitor Sensor (Model \u003cstrong\u003e330180-X1-05\u003c\/strong\u003e), operates as a dedicated hardware component for converting shaft gap distance into proportional analog voltage within 3500 Series Machinery Protection System platforms. It accepts input signals from 3300 XL 8mm proximity probes and conditions the dynamic raw voltage to output a calibrated linear signal of 7.87 V\/mm (200 mV\/mil). This module provides direct physical interface execution for tracking radial vibration, axial thrust position, and Keyphasor speed signals across rotating shaft machinery.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe part number sequence defines the factory electrical calibration and system length parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330180\u003c\/strong\u003e: Base model designation for the 3300 XL 8mm Proximitor Sensor series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eX1\u003c\/strong\u003e: High-accuracy performance specification option for target displacement tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Factory calibration option for a 5.0-meter total system length (Probe + Extension Cable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMOD 145193-01\u003c\/strong\u003e: Internal modification specification code ensuring standardized sensitivity for 8mm proximity probe systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330180-X1-05 (MOD 145193-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81.3 mm x 61.2 mm x 63.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupply voltage requirement -17.5 VDC to -26 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting at 0.25 mm (10 mils) gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz (DC) to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 Meters total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25% of full-scale range at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAPI 670 machinery protection standard compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Gap Voltage Validation Parameters\u003c\/h3\u003e\n\u003cp\u003eThe 330180-X1-05 MOD 145193-01 conditions high-frequency field signals generated by eddy-current field interaction with rotating targets. Accurate displacement tracking depends on standard eddy-current probe scaling tuned to AISI 4140 steel target material. During installation and routine maintenance, technicians execute gap voltage validation (-10 VDC targets corresponding to the center of the 2.0 mm linear range) to set the physical baseline before connecting the analog output to monitoring racks. The sensor housing incorporates cross-talk suppression and radio frequency interference (RFI) rejection circuitry to prevent signal distortion when routing cables near motor control equipment, maintaining phase timing accuracy for tracking rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What occurs if field personnel pair the 145193-01 sensor with a 9.0-meter probe and cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: Pairing this unit with a 9.0-meter system length introduces major calibration errors and non-linear signal responses, as the internal LC oscillator tank circuit is tuned exclusively for 5.0-meter electrical lengths.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 145193-01 Proximitor mount directly on a standard 35mm DIN rail?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the housing includes integral mounting features that accept standard 35mm DIN-rail hardware or direct panel-mounting screws.\u003c\/p\u003e\n\u003cp\u003eQ: How does a non-4140 steel shaft alloy affect the output signal of the 145193-01 sensor?\u003c\/p\u003e\n\u003cp\u003eA: Target materials with different magnetic permeability alter the output sensitivity scale factor from the standard 200 mV\/mil, requiring custom software scaling factors inside the 3500 monitoring system configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the Bently Nevada 145193-01 3300 XL Proximitor Sensor in industrial enclosures, observe the following physical guidelines:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMount the sensor chassis onto a grounded 35mm DIN rail or panel plate inside an IP65\/NEMA 4X weather-proof enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify physical isolation between the sensor housing and adjacent metal components to prevent parasitic electrical grounding paths.\u003c\/li\u003e\n\u003cli\u003eConnect the coaxial extension cable from the proximity probe, hand-tightening the ClickLoc connectors until the tactile click engages.\u003c\/li\u003e\n\u003cli\u003eInsulate coaxial cable connector unions using silicone self-fusing tape or field connector protectors to block moisture entry.\u003c\/li\u003e\n\u003cli\u003eWire the terminal strip using three-conductor shielded cable (-24 VDC Power, Signal Output, Common Return), landing the shield at the single-point ground bus within the monitor rack panel.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43092355842138,"sku":"145193-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/291_dafe52fd-9295-4eaf-997a-8a2569dbe55f.jpg?v=1774250308"},{"product_id":"bently-nevada-3300-14-dual-dc-power-supply-3300-14-01-22-02","title":"Bently Nevada 3300\/14 Dual DC Power Supply 3300\/14-01-22-02","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/14-01-22-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the high-integrity power core for the 3300 Series Machinery Protection System. This module converts raw input power into the stable, regulated DC rails required to drive proximity probes, vibration sensors, and monitoring cards. It supports continuous, online machinery diagnostics by providing noise-free energy to critical protection loops. We supply this module in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original condition\u003c\/strong\u003e, ensuring your mission-critical assets remain protected by authentic factory hardware.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: 3300\/14-AA-BB-CC\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/14 series utilizes specific codes to define power requirements and safety ratings:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01 (AA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Power Supply (converted to system DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e22 (BB)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecific Voltage Output Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02 (CC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-agency safety and environmental certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/14-01-22-02 features a ruggedized electrical design to maintain output stability despite fluctuations in factory mains.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Mains (Universal Internal Conversion)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated DC for 3300 System Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAPI 670 Machinery Protection Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.1 kg (4 lbs 9.3 oz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 3300 Series Rack Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.1 cm x 20.3 cm (Front Panel Width x Height)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Standardized Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module adheres to the American Petroleum Institute (API) 670 standard, ensuring it meets the rigorous reliability and response requirements for oil \u0026amp; gas and petrochemical applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3300\/14 architecture supports dual-supply configurations. This prevents system-wide monitoring failure if a single power source or module malfunctions, as the secondary unit maintains the full rack load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClean Signal Delivery:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrecision voltage regulation eliminates electrical noise that could otherwise cause \"false trips\" or inaccurate readings in high-sensitivity vibration and proximity probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada builds this chassis with corrosion-resistant materials and heavy-duty components designed for 24\/7 operation in high-temperature manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3300\/14-01-22-02 compatible with the newer 3500 Series racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module is specifically designed for the Bently Nevada 3300 Series. It utilizes a different form factor and backplane connector than the 3500 Series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 3300 system is robust, we recommend following the specific Bently Nevada maintenance manual procedures. In redundant configurations, one supply module can typically be replaced while the other maintains system power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the condition of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery unit we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand arrives in original factory packaging. We include a standard 12-month warranty to guarantee performance in your machinery protection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if this power supply fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA total power failure will de-energize your monitoring modules, potentially leading to an \"unprotected\" state for your rotating machinery. Using a dual-supply setup (redundancy) significantly mitigates this risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43242495443034,"sku":"3300\/14-01-22-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/491._c85248ad-915b-40cf-bdb4-8201538b9545.jpg?v=1776671488"},{"product_id":"bently-nevada-3300-35-temperature-monitor-relay-board-82368-01","title":"Bently Nevada 3300\/35 Temperature Monitor Relay Board 82368-01","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 82368-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(often identified by PWA 79532-01) is a versatile\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSignal Relay Board and 3-Wire RTD Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitoring system. This module serves two critical functions: it acts as a hardware interface for 3-wire Resistance Temperature Detectors (RTDs) and provides physical relay outputs for alarm annunciation. By integrating with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/35 Six-Channel Temperature Monitor\u003c\/strong\u003e, the 82368-01 converts thermal resistance data into actionable protective logic, triggering external horns, lights, or automatic machinery shutdown sequences when bearing or process temperatures exceed safety limits.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 82368-01 features precision signal conditioning circuitry to maintain the accuracy of thermal measurements in high-interference industrial zones.