{"title":"GE VersaMax","description":"\u003cp\u003eThe GE VersaMax collection offers a versatile and compact solution for distributed control and I\/O needs. Here you will find original VersaMax CPUs, I\/O modules (IC200 series), and power supplies designed for seamless integration. Whether you are maintaining existing automation cells or expanding your control logic, our genuine VersaMax inventory provides the modularity and reliability required for modern industrial applications.\u003c\/p\u003e","products":[{"product_id":"ic200chs001-ge-fanuc-versamax-barrier-terminal-base","title":"IC200CHS001 | GE Fanuc | VersaMax Barrier Terminal Base","description":"\u003ch3 class=\"\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200CHS001 (Model: IC200CHS001)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity barrier-style I\/O carrier within the GE VersaMax series,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edesigned to provide the physical and electrical foundation for single I\/O modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeaturing 36 barrier-style screw terminals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit facilitates secure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ehigh-density field wiring while establishing a seamless backplane connection for the PLC CPU or Network Interface Unit (NIU).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200CHS001 (Part Number: IC200CHS001)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis the preferred choice for applications requiring rigid wire retention and maximum electrical separation between adjacent points.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eAs a fundamental component of the modular VersaMax architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200CHS001\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupports \"hot-swapping\" of I\/O modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing maintenance without disrupting the field wiring or the rest of the PLC rack.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts barrier-type design is specifically engineered to prevent accidental short circuits,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it exceptionally reliable in high-vibration industrial environments or systems utilizing high-current AC\/DC discrete I\/O and sensitive analog signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200CHS001\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecarrier is built to utility-grade standards to ensure continuous data and power distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200CHS001\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSeries\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVersaMax I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTerminal Type\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBarrier-Style Screw Terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNumber of Points\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e36 points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWire Gauge Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAWG 22 to AWG 14 (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e36 to 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 mm²); Solid or Stranded copper\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCurrent Capacity\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eMax 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Amps per terminal point\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eMax 8.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Amps total per Power\/Ground bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVoltage Rating\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e264 VAC (Continuous); 300 VAC (Transient)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTerminal Torque\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 to 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e68 Nm (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e37 to 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 lb-ft)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Capacity\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1 VersaMax I\/O Module per carrier\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Options\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e35mm DIN rail or direct Panel Mount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBackplane Connectivity\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated slide-locking bus connector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +70°C (Storage); 0°C to +60°C (Operating)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e40 kg (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e88 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e110mm x 66.\u003c\/span\u003e\u003cspan class=\"\"\u003e8mm x 50mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870822535258,"sku":"IC200CHS001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/210_485fd845-5a03-41ed-aa9d-8c52e79eed17.jpg?v=1772245431"},{"product_id":"versamax-4-point-0-10vdc-card-ge-fanuc-ic200alg322d","title":"VersaMax 4-Point 0-10VDC Card | GE Fanuc IC200ALG322D","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322D (Model: IC200ALG322D)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision analog output module from the GE VersaMax I\/O family, engineered to provide four channels of high-resolution voltage control. This module is essential for converting digital CPU data into proportional 0–10 V DC signals, facilitating the accurate command of proportional valves, variable frequency drives (VFDs), and precision actuators. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322D (Part Number: IC200ALG322D)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed with a focus on signal purity and hardware protection, making it a cornerstone for distributed control architectures.\u003c\/p\u003e\n\u003cp\u003eTo ensure reliability in harsh industrial environments, the module features robust galvanic isolation rated for 250 VAC continuous operation. This isolation barrier prevents ground loops and safeguards the internal logic backplane from field-side electrical transients. With 12-bit resolution providing 4,096 distinct output steps, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures smooth control curves and minimal jitter across all four isolated channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the following electrical and operational performance characteristics:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Fanuc \/ Emerson\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322D\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e: VersaMax I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e: Isolated Analog Voltage (Single-ended)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 12 bits (Unsigned)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e: 0 to +10 V DC (Default); 10.24 V DC Full Scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Load Impedance\u003c\/strong\u003e: Minimum 5,000 Ohms (Resistive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: 250 VAC continuous (Field-to-backplane); 1500 VAC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e: 160 mA maximum at 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e: 18 to 30 V DC (24 V DC nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Power Current Draw\u003c\/strong\u003e: 210 mA maximum at 12V DC (internal conversion)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Crosstalk\u003c\/strong\u003e: ≥ 70 dB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.1% of full scale typical at 25°C; ±0.5% over full temp range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSettling Time\u003c\/strong\u003e: \u0026lt; 5 ms to 95% of full scale change\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: LED indicators for Power status and Module OK (Health)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870822633562,"sku":"IC200ALG322D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/209._84473821-ecc9-4d75-ab9d-dd79f8bef558.jpg?v=1772245219"},{"product_id":"emerson-ic200alg321-12-bit-analog-module-datasheet-technical-manual","title":"Emerson IC200ALG321 12-Bit Analog Module Datasheet Technical Manual","description":"\u003ch2\u003eEmerson IC200ALG321 VersaMax Analog Output Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson IC200ALG321\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ALG321\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for translating digital CPU commands into physical modulation within Emerson VersaMax PLC platforms. This 4-channel module converts digital data registers into single-ended analog voltage signals to drive control valves, actuators, and speed regulators.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (formerly GE Fanuc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA maximum at 5 VDC (Backplane current draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 Points (Single-ended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0 to +10 VDC Nominal, 0 to +10.24 VDC Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-Bit binary (left-justified within 16-bit data format)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e0.3 ms maximum for all 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.3% of full scale at 25 deg C; +-1.0% over full temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC (24 VDC Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Current\u003c\/td\u003e\n\u003ctd\u003e210 mA maximum based on external load parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC continuous \/ 707 VDC for 1 minute (Field-to-Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators: OK (Backplane) and FLD PWR (Field Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Logic\u003c\/td\u003e\n\u003ctd\u003eHold Last State or Default to 0 VDC upon CPU communication failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe analog output unit executes high-speed conversion with an update rate of 0.3 ms across all 4 points, aligning with Profinet \/ EtherNet\/IP deterministic networks via the interface carriers. The module layout supports flexible system expansion, ensuring optimal backplane bus communication velocity across adjacent terminal assemblies. The 12-bit analog architecture features direct left-justified configuration compatibility with system registers, providing smooth loop scaling and software scaling options without requiring localized script patches.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the IC200ALG321 behave if communication with the PLC processor is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module behavior is user-configurable during initial system setup. It can be programmed to either hold the last valid analog voltage value on the channel or immediately drop the output signal to a default 0 VDC state to enforce a predictable loop safety shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the 500 VAC optical isolation barrier on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 500 VAC continuous galvanic isolation decouples the sensitive internal backplane logic from the 24 VDC field side power loops. This prevents high-voltage transient spikes, field shorts, or ground loops from compromising the logic state of the primary PLC CPU rack.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Engagement and Carrier Insertion\u003c\/strong\u003e: Press the module firmly onto its matching VersaMax I\/O carrier base. Ensure the integrated latch mechanisms engage cleanly and verify that the connector pins align correctly before locking the module down to ensure low-resistance communication contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Regulations\u003c\/strong\u003e: Terminate the external signal cable shields at a single-point earth ground terminal block located near the base of the control panel. Do not loop-ground the shield at both the actuator and the PLC terminal block to avoid circulating currents that induce electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Termination\u003c\/strong\u003e: Connect a stable, external 24 VDC power supply to the designated terminals on the I\/O carrier to drive the output circuit shunts. Confirm the field power status via the FLD PWR LED on the front panel before commissioning loop cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Profile Separation\u003c\/strong\u003e: Ensure adequate vertical clearance layout within the panel enclosure to enable unhindered ambient air passage across the chassis faceplate, keeping localized temperatures strictly below the +60 deg C operating threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870855303258,"sku":"IC200ALG321","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/225.jpg?v=1772430379"},{"product_id":"ge-fanuc-ic200alg240-8-channel-16-bit-high-precision-i-o","title":"GE Fanuc IC200ALG240 | 8-Channel 16-Bit High-Precision I\/O","description":"\u003cp\u003eGE Fanuc IC200ALG240 VersaMax 8-Channel 16-Bit Isolated Analog Input Module\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG240 (Model: IC200ALG240)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, intelligent analog input module from the GE Fanuc (now Emerson) VersaMax series. Engineered for precision and signal integrity, this module features eight independent channels with full channel-to-channel isolation. This advanced electrical architecture is specifically designed to eliminate ground loops and mitigate common-mode voltage interference, making the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG240 (Part Number: IC200ALG240)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe optimal solution for complex process control environments where sensors are distributed over vast distances or located in high-EMI zones.\u003c\/p\u003e\n\u003cp\u003eWith a 16-bit Analog-to-Digital converter, the module provides a resolution of 381 nA in current mode and 381 µV in voltage mode. It supports a versatile range of industrial signals, including ±10 VDC, 0-10 VDC, 4-20 mA, and 0-20 mA. This high-resolution acquisition ensures that critical process variables are represented with maximum fidelity in the PLC logic, meeting the strict requirements of power generation, chemical processing, and precision machine automation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains signal purity through a sophisticated combination of galvanic isolation and configurable digital filtering.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Fanuc \/ Emerson\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG240\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e: VersaMax PLC \/ I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Intelligent Analog Input (Full Isolation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 8 Channels (Channel-to-channel isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 16-Bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Ranges\u003c\/strong\u003e: ±10 VDC, 0 to 10 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current Ranges\u003c\/strong\u003e: 4-20 mA, 0-20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e: 16.7 ms (at 60 Hz filter) \/ 20 ms (at 50 Hz filter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: Voltage: \u0026gt;1 MΩ; Current: 250 Ω (Precision Shunt)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Accuracy\u003c\/strong\u003e: ±0.1% of full scale at 25°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e: Channel-to-channel and Channel-to-Backplane (Galvanic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e: 19.5 - 30 VDC (100 mA maximum + load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e: 15 mA maximum at 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: LED Indicators for OK (Module Status) and FLD PWR (Field Power)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiltering\u003c\/strong\u003e: Software-configurable 50Hz\/60Hz notch filters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 11.0 cm x 6.68 cm x 5.0 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870855532634,"sku":"IC200ALG240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/195.jpg?v=1772241090"},{"product_id":"ic200alg230-ge-fanuc-versamax-analog-input-12-bit-new","title":"IC200ALG230 GE Fanuc | VersaMax Analog Input 12-Bit New","description":"\u003cp\u003eGE Fanuc IC200ALG230 VersaMax 4-Channel 12-Bit Analog Input Module\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG230 (Model: IC200ALG230)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 12-bit analog input module from the GE Fanuc (Emerson) VersaMax series. Engineered for precision signal acquisition, this module provides four independent channels capable of interfacing with a wide range of field transmitters and sensors.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG230 (Part Number: IC200ALG230)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile solution for industrial automation, supporting unipolar voltage (0 to +10V), bipolar voltage (-10V to +10V), and current signals (4 to 20 mA). It converts these analog process variables—such as flow rates, pressure levels, and temperatures—into high-resolution digital data for use by the VersaMax CPU or Network Interface Unit (NIU). With its compact footprint and carrier-based mounting system, it is ideal for space-constrained control cabinets and distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule provides rapid signal conversion and integrated hardware diagnostics for reliable process control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Fanuc \/ Emerson\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG230\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: VersaMax PLC \/ I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 4 Single-Ended channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 12 bits (1 part in 4096)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Ranges\u003c\/strong\u003e: 0 to +10V DC, -10V to +10V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Ranges\u003c\/strong\u003e: 4 to 20 mA (Hardware jumper required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: \u0026gt; 1MΩ (Voltage), 250Ω (Current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e: 5.0 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e: 0.4 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Accuracy\u003c\/strong\u003e: ±0.25% of full scale at 25°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e: 125 mA at 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e: +24V DC nominal (Required for current loop excitation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e: 2 Hardware jumpers and software range selection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Internal power loss detection and range error reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: 250 VAC continuous; 1500 VAC for 1 minute (Group to Backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 110 mm x 66.8 mm x 50 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.14 kg (0.31 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870855762010,"sku":"IC200ALG230","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/194..jpg?v=1772240880"},{"product_id":"ge-fanuc-ic200acc201-plc-expansion-signal-terminator","title":"GE Fanuc IC200ACC201 PLC Expansion Signal Terminator","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC200ACC201 functions as a critical passive component for the VersaMax PLC I\/O expansion architecture. This terminator plug must reside at the final physical node of any expansion daisy chain to ensure reliable high-speed data communication. By providing precise impedance matching, the IC200ACC201 eliminates signal reflections that lead to bus corruption, intermittent communication loss, and CPU watchdog timeouts. It acts as the definitive \"end-of-line\" marker for the expansion transmitter (ETM) and receiver (ERM) modules, maintaining the electrical integrity of the entire PLC subsystem.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProfessional Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ACC201\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax PLC I\/O Expansion Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Bus Terminator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-pin D-type Serial Port Compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePlacement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\"Expansion Out\" Port of the Final Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mA (Fully Passive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C (-40 °F to 185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mm x 30 mm x 20 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC200ACC201 provides essential electrical stabilization for complex automation networks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Signal Reflection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed expansion buses suffer from \"signal bounce\" when they reach an open-ended port. The IC200ACC201 absorbs these residual waves, preventing them from traveling back up the cable and colliding with new data packets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable High-Speed Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis terminator maintains the specific characteristic impedance of the VersaMax expansion bus. This stability allows the system to operate at maximum baud rates across multiple racks without increasing the Bit Error Rate (BER).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsing a physical terminator plug in the final rack simplifies diagnostic routines. Technicians can instantly verify the physical limits of the I\/O bus, ensuring that the system logic matches the physical hardware layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Power Deployment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs a passive device, the IC200ACC201 requires no external power supply or software configuration. It functions purely through calibrated resistive circuitry, making it a maintenance-free addition to the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this GE Fanuc IC200ACC201 unit brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the IC200ACC201 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition. Each plug ships in original factory packaging to ensure that the internal resistive components and connector pins meet OEM tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIn which port should I install the IC200ACC201?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstall the IC200ACC201 into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"Expansion Out\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eport of the very last expansion rack in your daisy chain. Do not install it in middle racks or the main CPU rack unless that rack is the only node in the system and requires termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I forget to install the terminator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOperating a VersaMax expansion system without the IC200ACC201 often results in intermittent \"Loss of I\/O Module\" faults or \"Bus Communication\" errors. While the system might appear to work in short chains, signal reflections will eventually cause data corruption as you add more modules or experience electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this terminator work with VersaPoint or RX3i systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200ACC201 is specifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexpansion bus. Other GE or Emerson series use different connector styles and impedance ratings. Always use the terminator matched to your specific PLC hardware family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870856187994,"sku":"IC200ACC201","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/234.jpg?v=1776761473"},{"product_id":"ic200cpu002-versamax-0-4ms-scan-time-cpu-module","title":"IC200CPU002 VersaMax 0.4ms Scan Time CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC200CPU002 serves as the high-performance intelligence center for the VersaMax modular PLC system. This 32-bit RISC central processing unit manages complex automation sequences with an impressive scan rate of 0.4 ms per 1K of logic. Designed for scalability and speed, it handles up to 2048 digital I\/O points and 1024 analog I\/O points, making it the ideal choice for mid-to-large scale manufacturing, utility monitoring, and process control applications. The module integrates dual-port communication (RS-232 and RS-485) to provide versatile connectivity with HMI, SCADA, and peripheral devices.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProfessional Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200CPU002\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit RISC CPU (60 MHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42 KB Configurable (64 KB Total)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2048 Inputs \/ 2048 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1024 Inputs \/ 1024 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoolean Scan Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 ms per 1K of logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePort 1: RS-232 (9-pin D-sub); Port 2: RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSNP Slave, RTU Slave, Serial I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2A @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReal-Time Clock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in (0.01% Accuracy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC200CPU002 delivers high-speed processing and secure operational control for modern control cabinets:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Efficiency 32-Bit Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 60 MHz RISC processor executes complex mathematical instructions and PID loops with minimal latency. This hardware-level speed ensures that high-speed packaging or sorting lines maintain precise timing without jitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Protocol Communication Hub:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePort 1 (RS-232) and Port 2 (RS-485) operate simultaneously. This allows engineers to maintain a local HMI connection while communicating with a broader SCADA network or multi-drop RS-485 serial bus using RTU or SNP protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Memory Allocation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module offers 42 KB of user-configurable memory. Engineers can shift the balance between register storage and logic space to suit data-heavy applications (like logging) or logic-heavy sequences (like complex motion control).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Safety \u0026amp; State Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA dedicated manual Run\/Stop switch sits behind a protective door. This physical interlock prevents accidental software-triggered state changes during field maintenance, providing an additional layer of hardware-based security for plant personnel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this GE Fanuc IC200CPU002 unit 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the IC200CPU002 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition. Each CPU module ships in original factory packaging, ensuring all internal memory capacitors and the real-time clock battery remain at peak operational life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this CPU require a specific I\/O carrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200CPU002 installs onto a VersaMax CPU carrier (such as the IC200CHS001). This modular approach allows you to replace the CPU without disturbing the field wiring connected to the power supply or I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the battery life for the memory backup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated battery maintains the real-time clock and configurable user memory for approximately\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 years\u003c\/strong\u003e. We recommend checking the battery status during annual maintenance cycles to prevent data loss in the event of a prolonged power outage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this CPU with VersaMax Expansion racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The IC200CPU002 supports expanded I\/O architectures. By using expansion transmitter and receiver modules, this CPU can manage I\/O modules across multiple racks while maintaining the same 2048-point address space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42912556122202,"sku":"IC200CPU002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/235.jpg?v=1776761594"},{"product_id":"ge-fanuc-ic200cpue05-32-bit-risc-100mhz-controller","title":"GE Fanuc IC200CPUE05 32-Bit RISC 100MHz Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC200CPUE05-CG delivers high-speed processing and advanced networking capabilities to the VersaMax modular PLC platform. This CPU features a powerful 32-bit RISC processor clocked at 100 MHz, achieving an ultra-fast scan rate of 0.2 ms per 1K of logic. Designed as the flagship controller for Ethernet-centric automation, it manages up to 2048 discrete I\/O points and 512 analog I\/O points. The integrated 10\/100 Mbps Ethernet port eliminates the need for external communication modules, allowing the CPU to communicate directly with SCADA systems, HMIs, and other PLCs via industrial-standard protocols.