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e82368-01 (PWA 79532-01)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Wire RTD (Platinum, Copper, or Nickel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Relay Board \/ RTD Terminal Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3300\/35 Temperature Monitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal conditioning and alarm relay triggering\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 kg (0.57 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRear-rack Terminal Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3-Wire Lead Wire Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 82368-01 utilizes a 3-wire input configuration specifically to solve the problem of lead-wire resistance. By measuring the resistance of the third wire, the module cancels out the error caused by long cable runs between the machinery bearing and the monitoring rack, ensuring 100% accurate temperature readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Alarm Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module facilitates direct communication between the temperature monitoring cards and the physical relay layer. It translates digital alarm states into mechanical contact closures, allowing for immediate integration with plant DCS or Emergency Shutdown (ESD) systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal circuitry filters out electromagnetic noise common in motor-driven environments. This prevents \"nuisance trips\" triggered by electrical transients, ensuring the 3300 system only reacts to genuine thermal anomalies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Purpose Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hybrid design allows this single part number to function as both a terminal interface for sensors and a control board for outputs. This reduces spare parts inventory complexity for facilities maintaining legacy Bently Nevada 3300 racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 82368-01 supplied as 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada hardware. Each unit ships in factory-sealed packaging and includes a 12-month factory warranty to ensure critical machinery protection reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module for vibration signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The 82368-01 is specifically engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3-wire RTD temperature inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand relay control. For vibration or displacement signals, you must use the appropriate 3300 series Proximitor® or Seismic terminal modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a specific 3300 monitor card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 82368-01 typically pairs with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/35 Six-Channel Temperature Monitor\u003c\/strong\u003e. Check your rack configuration to ensure the backplane slot supports the 3-wire RTD interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the PWA number 79532-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The PWA (Printed Wiring Assembly) number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e79532-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erefers to the internal board assembly, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e82368-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the complete module part number. These are often used interchangeably in industrial catalogs, but both refer to the same 3300 Series Signal Relay\/RTD Input Module.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43250317754458,"sku":"82368-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/354._6b7be25c-c7e9-426d-ad51-36ea213021c7.jpg?v=1776828786"},{"product_id":"3300-20-11-01-01-00-02-bently-nevada-dual-thrust-monito","title":"Bently Nevada 3300\/15-02-02-00-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/15 Dual Vibration Monitor is a rack-mounted module within the 3300 Series system, specifically engineered to measure and protect rotating machinery by continuously monitoring shaft vibration. This module provides two independent vibration channels, delivering both dynamic and proportional outputs for critical alarm and trip functions. It is widely deployed in industrial environments such as turbines, compressors, and pumps where precise, real-time vibration detection is essential for operational reliability and safety.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel vibration monitoring for independent signal processing.\u003c\/li\u003e\n\u003cli\u003eDynamic and proportional outputs for comprehensive machinery analysis.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm setpoints.\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration into the 3300 Series rack architecture.\u003c\/li\u003e\n\u003cli\u003eStandard configuration for proximity probe transducer inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating compressor protection.\u003c\/li\u003e\n\u003cli\u003eLarge pump and motor vibration analysis.\u003c\/li\u003e\n\u003cli\u003eCritical rotating equipment safety and trip systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/15-02-02-00-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Proximity probe channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic signals, 4-20 mA proportional, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 Series rack is properly grounded before installing the module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD (Electrostatic Discharge) protection practices.\u003c\/li\u003e\n\u003cli\u003eVerify that the rack power is disconnected before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure all signal wiring is routed away from high-voltage or high-EMI sources to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eConfirm that the transducer input configuration matches the installed proximity probes before system commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/15 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/15 is a dual-channel vibration monitor designed to process signals from proximity probes to provide continuous monitoring and alarm\/trip protection for rotating machinery.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing 3300 Series racks?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/15 is designed specifically for the 3300 Series rack system and is intended to be installed in standard rack slots.\u003c\/p\u003e\u003ch3\u003eDoes this module require external barriers?\u003c\/h3\u003e\u003cp\u003eThe specific order code 3300\/15-02-02-00-00-00-00 indicates a standard input barrier configuration without intrinsic safety barriers. Consult your site safety requirements if intrinsic safety is required for your installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43840558006362,"sku":"3300\/15-02-02-00-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_cecd62e0-767d-4d03-83d0-e5386b8e7adb.jpg?v=1786640562"},{"product_id":"bently-nevada-3300-40-13-01-01-00-00-eccentricity-monitor-module-1","title":"Bently Nevada 3300\/03-02-01 System Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/03 System Monitor is a rack-mounted supervisory module engineered to oversee the operational health and status of all monitoring modules within a 3300 series rack system. It serves as the central hub for diagnostics, alarm coordination, and communication, ensuring the integrity of machinery protection systems for critical assets such as turbines and compressors.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCentralized supervision of all monitoring modules installed within the 3300 rack.\u003c\/li\u003e\n\u003cli\u003eCoordinates OK, Bypass, Alert, and Danger relay logic for system-wide integrity.\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring of rack power supply voltages and internal communication bus status.\u003c\/li\u003e\n\u003cli\u003eProvides interface capabilities for external control systems to receive alarm and status signaling.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for real-time rack and module health diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is essential for critical rotating machinery protection, including steam and gas turbines, centrifugal compressors, and large-scale industrial pumps where centralized rack management is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/03-02-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the System Monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated rack slot, ensuring the backplane connector is properly aligned and seated.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is securely fastened using the front panel captive screws to maintain proper grounding and vibration resistance.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to protect internal circuitry from electrostatic discharge.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the rack to maintain the operating temperature within the 0 to 60 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/03 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/03 acts as the master supervisory module for the 3300 rack, managing communication, alarm relay coordination, and power supply monitoring for all other modules in the rack.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other 3300 series components?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/03 is specifically designed for integration within the Bently Nevada 3300 series rack architecture.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43847277772890,"sku":"3300\/03-02-01","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_49d1adc7-c0c7-4362-b0b2-5a5fc7be3cc1.jpg?v=1786724512"},{"product_id":"bently-nevada-3300-20-12-01-01-00-00-dual-thrust-monitor-1","title":"Bently Nevada 3300\/16-02-05-02-00-00-02 Dual Vibration XY\/GAP Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/16 Dual Vibration XY\/GAP Monitor is a rack-mounted module within the 3300 Series monitoring system. It is engineered to provide simultaneous measurement of radial shaft vibration (XY) and probe gap voltage. This dual-channel monitoring capability is essential for the protection of critical rotating machinery, including turbines, compressors, and pumps, by facilitating the early detection of mechanical issues such as bearing wear, shaft misalignment, and rotor rubs.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel configuration for simultaneous XY vibration and gap monitoring.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard proximity probe (Proximitor) transducer inputs.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm conditions.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA outputs for integration with external control or data acquisition systems.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED status indicators for OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eContinuous signal processing and comparison against configurable alarm setpoints.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis monitor is designed for use in industrial environments where continuous vibration monitoring is required for rotating equipment. It is commonly deployed in power generation, petrochemical processing, and oil and gas facilities to ensure machinery health and prevent catastrophic failure.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-02-05-02-00-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Proximity probe channels (XY and GAP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic signals, 4-20 mA, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is properly grounded before installing the module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD (Electrostatic Discharge) protection practices.\u003c\/li\u003e\n\u003cli\u003ePower down the rack or ensure the slot is bypassed before inserting or removing the monitor module to prevent electrical damage or unintended alarm trips.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring for proximity probes is shielded and routed away from high-voltage or high-EMI sources to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation in the rack cabinet to maintain ambient temperatures within the specified operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 3300\/16 monitor measure?