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProfessional Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200CPUE05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit RISC (100 MHz clock)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 KB User Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 KB Configurable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2048 Inputs \/ 2048 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 Inputs \/ 512 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x RJ-45 (10\/100 Mbps)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x RS-232, 1x RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScan Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 ms per 1K Boolean logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP, SRTP, EGD, SNP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC200CPUE05 optimizes control architecture through superior hardware performance and connectivity:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed 100MHz Logic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 100 MHz RISC processor provides twice the clock speed of standard VersaMax units. This enables precise control over high-speed motion axes and complex mathematical algorithms required for chemical dosing or power utility monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Industrial Ethernet:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard RJ-45 port supports Ethernet Global Data (EGD) for peer-to-peer data sharing and SRTP for SCADA connectivity. This integrated approach reduces hardware costs and simplifies cabinet wiring by providing a direct network interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Serial Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn addition to Ethernet, the module includes RS-232 and RS-485 ports. Engineers utilize these for local HMI connections or legacy Modbus RTU device integration, ensuring the CPU acts as a comprehensive communication bridge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansive Memory Allocation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 64 KB of program memory and 64 KB of data memory, this CPU handles extensive data logging and complex recipe management. It allows for the storage of detailed diagnostic fault tables, improving localized troubleshooting capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the GE Fanuc IC200CPUE05 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the IC200CPUE05 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition. Each CPU module ships in factory-sealed packaging, ensuring the integrity of the internal electronics and the latest firmware revision for industrial use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the Ethernet port support Modbus TCP\/IP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200CPUE05 natively supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP (Client\/Server)\u003c\/strong\u003e, allowing it to communicate with a wide range of third-party sensors, drives, and control systems over a standard Ethernet network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich programming software should I use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou configure and program the IC200CPUE05 using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProficy Machine Edition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Logic Developer PLC). The software allows for easy setup of IP addresses, subnet masks, and industrial protocol parameters through its hardware configuration tool.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and the IC200CPU002?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200CPUE05 offers a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 MHz clock speed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(vs 60 MHz) and a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebuilt-in Ethernet port\u003c\/strong\u003e. It also provides higher memory capacity and faster scan times, making it the preferred choice for applications requiring network integration and higher processing throughput.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42912563462234,"sku":"IC200CPUE05","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/236.jpg?v=1776761780"},{"product_id":"ic200erm002-ge-fanuc-expansion-receiver-new-stock","title":"IC200ERM002 GE Fanuc Expansion Receiver | New Stock","description":"\u003ch2\u003eGE Fanuc IC200ERM002 VersaMax Expansion Receiver\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200ERM002\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ERM002\u003c\/strong\u003e Non-isolated Expansion Receiver Module, operates as a dedicated hardware component for multi-rack I\/O expansion within VersaMax PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ERM002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eNon-isolated Expansion Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 7 racks maximum (Max 8 modules per rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Speed\u003c\/td\u003e\n\u003ctd\u003e5 Mbps or 2.765 Mbps (Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Limits\u003c\/td\u003e\n\u003ctd\u003eMax 1 meter (Single); Max 15 meters total (Multi-rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Connectors\u003c\/td\u003e\n\u003ctd\u003eTwo 26-pin D-shell expansion ports (In \/ Out)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC and 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e70 mA @ 5 VDC; 20 mA @ 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax I\/O module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200ERM002 manages high-speed distributed datalink frames across expanded VersaMax subplanes, providing the raw backplane bus communication velocity needed to service remote racks without introducing phase lag into the central CPU scan. Supporting discrete I\/O density scaling up to 7 multi-drop racks, the module serializes local card registers into deterministic packets at 5 Mbps clock rates. Because this is a non-isolated hardware variant, the system relies on an unbroken, low-impedance master ground plane across the expansion bus to prevent localized common-mode ground transients from destabilizing the 26-pin D-shell data lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the layout consequences if the cumulative cable distance of a multi-rack network drops below or exceeds the 15-meter threshold?\u003c\/p\u003e\n\u003cp\u003eA: Exceeding the 15-meter total boundary causes signal attenuation and protocol frame corruption due to high-frequency reflection across the 5 Mbps datalink. The bus structure must be designed to stay within the 15-meter cumulative limit.\u003c\/p\u003e\n\u003cp\u003eQ: How does a sudden loss of logic power on an expansion rack affect the primary CPU rack configuration?\u003c\/p\u003e\n\u003cp\u003eA: When an expanded subplane loses power, the IC200ERM002 drops its active communication state. The main CPU registers an I\/O drop fault on that specific rack ID, logs a system backplane error, and executes the predefined fallback logic state.\u003c\/p\u003e\n\u003cp\u003eQ: Is it permissible to connect or disconnect the 26-pin D-shell expansion cables while the VersaMax system power is active?\u003c\/p\u003e\n\u003cp\u003eA: No. Physical handling or unseating of the D-shell interfaces under live conditions will create voltage spikes and pins arcing across the non-isolated bus, resulting in hardware damage or an immediate CPU watch fault.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Attachment and Ground Alignment:\u003c\/strong\u003e Snugly click the module housing onto a clean, unpainted 35 mm top-hat DIN rail profile. Tighten all grounding clamps to ensure direct metal-to-metal contact with the panel backplate to eliminate grounding offsets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD-Shell Interface Securement:\u003c\/strong\u003e Slide the 26-pin D-shell male connectors straight into the expansion ports. Hand-tighten the integrated retaining jack screws to prevent mechanical displacement from industrial vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Separation Restrictions:\u003c\/strong\u003e Route the high-frequency expansion bus cables through separate industrial wire trays away from high-current AC motor leads, variable frequency drive outputs, and inductive switching relays to block electromagnetic cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Thermal Maintenance:\u003c\/strong\u003e Position the expansion racks to allow at least 50 mm of vertical clearance above and below the ventilation grids, keeping the ambient air pocket strictly within the 0 to +60 deg C range.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42912576274522,"sku":"IC200ERM002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/237.jpg?v=1770779110"},{"product_id":"ic200gbi001-ge-fanuc-genius-interface-unit-new-stock","title":"IC200GBI001 GE Fanuc Genius Interface Unit | New Stock","description":"\u003ch2\u003eGE Fanuc IC200GBI001 Versamax Genius Network Interface Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200GBI001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200GBI001-GJ\u003c\/strong\u003e Genius Network Interface Unit, operates as a dedicated hardware component for distributed remote I\/O data exchange within Genius Bus networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200GBI001 (Part Number: IC200GBI001-GJ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eGenius Bus (Token-passing, Master\/Slave configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e1024 Inputs \/ 1024 Outputs maximum per node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Memory\u003c\/td\u003e\n\u003ctd\u003e128 Bytes Input \/ 128 Bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transmission Rates\u003c\/td\u003e\n\u003ctd\u003e153.6 Kbaud (Extended), 153.6 Kbaud, 76.8 Kbaud, 38.4 Kbaud (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Address Range\u003c\/td\u003e\n\u003ctd\u003eSerial Bus Address (SBA) 0 to 31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 expansion racks (64 I\/O modules total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Current Draw\u003c\/td\u003e\n\u003ctd\u003e250 mA @ 5 VDC; 10 mA @ 3.3 VDC (From backplane power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Resistance Options\u003c\/td\u003e\n\u003ctd\u003eHardwired or selectable: 75, 100, 120, or 150 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200GBI001 interface architecture acts as a local slave sub-controller to scale I\/O density by multiplexing up to 1024 discrete data points and 128 bytes of analog variables onto a single node. The module internal logic processes subplane registers locally, converting I\/O states into time-critical tokens optimized for standard Genius Bus transmission profiles. To maintain deterministic data tracking across extended topologies, the internal bus transceiver provides dual physical cabling paths for serial network line redundancy. Built-in selectable termination networks (75 to 150 ohms) allow field matching of transmission line impedance, safeguarding backplane bus communication velocity against data reflections and electromagnetic packet dropouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the physical network address determined and modified on the IC200GBI001 hardware interface?\u003c\/p\u003e\n\u003cp\u003eA: The Serial Bus Address (SBA) configuration must be set using a handheld monitor or through the software configuration profile via the backplane interface. The physical hardware lacks external rotary switches to protect against accidental address modifications during runtime.\u003c\/p\u003e\n\u003cp\u003eQ: What actions does the network interface execute if one of the redundant Genius Bus cabling channels drops connection?\u003c\/p\u003e\n\u003cp\u003eA: The internal communications engine monitors data lines continuously. If Bus A fails, the logic switches data traffic to Bus B without disrupting the current I\/O cycle or altering the local state registers, concurrently setting the front-panel diagnostic LED to flag a line fault.\u003c\/p\u003e\n\u003cp\u003eQ: Is it permissible to insert or extract adjacent I\/O modules from the Versamax rack plane while the IC200GBI001 is actively updating network tokens?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The Versamax backplane structure supports online hot-swapping of standard I\/O modules. However, the IC200GBI001 interface unit itself must remain powered and docked to prevent a total drop of the remote node data block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Mounting Alignment and Earthing:\u003c\/strong\u003e Seat the module chassis securely onto a clean 35 mm top-hat DIN rail track. Fasten the integrated grounding clip straight onto an unpainted metallic panel backplate to maintain a low-impedance path for electrical noise diversion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius Bus Wiring Configuration:\u003c\/strong\u003e Connect the incoming serial data pair using approved shielded twisted-pair cables designed for Genius communication networks. Maintain a precise daisy-chain pattern from node to node, avoiding star or T-tap branching configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistor Termination Verification:\u003c\/strong\u003e Activate the proper hardware termination resistance at the two physical ends of the trunk segment. Verify that intermediate nodes have their termination mechanisms isolated to avoid overloading the physical layer transceivers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvective Thermal Boundaries:\u003c\/strong\u003e Allow at least 50 mm of vertical clearance boundary space around the rack housing. Maintain a continuous airflow pattern inside the cabinet enclosure to keep the local operating pocket within the 0 to +60 deg C limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42912622542938,"sku":"IC200GBI001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/242.jpg?v=1770780843"},{"product_id":"ic200mdd840-ge-fanuc-plc-discrete-mixed-module-new","title":"IC200MDD840 GE Fanuc PLC Discrete Mixed Module New","description":"\u003cp\u003e\u003cstrong\u003eGE Fanuc VersaMax IC200MDD840 Discrete Mixed I\/O Module 20ID\/12OR\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDD840 (Part Number: IC200MDD840)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density discrete mixed I\/O module from the VersaMax series, designed to provide a versatile and space-saving solution for industrial control systems. This module combines both input and output capabilities in a single unit, featuring 20 discrete inputs and 12 relay outputs. It is engineered for applications requiring a mix of 24 VDC positive logic sensing and high-current relay switching.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDD840\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ediscrete inputs are divided into three groups, supporting standard 24 VDC input signals with positive logic (sourcing). The 12 relay outputs provide isolated switching for both AC and DC loads, supporting voltages up to 240 VAC or 125 VDC. With a substantial 2.0 Amp current rating per output point, this module is capable of directly driving solenoids, motor starters, and heavy-duty indicators without the need for interposing relays in many scenarios. The modular design of the VersaMax line allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDD840\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto be easily installed on a variety of terminal bases for flexible field wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHardware parameters and electrical ratings for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDD840\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIC200MDD840\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Mixed Module (Input\/Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Points (24 VDC Positive Logic\/Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Points (Relay, Normally Open)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Range: 0 to +30 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Load Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5\/24\/125 VDC or 120\/240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 Amps maximum per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current (Total)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 Amps maximum per module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC (Output to Backplane\/Frame Ground)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V Output: 90mA; 3.3V Output: 10mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5ms (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15ms maximum (Turn on\/off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 lbs (0.16 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42912697188442,"sku":"IC200MDD840","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/165..jpg?v=1770789261"},{"product_id":"ic200mdl241-ge-fanuc-plc-16-channel-240vac-input-module","title":"IC200MDL241 GE Fanuc PLC 16-Channel 240VAC Input Module","description":"\u003ch3\u003e\u003cstrong\u003eGE Fanuc VersaMax IC200MDL241 240VAC 16-Point Discrete Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL241 (Part Number: IC200MDL241)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density discrete input module within the VersaMax I\/O family, specifically engineered for high-voltage AC sensing applications. This module provides 16 input points designed to interface directly with field devices operating at a nominal 240 VAC, such as heavy-duty limit switches, pushbuttons, and selector switches. It functions by converting these high-voltage AC signals into logic-level data for the VersaMax CPU or Network Interface Unit (NIU).\u003c\/p\u003e\n\u003cp\u003eDesigned for efficient cabinet layout, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL241\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eorganizes its 16 points into two isolated groups of eight. This grouping allows for 1500 VAC isolation between sets, providing essential protection for the PLC backplane and adjacent modules from electrical noise or voltage spikes. The module supports hot-swapping, enabling rapid replacement without powering down the entire rack, which significantly reduces maintenance downtime. Each channel is equipped with a dedicated LED on the front panel, allowing for instantaneous visual verification of the input status during commissioning and troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHardware parameters and operational limits for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL241\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIC200MDL241\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete AC Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Grouped in 2 sets of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 264 VAC (47–63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e155 to 264 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOff-State Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 40 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.0 mA to 11.0 mA (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOff-State Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 2.0 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 ms maximum (On and Off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC (Group-to-Group); 2500 VAC (I\/O to Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 mA @ 5V (Maximum from backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +70 °C (-40 °F to 158 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.61 lbs (0.28 kg) Net; 0.5 kg Shipping\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42912697614426,"sku":"IC200MDL241","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/166..jpg?v=1770789758"},{"product_id":"ic200chs002-versamax-industrial-terminal-block-carrier","title":"IC200CHS002 VersaMax Industrial Terminal Block Carrier","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the essential mechanical and electrical foundation for the GE VersaMax modular I\/O system. This box-style carrier provides the interface between a single I\/O module and the field wiring. Its integrated design eliminates the need for separate terminal blocks, streamlining panel space in high-density distributed control applications. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring maximum lifecycle reliability for your automation architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCarrier Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBox-Style Terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Terminals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 (A1–A18, B1–B18)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 264 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Per Point\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Amperes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Power\/Ground Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Amperes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size (Single)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAWG #14 to AWG #22\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size (Dual)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAWG #18 (shorting)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Screw-clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Resistant Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated box-style terminals utilize secure screw-clamp mechanisms. These connections prevent signal loss in high-vibration environments typical of OEM machinery and heavy industrial floors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Modular Assembly:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier snaps directly onto a standard 35mm DIN rail. The design allows users to replace I\/O modules without disturbing the field wiring, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a rating up to 264 VAC, this carrier accommodates both high-voltage discrete signals and low-voltage analog inputs, providing a universal platform for diverse sensor types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe horizontal mounting profile maintains critical clearance (2 inches top\/bottom) to ensure natural convection cooling, protecting the internal electronics of the docked I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC200CHS002 support hot-swapping of I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the carrier provides the physical interface, hot-swapping depends on the specific VersaMax CPU or Network Interface Unit (NIU) capabilities. Always verify system power requirements before removing modules to prevent data corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the IC200CHS002 and a \"barrier-style\" carrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200CHS002 (Box-Style) features recessed terminals which offer better finger safety and a more compact footprint. Barrier-style carriers use exposed screw terminals which are often preferred for ring-lug connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mount this carrier vertically?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGE Fanuc specifies horizontal mounting for the IC200CHS002. Vertical mounting alters the thermal dissipation profile and may derate the current capacity of the attached I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with Emerson-branded VersaMax modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Since Emerson acquired GE Fanuc’s automation division, all IC200 series components remain fully interchangeable between GE Fanuc and Emerson branding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217710907482,"sku":"IC200CHS002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/497._8312f836-7264-4f01-845f-3b5e530bc7bd.jpg?v=1776214694"},{"product_id":"ge-ic200chs022-36-terminal-compact-i-o-base-module","title":"GE IC200CHS022 36-Terminal Compact I\/O Base Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS022\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the primary mounting and wiring interface for the GE VersaMax modular system. Unlike standard horizontal units, this carrier utilizes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVertical Orientation\u003c\/strong\u003e, mounting perpendicular to the DIN rail to maximize rail density and accommodate tall enclosure profiles. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging, ensuring seamless integration into your distributed control systems (DCS) or OEM machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Compact\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical (Perpendicular to DIN rail)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated IEC Box-Style\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Terminals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 (Supports 32 I\/O + 4 Common\/Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC (Internal Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e66.8 mm x 163.5 mm x 70 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Mounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm x 7.5mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Space Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe vertical design reduces the horizontal footprint on the DIN rail. This allows engineers to pack more I\/O points into narrow control cabinets where width is at a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTool-less Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated carrier-to-carrier connectors link the backplane signals automatically as you slide the units together. This eliminates the need for external ribbon cables or complex bus jumpers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Keying Mechanism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach carrier includes a module keying system. This prevents the insertion of the wrong I\/O module type into a wired base, protecting field sensors and internal circuitry from voltage mismatches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Vibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IEC-style box terminals provide high-pressure contact points. These terminals grip field wires securely, preventing intermittent signals in high-vibration applications like reciprocating machinery or mobile industrial platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified EMC Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier grounds directly through the DIN rail interface. This ensures robust electromagnetic compatibility (EMC) without requiring additional manual grounding straps for every module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix IC200CHS022 vertical carriers with horizontal carriers in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The physical dimensions and bus connector alignments differ. You must maintain a consistent mounting orientation (all vertical or all horizontal) within a single I\/O station to ensure proper backplane communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum wire gauge supported by the box terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200CHS022 typically accommodates solid or stranded copper wire between AWG #14 and AWG #22. Always refer to your specific I\/O module manual for the recommended current-carrying capacity of the wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this carrier require a separate power supply connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe carrier receives its 5V logic power via the VersaMax backplane from the Power Supply\/NIU. However, you must connect field power and commons to the designated terminals (usually 4 of the 36) to power your field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure the carrier is properly grounded?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe carrier establishes a ground connection through its DIN rail clip. You must use a zinc-plated yellow chromate steel DIN rail and ensure the rail itself connects to the cabinet's functional earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217741021274,"sku":"IC200CHS022","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/498._c01d5a1b-747c-4297-89b9-06c3793fe11e.jpg?v=1776214971"},{"product_id":"buy-new-ge-fanuc-ic200cpu001-plc-central-processing-unit","title":"Buy New GE Fanuc IC200CPU001 PLC Central Processing Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CPU001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-performance brain of the GE VersaMax PLC system. This compact processor manages up to 2048 discrete I\/O points and provides 34KB of configurable user memory for logic and data storage. It integrates dual communication ports (RS-232 and RS-485) directly into the module, allowing simultaneous connection to programming terminals and HMI devices. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control architecture benefits from maximum computational stability and factory-certified performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e34K Bytes (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2048 Inputs \/ 2048 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoolean Execution Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.8 ms per 1K of logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePort 1: RS-232 \/ Port 2: RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSNP Slave, RTU Slave, Serial I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Storage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Flash and Battery-Backed RAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFloating Point Math\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware Supported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReal-Time Clock (RTC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated (100ppm Accuracy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140mA @ 5V \/ 100mA @ 3.3V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Scan Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CPU001 achieves a rapid scan rate of 1.8 milliseconds per 1K of Boolean logic. This speed minimizes processing latency in high-speed packaging and assembly applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Memory Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers can allocate the 34KB of internal memory across program logic, registers, and analog words. This flexibility allows the CPU to handle data-intensive tasks or complex PID loops without requiring additional memory modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Dual-Protocol Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe inclusion of an RS-232 port for SNP programming and an RS-485 port for Modbus RTU Slave functionality eliminates the cost of external communication bridge modules. It facilitates direct integration with third-party drives and sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Integrity Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes battery-backed RAM combined with non-volatile System Flash. This dual-layer approach prevents program loss during extended power outages and ensures the PLC resumes operations immediately upon power restoration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt only 66.8 mm wide, the IC200CPU001 fits into tight control panels. It supports the full range of VersaMax expansion racks, allowing the system to grow from a few points to over 2,000 I\/O points while maintaining the same CPU platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC200CPU001 support floating-point mathematics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This CPU natively supports floating-point data, enabling complex calculations for flow control, positioning, and advanced analog scaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the EZ Store device mentioned in the specs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EZ Store is an optional plug-in module used for rapid program transfer and updates without a PC. When attached, the CPU's 5V backplane current consumption increases from 40mA to 140mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I program this unit using Ladder Diagram (LD)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The IC200CPU001 supports both Ladder Diagram and Instruction List (IL) programming languages via Proficy Machine Edition or VersaPro software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the battery included for the Real-Time Clock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPU features a battery-backed RTC and RAM. For new installations, ensure the battery is active or replaced to maintain clock accuracy (+\/- 9 seconds per day) and data retention during power-off cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217747574874,"sku":"IC200CPU001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/1._e4fc9028-4338-4e59-b4a9-39a2fb493220.jpg?v=1776215347"},{"product_id":"versamax-micro-28-point-expansion-new-ic200uex214-ge-fanuc","title":"VersaMax Micro 28-Point Expansion New | IC200UEX214 GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UEX214\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly extends the capabilities of the VersaMax Micro PLC family by adding 28 discrete I\/O points to a single controller base. This expansion unit integrates 16 digital inputs and 12 transistor outputs, all operating on a standard 24 VDC platform. It provides the necessary density for mid-sized automation tasks without requiring a full rack-based PLC migration. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compatibility with your existing VersaMax Micro architecture and long-term field reliability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Inputs (24 VDC, Positive\/Negative Logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Outputs (24 VDC Transistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (5 Watts Consumption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Power Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 mA at 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExpansion Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports 1–4 units per Micro PLC base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.91 kg (2.00 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200UEX214 packs 28 I\/O points into a compact chassis. This allows machine builders to increase sensor and actuator counts in constrained electrical enclosures where space is at a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBi-Directional Input Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 digital inputs support both sink and source (positive\/negative) logic. This flexibility allows engineers to interface with a wide variety of field devices, including NPN\/PNP proximity sensors and dry contacts, without adding interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Sensor Powering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit provides a dedicated 200 mA sensor power supply at 24 VDC. This feature simplifies wiring by allowing the expansion unit to power local sensors directly, reducing the need for external distribution blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Logic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned specifically for real-time control, the expansion unit maintains high-speed communication with the Micro PLC base. It ensures minimal signal propagation delay for time-critical OEM machinery applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe modular design supports the daisy-chaining of up to four expansion units per controller. This allows the system to scale incrementally as machine requirements evolve, protecting the initial investment in control hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200UEX214 operate as a standalone controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200UEX214 is a dedicated expansion unit. It requires a connection to a VersaMax Micro PLC base controller to function, as it does not possess an independent CPU for logic execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of protection is required for the transistor outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTransistor outputs are susceptible to overcurrent and inductive surges. We strongly recommend installing external fusing for each output circuit and using flyback diodes when switching inductive loads like solenoid valves or DC contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 24 VDC power supply included for the inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit requires an external 24 VDC power source to operate. However, it does provide a regulated 200 mA output specifically to power field sensors, which helps reduce the load on your primary system power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with both GE Fanuc and Emerson-branded VersaMax Micro PLCs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Despite the brand transition from GE Fanuc to Emerson, the IC200UEX214 remains fully compatible across all generations of the VersaMax Micro series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217752391770,"sku":"IC200UEX214","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/2._f70be8c6-8c1f-4c50-8d65-a30be586a960.jpg?v=1776215643"},{"product_id":"ic200acc414-ge-fanuc-versamax-plc-lithium-battery","title":"IC200ACC414 GE Fanuc VersaMax PLC Lithium Battery","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC414\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the critical safeguard for program integrity and temporal accuracy within the GE VersaMax Micro PLC range. This cylinder-type lithium battery provides independent power to the CPU’s volatile RAM and Real-Time Clock (RTC) whenever the primary system power fails. We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your controllers maintain their logic states, register data, and time-stamped logs through extended downtime or transport.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Energy Lithium (Cylinder Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.6 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e790 mAh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackup Duration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 7 Years (dependent on environmental factors)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShelf Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Years at 30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20, 23, 28, 40, and 64-Point VersaMax Micro PLCs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRAM Backup and Real-Time Clock (RTC) Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05 lbs (Unit weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Data Retention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 790mAh high-capacity cell ensures that the CPU retains user programs and register data for up to 7 years. This long-term reliability eliminates the risk of memory wipes during seasonal facility shutdowns or long-distance machine shipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronized Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ACC414 powers the Real-Time Clock, allowing the PLC to execute time-critical logic and precise event logging immediately upon power-up without manual clock synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Micro Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis single battery model supports the entire VersaMax Micro spectrum, from the entry-level 20-point units to the high-density 64-point controllers. This standardization simplifies inventory management for maintenance departments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePassive Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnce installed in the dedicated CPU battery slot, the module requires no further configuration. The PLC hardware automatically switches to battery power the instant backplane voltage drops below the functional threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePredictable Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 5-year shelf life at 30°C, facilities can stock replacement units without fear of immediate degradation, facilitating proactive preventative maintenance schedules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I replace the IC200ACC414 battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the battery can last up to 7 years, we recommend replacement every 3 to 5 years depending on the ambient temperature of the cabinet. High-temperature environments accelerate lithium discharge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace the battery while the PLC is powered on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Replacing the battery while the CPU receives power (Hot-Swapping) prevents memory loss during the swap. Always ensure the \"Battery Low\" LED is monitored via the CPU diagnostic software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWill the PLC lose its program if the battery dies while the power is OFF?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the battery fails while the system is unpowered, the volatile RAM will clear, resulting in the loss of the user program and register values. Always back up your logic to System Flash to prevent permanent data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this battery require special disposal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. As a lithium-based component, you must dispose of the IC200ACC414 according to local environmental regulations for hazardous waste. Never incinerate or puncture the battery casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217767235674,"sku":"IC200ACC414","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/499._d91ecf74-3249-46cc-a5a1-349facf219e7.jpg?v=1776215945"},{"product_id":"ge-ic200mdl331-versamax-isolated-ac-output-original","title":"GE IC200MDL331 VersaMax Isolated AC Output Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL331\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides eight isolated channels of discrete AC output for the VersaMax PLC platform. Operating at a nominal 120VAC, each channel delivers up to 2.0 Amperes of current, making it ideal for driving heavy-duty industrial solenoids, motor starters, and large indicator lamps. We offer this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system operates with factory-certified switching precision and robust channel isolation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete AC (Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 to 132 VAC (47–63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent per Channel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 A (Maximum) \/ 0.5 A (Minimum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Leakage Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 2 mA at 132 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current (5V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 mA (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e½ Cycle (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Snubber and MOV for each output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC (1 minute) Channel-to-Channel \/ Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndividual Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200MDL331 isolates each of the eight outputs individually. This architecture allows the module to switch different AC phases or separate power sources within a single module, eliminating the need for multiple interposing relays or additional hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Load Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile standard PLC outputs often struggle with high-current demands, this module supports 2.0 Amperes per point. It directly controls large inductive loads, reducing cabinet complexity and wiring costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Surge Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery output contains a built-in Snubber circuit and Metal Oxide Varistor (MOV). These components absorb transient voltage spikes generated by inductive switching, protecting both the module’s internal circuitry and the connected field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Logic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical couplers separate the field-side AC voltage from the low-voltage PLC backplane logic. This provides up to 1500 VAC of protection, ensuring that field faults do not propagate to the CPU or other sensitive modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Diagnostic LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel LEDs provide immediate visual confirmation of output status. An additional \"OK\" LED monitors module health, significantly accelerating troubleshooting during commissioning or maintenance cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the IC200MDL331 with DC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module utilizes triac-based switching designed specifically for AC circuits (85-132 VAC). Attempting to switch DC loads will result in the output failing to turn off once energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 0.5A minimum load requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTriacs require a minimum holding current to stay in the \"ON\" state. If your load (such as a small LED indicator) draws less than 0.5A, the output may flicker or fail to latch. In such cases, you must install a parallel bleeder resistor to increase the current draw.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws 85mA from the backplane for logic operation, but the power used to drive the loads must come from an external AC source (85-132 VAC) wired to the isolated terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does individual isolation help in a multi-phase system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause each channel is isolated from the others, you can wire Channel 1 to Phase A and Channel 2 to Phase B without causing a short circuit. This is highly effective for controlling motors or devices across different power legs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217770741850,"sku":"IC200MDL331","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/500._a205379f-2e2a-4155-b769-675df47b1be3.jpg?v=1776216208"},{"product_id":"versamax-micro-communication-adapter-ge-ic200acc415","title":"VersaMax Micro Communication Adapter | GE IC200ACC415","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC415\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized communication bridge designed exclusively for the VersaMax Micro and Nano PLC series. This converter adapts the standard RS-232 serial port of the controller to an RS-485 interface, enabling long-distance networking and multi-drop configurations. While some documentation classifies this series as a battery pack, the IC200ACC415 is specifically the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-232 to RS-485 Converter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired for expanded serial connectivity. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring reliable data transmission for your industrial network.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro \/ Nano\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConverter Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 to RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro and Nano CPUs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRequired Cables\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200CBL500 or equivalent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDraws power from the PLC port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnects directly to the serial port interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnables multi-drop networking and long-distance serial comms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05 lbs (Unit weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Distance Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard RS-232 limits communication to short distances (typically 15 meters). The IC200ACC415 converts this signal to RS-485, allowing robust data transmission over distances up to 1200 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Drop Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy converting to RS-485, this adapter allows a single master device to communicate with multiple VersaMax Micro\/Nano PLCs on a single twisted-pair bus, reducing wiring complexity and port requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero External Power Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe converter draws its operating voltage directly from the PLC’s serial port pins. This eliminates the need for external power supplies or additional DIN rail wiring, maintaining a clean cabinet layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned specifically for the VersaMax form factor, the IC200ACC415 snaps into place without requiring custom mounting brackets. It ensures a secure, vibration-resistant physical connection to the CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy System Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis converter provides a vital link for maintaining and expanding legacy VersaMax Micro systems, allowing them to interface with modern RS-485 HMIs, SCADA gateways, and third-party Modbus RTU devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC200ACC415 require a specific cable for connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To ensure proper signal pinout and shielding, you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CBL500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable or a precisely engineered equivalent. Using standard off-the-shelf serial cables may result in communication failure or port damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with the VersaMax Modular (non-Micro) CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200ACC415 is engineered specifically for the physical and electrical port specifications of the VersaMax\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicro\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNano\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. For modular CPUs like the IC200CPU001, use the integrated RS-485 port or the appropriate modular serial expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this converter for Modbus RTU communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. By converting the physical layer to RS-485, you can utilize the Modbus RTU Slave or Master protocols supported by the VersaMax Micro firmware for multi-device industrial networking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the IC200ACC415 a replacement for a backup battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThere is often confusion in cross-references; however, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC415\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a communication converter. If you require RAM and clock backup, refer to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC414\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elithium battery. Always verify your part number against the hardware manual before purchase.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217773232218,"sku":"IC200ACC415","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/3._b15aeed5-aba3-4865-9ff6-28603012aeef.jpg?v=1776216881"},{"product_id":"ic200udd220-versamax-micro-plus-ethernet-communication-set","title":"IC200UDD220 VersaMax Micro PLUS Ethernet Communication Set","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UDD220\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance, compact Central Processing Unit within the VersaMax Micro PLUS lineup. This controller integrates 20 local I\/O points (12 DC inputs and 8 DC sink outputs) into a single, space-saving chassis. By pairing this unit with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UEM001 Ethernet Module\u003c\/strong\u003e, users gain high-speed networking capabilities alongside robust discrete control. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing a factory-fresh solution for demanding OEM machinery and distributed automation architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro PLUS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Onboard I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Inputs (24 VDC, Positive\/Negative Logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Outputs (24 VDC Transistor Sink)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200UEM001 (Ethernet) included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExecution Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFast cycle time for real-time applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExpansion Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports additional VersaMax Micro expansion modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork-Ready Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe included IC200UEM001 Ethernet module elevates the controller's connectivity. It enables seamless integration into factory-wide networks, allowing for remote diagnostics, SCADA interfacing, and peer-to-peer PLC communication via Modbus TCP or SRTP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogic Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 12 digital inputs support both positive and negative logic (Sink\/Source). This adaptability allows engineers to interface the controller with a diverse range of field sensors—such as proximity switches and encoders—without requiring additional signal conditioning hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Transistor Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8 transistor sink outputs handle rapid, repetitive switching cycles that would prematurely wear out mechanical relays. These outputs drive 24VDC solenoids, actuators, and pilot lights with high precision and zero contact bounce.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Scaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"Micro\" footprint minimizes required panel depth and width. Even with the Ethernet module attached, the system maintains a compact profile, while the expansion port allows for the addition of further I\/O modules as system complexity grows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Hardware Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe design incorporates industrial-grade shielding to resist electromagnetic interference (EMI). To ensure long-term field stability, we recommend external fusing for the transistor outputs to protect against accidental overcurrent or short-circuit events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the \"Micro\" and \"Micro PLUS\" models like the IC200UDD220?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Micro PLUS series offers enhanced execution speeds, larger memory capacity, and superior communication options compared to the standard Micro series. It specifically supports advanced expansion modules like the IC200UEM001 Ethernet module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate power supply for the Ethernet module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200UEM001 module draws its operating power directly from the PLC controller's expansion port. However, ensure your 24VDC system power supply provides sufficient current to cover both the controller logic and the Ethernet communication circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure the 8 outputs for Source logic instead of Sink?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200UDD220 features hardware-defined\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSink\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransistor outputs. If your application specifically requires Source logic (PNP), you must use an interposing relay or select a different VersaMax model, such as one with relay or source-type outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this controller compatible with older GE Fanuc expansion modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200UDD220 maintains backward compatibility with the standard VersaMax Micro expansion family, allowing you to mix and match digital, analog, and specialty modules to fit your specific I\/O requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217782669402,"sku":"IC200UDD220","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/4._1ece0a72-903b-498e-8f9f-e8da79adf3f4.jpg?v=1776217190"},{"product_id":"ge-ic200udd164-24vdc-40-input-24-output-controller","title":"GE IC200UDD164 24VDC 40-Input 24-Output Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UDD164\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the high-density pinnacle of the GE VersaMax Micro PLC family. This all-in-one controller integrates a powerful CPU with a massive onboard I\/O count, featuring 40 digital inputs and 24 DC source transistor outputs. Designed for complex OEM machinery and standalone factory automation, it eliminates the need for multiple expansion racks in mid-sized applications. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical control loops run on factory-certified hardware with maximum mean time between failures (MTBF).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 Inputs (24 VDC, Sink\/Source Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Outputs (24 VDC Transistor Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 mA per input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 \/ RS-485 Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExpansion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports VersaMax Micro Expansion Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExecution Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptimized for real-time logic and high-speed counting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnrivaled I\/O Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200UDD164 provides 64 onboard I\/O points within a single compact chassis. This high density significantly reduces DIN rail requirements and allows engineers to manage complex machines with dozens of sensors and actuators using a single controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSource-Type Transistor Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 24 DC source outputs simplify wiring for positive-logic industrial environments. These transistor outputs provide high-speed switching and eliminate the mechanical wear associated with relay-based controllers, making them ideal for high-frequency solenoid and pilot light control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Input Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 40 digital inputs accommodate both positive and negative logic. This flexibility allows the PLC to interface seamlessly with a mix of NPN and PNP sensors, reducing the need for interposing relays or signal converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Communication Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated RS-232 and RS-485 ports support multiple protocols for HMI interfacing and multi-drop networking. This enables the IC200UDD164 to serve as a central hub in a distributed control architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Scaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 64-point capacity handles most mid-range tasks, the unit remains fully compatible with the VersaMax Micro expansion line. You can easily add analog or additional digital modules via the expansion port to meet evolving machine specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between \"Source\" and \"Sink\" outputs in the IC200UDD164?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200UDD164 features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSource\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutputs, meaning the PLC provides the positive (+) 24VDC signal to the load. This is the industry standard for European and North American machinery to ensure safety and simplify troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I program the IC200UDD164 using modern software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This controller supports programming via Proficy Machine Edition (PME). It maintains full compatibility with existing VersaMax Micro logic, allowing for easy migration from older Micro series controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I protect the transistor outputs from damage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTransistor outputs are sensitive to overcurrent and short circuits. We strongly recommend installing external fast-acting fuses for each output group. For inductive loads like solenoids, always use suppression diodes to prevent back-EMF spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit require a specific power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200UDD164 requires a stable 24VDC power source. Ensure your power supply has sufficient wattage to handle the CPU logic plus the total current draw of the 24 transistor outputs and any attached expansion modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217795350618,"sku":"IC200UDD164","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/5._b15454e9-ed29-440d-a66c-eafce8ce13e2.jpg?v=1776217515"},{"product_id":"discrete-output-module-5a-total-capacity-original-ic200mdl744","title":"Discrete Output Module 5A Total Capacity Original | IC200MDL744","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL744\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-density discrete control for the VersaMax PLC platform, featuring 32 independent DC transistor outputs. This module operates using negative logic (current sinking) and supports a versatile voltage range of 5V, 12V, or 24V DC. It serves as a critical component for distributed control systems requiring a high concentration of output points in a compact footprint. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-speed switching performance and full compatibility with your existing VersaMax I\/O carriers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Output (Transistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNegative Logic (Sinking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC \/ 12 VDC \/ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per point (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Module Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 A (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFast switching for real-time logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDraws from VersaMax I\/O Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (Horizontal or Vertical with carrier)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.98 lbs (0.45 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Channel Count:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200MDL744 packs 32 discrete outputs into a single module width. This architecture drastically reduces the number of I\/O carriers required in the cabinet, lowering hardware costs and saving valuable DIN rail space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMixed Voltage Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard modules restricted to 24VDC, the IC200MDL744 supports 5V and 12V logic levels. This capability allows the PLC to interface directly with TTL logic circuits, specialized sensors, and varying industrial DC bus voltages without interposing signal conditioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Negative Logic (Sinking):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transistor design utilizes negative logic (sinking current to the common), which is often preferred for specific electronic interfacing and NPN-style device control. This ensures clean, fast switching with minimal heat dissipation per point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Switching Speed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransistor-based outputs eliminate the mechanical delay associated with relay modules. The IC200MDL744 handles high-frequency cycling and real-time response tasks, making it ideal for packaging, sorting, and high-speed valve control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module plugs directly into a standard VersaMax I\/O carrier. This design separates the field wiring from the active electronics, allowing users to replace the module without disturbing the terminal block connections, which significantly reduces Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between Sinking (Negative Logic) and Sourcing outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200MDL744 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSinking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule (Negative Logic). The load connects between the positive power supply and the module output. When the output turns on, the module completes the circuit to the negative common (ground). Ensure your field devices are compatible with NPN-style switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different voltages on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module supports 5V, 12V, or 24V DC, you must apply the same external power supply voltage to a single power group. Always consult the wiring diagram for the specific carrier you are using to ensure proper voltage isolation between points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat protection should I use for the transistor outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTransistor outputs lack the inherent robustness of relays against short circuits. You must use external fast-acting fuses to protect the IC200MDL744 from overcurrent. For inductive loads (solenoids, DC motors), always install flyback diodes to prevent voltage spikes from damaging the transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module a direct replacement for the IC200MDL744G?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"G\" suffix (and other version letters) typically denotes a minor hardware revision or a change in manufacturer branding (GE Fanuc to Emerson). The fundamental specifications and fitment remain identical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217801379930,"sku":"IC200MDL744","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/6._f37cc271-adfa-4902-a3f6-283401bc2117.jpg?v=1776218307"},{"product_id":"ge-ic200alg261-10vdc-differential-analog-input-15-bit","title":"GE IC200ALG261 ±10VDC Differential Analog Input 15-Bit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG261\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision interface for industrial sensors, providing eight differential analog input channels for the VersaMax PLC platform. This module specializes in measuring voltage signals within the ±10VDC range, utilizing high-resolution conversion to translate process variables into actionable data. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system maintains superior signal fidelity and long-term stability in demanding process environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Differential Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to +10 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15-Bit \/ 16-Bit (0.3125 mV per LSB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 milliseconds (all channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 100 Ohms (Minimum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,500 VAC (Channel-to-Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V DC (Consumes 200mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne Green \"OK\" LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShielded Twisted Pair (STP) Recommended\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSnaps onto VersaMax I\/O Carriers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Signal Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ALG261 provides up to 15-bit (plus sign) resolution, allowing the PLC to detect minute voltage fluctuations as small as 0.3125 mV. This precision proves vital for applications like chemical dosing, precision tension control, and sophisticated laboratory monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDifferential Inputs\u003c\/strong\u003e, this module effectively cancels out common-mode noise often found in long cable runs or electrically noisy factory environments. This ensures the CPU receives the \"true\" signal rather than electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Process Updates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA total module update rate of 7.5ms enables the controller to respond quickly to dynamic process changes. This speed supports real-time closed-loop control for fast-moving machinery and critical safety limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 1,500 VAC isolation between the field-side inputs and the backplane logic. This barrier protects the expensive CPU and other rack modules from high-voltage transients or ground loops occurring at the sensor level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated \"OK\" LED offers immediate visual confirmation of module health. The module communicates specific fault conditions (such as loss of backplane power) to the CPU, streamlining the troubleshooting process for maintenance teams.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the IC200ALG261 over a single-ended analog module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200ALG261 uses differential wiring, which requires two leads per signal (plus a shield). This configuration suppresses electrical noise that affects both wires equally, making it significantly more reliable than single-ended modules in heavy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the IC200ALG261 for 4-20mA current loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200ALG261 is primarily a voltage input module (±10V). While you can technically measure current by installing a precision shunt resistor across the terminals, we recommend using a dedicated current module like the IC200ALG262 for 4-20mA applications to ensure factory-calibrated accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200ALG261 draws its 5VDC operating power directly from the VersaMax backplane. However, the sensors connected to the inputs typically require their own external power source depending on the instrument type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should I ground the shielded cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo maximize EMI protection, connect the cable shields to the carrier's frame ground. GE Fanuc recommends grounding the shield at only one end (usually the PLC side) to prevent ground loops that could distort the analog signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217817665626,"sku":"IC200ALG261","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/7._17235062-b2bb-4f78-9e2a-ca8b1bd649b9.jpg?v=1776218862"},{"product_id":"devicenet-master-supports-40-slave-devices-ic200bem103","title":"DeviceNet Master Supports 40 Slave Devices | IC200BEM103","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200BEM103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a powerful communication gateway for the VersaMax PLC platform, enabling seamless integration into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeviceNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetworks. This module provides versatile functionality by operating as either a DeviceNet Master (Scanner) or a Slave device. It allows a VersaMax CPU to control up to 40 remote slave devices or exchange critical process data with a larger supervisory network. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-speed data throughput and robust network stability for your distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet (Master or Slave)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNodes Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 64 nodes (without bridging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlave Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControls up to 40 slave devices in Master mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 Kbaud, 250 Kbaud, 500 Kbaud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Exchange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 Bytes Input\/Output total\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140 mA @ 5V DC (from backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRequired Carrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200CHS006 (Communication Carrier)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic LEDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Status, Module Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Role Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200BEM103 eliminates the need for separate hardware for different network roles. You can configure it as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMaster\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto manage remote drives and I\/O blocks, or as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSlave\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto present the VersaMax PLC as a component within a larger Allen-Bradley or third-party DeviceNet system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Multi-Node Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports up to 64 nodes on a single segment and can actively scan up to 40 slave devices. This makes it an ideal choice for complex assembly lines or material handling systems requiring high-density peripheral control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuto-Baud and Configurable Rates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting 125, 250, and 500 Kbaud, the module adapts to various network lengths and speed requirements. This flexibility ensures reliable data transmission over long distances or high-speed performance for time-critical motion tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 512-byte I\/O data exchange capacity (up to 125 bytes per individual I\/O transfer), the module handles large packets of diagnostic and control data without bottlenecking the PLC scan cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200BEM103 plugs into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS006\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecarrier, which provides the standard 5-pin open-style connector required for DeviceNet cabling. This modular design allows for rapid hardware swaps without disturbing the network trunk line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich I\/O carrier is required for the IC200BEM103?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS006\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunications Carrier. Standard I\/O carriers are not compatible with the pinout and mechanical requirements of this network interface module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module operate as a PROFIBUS slave?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While some VersaMax modules share a similar form factor, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200BEM103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis dedicated strictly to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeviceNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol. For PROFIBUS-DP Slave functionality, you would typically require the IC200BEM003.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external power for the network side?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. DeviceNet networks require an external 24VDC power supply to power the transceiver circuitry on the network cable. The module draws its logic power (140mA) from the PLC backplane, but the DeviceNet bus itself must be powered separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the MAC ID (Node Address)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Node Address (0–63) and Baud Rate are typically configured via software (such as Proficy Machine Edition) or through hardware switches on the carrier, depending on the revision and configuration mode selected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217828118618,"sku":"IC200BEM103","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/8.1_19ee875a-5237-4134-acae-2e60f1d85d28.jpg?v=1776219197"},{"product_id":"ic200pwr002-ge-fanuc-versamax-24vdc-power-supply-new","title":"IC200PWR002 GE Fanuc VersaMax 24VDC Power Supply New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200PWR002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a vital supplemental power source for the GE VersaMax PLC and I\/O system. It converts a nominal 24VDC input into regulated 5VDC and 3.3VDC power to drive the backplane bus. This module proves essential when the total current draw of the CPUs, Network Interface Units (NIUs), and I\/O modules exceeds the capacity of the primary power supply. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring stable voltage regulation and electrical protection for your high-density automation racks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal (Range: 18–30 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC and 3.3 VDC Regulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 Amperes (Maximum combined)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3.3VDC Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 A Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5VDC Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 A (minus 3.3V current used)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHoldup Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20A @ 24VDC \/ 25A @ 30VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort Circuit, Overload, and Reverse Polarity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Rack Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200PWR002 allows you to expand your VersaMax station beyond the limits of a single power supply. By injecting additional current into the backplane, it supports high-density analog modules and communication interfaces that demand higher power consumption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Voltage Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module simultaneously regulates both 5VDC and 3.3VDC lines. This dual-output capability ensures that newer, low-voltage internal circuitry and standard logic components receive stable, ripple-free power within a single module footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Electrical Safeguards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated circuitry actively protects the system against short circuits, overloads, and reverse polarity wiring errors. These safeguards prevent localized faults from damaging expensive CPU or I\/O hardware across the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Booster Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installed on a Booster Carrier, the IC200PWR002 works in tandem with the primary power supply to distribute load effectively. This configuration maintains system uptime even when the I\/O count increases during facility upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Thermal Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a low-heat dissipation design, requiring only 11W of input power. Its compact size fits easily into standard VersaMax carriers, maximizing DIN rail space in cramped control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhen do I need to add an IC200PWR002 to my VersaMax system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must add this supplemental power supply if your total module current calculation exceeds the 5VDC or 3.3VDC rating of your main Power Supply or NIU. High-density analog or specialized communication modules often necessitate the use of an IC200PWR002.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200PWR002 be used as the primary power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTypically, this module acts as a supplemental supply used on a Booster Carrier. It complements the main supply to provide additional current to modules further down the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide isolation between the 24VDC input and the backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200PWR002 is a non-isolated power supply. If your application requires high-voltage isolation between the field power and the PLC logic, ensure your primary power supply or external 24VDC source provides the necessary galvanic isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I exceed the 1.5A total current limit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated overload protection will trigger, dropping the output voltage to protect the internal components. You should recalculate your power requirements and potentially add another supplemental supply if this occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217832902746,"sku":"IC200PWR00","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/9._1dc75f08-85b8-4770-b588-59929fca64ca.jpg?v=1776219452"},{"product_id":"buy-new-ge-ic200mdl143-versamax-120v-ac-input-module","title":"Buy New GE IC200MDL143 VersaMax 120V AC Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL143\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-voltage discrete sensing for the VersaMax PLC platform. This module interfaces directly with 120VAC field devices, converting high-voltage signals into logic-level data for the CPU. Each of the eight channels features full isolation, allowing the module to monitor signals from different power sources or phases within a single unit. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging, guaranteeing maximum signal integrity for your distributed I\/O and control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mA (at 5V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (On)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Cycle (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (Off)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Cycles (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and Channel-to-backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Individually Numbered LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 mm x 66.8 mm x 50.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFits VersaMax I\/O Carriers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase-Independent Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200MDL143 isolates every channel from the others. This allows you to monitor eight different 120VAC circuits even if they originate from different phases or completely separate power grids, eliminating the need for interposing isolation relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Signal Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module directly accepts 120VAC signals, removing the cost and cabinet space required for AC-to-DC signal converters. It effectively bridges the gap between high-voltage field equipment (pushbuttons, limit switches, and motor starters) and the low-voltage PLC backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe optical isolation barrier prevents high-voltage transients and electrical noise on the field side from reaching the sensitive PLC backplane logic. This architecture ensures the CPU remains stable even in environments with heavy electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEight numbered LEDs provide real-time status for each input point. These indicators allow maintenance teams to verify field-side activity at a glance, significantly reducing downtime during signal tracing and system commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite handling high-voltage inputs, the module maintains the standard VersaMax compact form factor. It snaps into any standard VersaMax I\/O carrier, allowing for a mix of AC and DC modules in the same rack to optimize panel space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200MDL143 detect DC signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module is specifically engineered for 120VAC operation. To monitor 24VDC or 125VDC signals, you must select the appropriate DC input module (e.g., IC200MDL240 or IC200MDL140) to ensure accurate signal detection and hardware longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 1-cycle response time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"On\" response time of 1 cycle (approx. 16.6ms at 60Hz) includes the time required for the internal filter to debounce the AC signal. This prevents false triggers caused by contact bounce or momentary voltage spikes on the AC line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws its logic power (50mA) directly from the VersaMax backplane. However, the field-side devices (switches, sensors) must be powered by an external 120VAC source to provide the necessary input signal to the module terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the IC200MDL143 a relay output or a discrete input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200MDL143 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDiscrete Input Module\u003c\/strong\u003e. While some VersaMax modules share similar numbering, this specific part number is designed to \"read\" 120VAC signals. If you require relay \"outputs\" to control loads, please refer to the IC200MDL940.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217863180378,"sku":"IC200MDL143","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/500.1_1fe7b4c9-bfc0-4c03-b8c5-07c325de86c0.jpg?v=1776219768"},{"product_id":"plc-i-o-expansion-24vdc-transistor-module-ic200uex122","title":"PLC I\/O Expansion 24VDC Transistor Module | IC200UEX122","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UEX122\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density discrete expansion module for the VersaMax Micro PLC series. It provides an additional 28 I\/O points—comprised of 16 digital inputs and 12 transistor outputs—to extend the control reach of a base CPU unit. Operating on a standard 24 VDC power supply, this module integrates seamlessly into compact automation architectures where cabinet space remains limited. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring factory-level performance and long-term field stability for your OEM machinery or factory process lines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicro PLC Expansion Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Inputs (24 VDC, Sink\/Source Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Outputs (24 VDC Transistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 mA per input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed execution for real-time control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro PLC Base Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Scaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200UEX122 adds significant I\/O capacity without requiring a migration to a larger PLC platform. This compact design allows engineers to scale control systems for complex machinery while maintaining a small enclosure footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Logic Input Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 digital inputs support both positive (Source) and negative (Sink) logic. This versatility allows the module to interface with a diverse array of field sensors, including NPN or PNP proximity switches and limit switches, without requiring interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Solid-State Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 12 transistor outputs provide fast, bounce-free switching. Unlike mechanical relays, these solid-state outputs offer virtually unlimited switching cycles, making them ideal for high-frequency applications like solenoid valve control or rapid status indication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for 24VDC Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module operates entirely on 24 VDC, matching standard industrial power distribution. This simplifies the wiring architecture and ensures compatibility with most modern sensors and actuators used in factory automation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe expansion unit connects directly to the VersaMax Micro base controller via the built-in expansion port. This modular approach supports rapid assembly and simplifies maintenance, as users can replace or add modules without redesigning the entire system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200UEX122 operate as a standalone PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200UEX122 is an expansion unit, not a standalone controller. It requires a connection to a VersaMax Micro PLC base unit (which contains the CPU) to function and execute logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of wiring is required for the transistor outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transistor outputs can be wired for either sink or source configurations depending on your specific load and power supply wiring. Always refer to the wiring diagram to ensure the common terminals match your field device requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many expansion units can I add to a single Micro PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe total number of expansion modules depends on the specific VersaMax Micro base model you are using. Most Micro controllers support up to 4 expansion units, but you must verify the total power consumption does not exceed the base unit's capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs external protection necessary for the outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module is robust, we strongly recommend external fusing for all transistor outputs. This protects the internal solid-state components from irreversible damage caused by short circuits or accidental overcurrent in the field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217909186650,"sku":"IC200UEX122","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/10._6af292f0-c8ce-49c6-affd-ac311a2d82be.jpg?v=1776220172"},{"product_id":"versamax-micro-14-point-plc-new-ic200udd104-ge-fanuc","title":"VersaMax Micro 14-Point PLC New | IC200UDD104 GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UDD104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a highly efficient, entry-level controller within the VersaMax Micro PLC family. This 14-point all-in-one unit integrates a CPU, power supply, and digital I\/O into a single housing. It provides 8 digital inputs and 6 transistor outputs, specifically engineered for small-scale industrial applications and OEM machinery. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automation system benefits from factory-spec reliability and precise real-time logic execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Inputs (24 VDC, Sink\/Source Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Outputs (24 VDC Transistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 1.0A \/ 4 x 0.5A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ-45 Serial Port (RS-232)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExpansion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 4 Expansion Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Physical I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e126 Points (via expansion)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200UDD104 features a tiered output current design. Two of the six transistor outputs handle higher loads (1.0 Amp), while the remaining four handle standard 0.5 Amp loads. This allows the PLC to drive larger solenoids or contactors directly without requiring external interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Input Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8 digital inputs accommodate both positive and negative logic. This flexibility ensures the controller interfaces seamlessly with a variety of field sensors, including NPN or PNP proximity switches, reducing your hardware overhead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Logic Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated CPU delivers fast cycle times suitable for high-speed OEM machinery. It executes complex control algorithms and monitors high-frequency signals with minimal propagation delay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its compact \"Micro\" footprint, the IC200UDD104 connects to up to four expansion modules. This allows the system to grow from a simple 14-point controller to a comprehensive station managing up to 126 I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit fits easily into shallow control cabinets. The integrated design eliminates the need for a separate rack or power supply module, significantly reducing the overall footprint of your electrical enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the output ratings on the IC200UDD104?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module differentiates its 6 outputs to provide application flexibility: 2 outputs support up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.0 Amp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor driving heavier inductive loads, while 4 outputs support up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 Amp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor standard logic signaling and small indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I program this unit with modern GE\/Emerson software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200UDD104 supports programming via Proficy Machine Edition (PME). It utilizes the standard RJ-45 serial port (RS-232) for logic uploads and online diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200UDD104 operates on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efield power. You must provide a stable 24VDC source to the power terminals to run the internal CPU and energize the transistor output circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I protect the transistor outputs from short circuits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause transistor outputs are sensitive to overcurrent, we recommend installing external fast-acting fuses. For inductive loads (like solenoids), always install suppression diodes (flyback diodes) to prevent back-EMF spikes from damaging the internal solid-state components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217992745050,"sku":"IC200UDD104","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/11._516f31da-f437-4aad-9fb7-e6e0d34c6a64.jpg?v=1776220478"},{"product_id":"32-point-spring-terminal-block-new-ge-ic200chs005","title":"32-Point Spring Terminal Block New | GE IC200CHS005","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the fundamental mounting and wiring base for the VersaMax I\/O system. This local, spring-style carrier provides the mechanical housing and electrical interface for a single VersaMax I\/O module. Utilizing spring-clamp technology, it ensures gas-tight, vibration-resistant connections for field wiring without the need for periodic torque checks. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing a high-integrity connection point for your mission-critical automation hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpring-Style Terminal I\/O Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Terminals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 Spring-Clamp Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Points Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 32 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Amps per Point (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e264 Volts AC (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommon\/Power Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Integrated Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.37 to 0.45 lb-ft (For internal mounting screws)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.88 lbs (0.40 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Proof Spring Clamps:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CHS005 utilizes spring-clamp terminals instead of traditional screws. This design maintains constant pressure on the wire, preventing signal loss or intermittent connections in high-vibration environments typical of heavy machinery or transport applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Wiring Deployment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe spring-style mechanism significantly reduces installation time. Technicians insert wires directly into the clamp, eliminating the labor-intensive process of tightening 36 individual screws and ensuring a uniform connection across all points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density I\/O Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier supports up to 32 I\/O points and includes four additional terminals for power and common distributions. This high-density layout minimizes the number of terminal blocks required in the control cabinet, saving valuable DIN rail space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Hot-Swap Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier separates the field wiring from the active electronic module. This architecture allows maintenance personnel to \"hot-swap\" the I\/O module while leaving the field wiring intact, drastically reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Mounting Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile optimized for horizontal DIN rail mounting, the carrier also supports direct panel mounting. Its integrated design allows multiple carriers to snap together, forming a continuous internal backplane for power and communication between modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the IC200CHS005 and the IC200CHS002?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200CHS005 features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espring-clamp terminals\u003c\/strong\u003e, which provide faster wiring and better vibration resistance. The IC200CHS002 uses traditional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebarrier-style screw terminals\u003c\/strong\u003e. Both are functionally interchangeable regarding module compatibility but differ in wiring methodology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need special tools to wire the IC200CHS005?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou only need a small flat-head screwdriver to depress the spring-clamp tab. Once depressed, you insert the stripped wire, and the clamp secures it automatically upon release of the tab.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this carrier for Analog modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200CHS005 supports the full range of VersaMax discrete and analog modules. However, for highly sensitive analog signals, ensure you follow GE Fanuc’s specific grounding and shielding guidelines for the carrier's frame ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the IC200CHS005 compatible with all VersaMax CPUs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis carrier is for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O modules\u003c\/strong\u003e. While it connects to the same backplane system as the CPU, CPUs typically use their own specific power supply or base carriers. Use this module to house your digital\/analog inputs and outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218042093658,"sku":"IC200CHS005","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/12._27abc7c9-83fc-489d-89f5-abc607e2e9e9.jpg?v=1776220820"},{"product_id":"buy-new-ge-ic200cpls001-plc-diagnostic-interface","title":"Buy New GE IC200CPLS001 PLC Diagnostic Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CPLS001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a dedicated diagnostic gateway for the VersaMax PLC platform. This module provides critical real-time visibility into the health of the entire control system, including power supply status, CPU operational integrity, and I\/O bus health. By consolidating system-wide diagnostics into a high-visibility LED interface, it allows maintenance personnel to identify faults instantly without connecting a laptop. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automation rack features factory-certified monitoring and maximum system uptime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Status \/ Diagnostic Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Intensity LED Array (Power, CPU, I\/O, Fault)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDraws power from the VersaMax Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard VersaMax I\/O Carrier (DIN Rail or Panel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVisual health monitoring and fault localization\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAll VersaMax CPU and NIU configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLightweight, compact design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade polycarbonate housing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstantaneous Fault Localization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CPLS001 eliminates the \"guesswork\" during system downtime. Dedicated LED indicators track specific failure points, such as backplane power drops or I\/O communication errors, enabling operators to pinpoint the root cause in seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Intrusive Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module draws minimal current from the backplane and monitors system health without interrupting the CPU scan cycle. It provides a constant heartbeat of the automation environment while remaining transparent to the control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Backplane Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps into any standard VersaMax I\/O carrier. This modularity allows you to place the diagnostic interface at the most visible point in the cabinet, ensuring that status indicators remain accessible to field technicians.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReduction in Mean Time to Repair (MTTR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy providing visual confirmation of CPU and I\/O health, the IC200CPLS001 reduces the need for specialized diagnostic tools during first-line troubleshooting. It empowers on-site maintenance staff to perform rapid system resets or module swaps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Industrial Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for harsh factory floors, the IC200CPLS001 withstands the vibration and thermal fluctuations common in OEM machinery. Its solid-state LED design ensures a long operational life compared to traditional mechanical indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC200CPLS001 require any software configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200CPLS001 is a hardware-driven diagnostic tool. Once you install it into a powered VersaMax carrier, it automatically begins monitoring the backplane signals and reflecting the system status via its onboard LEDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module execute control logic or handle I\/O signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200CPLS001 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediagnostic-only\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule. It does not possess an onboard processor for user logic, nor does it provide digital or analog I\/O points. Use it strictly for system monitoring and health feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the best place to install this module in my rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo maximize its effectiveness, install the IC200CPLS001 in the first few slots adjacent to the CPU or Network Interface Unit (NIU). This positioning ensures the LEDs are easily visible as soon as the cabinet door opens.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with the VersaMax Micro or Nano series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200CPLS001 is designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodular VersaMax\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem (using I\/O carriers). While it shares the VersaMax brand name, it is not compatible with the fixed-I\/O VersaMax Micro or Nano controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218093211738,"sku":"IC200CPLS001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/13._dfee10e2-a7f3-4695-971b-2b893674954e.jpg?v=1776221182"},{"product_id":"ic200acc403-battery-for-23-and-28-point-versamax-micro","title":"IC200ACC403 Battery for 23 and 28 Point VersaMax Micro","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC403\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides essential memory backup for GE VersaMax Micro PLC systems, specifically targeting the 23-point and 28-point controllers. This 3.0V Lithium coil cell assembly features pre-installed wire leads and a specialized connector to ensure a secure interface with the PLC’s internal battery holder. It maintains critical RAM data and real-time clock (RTC) settings during power interruptions. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automation logic remains intact during scheduled maintenance or unexpected power loss.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChemistry\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium (Non-Rechargeable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e210 mAh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoil Cell with Wire Leads and Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShelf Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 5 years at 30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eService Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 months minimum backup at 55°C (Power Off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReporting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMonitored via Status Bits %SA011 and %SA014\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Micro 23 and 28 Point Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGuaranteed Data Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ACC403 preserves the user program, register data, and internal state variables. This eliminates the need for manual program reloads and minimizes downtime following a facility power cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Status Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VersaMax CPU actively monitors the battery health. It reports low-voltage conditions directly to the PLC fault table and triggers internal status bits (%SA011\/%SA014). This allow engineers to program HMI alarms for proactive battery replacement before data loss occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for High-Temperature Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard consumer batteries, this industrial-grade lithium cell maintains a reliable discharge curve even in hot control cabinets. It provides a minimum of 4 months of continuous backup at 55°C, ensuring protection during long-term machine storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated wire leads and connector allow for rapid replacement without specialized soldering tools. The design ensures the correct polarity, preventing potential circuit damage during field installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Storage Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a shelf life of up to 5 years, the IC200ACC403 serves as an ideal spare part to keep in inventory. The low self-discharge rate guarantees that the battery remains ready for deployment whenever the system requires a fresh cell.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a standard CR2032 from a retail store instead of the IC200ACC403?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the cell itself is a 3V lithium type, the IC200ACC403 includes the specific wire leads and connector required by the VersaMax Micro housing. Standard batteries lack these leads and will not interface with the PLC's internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the IC200ACC403?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGE Fanuc recommends monitoring the CPU status bits. However, as a best practice, most maintenance teams replace the battery every 2 to 3 years to ensure the 4-month backup window remains valid, especially in environments with frequent power-down cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the PLC lose its program immediately when I unplug the old battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PLC typically uses an onboard capacitor to maintain memory for a very short duration (seconds to minutes) while you swap the battery. To prevent data loss, always perform the battery replacement while the PLC remains powered on, following all electrical safety protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the battery fails and I don't replace it?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the battery voltage drops below the threshold and the PLC loses main power, the volatile RAM will clear. This results in the loss of all user-defined variables and the application program unless it was previously saved to non-volatile flash memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218155896922,"sku":"IC200ACC403","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/14._a6b0c2b1-de4b-443b-8534-3da343f4c40f.jpg?v=1776221499"},{"product_id":"plc-analog-i-o-module-original-stock-ic200alg432","title":"PLC Analog I\/O Module Original Stock | IC200ALG432","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG432\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a versatile, cost-effective solution for applications requiring both analog input and output capabilities in a single slot. This VersaMax mixed module features 4 analog input channels and 2 analog output channels, primarily supporting ±10VDC voltage signals. By consolidating mixed I\/O into one unit, it significantly reduces hardware costs and backplane footprint. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-precision signal processing for your OEM machinery and distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Mixed Module (Input\/Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Total Points (4 Inputs \/ 2 Outputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 VDC (Input and Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-Bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (25°C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.3% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 mA @ 5V DC (from backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-Backplane Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 lbs (0.17 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Mixed I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ALG432 eliminates the need for separate input and output modules in small-scale applications. This integration saves valuable DIN rail space and reduces the number of I\/O carriers required in the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn update rate of 0.4ms ensures the PLC receives and transmits analog data with minimal latency. This speed allows for high-performance closed-loop control of fast-acting proportional valves and variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecise 12-Bit Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 12-bit conversion delivers the granularity needed for accurate process monitoring and control. It translates ±10V signals into precise digital increments, ensuring the CPU detects subtle changes in pressure, flow, or temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust channel-to-backplane isolation protects the PLC’s sensitive logic circuitry from electrical noise and ground loops common in industrial environments. This shielding ensures signal stability even when the module shares a rack with high-voltage discrete I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLike all VersaMax components, the IC200ALG432 snaps into a standard I\/O carrier. This modular design permits \"hot-swapping\" (in supported configurations), allowing maintenance teams to replace hardware without disturbing field wiring, thereby reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure the IC200ALG432 for 4-20mA current signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200ALG432 is primarily designed for ±10VDC voltage signals. While some mixed modules support multiple ranges, always check your specific hardware revision. If your sensors utilize 4-20mA, you may require external precision resistors or a dedicated current module like the IC200ALG430.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws its 5VDC logic power (160mA) from the VersaMax backplane. However, the analog field devices (actuators or sensors) usually require their own 24VDC external power source to drive the signal loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the IC200ALG432 compatible with all VersaMax CPUs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it integrates with all VersaMax modular CPUs and Network Interface Units (NIUs). It requires a standard VersaMax I\/O carrier (such as IC200CHS001 or IC200CHS002) for proper installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does temperature affect the module's accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module maintains high accuracy (±0.3% of full scale) at 25°C. In extreme industrial conditions up to 60°C, the accuracy rating shifts to a maximum of ±1%, which remains within the acceptable range for most factory automation tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218206949466,"sku":"IC200ALG432","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/15._7820389a-9080-4cfb-a7e8-6f35474e5c50.jpg?v=1776222318"},{"product_id":"buy-new-ge-ic200cpu005-versamax-modular-plc-cpu","title":"Buy New GE IC200CPU005 VersaMax Modular PLC CPU","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CPU005\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary processing engine for the VersaMax modular PLC family. This high-performance CPU module executes complex logic at high speeds, offering 64KB of configurable user memory for programs and data registers. It supports advanced mathematical functions, including floating-point math, making it suitable for sophisticated process control and OEM machinery. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automation architecture runs on factory-certified hardware with peak execution efficiency.