\u003c\/h3\u003e\u003cp\u003eThe 3300\/16 is designed to measure radial shaft vibration (XY) and probe gap voltage simultaneously, providing critical data for monitoring the mechanical condition of rotating shafts.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with standard proximity probes?\u003c\/h3\u003e\u003cp\u003eYes, this specific model (order code 02 for transducer input) is configured to interface directly with standard Bently Nevada proximity probe systems.\u003c\/p\u003e\u003ch3\u003eWhat do the relay outputs indicate?\u003c\/h3\u003e\u003cp\u003eThe relay outputs are configured to trigger based on Alert and Danger alarm setpoints, allowing the system to initiate automated shutdowns or operator notifications when vibration levels exceed safe thresholds.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43847285342298,"sku":"3300\/16-02-05-02-00-00-02","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_b2abc2a6-39bd-46fe-9ff5-d91e507a33c7.jpg?v=1786724719"},{"product_id":"bently-nevada-991-01-xx-01-00-vibration-transmitter","title":"Bently Nevada 3300\/20-01-01-02-01-00 Dual Thrust Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/20 Dual Thrust Monitor is a specialized monitoring module designed for the 3300 series system. It provides continuous monitoring of axial shaft position (thrust) in rotating machinery, ensuring critical protection by comparing the measured position against user-programmed alarm setpoints. This monitor is engineered to process signals from proximity transducers to detect excessive axial movement, which is essential for preventing catastrophic equipment failure.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel monitoring capability for redundancy or multi-point axial measurement.\u003c\/li\u003e\n\u003cli\u003eCompatible with 7200 series proximity transducer systems.\u003c\/li\u003e\n\u003cli\u003eIntegrated 4-20 mA recorder output for external data logging and trending.\u003c\/li\u003e\n\u003cli\u003eConfigurable alarm setpoints for Danger and Alert conditions.\u003c\/li\u003e\n\u003cli\u003eDesigned for integration into the standard Bently Nevada 3300 rack system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e3300\/20-01-01-02-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e7200 200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale Range\u003c\/td\u003e\n\u003ctd\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e0 to -10 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.7 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Power Supply\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is properly grounded according to site electrical standards to prevent noise interference.\u003c\/li\u003e\n\u003cli\u003eAlways power down the rack before inserting or removing the monitor module to prevent electrical arcing or damage to the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for transducer inputs to minimize EMI\/RFI susceptibility.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the 3300 rack to ensure ambient temperatures remain within the 0 to +65 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eVerify that the transducer power supply settings match the requirements of the installed proximity probes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/20 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/20 is designed to monitor the axial position of a machine shaft, providing critical protection by triggering alarms or trips if the shaft position exceeds safe operating limits.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other Bently Nevada systems?\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for the Bently Nevada 3300 series monitoring system. It is not directly interchangeable with 3500 series modules.\u003c\/p\u003e\u003ch3\u003eWhat does the 4-20 mA output provide?\u003c\/h3\u003e\u003cp\u003eThe 4-20 mA output provides a proportional signal representing the measured thrust position, which can be sent to a PLC, DCS, or external data acquisition system for remote monitoring.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43854795145306,"sku":"3300\/20-01-01-02-01-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_d543239e-ed3a-407b-8897-30dc518c28a9.jpg?v=1786904192"},{"product_id":"bently-nevada-3300-55-01-01-02-02-00-00-03-00-dual-velocity-monitor","title":"Bently Nevada 3300\/55-01-04-18-18-00-00-05-00 Dual Velocity Monitor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a rack-mounted module engineered for the 3300 Monitoring System. It is designed to measure casing vibration velocity by interfacing with Velomitor piezo-velocity sensors. The module provides two independent channels of continuous vibration monitoring, comparing input signals against user-defined Alert and Danger setpoints to ensure the protection of critical rotating machinery such as turbines, compressors, motors, and pumps.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel velocity monitoring for high-density rack configurations.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Velomitor piezo-velocity sensor inputs.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic with Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eDual relay outputs for automated machinery protection and shutdown sequences.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA output for integration with external PLC or DCS systems.\u003c\/li\u003e\n\u003cli\u003eStandardized 3300 series rack-mount form factor for seamless system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in industrial environments for the continuous monitoring of casing vibration on rotating equipment. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressors and pumps\u003c\/li\u003e\n\u003cli\u003eLarge electric motors and generators\u003c\/li\u003e\n\u003cli\u003eFans and blowers in critical process loops\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/55-01-04-18-18-00-00-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eVelomitor piezo-velocity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration signals, 4-20 mA proportional, relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack system is powered down before inserting or removing the module to prevent electrical damage or system faults.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack backplane to ensure proper communication and power distribution.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all sensor inputs to minimize electromagnetic interference (EMI) and signal noise.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the 3300 rack chassis according to site-specific instrumentation grounding standards.\u003c\/li\u003e\n\u003cli\u003eVerify that the configuration jumpers and software setpoints match the specific sensor type and machine requirements before placing the system into service.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/55 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/55 is a dual-channel velocity monitor that processes signals from piezo-velocity sensors to provide continuous vibration monitoring and alarm relay actuation for rotating machinery protection.\u003c\/p\u003e\u003ch3\u003eDoes this module include intrinsic safety barriers?\u003c\/h3\u003e\u003cp\u003eNo, this specific order code (ending in -00 for the barrier option) does not include internal intrinsic safety barriers. Ensure your installation environment meets the requirements for non-intrinsically safe equipment or utilize external barriers if required.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43854939553882,"sku":"3300\/55-01-04-18-18-00-00-05-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_39b5fb13-72b5-41fb-b366-cee8df6c7df6.jpg?v=1786906711"},{"product_id":"bently-nevada-3300-55-dual-velocity-monitor","title":"Bently Nevada 3300\/55 Dual Velocity Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a key component of the 3300 Monitoring System, designed to provide continuous, reliable vibration monitoring for industrial rotating machinery. This module accepts input from velocity seismoprobes to monitor casing vibration, ensuring equipment health and protection through precise signal processing and alarm capabilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel monitoring for independent or redundant vibration measurement.\u003c\/li\u003e\n\u003cli\u003eConfigurable scale factors including 500 mV\/in\/s, 145 mV\/in\/s, and 100 mV\/in\/s.\u003c\/li\u003e\n\u003cli\u003eIntegrated 4-20 mA recorder outputs for external data logging and trend analysis.\u003c\/li\u003e\n\u003cli\u003eWide frequency response range from 3 Hz to 10,000 Hz.\u003c\/li\u003e\n\u003cli\u003eRobust design for harsh industrial environments with high humidity tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis monitor is widely used in power generation, oil and gas, and petrochemical facilities to protect critical assets such as turbines, compressors, pumps, and fans. It is specifically engineered for casing vibration monitoring where velocity-based measurements are required to detect mechanical faults.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e3300\/55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e500 mV\/in\/s, 145 mV\/in\/s, or 100 mV\/in\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e3 Hz to 10,000 Hz (180-600,000 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eWithin +\/- 0.33% of full-scale typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eWithin +\/- 1.6% of monitor full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (+32 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is properly grounded to a clean earth point to minimize electrical noise.\u003c\/li\u003e\n\u003cli\u003eAlways power down the rack before inserting or removing the 3300\/55 module to prevent damage to the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all signal inputs to maintain signal integrity and reduce EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the probe sensitivity settings on the module match the installed seismoprobe specifications.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate airflow around the 3300 rack to ensure the module operates within the specified temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the 3300\/55?\u003c\/strong\u003e\u003cbr\u003eThe 3300\/55 is a dual-channel velocity monitor used to measure and track casing vibration on rotating machinery, providing necessary alarm outputs for machinery protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module be used with different seismoprobes?\u003c\/strong\u003e\u003cbr\u003eYes, the module supports multiple sensitivity settings (500, 145, and 100 mV\/in\/s), allowing it to be configured for various compatible velocity sensors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43857948344410,"sku":"3300\/55","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_19d2c0c7-1592-4b8c-9919-de530b1a258d.jpg?v=1786985372"},{"product_id":"bently-nevada-3300-16-13-01-01-00-00-00-xy-gap-dual-vibration-monitor","title":"Bently Nevada 3300\/16-11-01-01-00-00-00 Dual Vibration Monitor","description":"\u003cp\u003eThe Bently Nevada 3300\/16 Dual Vibration Monitor is a rack-mounted module engineered for continuous radial shaft vibration measurement in critical rotating machinery, including turbines, compressors, and pumps. This dual-channel monitor provides essential protection by comparing real-time vibration data against pre-configured Alert and Danger setpoints, facilitating both equipment safety and predictive maintenance.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel radial vibration monitoring for comprehensive shaft analysis.\u003c\/li\u003e\n\u003cli\u003eConfigured for proximity probe inputs via Proximitor sensors.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic with relay actuation for Alert and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for system status: OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eStandardized 3300 rack system compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is designed for use in industrial environments where monitoring shaft displacement is critical to prevent mechanical failure. Common applications include large steam and gas turbines, centrifugal compressors, and high-speed pumps where vibration trends are key indicators of machine health.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-11-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.33% typical, ±1% max at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the rack system to mitigate EMI and ensure signal integrity.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for proximity probe inputs to minimize noise interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot and that the front-panel connectors are securely fastened.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation within the cabinet to ensure the module operates within the specified 0 to 60 deg C temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 11-01-01-00-00-00 suffix indicate?\u003c\/h3\u003e\u003cp\u003eThese codes define the specific configuration of your module, including the XY radial vibration setup, standard agency approval, proximity probe input compatibility, and default relay\/barrier settings.\u003c\/p\u003e\u003ch3\u003eCan this module be used for non-radial vibration measurements?\u003c\/h3\u003e\u003cp\u003eThe 3300\/16 is specifically optimized for radial shaft vibration. For other measurement types, please consult the Bently Nevada 3300 series documentation for the appropriate module model.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43858304401498,"sku":"3300\/16-11-01-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_6b6982c0-2b7e-4099-a776-fbf489fb6bcf.jpg?v=1786990814"},{"product_id":"bently-nevada-3300-12-01-20-01-power-supply-module","title":"Bently Nevada 3300\/12-02-20-00 Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/12 Power Supply Module is a rack-mounted unit designed to provide regulated DC power to all monitoring modules within the 3300 Series system. This module ensures the stable operation of critical machinery protection equipment, including vibration, thrust, eccentricity, expansion, tachometer, and temperature monitors, by delivering clean and reliable power distribution across the rack.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvides regulated DC power to all installed 3300 Series monitoring modules.\u003c\/li\u003e\n\u003cli\u003eIncludes rack-wide OK status monitoring to ensure system health.\u003c\/li\u003e\n\u003cli\u003eSupports high-voltage AC input (220\/240 VAC) for industrial power environments.\u003c\/li\u003e\n\u003cli\u003eStandardized rack-mount profile for seamless integration into existing 3300 Series racks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/12-02-20-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e220\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003eApprox. 150 W total rack capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRegulated DC power and OK relay status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the power supply module.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated rack slot, ensuring proper alignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the integrated front-panel locking mechanism to ensure a reliable electrical connection.\u003c\/li\u003e\n\u003cli\u003eVerify that the input voltage matches the 220\/240 VAC configuration specified by the model suffix.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure operating temperatures remain within the 0 to 60 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 3300\/12-02-20-00 model code indicate?\u003c\/h3\u003e\u003cp\u003eThe 3300\/12 is the base power supply module for the 3300 rack. The '02' suffix indicates agency approval, '20' specifies the 220\/240 VAC input voltage configuration, and '00' denotes the standard input\/output barrier configuration.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with all 3300 series monitors?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/12 is designed to provide regulated DC power to all standard 3300 Series monitoring modules, including those for vibration, thrust, and temperature monitoring.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43858330419290,"sku":"3300\/12-02-20-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_ac7649a5-c512-4a5a-9f59-c167e5fa11f6.jpg?v=1786991011"},{"product_id":"bently-nevada-3300-35-05-02-01-00-00-6-channel-temperature-monitor-1","title":"Bently Nevada 3300\/35-02-02-01-00-00 6-Channel Temperature Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/35-02-02-01-00-00 is a 6-channel Temperature Monitor module engineered for integration into the 3300 Series rack-based monitoring system. This module provides continuous, high-reliability monitoring of critical temperature points in industrial rotating machinery, including turbines, compressors, and large motors. By processing inputs from RTDs or thermocouples and comparing them against user-configurable alarm setpoints, the unit facilitates proactive machinery protection and predictive maintenance.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSix independent monitoring channels for multi-point temperature data acquisition.\u003c\/li\u003e\n\u003cli\u003eCompatibility with standard RTDs (Pt100, Pt1000) and thermocouples (J, K, T types).\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm conditions.\u003c\/li\u003e\n\u003cli\u003eProportional analog outputs (4 to 20 mA and 1 to 5 VDC) for external integration.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators providing real-time status for OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for monitoring thermal conditions in critical assets, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBearing temperature monitoring for large rotating equipment.\u003c\/li\u003e\n\u003cli\u003eStator winding temperature tracking in generators and motors.\u003c\/li\u003e\n\u003cli\u003eCasing temperature monitoring for compressors and turbines.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/35-02-02-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eRTD (Pt100, Pt1000), Thermocouple (J, K, T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA, 1 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Outputs\u003c\/td\u003e\n\u003ctd\u003eAlert and Danger Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack system is powered down before inserting or removing the monitor module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) protection practices to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize EMI\/RFI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the 3300 rack to maintain operating temperatures within the specified -35 degC to +65 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat types of sensors does this module support?\u003c\/h3\u003e\u003cp\u003eThe 3300\/35-02-02-01-00-00 supports a variety of common industrial temperature sensors, specifically RTDs (Pt100 and Pt1000) and J, K, or T type thermocouples.\u003c\/p\u003e\u003ch3\u003eCan this module trigger external alarms?\u003c\/h3\u003e\u003cp\u003eYes, the module is equipped with internal relay outputs that can be configured for Alert and Danger alarm conditions, allowing for direct integration with plant safety or control systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43865301778522,"sku":"3300\/35-02-02-01-00-00","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_b5f4dbe1-bd12-4484-a63c-3e8675daa0b3.jpg?v=1787076400"},{"product_id":"3300-16-11-01-01-00-00-00-bently-nevada-dual-vibration-monitor-1","title":"Bently Nevada 3300\/20-12-01-01-00-00 Dual Thrust Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/20 Dual Thrust Monitor is a rack-mounted module engineered for precise axial thrust position measurement in critical rotating machinery, including turbines and compressors. This specific model, 3300\/20-12-01-01-00-00, is configured for dual-channel thrust monitoring, providing continuous analysis of axial displacement against defined alarm setpoints. By detecting bearing wear or potential mechanical failure early, the module facilitates effective predictive maintenance strategies and minimizes unplanned downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel axial thrust monitoring for comprehensive machine protection.\u003c\/li\u003e\n\u003cli\u003eContinuous parameter comparison against user-defined Alert and Danger alarm setpoints.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for automated alarm actuation.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for quick status verification of OK, Bypass, Alert, and Danger states.\u003c\/li\u003e\n\u003cli\u003eConfigured for use with standard proximity probes and Proximitor sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAxial position monitoring for steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eThrust bearing wear detection in centrifugal compressors.\u003c\/li\u003e\n\u003cli\u003eCritical asset protection in power generation and petrochemical facilities.\u003c\/li\u003e\n\u003cli\u003eIntegration into existing Bently Nevada 3300 monitoring racks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/20-12-01-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe signals via Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical, +\/- 1% max at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be seated firmly in the designated rack slot to ensure proper backplane connectivity.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that proximity probe gaps are calibrated according to the machine manufacturer's specifications.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure the ambient temperature remains within the 0 to 60 degC operating range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to protect internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 12 suffix denote in this model?\u003c\/h3\u003e\u003cp\u003eThe 12 suffix indicates the dual-channel thrust configuration, allowing the monitor to process two independent axial displacement inputs simultaneously.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing 3300 racks?\u003c\/h3\u003e\u003cp\u003eYes, this module is designed for the standard 3300 series rack architecture. Ensure your rack backplane configuration supports the 3300\/20 module type.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43880041087066,"sku":"3300\/20-12-01-01-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_040911b0-b901-4c7f-87a1-67bed57067df.jpg?v=1787248375"},{"product_id":"330930-060-00-00-bently-nevada-3300-xl-standard-extension-cable","title":"Bently Nevada 3300\/35-05-02-01-00-00 6-Channel Temperature Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/35 Temperature Monitor is a rack-mounted module designed to measure multiple temperature points in turbines, compressors, and other critical rotating machinery. The 05 suffix option specifies a 6-channel configuration, supporting both RTD and thermocouple inputs. It continuously compares temperature readings against alarm setpoints, providing early warning of abnormal thermal conditions and enabling predictive maintenance.