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 KB (Configurable for Program\/Data)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoolean Execution Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 ms\/K (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFloating Point Math\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (Built-in Support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 256 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExpanded I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 4096 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete I\/O Max\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2048 Inputs \/ 2048 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBuilt-in Comms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x RS-232 Port and 1x RS-485 Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReal-Time Clock Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 ppm (±9 sec\/day)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC via VersaMax Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstruction Set\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLadder Logic, Function Block, C Programming\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Processing Speed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CPU005 delivers a Boolean execution speed of 0.8 ms\/K. This rapid scan time ensures the PLC handles high-speed machine transitions and real-time process adjustments without lag, enhancing overall equipment effectiveness (OEE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Memory Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers can configure the 64KB memory pool to prioritize either large application programs or extensive data logging. This adaptability allows the CPU to manage data-heavy registers (%R) for process trending while maintaining complex ladder logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Dual Protocol Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module integrates both RS-232 and RS-485 serial ports directly into the front panel. This dual-port design allows for simultaneous HMI interfacing and multi-drop networking to peripheral devices like drives or other PLCs without requiring additional communication cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile maintaining a compact \"Micro\" form factor, this CPU controls up to 4096 I\/O points when utilizing expansion racks. It bridges the gap between small standalone controllers and large-scale plant automation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFloating Point Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in support for floating-point math enables the IC200CPU005 to perform precise calculations for PID loops, flow totalization, and motion scaling. This eliminates the need for complex integer-to-float conversion logic, simplifying program development.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the RS-232 and RS-485 ports on the IC200CPU005?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe RS-232 port typically utilizes an RJ-45 connector for programming and HMI connection. The RS-485 port facilitates SNP or Modbus RTU communications for multi-drop networks. You define these settings within the Proficy Machine Edition (PME) software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I upgrade from an older IC200CPU001 to this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200CPU005 provides significantly more memory and faster execution speeds than the CPU001. Because they share the same VersaMax carrier architecture, you can swap the hardware and download the existing program with minimal configuration changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this CPU require a separate battery for memory retention?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200CPU005 relies on a backup battery (typically IC200ACC403) to preserve the RAM-based user program and data registers during power-off periods. Always verify battery health via the CPU status LEDs or software fault tables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting carrier does this CPU require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPU must snap into a VersaMax CPU\/Power Supply carrier (such as the IC200CHS002). This carrier provides the necessary backplane connections to I\/O modules and the interface for the 24VDC or 120\/240VAC power supply module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218244304986,"sku":"IC200CPU005","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/16._81c9a9c5-3f56-4dee-9906-725fa5e57beb.jpg?v=1776222565"},{"product_id":"ic200dbi001-devicenet-scanner-compatibility-128-byte-i-o-new","title":"IC200DBI001 DeviceNet Scanner Compatibility 128 Byte I\/O New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200DBI001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance DeviceNet Slave Network Interface Unit (NIU) for the VersaMax I\/O family. This module enables the integration of VersaMax I\/O modules into a DeviceNet network, allowing a master controller to manage distributed inputs and outputs across the factory floor. It acts as the \"head\" of a remote I\/O station, managing communication for up to 8 local I\/O modules. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring seamless connectivity and industrial-grade reliability for your distributed control architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDevice Role\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSlave (Polling Communication)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 Bytes Input \/ 128 Bytes Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 8 modules per station\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 kbps, 250 kbps, 500 kbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 64 Nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Pin Open Style (Standard DeviceNet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePWR, OK, FAULT, MOD, NET, FORCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, cULus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.69 lbs (0.31 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200DBI001 allows you to place I\/O points closer to the actual field sensors and actuators. This distributed approach eliminates massive wiring bundles back to a central PLC, significantly reducing installation labor and material costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Data Rate Negotiation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports standard DeviceNet speeds of 125, 250, and 500 kbps. This flexibility ensures compatibility with existing network trunk line lengths and meets varying response time requirements for real-time control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Visual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSix front-panel LED indicators provide immediate feedback on network and module health. These indicators (MOD, NET, FAULT, etc.) allow technicians to distinguish between local hardware failures and network-wide communication issues without connecting specialized software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Efficiency Data Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a capacity for 128 bytes of input and output data, a single IC200DBI001 station accommodates high-density digital and analog module combinations. This makes it an ideal choice for complex OEM machinery requiring diverse signal types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module integrates into standard VersaMax carriers. This modularity allows for the rapid replacement of the NIU without disturbing field wiring on the attached I\/O modules, keeping Mean Time to Repair (MTTR) to an absolute minimum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200DBI001 function as a DeviceNet Master?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200DBI001 operates strictly as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSlave\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edevice. It requires a DeviceNet Master (Scanner), such as an IC200BEM103 or a third-party controller, to initiate communications and manage the network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many I\/O modules can I attach to a single IC200DBI001?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can install up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 VersaMax I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the same station as the IC200DBI001. Ensure your total data count does not exceed the 128-byte input\/output limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external power for DeviceNet communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module logic is powered via the VersaMax backplane, the DeviceNet network itself requires a separate 24VDC power source on the 5-pin connector (V+ and V-) to power the transceiver circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the MAC ID and Baud Rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou typically configure the Node Address (MAC ID) and Baud Rate using DIP switches located on the module or through software configuration tools, depending on the hardware revision. Always ensure the Baud Rate matches the rest of the DeviceNet network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218255839322,"sku":"IC200DBI001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/17._e457632e-afc6-4db9-b20d-8215632720a6.jpg?v=1776222916"},{"product_id":"80khz-high-speed-counter-i-o-original-emerson-ic200mdd841","title":"80KHz High-Speed Counter I\/O Original | Emerson IC200MDD841","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDD841\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized, high-density solution for applications requiring both standard discrete control and precision pulse sensing. This VersaMax module integrates 32 total I\/O points, featuring 20 digital inputs and 12 digital outputs. Most importantly, it includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour Type A High-Speed Counters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapable of processing pulse signals up to 80 KHz. This makes it a critical component for motion tracking, flow metering, and high-speed sorting. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-frequency accuracy for your most demanding industrial tasks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Points (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Points (24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Points (24 VDC Transistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHigh-Speed Counter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Type A Counters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Pulse Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 KHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC (Draws from carrier)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 lbs (0.17 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision High-Speed Sensing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe four onboard 80 KHz high-speed counters allow the PLC to track rapid mechanical movements that standard input modules would miss. This capability supports precise encoder feedback, turbine flow meter monitoring, and high-velocity pulse-width modulation (PWM) tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized I\/O Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy combining 20 inputs and 12 outputs into a single module width, the IC200MDD841 reduces hardware overhead. This high-density footprint saves significant space on the DIN rail and simplifies cabinet layout for complex OEM machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Transistor Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 12 transistor outputs provide the rapid, bounce-free switching necessary for controlling high-cycle solenoids or triggering external motion drives. Unlike mechanical relays, these solid-state outputs support high-frequency operation with virtually infinite mechanical life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Signal Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 24 VDC inputs interface easily with standard industrial sensors. The module processes pulse trains and standard discrete signals simultaneously, allowing it to handle basic interlocking logic and advanced motion counting within the same hardware block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LEDs provide immediate visual feedback for each I\/O point and the overall health of the high-speed counter channels. This transparency streamlines commissioning and reduces troubleshooting time during field maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between Type A counters and standard inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard inputs are limited by the PLC scan cycle (typically 1–10ms). The Type A High-Speed Counters on the IC200MDD841 operate independently of the CPU scan, allowing them to capture pulses up to 80,000 times per second (80 KHz) for total accuracy in high-speed motion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific I\/O carrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the IC200MDD841 requires a standard VersaMax I\/O carrier (such as the IC200CHS001 or IC200CHS002). The carrier provides the physical wiring terminals and the backplane connection to the PLC CPU or Network Interface Unit (NIU).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the outputs for Pulse Width Modulation (PWM)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The transistor outputs on this module are suitable for high-speed switching tasks, including PWM and pulse-train generation (PTO) for driving stepper or servo controllers, provided the frequency requirements fall within the module's rated switching limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 24VDC power isolated from the backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features optical isolation between the field-side 24VDC signals and the 5VDC backplane logic. This protects the PLC CPU from electrical surges, transients, and ground loops occurring in the field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218260754522,"sku":"IC200MDD841","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/18._b075e68a-1908-486b-8414-a7788bbfad4b.jpg?v=1776223230"},{"product_id":"ic200mdl940-plc-relay-module-16-point-normally-open","title":"IC200MDL940 PLC Relay Module 16-Point Normally Open","description":"\u003ch3 data-path-to-node=\"8\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-path-to-node=\"9\" data-index-in-node=\"4\"\u003eIC200MDL940\u003c\/b\u003e provides high-capacity, isolated switching for the VersaMax PLC platform. This module features 16 independent \"Form A\" (Normally Open) relay outputs, allowing the control of various loads across diverse voltage ranges. Each channel operates with full isolation, enabling the module to manage a mix of AC and DC circuits within a single unit. We supply this product as \u003cb data-path-to-node=\"9\" data-index-in-node=\"384\"\u003e100% Brand New and Original\u003c\/b\u003e, ensuring peak contact integrity and long-term switching reliability for your critical automation infrastructure.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"11\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,0,0\"\u003e\u003cb data-path-to-node=\"11,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,1,1,0\"\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,0,0\"\u003e\u003cb data-path-to-node=\"11,2,0,0\" data-index-in-node=\"0\"\u003eProduct Line\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,2,1,0\"\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,0,0\"\u003e\u003cb data-path-to-node=\"11,3,0,0\" data-index-in-node=\"0\"\u003eOutput Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,3,1,0\"\u003eMechanical Relay, Form A (Normally Open)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,0,0\"\u003e\u003cb data-path-to-node=\"11,4,0,0\" data-index-in-node=\"0\"\u003eNumber of Points\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,4,1,0\"\u003e16 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,0,0\"\u003e\u003cb data-path-to-node=\"11,5,0,0\" data-index-in-node=\"0\"\u003eAC Load Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,5,1,0\"\u003e0 to 265 VAC (120\/240 VAC Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,6,0,0\"\u003e\u003cb data-path-to-node=\"11,6,0,0\" data-index-in-node=\"0\"\u003eDC Load Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,6,1,0\"\u003e0 to 125 VDC (5\/24\/125 VDC Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,7,0,0\"\u003e\u003cb data-path-to-node=\"11,7,0,0\" data-index-in-node=\"0\"\u003eLoad Current (AC\/DC)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,7,1,0\"\u003e2.0 A max per point (Resistive, up to 30VDC\/265VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,8,0,0\"\u003e\u003cb data-path-to-node=\"11,8,0,0\" data-index-in-node=\"0\"\u003eResponse Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,8,1,0\"\u003e10 ms (On) \/ 10 ms (Off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,9,0,0\"\u003e\u003cb data-path-to-node=\"11,9,0,0\" data-index-in-node=\"0\"\u003eIsolation\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,9,1,0\"\u003e1500 VAC (Input to Frame) \/ 250 VAC (Channel to Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,10,0,0\"\u003e\u003cb data-path-to-node=\"11,10,0,0\" data-index-in-node=\"0\"\u003eBackplane Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,10,1,0\"\u003e490 mA (Maximum at 5V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,11,0,0\"\u003e\u003cb data-path-to-node=\"11,11,0,0\" data-index-in-node=\"0\"\u003eContact Material\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,11,1,0\"\u003eSilver Alloy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,12,0,0\"\u003e\u003cb data-path-to-node=\"11,12,0,0\" data-index-in-node=\"0\"\u003eStatus Indicators\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"11,12,1,0\"\u003eIndividual Logic LEDs, FLD PWR LED, OK LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eComplete Point-to-Point Isolation:\u003c\/b\u003e The IC200MDL940 isolates every output point from all others. This architecture eliminates the need for external isolation barriers and allows the module to switch different phases of AC or different DC voltage sources (e.g., 24VDC and 240VAC) simultaneously without risk of cross-talk or ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eMixed Load Versatility:\u003c\/b\u003e The silver alloy contacts handle a wide range of current levels, from a 10mA minimum up to a 2.0A maximum. This flexibility enables the controller to drive small indicator lamps and heavy-duty motor contactors or solenoids through the same module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eHigh-Voltage DC Switching:\u003c\/b\u003e Unlike standard transistor modules, the IC200MDL940 manages DC voltages up to 125VDC. This capability proves essential for legacy utility systems and specialized DC control circuits where high-voltage switching is mandatory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eComprehensive Visual Diagnostics:\u003c\/b\u003e Three levels of LED indication streamline troubleshooting. The logic-side LEDs verify command signals from the CPU, the \u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"154\"\u003eFLD PWR\u003c\/b\u003e LED confirms the presence of field power, and the \u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"212\"\u003eOK\u003c\/b\u003e LED validates backplane health, ensuring rapid fault identification during system downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-path-to-node=\"13,4,0\" data-index-in-node=\"0\"\u003eRobust Mechanical Design:\u003c\/b\u003e The fixed-coil, moving-armature relay design withstands the rigors of industrial environments. Rated for temperatures up to 60°C and offering 1500VAC isolation to frame ground, this module protects the sensitive PLC backplane from field-side transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eFAQs\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eCan I mix AC and DC loads on the same IC200MDL940 module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003eYes. Because every point is individually isolated, you can connect different voltages and power types (AC or DC) to adjacent terminals without interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eDoes this module require an external power supply?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003eThe module logic runs on 5VDC from the backplane (490mA draw). However, you must provide the appropriate field power to the relay contacts to drive your connected loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eWhat is the maximum switching frequency for these relays?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003eThe module supports a maximum switching frequency of 20 cycles per minute. For high-speed switching applications, we recommend using transistor output modules (e.g., IC200MDL740) to avoid mechanical wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eIs there a minimum load requirement for the contacts?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003eYes, each point requires a minimum load current of 10mA. This ensures the silver alloy contacts \"wipe\" properly, maintaining low contact resistance over the life of the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218262032474,"sku":"IC200MDL940","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/19._f75ec0d6-b3f3-4e5c-aeed-d91b140bb465.jpg?v=1776223535"},{"product_id":"ge-ic200pbi001-profibus-network-interface-12mbps-original","title":"GE IC200PBI001 PROFIBUS Network Interface 12Mbps Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200PBI001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-speed communication gateway for the VersaMax I\/O station within a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-DP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetwork. This Network Interface Unit (NIU) enables a PROFIBUS Master to control remote VersaMax I\/O modules as a distributed slave station. It handles all data exchange between the PROFIBUS bus and the local I\/O modules, supporting up to 375 bytes of total data. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original in Factory Packing\u003c\/strong\u003e, ensuring immediate integration and long-term network stability for your automation architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS-DP (IEC 61158)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 Kbaud to 12 Mbaud (Auto-Detected)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Address\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 125 (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e375 Bytes Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput\/Output Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 244 Bytes Input or 244 Bytes Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 modules per station (Up to 64 total via racks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9-pin D-sub (Female)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLinear bus, terminated at both ends\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Bytes Standard PROFIBUS Diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V @ 250 mA; 3.3V @ 10 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePWR, OK, FAULT, NETWORK, FORCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Determinism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200PBI001 supports the full PROFIBUS-DP speed range up to 12 Mbps. The auto-detection feature ensures the module synchronizes instantly with the master’s baud rate, reducing commissioning time and guaranteeing deterministic data exchange for time-critical processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge-Scale I\/O Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA single NIU station supports up to 8 I\/O modules locally and can expand to manage 64 modules across 8 racks using expansion cables. This scalability allows for high-density I\/O clusters at a single PROFIBUS node, optimizing network address usage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Linear Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for industrial environments, the module utilizes shielded twisted-pair cabling. It supports transmission distances from 100 to 1200 meters (depending on baud rate), allowing you to distribute I\/O across vast factory floor areas without signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Visual Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFive dedicated LEDs provide real-time feedback. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNetwork LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically monitors PROFIBUS communication health, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFault\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLEDs allow technicians to distinguish between internal hardware issues and external network wiring faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Diagnostic Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module transmits 5 bytes of standard PROFIBUS diagnostic data. This feature enables the master controller to monitor the health of individual I\/O modules within the slave station, facilitating proactive maintenance and reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the PROFIBUS address on the IC200PBI001?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou set the station address (1–125) using the hardware rotary switches located on the module or through the PROFIBUS configuration software (GSD file). Ensure the address is unique on the segment to avoid network conflicts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module function as a PROFIBUS Master?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200PBI001 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSlave-only\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edevice. It requires a PROFIBUS Master, such as a PLC with a PROFIBUS Master module or a dedicated PC interface card, to initiate data exchange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 12Mbps speed require specific cabling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To achieve 12 Mbps, you must use PROFIBUS-certified Type A shielded twisted-pair cable and ensure proper active termination at both physical ends of the linear bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support PROFIBUS-DPV1 acyclic communications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200PBI001 primarily supports standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-DP (V0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor cyclic data exchange. For applications requiring DPV1 (acyclic parameters), verify your specific GSD file version and firmware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218263507034,"sku":"IC200PBI001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/20._963f4d5d-58de-4782-b5f9-a9a3c577a1b4.jpg?v=1776223937"},{"product_id":"ic200cmm020-plc-modbus-master-19200-baud-rs-485","title":"IC200CMM020 PLC Modbus Master 19200 Baud RS-485","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eIC200CMM020\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a dedicated Modbus Master interface for the VersaMax I\/O system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module enables a VersaMax station to orchestrate communications across an RS-485 network,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econtrolling up to 247 Modbus RTU slave devices such as drives,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand power meters.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for seamless integration with Genius and PROFINET Network Interface Units (NIUs),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit bridges the gap between decentralized I\/O stations and third-party serial devices.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWe provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e100% Brand New and Original in Factory Packing\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring stable data throughput and industrial-grade reliability for your communication backbone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU Master\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlave Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports 1 to 247 RTU Slaves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1200, 2400, 4800, 9600, 19200 bps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalf Duplex or Full Duplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption (5V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e460 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption (3.3V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNIU Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius NIU and PROFINET Slave NIU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Modules per Station\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Serial Modules per I\/O Station\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 40°C (32 to 104°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, cULus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExpanded Network Reach:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CMM020 transforms a standard I\/O station into a powerful communication hub.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting up to 247 slaves,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit allows engineers to consolidate data from a vast array of Modbus-compliant peripherals into a single VersaMax node.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFlexible Duplex Operations:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports both Half and Full Duplex RS-485 wiring.