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSix independent input channels for comprehensive thermal monitoring.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of sensor types including RTDs (Pt100, Pt1000) and thermocouples (J, K, T types).\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic with Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for system status: OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eStandard relay outputs for direct integration with plant safety and control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily used in industrial environments for monitoring bearing temperatures, stator windings, and equipment casings in large rotating machinery such as gas and steam turbines, centrifugal compressors, and large electric motors.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/35-05-02-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eRTD (Pt100, Pt1000), Thermocouple (J, K, T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the rack system to mitigate EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all sensor inputs to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that sensor wiring matches the configured input type (RTD vs. Thermocouple) before applying power.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure operating temperatures remain within the specified -35 degC to +65 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat sensor types are compatible with this module?\u003c\/h3\u003e\u003cp\u003eThis specific model supports RTDs (Pt100 and Pt1000) and standard J, K, and T type thermocouples.\u003c\/p\u003e\u003ch3\u003eDoes this module require external barriers?\u003c\/h3\u003e\u003cp\u003eThe 00 suffix in the barrier option position indicates that this unit is configured with standard input barriers; ensure your installation environment complies with hazardous area requirements if applicable.\u003c\/p\u003e\u003ch3\u003eHow are the alarm setpoints configured?\u003c\/h3\u003e\u003cp\u003eAlarm setpoints for Alert and Danger conditions are configured through the Bently Nevada 3300 system interface, allowing for independent thresholds per channel.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43880801271898,"sku":"3300\/35-05-02-01-00-00","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_48b6f9f2-d61e-4e48-b841-21bb83253c45.jpg?v=1787252286"},{"product_id":"bently-nevada-3300-40-13-01-01-00-00-eccentricity-monitor-module","title":"Bently Nevada 3300\/50-02-02-00-00 Tachometer Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/50 Tachometer Module is a rack-mounted monitoring unit engineered to measure shaft rotational speed and provide critical overspeed protection for rotating machinery such as turbines and compressors. This module processes signals from proximity probes or magnetic pickups, delivering conditioned outputs for integration into plant-wide monitoring and control systems.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel configuration supporting redundant speed inputs.\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring of shaft rotational speed and phase reference.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic for Alert and Danger setpoints with relay actuation.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for system status, including OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eConfigurable signal conditioning for various probe sensitivities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/50-02-02-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003eProximity probes, magnetic pickups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical (+\/- 1% max at 25 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA (+\/- 0.7% accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003ctd\u003e+1 to +5 VDC \/ 0 to -10 VDC (+\/- 1.1% accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be seated firmly in the designated rack slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all input signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the rack and associated transducers to ensure signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the module configuration matches the specific transducer type and speed range required for the application.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/50 module?\u003c\/h3\u003e\u003cp\u003eIt is designed to measure shaft rotational speed and provide reliable overspeed protection for critical rotating equipment by monitoring proximity probe or magnetic pickup inputs.\u003c\/p\u003e\u003ch3\u003eCan this module be used for phase reference?\u003c\/h3\u003e\u003cp\u003eYes, the module is capable of measuring both shaft rotational speed and phase reference signals.\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators on the front panel represent?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide visual status for the OK (system health), Bypass (maintenance mode), Alert (warning threshold), and Danger (shutdown threshold) conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43885018054746,"sku":"3300\/50-02-02-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_b5983246-c743-4b2e-b237-bd9bc29139e3.jpg?v=1787331677"},{"product_id":"bently-nevada-3300-16-02-01-01-00-00-00-dual-vibration-monitor","title":"Bently Nevada 3300\/16-02-01-00-01-00-00 XY\/Gap Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/16 XY\/GAP Dual Vibration Monitor is a rack-mounted module within the 3300 Series monitoring system. This module is engineered to provide continuous, simultaneous measurement of radial shaft vibration (XY) and probe gap voltage (GAP). By monitoring these parameters, the system offers critical protection for rotating machinery such as turbines, compressors, and pumps, facilitating the early detection of mechanical faults including shaft misalignment, rubs, and bearing degradation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel configuration for simultaneous XY vibration and GAP monitoring.\u003c\/li\u003e\n\u003cli\u003eContinuous comparison of input signals against user-defined Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for automated alarm and shutdown sequences.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for quick status verification of OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard proximity probe (Proximitor) sensor inputs.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA outputs for integration with external DCS or PLC systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis monitor is widely utilized in industrial environments for the protection of critical rotating equipment, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressors\u003c\/li\u003e\n\u003cli\u003eLarge industrial pumps and motors\u003c\/li\u003e\n\u003cli\u003eGearboxes and turbo-expanders\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-02-01-00-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Proximity probe channels (XY and GAP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic signals, 4-20 mA, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is properly grounded according to site electrical safety standards to prevent noise interference.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices; avoid touching backplane connectors.\u003c\/li\u003e\n\u003cli\u003eVerify that the rack power is disconnected before inserting or removing the module to prevent electrical arcing or damage to the backplane pins.\u003c\/li\u003e\n\u003cli\u003eEnsure that shielded cables are used for proximity probe signals to minimize EMI\/RFI impact.\u003c\/li\u003e\n\u003cli\u003eConfirm that the module is fully seated in the rack slot and that the front-panel locking mechanisms are engaged.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/16 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/16 is designed to monitor radial shaft vibration and probe gap voltage, providing essential data for machinery health and triggering alarms if pre-set vibration thresholds are exceeded.\u003c\/p\u003e\u003ch3\u003eDoes this module include intrinsic safety barriers?\u003c\/h3\u003e\u003cp\u003eNo, this specific model (3300\/16-02-01-00-01-00-00) is configured with standard input barriers and does not include intrinsic safety barriers.\u003c\/p\u003e\u003ch3\u003eCan this module be used for both Alert and Danger alarms?\u003c\/h3\u003e\u003cp\u003eYes, the module is equipped with relay outputs capable of managing both Alert and Danger alarm conditions based on the configured setpoints.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43885158105178,"sku":"3300\/16-02-01-00-01-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_074acf46-fa44-4e3d-82b5-62c636457b20.jpg?v=1787336027"},{"product_id":"bently-nevada-3300-14-01-22-00-relay-module","title":"Bently Nevada 3300\/48-03-02-02-00 Case Expansion Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/48 Case Expansion Monitor is a rack-mounted module designed to measure the thermal expansion of turbine casings relative to their foundation. This measurement is critical for steam turbines and other large rotating machinery where casing growth can lead to mechanical interference. The monitor continuously compares expansion values against configured alarm setpoints, providing early warning of abnormal conditions to facilitate predictive maintenance.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMeasures casing expansion relative to the foundation.\u003c\/li\u003e\n\u003cli\u003eContinuous parameter comparison against Alert and Danger alarm setpoints.\u003c\/li\u003e\n\u003cli\u003eRelay actuation for alarm conditions.\u003c\/li\u003e\n\u003cli\u003eLED indicators for OK, Bypass, Alert, and Danger status.\u003c\/li\u003e\n\u003cli\u003eCompatible with proximity probes or LVDT signals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily utilized in power generation and industrial facilities for monitoring steam turbine thermal growth, ensuring mechanical alignment and preventing casing damage during thermal cycling.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/48-03-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil or 100 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in the rack slot to maintain proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for transducer inputs to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the transducer signal type matches the module configuration settings.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/48 monitor?\u003c\/h3\u003e\u003cp\u003eThe module monitors the thermal expansion of turbine casings relative to the foundation, which is essential for preventing mechanical interference in large rotating machinery.\u003c\/p\u003e\u003ch3\u003eCan this module be used with different types of sensors?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/48-03-02-02-00 is configured to accept inputs from proximity probes or LVDTs, depending on the specific application requirements.\u003c\/p\u003e\u003ch3\u003eWhat do the alarm setpoints control?\u003c\/h3\u003e\u003cp\u003eThe module provides relay outputs for Alert and Danger conditions, which can be integrated into the plant's safety or control systems to trigger alarms or automated shutdowns.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43892619935834,"sku":"3300\/48-03-02-02-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_717f2436-b995-478a-b230-dced0a3b3167.jpg?v=1787415159"},{"product_id":"bently-nevada-3300-16-15-01-01-00-00-00-dual-vibration-monitor","title":"Bently Nevada 3300\/55-01-01-02-02-00-00-03-00 Dual Velocity Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a rack-mounted module engineered to measure casing vibration velocity using piezo-velocity sensors, such as the Bently Nevada Velomitor. This module provides two independent velocity channels, continuously comparing input signals against user-defined alarm setpoints to provide critical protection for rotating machinery including turbines, compressors, motors, and pumps. By integrating directly into the 3300 rack system, it delivers reliable velocity data essential for both machinery protection and predictive maintenance programs.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel velocity monitoring for independent measurement paths.\u003c\/li\u003e\n\u003cli\u003eCompatible with Velomitor piezo-velocity sensors.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm setpoint comparison for Alert and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eDual relay outputs for automated machinery shutdown or alarm annunciation.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for system status, including OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eConfigurable scaling and output options (4-20 mA, 1-5 VDC, 0 to -10 VDC).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is designed for use in industrial environments where casing vibration monitoring is required to detect mechanical degradation. Typical applications include monitoring of centrifugal pumps, gas and steam turbines, large industrial motors, and reciprocating compressors.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/55-01-01-02-02-00-00-03-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conditioning Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.33% typical, ±1% max at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for transducer inputs to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the 3300 rack system according to site electrical safety standards.\u003c\/li\u003e\n\u003cli\u003eHandle with care using ESD-safe procedures to protect sensitive internal circuitry.\u003c\/li\u003e\n\u003cli\u003eConfirm that the configuration jumpers and software settings match the specific transducer type and required alarm logic before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the purpose of the 3300\/55 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/55 is a dual-channel monitor used to measure casing vibration velocity. It processes signals from Velomitor sensors and provides alarm outputs to protect critical rotating equipment.\u003c\/p\u003e\u003ch3\u003eHow are the alarm setpoints managed?\u003c\/h3\u003e\u003cp\u003eThe module continuously compares the input velocity signals against pre-configured setpoints. When these thresholds are exceeded, the module triggers the internal relays to provide Alert or Danger status signals.\u003c\/p\u003e\u003ch3\u003eCan this module be used with other sensors?\u003c\/h3\u003e\u003cp\u003eThis specific model (3300\/55-01-01-02-02-00-00-03-00) is configured for Velomitor piezo-velocity sensors. Consult the Bently Nevada 3300 system manual for compatibility with other sensor types.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43892703559770,"sku":"3300\/55-01-01-02-02-00-00-03-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_4fb8ed83-2d72-42a8-86c1-90ee6cf5e46a.jpg?v=1787418240"},{"product_id":"bently-nevada-3300-16-13-01-00-00-00-00-dual-vibration-xy-gap-monitor","title":"Bently Nevada 3300\/16-15-01-01-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 3300\/16 Dual Vibration Monitor is a rack-mounted module designed to measure radial shaft vibration in critical rotating machinery, such as turbines and compressors. The 15 suffix option specifies a dual-channel XY vibration configuration, enabling simultaneous monitoring of two orthogonal vibration signals. This monitor continuously compares vibration parameters against user-defined alarm setpoints, providing early warning of mechanical issues and supporting predictive maintenance strategies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-channel XY vibration monitoring for comprehensive shaft analysis.\u003c\/li\u003e\n\u003cli\u003eContinuous signal conditioning and comparison against Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eStandard relay outputs for alarm annunciation.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Bently Nevada proximity probe and Proximitor sensor systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis module is primarily used in industrial protection systems for monitoring radial vibration on rotating shafts in power generation, oil and gas, and petrochemical facilities. It is designed for integration into the Bently Nevada 3300 Monitoring System rack.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-15-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical, +\/- 1% max at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot and that the front panel screws are tightened to ensure proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper ventilation within the cabinet to maintain the operating temperature between 0 and 60 degC.\u003c\/li\u003e\n\u003cli\u003eHandle with ESD-safe precautions to protect sensitive internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 15 suffix represent in this model code?\u003c\/strong\u003e\u003cbr\u003eThe 15 suffix indicates the measurement configuration is set for XY dual vibration, allowing the monitor to process two orthogonal vibration signals simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with standard proximity probes?\u003c\/strong\u003e\u003cbr\u003eYes, this model is configured for use with standard Bently Nevada proximity probes and their associated Proximitor sensors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43900001976410,"sku":"3300\/16-15-01-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_16a4b03f-c201-4aa9-9fa8-30cb48619308.jpg?v=1787590624"},{"product_id":"bently-nevada-3300-20-01-01-02-01-00-dual-thrust-monitor-2","title":"Bently Nevada 3300\/14-01-22-00 Relay Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/14-01-22-00 is a rack-mounted Relay Module designed for the Bently Nevada 3300 Monitoring System. This module serves as a critical interface between the system's internal monitoring functions—such as vibration, thrust, eccentricity, and expansion—and external machinery protection or control systems. It provides reliable relay outputs triggered by Alert and Danger conditions, facilitating automated shutdown or alarm annunciation logic.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvides dedicated relay outputs for Alert and Danger alarm states.\u003c\/li\u003e\n\u003cli\u003eForm-C (SPDT) contact configuration for versatile integration.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for real-time relay status monitoring.\u003c\/li\u003e\n\u003cli\u003eStandard 3300 rack-mount form factor for seamless system integration.\u003c\/li\u003e\n\u003cli\u003eSupports robust machinery protection and emergency shutdown sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically deployed in industrial environments requiring automated protection for rotating machinery. It is commonly used in power generation, oil and gas, and petrochemical facilities to interface 3300 monitoring racks with PLC or DCS shutdown logic.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/14-01-22-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRelay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eDual Form-C (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A at 24 VDC or 120 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage or unintended relay activation.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot to ensure proper backplane communication.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for relay output connections to minimize EMI\/RFI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure that the contact load ratings (5 A at 24 VDC\/120 VAC) are strictly observed to prevent relay contact welding or failure.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the 3300 rack to ensure operation within the specified 0 to 60 degC temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 3300\/14-01-22-00 model code indicate?\u003c\/h3\u003e\u003cp\u003eThe code represents the base 3300\/14 relay module with standard agency approval (01), a specific relay configuration (22), and standard barrier options (00).\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other Bently Nevada systems?\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for the Bently Nevada 3300 series rack system and is not directly compatible with 3500 or other series racks.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43900677718106,"sku":"3300\/14-01-22-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_8dac9fdc-7f3b-4839-a608-100d799df7f2.jpg?v=1787598207"},{"product_id":"bently-nevada-3300-55-01-04-12-12-00-00-05-01-dual-velocity-monitor","title":"Bently Nevada 3300\/55-01-05-12-12-00-00-05-00 Dual Velocity Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a rack-mounted module within the 3300 Series monitoring system. It is specifically engineered to measure casing vibration velocity by interfacing with Velomitor piezo-velocity sensors. The 3300\/55-01-05-12-12-00-00-05-00 configuration provides two independent channels of vibration monitoring, featuring enhanced input scaling and relay logic designed for the protection of critical turbomachinery.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel independent velocity measurement.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Velomitor piezo-velocity sensors.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA outputs for integration with external control systems (DCS\/PLC).\u003c\/li\u003e\n\u003cli\u003eConfigurable relay outputs for Alert and Danger alarm conditions.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED status indicators for OK, Bypass, Alert, and Danger states.\u003c\/li\u003e\n\u003cli\u003eEnhanced input scaling and alarm logic for precise machinery protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely used in industrial environments for continuous monitoring of critical rotating equipment, including steam turbines, gas turbines, centrifugal compressors, and large pumps. It provides the necessary signal processing to detect casing vibration anomalies and trigger protective shutdowns or operator alerts.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/55-01-05-12-12-00-00-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Velomitor piezo-velocity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA proportional, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is properly seated in the rack slot and that the front-panel screws are tightened to ensure a secure ground connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for sensor inputs to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the cabinet to ensure the ambient temperature remains within the 0 degC to +60 degC range.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) handling procedures when touching internal components or connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/55 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/55 is designed to monitor casing vibration velocity. It processes signals from two Velomitor sensors and compares them against user-defined Alert and Danger setpoints to protect rotating machinery.\u003c\/p\u003e\u003ch3\u003eCan this module be used in hazardous areas?\u003c\/h3\u003e\u003cp\u003eThis specific order code (3300\/55-01-05-12-12-00-00-05-00) includes standard input barrier configuration (no intrinsic safety). Please verify your site's hazardous area requirements before installation.