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis flexibility accommodates various field wiring architectures and legacy device requirements,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring reliable data exchange regardless of the existing cable infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Density Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYou can install up to two IC200CMM020 modules per Genius or PROFINET NIU station.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis dual-module capability effectively doubles your serial communication capacity without requiring additional PLC CPUs or specialized gateways.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNoise-Resistant RS-485 Physical Layer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing the RS-485 standard,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module excels in electrically noisy industrial environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt maintains signal integrity over long distances,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it ideal for distributed systems spanning large factory floors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStreamlined Diagnostics:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LED indicators and backplane status reporting provide immediate feedback on port activity and module health.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThese features accelerate commissioning and reduce troubleshooting time during network maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan the IC200CMM020 operate as a Modbus Slave?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific module is hardware-coded and firmware-optimized to function exclusively as a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eModbus Master\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf your application requires the VersaMax station to respond to an external master,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eyou must utilize a different communication module or the CPU's built-in ports.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable length does the RS-485 interface support?\u003c\/strong\u003e\u003cspan\u003eThe RS-485 standard typically supports distances up to 1200 meters (4000 feet) at lower baud rates.\u003c\/span\u003e\u003cspan\u003e However,\u003c\/span\u003e\u003cspan\u003e factors like cable quality and environmental EMI influence performance.\u003c\/span\u003e\u003cspan\u003e We recommend using high-quality shielded twisted-pair cable for all 19200 bps installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate power supply?\u003c\/strong\u003e\u003cspan\u003eThe IC200CMM020 draws its operating power directly from the VersaMax backplane (460 mA at 5V).\u003c\/span\u003e\u003cspan\u003e You do not need an external power connection for the module itself,\u003c\/span\u003e\u003cspan\u003e though the RS-485 network may require termination resistors at the physical ends of the bus.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with the VersaMax Micro series?\u003c\/strong\u003e\u003cspan\u003eThe IC200CMM020 is a modular component designed for the \u003c\/span\u003e\u003cstrong\u003eModular VersaMax\u003c\/strong\u003e\u003cspan\u003e system using NIUs or CPUs on carriers.\u003c\/span\u003e\u003cspan\u003e It is not compatible with the fixed-I\/O VersaMax Micro or Nano controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218264621146,"sku":"IC200CMM020","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/21._5b1ecf20-9306-4f38-aa30-d3e5adcf2841.jpg?v=1776224291"},{"product_id":"36-terminal-spring-style-i-o-base-original-ge-ic200chs025","title":"36-Terminal Spring-Style I\/O Base Original | GE IC200CHS025","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS025\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density, space-saving mounting base for the VersaMax modular I\/O system. This compact spring-style carrier provides 36 IEC box-style terminals for field wiring while supporting vertical module orientation to minimize the physical footprint on the DIN rail. Its spring-clamp mechanism ensures gas-tight connections that resist loosening over time. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the structural and electrical foundation necessary for high-reliability industrial automation panels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompact Spring-Style I\/O Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 IEC Box-Style Spring Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSingle Wire Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAWG 14 to AWG 22\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDual Wire Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAWG 18\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVertical Spacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 inches (50.8 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHorizontal Spacing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 inch (25.4 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.69 lbs (0.31 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated VersaMax I\/O Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Temperature Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CHS025 operates reliably in environments ranging from -40°C to 60°C. This extended thermal range makes it an ideal choice for remote terminal units (RTUs) and outdoor control cabinets where seasonal temperature fluctuations often cause standard components to fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Space Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike horizontal carriers, this vertical mounting design reduces the horizontal width of the PLC rack. It allows engineers to pack more I\/O modules into narrow enclosures, effectively solving the \"space-constrained\" panel dilemma.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Resistant Spring Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 36 IEC box-style spring terminals eliminate the risk of screw-loosening caused by machine vibration or thermal cycling. This ensures a maintenance-free connection that maintains electrical continuity without the need for periodic re-torqueing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Wiring Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier accommodates a wide range of wire sizes from AWG 14 down to AWG 22. It also supports dual-wire configurations (AWG 18), allowing for simplified daisy-chaining of common power or ground signals directly at the terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Module Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier separates the field wiring from the active electronics. If an I\/O module requires replacement, the wiring remains undisturbed on the IC200CHS025, drastically reducing labor time and eliminating the possibility of wiring errors during service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the IC200CHS025 differ from standard horizontal carriers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200CHS025 utilizes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evertical orientation\u003c\/strong\u003e, which primarily saves horizontal DIN rail space. Standard carriers like the IC200CHS002 mount modules horizontally. Additionally, the CHS025 features an extended operating temperature range for more rugged environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a special tool to operate the spring terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA standard small flat-head screwdriver suffices to depress the spring clamp. Once you insert the stripped wire and release the tension, the internal spring provides a constant, high-pressure contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this carrier with any VersaMax I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the IC200CHS025 supports the full range of VersaMax discrete and analog modules. However, verify that your cabinet depth can accommodate the vertical height of the module when plugged into this carrier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this carrier include the internal backplane bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The carrier includes the necessary connectors to link with adjacent carriers, forming a continuous internal communication and power bus for the VersaMax I\/O station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218267963482,"sku":"IC200CHS025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/22._59cabfcf-840e-4138-b5a0-c1799ac0e0d7.jpg?v=1776224801"},{"product_id":"ge-fanuc-ic200alg240-isolated-current-input-8-port","title":"GE Fanuc IC200ALG240 Isolated Current Input 8-Port","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG240 provides eight independent channels of isolated analog current input. Each channel supports a 4–20 mA signal range, making it compatible with the majority of industrial pressure, temperature, and flow transmitters. By utilizing 16-bit resolution, the module captures minute fluctuations in field data, ensuring the PLC CPU receives highly accurate information for PID loops and safety thresholds. This module integrates seamlessly into any VersaMax station, whether connected to a local CPU or a remote Network Interface Unit (NIU).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG240 utilizes advanced channel-to-channel isolation to prevent signal interference in complex electrical environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Bit (Significanly higher precision than 12-bit models)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and channel-to-backplane isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 ms (All channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Filtering\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz Notch filter for noise rejection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.25% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED Indicators: OK (Module Health), Field Power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 mA @ 5V Backplane; 120 mA @ 24V Field Power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Words (Input data)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG240 resolves specific industrial pain points through superior electronic design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Ground Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike non-isolated modules, the IC200ALG240 features channel-to-channel isolation. This hardware barrier prevents ground loop currents from distorting signal accuracy, even when sensors reside at different ground potentials across large facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Fidelity Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit architecture provides 65,536 discrete levels of signal interpretation. This capability allows engineers to monitor very fine process variables that 12-bit modules simply cannot detect.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated 50\/60 Hz notch filter automatically strips out electromagnetic interference (EMI) generated by nearby power lines and high-frequency drives. This ensures \"clean\" data reaching the CPU without requiring extensive software filtering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Power Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module continuously monitors the external 24VDC field power supply. If field power drops, the \"Field Power\" LED alerts technicians immediately, shortening the troubleshooting cycle during system commissioning or maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e100% Brand New Original Hardware\u003c\/h3\u003e\n\u003cp\u003eWe supply the GE Fanuc IC200ALG240 (including the GC revision) in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original factory packaging\u003c\/strong\u003e. This hardware remains the current active standard for the VersaMax line. Choosing new-in-box (NIB) modules ensures you receive factory-calibrated components with the latest firmware, avoiding the drift and hardware degradation common in used surplus or \"refurbished\" units.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC200ALG240 require a separate terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module installs onto a VersaMax terminal base (such as the IC200TBI001). The base provides the wiring points for the 8 current loops and the external 24VDC field power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the IC200ALG240-GC differ from the standard IC200ALG240?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"-GC\" suffix denotes a specific manufacturing revision. Functionally, it remains 100% interchangeable with earlier versions but includes updated internal components for enhanced reliability and compliance with current industrial standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure individual channels for voltage instead of current?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the IC200ALG240 is a dedicated current module (4-20mA). If your application requires voltage inputs (0-10V), you should select a multi-signal module like the IC200ALG264.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a wire breaks in the 4-20mA loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module detects under-range conditions. Since 4mA is the \"live zero,\" any signal falling significantly below 4mA indicates a broken wire or transmitter failure, which the module reports to the CPU fault table.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289683361882,"sku":"IC200ALG240-GC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/2.1_4e2b6412-63d1-4686-a955-44828859278d.jpg?v=1777444822"},{"product_id":"ic200alg260-ge-fanuc-8-point-mixed-analog-input-card","title":"IC200ALG260 GE Fanuc 8-Point Mixed Analog Input Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG260 provides 8 single-ended input channels, grouped into a single interface for efficient field wiring. It accepts a wide range of unipolar and bipolar signals, including 0 to +10V, -10 to +10V, and 4 to 20 mA. By integrating high-speed 12-bit A\/D conversion, the module ensures that the controller receives accurate representations of physical variables like pressure, temperature, and flow. This module mounts directly onto any VersaMax carrier, drawing its operating power from the backplane to simplify cabinet power distribution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG260 hardware utilizes professional-grade optical isolation to shield the logic backplane from external electrical surges.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Single-ended\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Ranges (Voltage)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +10V, -10V to +10V (Jumper Selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Ranges (Current)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-Bit (0 to 4095 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 ms per module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage: 126 kΩ (max); Current: 200 Ω (max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC continuous (Optical isolation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 mA @ 5V DC (Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK LED (Logic Power), INT PWR LED (Field Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG260 streamlines complex automation tasks through its flexible and resilient design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Signal Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField engineers often face mixed-signal environments. The IC200ALG260 allows for jumper-based selection between voltage and current modes, eliminating the need to stock multiple specialized modules for different sensor types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Logic Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an update rate of 0.4 ms, this module provides near-instantaneous data refresh. This speed proves critical for high-performance loops where delayed sensor data could cause process instability or mechanical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module draws a maximum of 130 mA from the 5V backplane. This low power footprint allows for higher I\/O density in a single rack without exceeding the capacity of standard VersaMax power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Fault Visibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual LED indicators (OK and INT PWR) allow for rapid visual troubleshooting. Technicians can immediately determine if a failure stems from the PLC backplane or a loss of internal field-side power, significantly reducing mean time to repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e100% Brand New Original Hardware\u003c\/h3\u003e\n\u003cp\u003eWe supply the GE Fanuc IC200ALG260 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original factory packaging\u003c\/strong\u003e. We guarantee the authenticity of every unit, ensuring that the hardware meets all original OEM tolerances and performance benchmarks. Using new-in-box (NIB) components prevents the drift and calibration issues often associated with aged or used analog hardware, providing a stable long-term solution for your facility.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC200ALG260 require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws its logic power (130mA) directly from the VersaMax backplane. However, you must provide field power to the carrier to energize the analog circuitry and connected sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between voltage and current modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou configure the input type via physical jumpers on the module or through the PLC configuration software (such as Proficy Machine Edition). Always ensure the hardware jumpers match your software settings to prevent measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum update rate for the 8 channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module refreshes its internal data every 0.4 ms. This provides a high-speed data stream that is suitable for most fast-acting industrial processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for differential inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200ALG260 is specifically designed for 8 single-ended inputs. If your application requires high noise immunity for low-level signals via differential wiring, we recommend checking modern high-resolution differential models in the VersaMax range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289721012314,"sku":"IC200ALG260","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/524..jpg?v=1777445811"},{"product_id":"versamax-ic200chs022l-compact-i-o-mounting-base-ge","title":"VersaMax IC200CHS022L Compact I\/O Mounting Base GE","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200CHS022L\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the foundational interface for the VersaMax I\/O system. This compact box-style carrier provides the mechanical mounting, electrical field wiring terminals, and the essential backplane communication interface for individual I\/O modules. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring maximum uptime for critical industrial control loops and automated manufacturing lines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 IEC-style terminals (A1–A18, B1–B18)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 32 I\/O points per module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–264 VAC (Tolerates transients up to 300 VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per point \/ 8 A total maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAWG #14–#22 (Single), AWG #18 (Dual)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN-rail or Panel Mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e163.5 mm x 66.8 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Cable Backplane Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated carrier-to-carrier connectors eliminate the need for external ribbon cables. Sliding the carriers together establishes the internal data bus instantly, reducing points of failure and speeding up assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Small Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing a vertical box-style design, the IC200CHS022L minimizes cabinet width. This allows engineers to fit more I\/O points into tight enclosures without sacrificing wiring accessibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Robustness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier withstands voltage spikes up to 300 VAC. This internal resilience protects sensitive I\/O electronics from the \"dirty\" power environments often found in heavy industrial plants or utility substations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA built-in wiring card holder allows technicians to label every connection point clearly. This prevents wiring errors during module replacement and shortens Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC200CHS022L support both AC and DC I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The carrier operates as a universal mounting base for the VersaMax series, supporting various I\/O types. Ensure the module's voltage requirements fall within the 0-264 VAC operating range of the carrier's terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between this and the 'CHS002' standard carrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IC200CHS022L is a \"Compact Box-Style\" carrier. It features a smaller footprint and IEC-style box terminals, whereas standard carriers often use barrier-style or extended terminal strips which occupy more horizontal space on the DIN rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How should I handle grounding for EMC compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Mount the carrier on a zinc-plated, yellow-chromate DIN rail. Ensure the DIN rail makes a solid connection to a low-impedance earth ground. This path dissipates electromagnetic interference and ensures the stability of high-speed backplane signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I install this carrier in high-vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For high-vibration applications, utilize the panel-mounting holes rather than relying solely on the DIN rail clips. Secure the carrier directly to a rigid backplate to prevent mechanical fatigue on the terminal connections.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289727795290,"sku":"IC200CHS022L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/525..jpg?v=1777446294"},{"product_id":"buy-ge-fanuc-ic200chs006-communication-carrier-original","title":"Buy GE Fanuc IC200CHS006 Communication Carrier Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200CHS006\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the essential backbone for the VersaMax I\/O system, acting as both a mechanical mounting base and a high-speed electrical interface. This communication carrier facilitates seamless data exchange between I\/O modules and the PLC backplane while providing secure termination for field devices. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak performance for your manufacturing and process control infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 IEC-style screw terminals (A1–A18, B1–B18)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Data Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 244 bytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Baud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 Kbaud to 12 Mbaud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC (Backplane) \/ Supports 0–264 VAC Field Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mA (Internal) \/ 2 A per point (Field)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm x 7.5 mm DIN rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAWG #14 to #22 (Solid or Stranded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (Standard) \/ -40°C to +70°C (Extreme Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CHS006 supports a broad network baud rate up to 12 Mbaud. This allows the carrier to handle complex, high-density data packets (up to 244 bytes) without causing latency in distributed control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact \"box-style\" architecture reduces footprint requirements within the electrical cabinet. Engineers can maximize I\/O density by snapping these carriers directly onto a standard 35mm DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTool-less Backplane Setup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated carrier-to-carrier connectors establish the internal communication bus instantly. This \"click-and-connect\" design eliminates external ribbon cables, significantly reducing assembly time and potential failure points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit tolerates voltage transients up to 300 VAC. This protection layer prevents field-side electrical noise and surges from damaging the sensitive PLC logic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA built-in wiring card holder provides immediate visual reference for field technicians, accelerating maintenance and reducing the risk of wiring errors during module swaps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the IC200CHS006 compatible with both standard and extended temperature environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. While standard operation covers 0°C to 60°C, the ruggedized design permits storage and specialized operation in environments ranging from -40°C to +70°C, making it suitable for unconditioned utility enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this carrier for high-speed PROFIBUS or Genius network modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. This communication carrier specifically supports the high-speed backplane requirements (up to 12 Mbaud) necessary for advanced communication interface modules within the VersaMax family.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this unit require a specific type of wiring for the IEC terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IC200CHS006 accommodates both solid and stranded copper wire. For dual-wire connections, use AWG #18. For single-wire runs, the terminals accept a range from AWG #14 to #22, providing high flexibility for different field device requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the carrier ensure EMC protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The carrier utilizes the DIN rail as a primary grounding path. To ensure proper shielding and EMC compliance, you must mount the carrier on a grounded, conductive (zinc-plated) DIN rail.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289736314970,"sku":"IC200CHS006","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/22_fdbafc66-c19f-4388-a739-fae8d7054354.jpg?v=1777446559"},{"product_id":"7-channel-16-bit-analog-input-unit-ic200alg630-ge-fanuc","title":"7-Channel 16-Bit Analog Input Unit | IC200ALG630 GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200ALG630\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision temperature sensing interface for the VersaMax I\/O family. This module provides seven independent channels designed to interface directly with Thermocouple types J, K, T, S, and R, or millivolt (mV) signals. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring laboratory-grade accuracy for demanding industrial thermal processing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermocouple (J, K, T, S, R) and Millivolt (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit (15 bits plus sign)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60ms\/channel (60 Hz) or 70ms\/channel (50 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.2% at 25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.15% at 25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 mA Max (5V) \/ 125 mA Max (3.3V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptical isolation between field and backplane logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED Indicators: Green (Power OK), Amber (Module Fault)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 mm x 66.8 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Thermal Tracking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit resolution (15 bits + sign) captures minute temperature fluctuations. This precision allows for tighter PID control loops in furnace management, chemical reactors, and plastic extrusion lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Thermocouple Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne module handles multiple thermocouple types (J, K, T, S, R) and raw mV inputs. This versatility reduces spare part inventory requirements across diverse facility assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes software-configurable filtering (50Hz\/60Hz) to eliminate power line interference. This ensures stable temperature readings even when installed near high-power motors or variable frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact High-Density Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeven channels occupy a standard VersaMax footprint, maximizing I\/O density on the DIN rail. This architecture lowers total system cost by reducing the number of carriers and modules required for multi-zone heating applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe intelligent LED system immediately alerts operators to module faults or backplane power loss. Built-in diagnostics report channel errors directly to the PLC, preventing process runs based on invalid data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC200ALG630 require external power for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The module draws its operating power directly from the VersaMax backplane (5V and 3.3V rails). However, ensure your power supply module has sufficient capacity for the 125mA maximum draw per rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle cold junction compensation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IC200ALG630 performs internal cold junction compensation automatically when paired with the appropriate VersaMax carrier. This ensures accurate temperature calculation by accounting for the ambient temperature at the terminal block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module for standard 4-20mA current loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The IC200ALG630 specifically targets Thermocouple and mV inputs. For 4-20mA or 0-10V signals, you should select the standard analog input modules from the VersaMax series, such as the IC200ALG240.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if a thermocouple wire breaks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module includes open-wire detection. Upon detecting a broken sensor wire, the module reports a fault status to the PLC and triggers the amber LED, allowing for immediate maintenance intervention.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289738477658,"sku":"IC200CH003K","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/527.jpg?v=1777446923"},{"product_id":"ic200alg620-dc-ge-fanuc-4-channel-analog-rtd-interface","title":"IC200ALG620-DC GE Fanuc 4-Channel Analog RTD Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200ALG620-DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers high-precision temperature monitoring for industrial automation via the VersaMax I\/O platform. This 4-channel module interfaces directly with Resistance Temperature Detectors (RTDs), converting thermal resistance into high-resolution 16-bit digital data. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the critical accuracy required for HVAC control, food processing, and chemical thermal management.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 RTD Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD (Supports common types like Pt100, Ni120)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC (Approx. 130 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC continuous (Optical isolation to logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.25% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 ms per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 mm x 66.8 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Thermal Sensing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit resolution provides superior granularity compared to standard 12-bit modules. This allows control systems to detect minute temperature shifts, improving product consistency in heat-sensitive manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Noise Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust optical isolation (250 VAC) separates the field-side RTD signals from the sensitive PLC backplane. This prevents ground loops and EMI from corrupting data, even in environments with heavy motor interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Data Refresh:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an update rate of 1 ms per channel, the IC200ALG620-DC supports high-speed process loops. This responsiveness prevents thermal overshoot in fast-acting heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features dedicated OK and PWR LEDs. These indicators provide instant visual verification of both backplane power status and field-side power health, significantly reducing diagnostic downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufactured in the USA and carrying the 8538909100 tariff code, this module meets rigorous international quality standards for industrial electronic equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC200ALG620-DC support 2-wire, 3-wire, or 4-wire RTDs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module primarily supports 3-wire RTD configurations to compensate for lead wire resistance. For 2-wire setups, you must jump the terminals at the carrier, though this may decrease accuracy over long distances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix different RTD types on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the hardware supports various RTD profiles, you must configure the software parameters in your GE Fanuc \/ Emerson programming environment (such as Proficy Machine Edition) to match the sensor type connected to each channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While VersaMax carriers allow for module removal, we recommend powering down the field-side power to prevent transients. Always ensure the \"OK\" LED is off before pulling the module from the carrier to maintain backplane integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle shield grounding for the RTD cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Connect the cable shields to the ground terminals on the VersaMax carrier. Ensure the DIN rail itself has a low-impedance connection to the main plant earth ground to maximize the module's built-in noise rejection capabilities.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289740378202,"sku":"IC200ALG620-DC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/15._02e896fd-64b0-4922-9262-074a91490086.jpg?v=1777447309"},{"product_id":"intelligent-platforms-plc-processor-ic200cpue05-fh-ge","title":"Intelligent Platforms PLC Processor | IC200CPUE05-FH GE","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200CPUE05-FH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the high-performance \"brain\" of the VersaMax PLC platform. This module integrates powerful 32-bit processing with embedded Ethernet connectivity, allowing it to manage complex logic, extensive I\/O mapping, and high-speed network communication simultaneously. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring total system integrity for critical infrastructure in energy management and manufacturing automation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-Bit Embedded CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 KB Program Memory \/ 64 KB Data Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 2048 I\/O Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated 10\/100 Mbps (RJ-45)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 and RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP, Modbus RTU, SNP, SRTP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 ms per 1K of logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTimers\/Counters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 \/ 512\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e350 mA @ 5 VDC (from backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Ethernet Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CPUE05-FH features a built-in 10\/100 Mbps Ethernet port. This eliminates the need for separate communication co-processors, simplifying your network architecture and enabling direct data exchange with SCADA systems and HMIs via Modbus TCP\/IP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Logic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 64KB of dedicated program memory and a rapid scan rate of 1ms per 1K of logic, this CPU handles complex PID loops and motion control sequences without latency, ensuring precise process synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports up to 2048 I\/O points. This scalability allows engineers to expand local and remote I\/O racks as facility requirements grow, protecting your initial hardware investment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Diagnostics Suite:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn internal watchdog timer and self-diagnostic firmware constantly monitor the CPU's health. The module immediately reports hardware faults or memory parity errors via LED indicators and system registers, preventing erratic machine behavior.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy combining the CPU and network interface into a single 50mm-wide module, the IC200CPUE05-FH reduces the overall PLC footprint. This allows for smaller control cabinets and lower cooling requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC200CPUE05-FH support Modbus TCP communication out of the box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The integrated Ethernet port supports both Modbus TCP\/IP and GE's native SRTP protocol. This allows for seamless integration with third-party devices like VFDs, power meters, and other PLCs without additional gateways.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I store the program in the event of a power failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes non-volatile flash memory for long-term program storage. For retentive data (registers and variables), we recommend using a standard battery to maintain the internal CMOS RAM during extended power-down periods.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I upgrade a system using an older IC200CPU001\/002 to this Ethernet-enabled model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Generally, yes. The IC200CPUE05-FH fits the same VersaMax carriers. You will need to update your hardware configuration in Proficy Machine Edition and ensure your logic resides within the 64KB memory limit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the \"-FH\" suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"-FH\" suffix typically denotes specific firmware revisions or hardware manufacturing batches under GE Intelligent Platforms (now Emerson). It remains fully compatible with standard VersaMax I\/O modules and carriers.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289744310362,"sku":"IC200CPUE05-FH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/528..jpg?v=1777447902"},{"product_id":"ic200erm001c-ge-fanuc-emerson-isolated-expansion-receiver","title":"IC200ERM001C GE Fanuc Emerson Isolated Expansion Receiver","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200ERM001C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the critical link in high-scale VersaMax PLC architectures. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eisolated expansion receiver module accepts high-speed signals from a transmitter (such as the IC200ETM001) and distributes them across local expansion racks. By providing electrical isolation, it protects the CPU from ground loops and signal interference across multi-rack setups, ensuring seamless data integrity in demanding manufacturing and utility environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ERM001C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax PLC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 26-Pin Female D-Shell Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 V (Min) to 5 V (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully Isolated between expansion racks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-board Rotary Switch for Rack ID\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED for Power and Expansion Bus Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLeftmost slot of expansion rack (DIN Rail)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ERM001C eliminates electrical noise and voltage differentials between the main CPU rack and remote expansion racks. This isolation prevents hardware damage and data corruption in environments with heavy electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Daisy-Chain Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual D-shell ports allow engineers to link multiple racks in a series. The module receives the incoming signal and passes it through to the next receiver, simplifying complex wiring layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated rotary switch enables immediate hardware-level rack ID assignment. This eliminates the need for complex software configuration during initial setup or module replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCritical Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-visibility LEDs provide real-time feedback on the expansion bus health and power status, significantly reducing downtime during troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines \u0026amp; Application Tips\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal performance, always install the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ERM001C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eleftmost slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the expansion rack. It must be paired with an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ETM001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransmitter located in the main or previous rack. Ensure all D-shell cables are shielded and securely fastened to the ports to maintain signal continuity across the bus.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the IC200ERM001C without a transmitter module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. This module is a receiver. It requires an IC200ETM001 (or compatible transmitter) to provide the upstream communication signal from the CPU rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a separate external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. The IC200ERM001C draws its operating power directly from the backplane power supply installed on the expansion rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the rotary switch?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA: The rotary switch sets the unique Rack ID for the expansion rack. This allows the CPU to correctly address and identify the I\/O modules located in that specific rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the \"C\" version compatible with older IC200ERM001 versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, the \"C\" suffix typically denotes a later hardware revision or firmware update, but it maintains backwards compatibility with existing VersaMax expansion systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289751289946,"sku":"IC200ERM001C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/529.jpg?v=1777448190"},{"product_id":"emerson-ic200erm002c-versamax-plc-expansion-bus-interface","title":"Emerson IC200ERM002C VersaMax PLC Expansion Bus Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200ERM002C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-speed communication gateway for expanded VersaMax PLC architectures. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eisolated expansion receiver module bridges the gap between the main CPU and peripheral racks, maintaining signal integrity over distances up to 50 feet. It facilitates the distribution of I\/O and communication signals across large-scale manufacturing and utility deployments, ensuring the central processor maintains deterministic control over remote modules.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ERM002C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax PLC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Mbps \/ 2.765 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Multi-Rack Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 feet (15 meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Single-Ended Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 feet (1 meter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 mA @ 5V \/ 20 mA @ 3.3V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 26-pin Female D-shell connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAddressing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-board Rotary Switch for Rack ID\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Electrical Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Monitoring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower and Expansion Bus LED Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Indoor Use)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports data transfer rates up to 5 Mbps, minimizing latency in complex multi-rack configurations and ensuring rapid I\/O updates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated electrical isolation protects the system backplane from ground loops and external electromagnetic interference (EMI), a critical requirement in heavy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Expansion Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual D-shell connector design enables \"daisy-chain\" wiring. Engineers can connect multiple expansion racks in a series, significantly reducing cable complexity and cabinet clutter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLED diagnostics provide immediate visual confirmation of power status and bus activity. This allows field technicians to isolate communication faults within seconds without specialized diagnostic tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe manual rotary switch allows for physical Rack ID assignment, preventing software-based addressing conflicts and ensuring the CPU correctly maps local I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between IC200ERM002 and the \"C\" version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe \"C\" suffix indicates a hardware revision that maintains full backwards compatibility with the original IC200ERM002. It serves as a direct drop-in replacement for older versions within the VersaMax series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhere must I install this module in the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYou must install the IC200ERM002C in the leftmost slot (the first slot) of the expansion rack to properly interface with the backplane and power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable should I use for maximum distance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTo achieve the maximum 50-foot multi-rack distance, you must use high-quality, shielded expansion cables compatible with the 26-pin D-shell ports to prevent signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require its own power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe module draws its operating current from the backplane power supply. Ensure your installed power supply module provides sufficient 5V and 3.3V current for all modules in that specific rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289763610714,"sku":"IC200ERM002C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/530.1.jpg?v=1777448522"},{"product_id":"brand-new-ge-ic200mdl940j-versamax-plc-output-card","title":"Brand New GE IC200MDL940J VersaMax PLC Output Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200MDL940J\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density discrete output interface within the VersaMax PLC ecosystem. This module provides 16 isolated Form A (normally open) relay outputs, allowing the controller to drive heavy-duty field devices like solenoids, contactors, and motor starters. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system maintains maximum uptime with factory-fresh mechanical relay life.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL940 series utilizes specific letter suffixes to denote hardware revisions and manufacturing batches. While the core functionality remains consistent, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"J\" revision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the latest hardware optimization for improved component longevity.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIC200MDL940A\/B:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInitial production series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIC200MDL940H:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntermediate hardware revision with updated internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIC200MDL940J:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCurrent high-standard revision (Fully backward compatible with A, B, and H).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL940J balances high-current capacity with a compact footprint:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Isolated Points (Form A - Normally Open)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–240 VAC \/ 5–220 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Amps per point (resistive) \/ 4 Amps max per common\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e480 VA (AC) \/ 90 Watts (DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC continuous (Optical isolation to logic ground)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms maximum (ON\/OFF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mA @ 5 VDC from backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAWG #14 to #22 (Supports solid or stranded copper)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL940J addresses several critical pain points in industrial cabinet design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMixed Load Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike Triac or Transistor modules, these relay outputs manage both AC and DC voltages simultaneously across different commons. This flexibility eliminates the need for multiple output cards when controlling diverse field components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Current Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivering 2 Amps per point in a 66.8mm wide module allows engineers to drive larger contactors directly. This removes the cost and space requirements of intermediate \"slaving\" interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical isolation shields the sensitive PLC backplane logic from inductive kicks and electrical noise generated by field actuators. This architecture prevents CPU resets and data corruption in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual green LED indicators map directly to each output point. This allows maintenance teams to verify logic execution at a glance without probing terminals, significantly reducing troubleshooting time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older IC200MDL940A with the IC200MDL940J?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"J\" revision is a direct, functional drop-in replacement for all previous versions (A through H). It fits the same VersaMax base and requires no software logic changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply for the relays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws its logic power (120mA) from the PLC backplane, but the power for your field loads must come from an external source wired through the relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the mounting requirements for high-vibration areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module snaps securely onto the VersaMax I\/O carrier. For high-vibration applications, ensure you use the carrier's integrated DIN-rail locking mechanism and verify all screw terminal connections to AWG #14-#22 specifications to prevent mechanical loosening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit suitable for high-frequency switching?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the IC200MDL940J uses mechanical relays, it has a finite mechanical life. For applications requiring rapid-fire switching (e.g., PWM or high-speed pulsing), we recommend GE's solid-state transistor output modules instead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289780027482,"sku":"IC200MDL940J","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/531..jpg?v=1777449885"},{"product_id":"brand-new-ge-ic200ebi001-modbus-tcp-ethernet-niu","title":"Brand New GE IC200EBI001 Modbus TCP Ethernet NIU","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200EBI001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-speed communication backbone for VersaMax expansion racks. This Ethernet Network Interface Unit (NIU) enables a central CPU to manage remote I\/O modules over a 10\/100Mbaud network. It supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet Global Data (EGD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserver protocols, facilitating seamless integration into multi-vendor automation architectures. We provide this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-speed data integrity for large-scale industrial deployments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC200EBI001 delivers robust data handling capacities within a standard VersaMax footprint:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEGD (Ethernet Global Data) or Modbus TCP Server\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1024 Bytes total (Discrete and Analog)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbaud (Auto-negotiating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 modules per NIU station\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 meters (Twisted pair media)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26-pin D-shell for bus \/ RJ-45 for Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mA from rack backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e133.4 mm x 85.9 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC200EBI001 solves critical infrastructure challenges in distributed control systems:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module allows engineers to distribute I\/O racks across large facilities (up to 100m drops) without degrading signal timing. It eliminates the need for expensive, long-run multi-core copper wiring by utilizing standard Ethernet infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting both EGD and Modbus TCP, the IC200EBI001 communicates simultaneously with GE CPUs and third-party SCADA or HMI systems. This dual-protocol capability reduces the cost of protocol converters and gateways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard rotary switch allows for physical Rack ID selection. This hardware-level addressing ensures that the CPU correctly identifies expansion racks even after a firmware update or network reset, preventing addressing conflicts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated electrical isolation between the expansion bus and the internal logic protects the main control rack from field-side electrical surges and EMI interference common in heavy utility and energy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhere exactly should I install the IC200EBI001 in the expansion rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must install the module in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eleftmost slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Slot 0) of the expansion carrier. This position allows the module to initialize the backplane power and manage the data flow for the subsequent 8 I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support fiber optic connections?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200EBI001 features an Ethernet twisted pair interface. If your site requires fiber optic runs for long distances or extreme EMI environments, you must use an external media converter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum I\/O capacity per station?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach NIU station supports up to 1024 bytes of combined discrete and analog data. This allows for high-density configurations across 8 attached modules while maintaining 10\/100Mbaud throughput.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the diagnostic LEDs assist in troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front-facing LEDs provide real-time status for \"Power,\" \"Module OK,\" and \"Network Activity.\" A flashing status LED typically indicates a configuration mismatch or an addressing error on the rotary switch, allowing for rapid visual diagnostics without a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289784975450,"sku":"IC200EBI001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/529_b3658a83-aa50-4fad-be07-ad9b393b3243.jpg?v=1777450304"}],"url":"https:\/\/www.spareoil.com\/collections\/ge-versamax.oembed?page=6","provider":"SpareOil Automation","version":"1.0","type":"link"}