\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators on the front panel represent?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide immediate visual feedback for the module's health and the status of the monitored machinery, specifically indicating OK (sensor\/module health), Bypass (maintenance mode), Alert, and Danger alarm conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43900681945178,"sku":"3300\/55-01-05-12-12-00-00-05-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_b5732d4c-64fd-4a43-9544-e9fc2ffa5f80.jpg?v=1787598378"},{"product_id":"bently-nevada-3300-25-04-04-04-01-02-01-01-dual-accelerometer-monitor","title":"Bently Nevada 3300\/25-03-06-06-01-00-02-00 Dual Accelerometer Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/25 Dual Accelerometer Monitor is a rack-mounted module within the 3300 Series monitoring system. It is engineered to provide continuous, high-reliability measurement of casing vibration acceleration using two independent accelerometer inputs. This specific configuration (3300\/25-03-06-06-01-00-02-00) is optimized for critical turbomachinery applications, including compressors and pumps, where high-frequency vibration detection is essential for predictive maintenance and machinery protection.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual independent accelerometer input channels for comprehensive casing vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA outputs for integration with external control systems or data acquisition units.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm conditions, facilitating automated machine shutdown or operator notification.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators providing real-time status for OK, Bypass, Alert, and Danger states.\u003c\/li\u003e\n\u003cli\u003eExtended full-scale range configuration for high-frequency vibration sensitivity.\u003c\/li\u003e\n\u003cli\u003eStandard input barrier configuration for signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 3300\/25 monitor is specifically designed for use in industrial environments requiring precise casing vibration analysis. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCentrifugal and reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eIndustrial pumps and fans.\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eGearboxes and high-speed rotating equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/25-03-06-06-01-00-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Accelerometer channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic signals, 4-20 mA, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 series rack is properly grounded to a clean instrument earth to prevent ground loops and EMI interference.\u003c\/li\u003e\n\u003cli\u003eThe module should be inserted into the rack only after ensuring the power supply is stable and within specified limits.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all transducer inputs to maintain signal integrity in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure operating temperatures remain within the specified -30 degC to +65 degC range.\u003c\/li\u003e\n\u003cli\u003eAlways perform system configuration and setpoint adjustments according to the specific machinery requirements and Bently Nevada technical documentation.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent ESD damage to internal components; use appropriate grounding straps during installation or maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/25 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/25 is a dual-channel monitor designed to process signals from accelerometers to measure casing vibration, providing alarm and shutdown capabilities for rotating machinery.\u003c\/p\u003e\u003ch3\u003eCan this module be used for high-frequency monitoring?\u003c\/h3\u003e\u003cp\u003eYes, this specific order code includes an extended full-scale range option, making it suitable for applications where high-frequency vibration detection is necessary.\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators on the front panel signify?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide immediate visual feedback on the health of the transducer (OK), the alarm status (Alert\/Danger), and whether the channel is currently in a maintenance or test mode (Bypass).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43908910514266,"sku":"3300\/25-03-06-06-01-00-02-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_4b247818-e292-406c-bb57-cc07493755c0.jpg?v=1787673884"},{"product_id":"bently-nevada-3300-16-13-01-01-00-00-00-xy-gap-dual-vibration-monitor-3","title":"Bently Nevada 3300\/16-02-01-01-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/16 Dual Vibration Monitor is a rack-mounted module engineered for the continuous monitoring of radial shaft vibration in critical rotating machinery, such as turbines, compressors, and pumps. This specific model, 3300\/16-02-01-01-00-00-00, provides dual-channel vibration monitoring, allowing for the simultaneous tracking of two independent vibration signals. By continuously comparing input parameters against user-defined alarm setpoints, the monitor provides essential early warning of mechanical degradation, supporting effective predictive maintenance programs.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel vibration monitoring for comprehensive machine protection.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard proximity probe and Proximitor sensor inputs.\u003c\/li\u003e\n\u003cli\u003eIntegrated Alert and Danger alarm setpoints with relay output actuation.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for quick status verification of OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eStandardized 3300 series rack-mount form factor for seamless integration into existing monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial compressor protection.\u003c\/li\u003e\n\u003cli\u003eLarge motor and generator bearing vibration analysis.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose rotating equipment requiring radial vibration monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-02-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 W per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe signals via Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical, +\/- 1% max at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack backplane to ensure reliable connection of power and signal buses.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize electromagnetic interference (EMI) and signal noise.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the equipment cabinet to ensure the module operates within the 0 to 60 degC temperature range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD (Electrostatic Discharge) precautions to protect sensitive internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 02 measurement option signify?\u003c\/h3\u003e\u003cp\u003eThe 02 option indicates that the module is configured for dual-channel vibration monitoring, allowing it to process two independent input signals simultaneously.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing 3300 racks?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/16 is designed to be fully compatible with the standard Bently Nevada 3300 series rack architecture.\u003c\/p\u003e\u003ch3\u003eWhat is the primary function of the relay outputs?\u003c\/h3\u003e\u003cp\u003eThe relay outputs are used to trigger external alarms or trip logic systems when the monitored vibration levels exceed the pre-configured Alert or Danger setpoints.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43932981067866,"sku":"3300\/16-02-01-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_e68f5366-f472-4ebb-b4d8-dd815095695a.jpg?v=1787934353"},{"product_id":"bently-nevada-3300-16-01-01-02-01-00-02-xy-gap-dual-vibration-monitor","title":"Bently Nevada 3300\/16-01-01-02-01-00-02 XY\/Gap Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/16 XY\/Gap Dual Vibration Monitor is a critical component of the 3300 Monitoring System, designed to provide continuous, reliable protection for rotating machinery. This module monitors radial vibration (XY) and gap (position) measurements, providing essential data for assessing the mechanical health of turbines, compressors, and pumps. It processes signals from Proximitor sensors to detect excessive vibration levels and shaft displacement, triggering alarms or trip functions when thresholds are exceeded.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel configuration for XY vibration and gap monitoring.\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 8 mm, 3300 XL 8 mm, and 7200 5 mm\/8 mm Proximitor sensors.\u003c\/li\u003e\n\u003cli\u003eConfigured for 200 mV\/mil transducer sensitivity.\u003c\/li\u003e\n\u003cli\u003eIntegrated trip multiply function (3X) for startup and transient analysis.\u003c\/li\u003e\n\u003cli\u003eEquipped with hermetically-sealed alarm relays for high reliability in industrial environments.\u003c\/li\u003e\n\u003cli\u003eCSA\/NRTL\/C agency approval for hazardous location compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis monitor is widely utilized in power generation, petrochemical, and oil and gas industries. It is specifically engineered for monitoring sleeve-bearing machines where radial vibration and shaft position are critical indicators of machine integrity.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e3300\/16-01-01-02-01-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0-3 mils peak-to-peak (pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input\u003c\/td\u003e\n\u003ctd\u003e3300 8 mm \/ 3300 XL 8 mm \/ 7200 5 mm \u0026amp; 8 mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Type\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003e3X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack power is disconnected before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot and that the front panel screws are tightened to ensure proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all transducer inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eEnsure proper routing of signal cables away from high-voltage power lines or high-frequency switching equipment.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to protect internal circuitry from electrostatic discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/16 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/16 is designed to monitor radial vibration and gap (shaft position) on rotating machinery, providing alarm and trip capabilities to prevent equipment damage.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing 7200 series sensors?\u003c\/h3\u003e\u003cp\u003eYes, this specific model is configured to support 7200 series 5 mm and 8 mm Proximitor sensors, as well as the 3300 series 8 mm sensors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43933129474138,"sku":"3300\/16-01-01-02-01-00-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_0bdc10a9-ea82-46d5-bc41-2ff94bb1a601.jpg?v=1787938065"},{"product_id":"bently-nevada-3300-55-01-04-02-02-03-00-05-00-dual-velocity-monitor","title":"Bently Nevada 3300\/70-XX-00 Dual Valve Position Indicator","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/70 Dual Valve Position Indicator is a specialized rack-mounted module within the 3300 Series monitoring system. It is engineered to provide precise, continuous monitoring of valve positions in large rotating machinery, such as steam and gas turbines. The module features two independent measurement channels, allowing for redundant or dual-point tracking of valve movement to support machinery protection through integrated alarm and trip logic.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual independent channels for valve position measurement.\u003c\/li\u003e\n\u003cli\u003eProportional analog outputs (4 to 20 mA and 1 to 5 VDC) for external integration.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm conditions.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED status indicators for OK, Bypass, Alert, and Danger states.\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration into standard Bently Nevada 3300 series rack systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSteam turbine valve position monitoring.\u003c\/li\u003e\n\u003cli\u003eGas turbine valve tracking.\u003c\/li\u003e\n\u003cli\u003eCritical machinery protection systems requiring valve position feedback.\u003c\/li\u003e\n\u003cli\u003eLarge rotating equipment where valve travel accuracy is essential for operational safety.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/70-XX-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Proximity probe channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA, 1 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Outputs\u003c\/td\u003e\n\u003ctd\u003eRelay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize electromagnetic interference (EMI) in industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the cabinet to ensure the module operates within its specified temperature range (0 to 60 degC).\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) handling procedures when touching the module circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the XX in the model number represent?\u003c\/h3\u003e\u003cp\u003eThe XX suffix denotes the specific measurement range and transducer compatibility configuration required for your specific valve application. Please verify your system requirements before ordering.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other Bently Nevada series?\u003c\/h3\u003e\u003cp\u003eNo, this module is specifically designed for the 3300 Series rack system and is not directly compatible with 3500 or other series hardware.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43933421076570,"sku":"3300\/70-XX-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_4d2591f3-f885-49b9-bf3a-811b9a664242.jpg?v=1787941536"},{"product_id":"bently-nevada-3300-50-02-02-00-00-tachometer-module","title":"Bently Nevada 3300\/01 System Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/01 System Monitor is the primary supervisory module for the 3300 rack system. It is designed to oversee the health and operational status of all installed monitoring modules within the rack. By coordinating alarm relays and managing communication across the rack backplane, the 3300\/01 ensures centralized diagnostics and reliable alarm management for critical rotating machinery protection systems, including turbines and compressors.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvides centralized supervision of all monitoring modules installed in the 3300 rack.\u003c\/li\u003e\n\u003cli\u003eCoordinates OK, Bypass, Alert, and Danger relay logic.\u003c\/li\u003e\n\u003cli\u003eMonitors rack power supply status and backplane communication integrity.\u003c\/li\u003e\n\u003cli\u003eFeatures front-panel LED indicators for immediate rack and module status diagnostics.\u003c\/li\u003e\n\u003cli\u003eInterfaces with external control and automation systems for consolidated alarm signaling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is essential for the operation of Bently Nevada 3300 series machinery protection systems. It is typically deployed in industrial environments to monitor critical rotating equipment such as steam turbines, gas turbines, centrifugal compressors, and large pumps where rack-level alarm coordination is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/01 (330001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSystem Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack system is powered down before inserting or removing the System Monitor module to prevent electrical damage or unintended relay activation.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for standard 3300 rack slots; ensure proper seating to maintain backplane connectivity.\u003c\/li\u003e\n\u003cli\u003eHandle with care using standard ESD (Electrostatic Discharge) protection practices to avoid damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that the rack power supply is stable and within specified limits before commissioning the system.\u003c\/li\u003e\n\u003cli\u003eEnsure all external wiring for alarm relays and communication interfaces is properly shielded and routed away from high-EMI sources to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/01 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/01 acts as the system monitor, providing rack-level supervision, coordinating alarm relays, and managing communication across the rack backplane for all other installed modules.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other Bently Nevada series?\u003c\/h3\u003e\u003cp\u003eNo, the 3300\/01 is specifically designed for the Bently Nevada 3300 series rack system and is not interchangeable with 3500 or other series hardware.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43933576134746,"sku":"3300\/01","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_409ea430-9a73-4bd1-930d-8f56f4fd35c3.jpg?v=1787944908"},{"product_id":"bently-nevada-3300-55-01-01-02-02-00-00-03-00-dual-velocity-monitor-3","title":"Bently Nevada 3300\/16-03-01-01-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/16 Dual Vibration Monitor is a rack-mounted module within the 3300 Series system, engineered to provide continuous monitoring of radial shaft vibration across two independent channels. This specific configuration, 3300\/16-03-01-01-00-00-00, is designed for critical machinery protection in industrial environments such as turbines, compressors, and pumps. It continuously processes vibration signals from proximity probes, comparing them against user-defined alarm setpoints to detect mechanical faults like imbalance, misalignment, or bearing wear.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel monitoring for radial shaft vibration.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Proximitor sensors.\u003c\/li\u003e\n\u003cli\u003eProvides proportional 4-20 mA outputs for integration with external control systems.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm conditions.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for status monitoring (OK, Bypass, Alert, and Danger).\u003c\/li\u003e\n\u003cli\u003eContinuous signal processing for real-time machinery protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis monitor is primarily utilized in the protection of rotating machinery, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressors\u003c\/li\u003e\n\u003cli\u003eLarge industrial pumps\u003c\/li\u003e\n\u003cli\u003eMotors and gearboxes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-03-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eTwo independent proximity probe channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration, 4-20 mA, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is properly grounded according to site electrical standards.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent electrostatic discharge (ESD) damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot before applying power.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for transducer inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure operating temperatures remain within the specified -30 degC to +65 degC range.\u003c\/li\u003e\n\u003cli\u003eAlways power down the rack before inserting or removing the monitor module.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 3300\/16-03-01-01-00-00-00 model code indicate?\u003c\/h3\u003e\u003cp\u003eThe code specifies a dual vibration monitor with standard industrial approvals, configured for proximity probe inputs, standard relay outputs, and a standard measurement range with no custom modifications.\u003c\/p\u003e\u003ch3\u003eCan this module be used for XY vibration monitoring?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/16 is designed to monitor two independent channels, making it suitable for XY vibration measurement configurations on rotating shafts.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43941620744282,"sku":"3300\/16-03-01-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_2d1d2382-7cce-4a0f-82f7-f0f2a93aa9d7.jpg?v=1788023598"},{"product_id":"bently-nevada-3300-48-03-02-02-00-case-expansion-monitor","title":"Bently Nevada 3300\/48-03-02-00-00 Case Expansion Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/48 Case Expansion Monitor is a specialized rack-mounted module engineered to track the thermal expansion of turbine casings relative to the machine foundation. This monitoring is essential for large rotating equipment, such as steam turbines, where monitoring casing growth is vital to prevent mechanical interference and ensure operational safety. The module provides continuous signal processing and compares real-time expansion data against user-defined alarm setpoints to facilitate predictive maintenance.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvides continuous measurement of casing expansion relative to the foundation.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm setpoint comparison for Alert and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eSupports input from proximity probes or LVDTs for flexible sensing configurations.\u003c\/li\u003e\n\u003cli\u003eFeatures front-panel LED indicators for system status, including OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eStandard relay outputs for external alarm integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/48-03-02-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil or 100 mV\/mil (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical; +\/- 1% max at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be installed in a clean, dry environment within the specified temperature range.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack backplane to ensure proper power and signal connectivity.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions when handling the module circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/48 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/48 is designed to monitor the thermal expansion of turbine casings relative to their foundation, helping to prevent mechanical interference during machine operation.\u003c\/p\u003e\u003ch3\u003eWhat types of sensors does this monitor support?\u003c\/h3\u003e\u003cp\u003eThis model is configured to accept inputs from proximity probes or LVDTs (Linear Variable Differential Transformers) via Proximitor sensors.\u003c\/p\u003e\u003ch3\u003eHow are alarm conditions indicated?\u003c\/h3\u003e\u003cp\u003eThe module features front-panel LED indicators for OK, Bypass, Alert, and Danger statuses, and provides relay outputs for external alarm notification.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43942529269850,"sku":"3300\/48-03-02-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_78ef1ca4-10ec-430e-a507-f0ce0bd9efb7.jpg?v=1788028487"}],"url":"https:\/\/www.spareoil.com\/collections\/bently-nevada-3300-series.oembed?page=2","provider":"SpareOil Automation","version":"1.0","type":"link"}