{"title":"Probes, Sensors \u0026 Transducer","description":"\u003cp\u003eAchieve precision measurement with our collection of original Probes, Sensors, and Transducers. \u003cspan class=\"citation-13 citation-end-13\"\u003eSpecializing in condition monitoring, we offer a wide range of Bently Nevada proximity sensors, velocity transducers, and temperature probes.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e These 100% genuine sensors are critical for identifying vibration, thrust, and displacement in rotating machinery, helping you prevent failures before they happen.\u003c\/p\u003e","products":[{"product_id":"abb-ntr002-a-temperature-sensor-interface-module-rtd-tc","title":"ABB NTR002-A Temperature Sensor Interface Module RTD TC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB NTR002-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision, 2-channel temperature interface module designed for the S800 I\/O family and Symphony Plus systems. This module converts low-level signals from industrial thermal sensors into high-resolution digital data for the DCS. It provides universal input support, handling both Resistance Temperature Detectors (RTDs) and Thermocouples (TC) with exceptional linearity. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical thermal loops in power generation and chemical processing benefit from 16-bit conversion accuracy and robust galvanic isolation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNTR002-A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Independent, Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Bit Analog-to-Digital Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–200 °C to +1800 °C (Sensor Dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported RTDs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100, Pt1000, Cu10, Ni100, Ni120\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Thermocouples\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTypes J, K, T, E, R, S, B, N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation (Channel-to-Channel \u0026amp; Channel-to-Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–25 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mm × 265 mm × 115 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Sensor Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NTR002-A eliminates the need for separate RTD and Thermocouple modules. A single unit manages diverse sensor types, including platinum RTDs and high-temperature noble metal thermocouples (Types R, S, B), streamlining your spare parts inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Fidelity Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing a 16-bit high-precision converter, the module detects minute temperature shifts that standard 12-bit modules miss. This level of sensitivity proves vital for tight temperature control in reactor vessels and steam turbine monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile many I\/O modules fail at 50 °C, the NTR002-A operates reliably up to +70 °C. This industrial-wide temperature rating permits installation in cabinets located near process heat sources without requiring supplemental forced-air cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGalvanic isolation between channels prevents ground loops and protects the system bus from high-voltage transients on the field side. This architecture ensures that a localized electrical fault on one sensor does not propagate through the entire DCS backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NTR002-A support cold junction compensation for thermocouples?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The NTR002-A includes internal cold junction compensation circuitry to ensure accurate thermocouple readings. You can also configure external compensation via the S800 terminal base for even higher precision in environments with fluctuating cabinet temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the module for different sensor types like Pt100 vs. Type K?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfiguration occurs through the ABB control software (e.g., 800xA, Symphony Plus, or Freelance). You select the specific sensor profile per channel in the I\/O configuration hardware tree, and the module automatically adjusts its excitation current or gain settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable in an S800 I\/O rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NTR002-A supports \"Removal and Insertion Under Power\" (RIUP) when used with compatible S800 active backplanes. This allows you to replace a unit without interrupting the power or communication of adjacent modules in the same cluster.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat protection features does the module include against wiring errors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features integrated over-voltage and over-current circuit protection. These safety layers prevent damage to the 16-bit converter if a field technician accidentally connects a higher voltage source to the signal terminals during commissioning.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42870823878746,"sku":"NTR002-A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/116._55344b5e-c4f9-4971-ab9d-6ce2f489d762.jpg?v=1771897727"},{"product_id":"9200-01-01-01-00-bently-nevada-velocity-transducer-new-stock","title":"9200-01-01-01-00 Bently Nevada Velocity Transducer | New Stock","description":"\u003ch1\u003eBently Nevada 9200-01-01-01-00 9200 Series Seismoprobe Velocity Transducer\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-01-01-01-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBently Nevada 9200\u003c\/strong\u003e Seismoprobe Two-Wire Velocity Transducer, operates as a dedicated hardware component for absolute vibration velocity measurement within machine casing and structural monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9200\u003c\/strong\u003e : Base Series Moving-Coil Seismoprobe Velocity Transducer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e (Mounting Orientation) : Horizontal mount construction, valid within a $\\pm2.5$ deg C plane variance limit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e (Connector Option) : Top-mounted terminal block interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e (Mounting Base) : Circular configuration with a 1\/4-20 UNC threaded stud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e (Agency Approval) : Standard industrial design containing no specific hazardous area certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e9200-01-01-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.3 kg transducer mass unit \/ 2.0 kg total shipping weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e41.4 mm diameter base cross section\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to 120 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSelf-generating passive permanent-magnet moving-coil loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eFrequency Response Range\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e4.5 Hz to 1,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eThread Format\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1\/4-20 UNC American standard threading pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eExternal Interface\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eTwo-wire differential transmission interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Correlation\u003c\/h3\u003e\n\u003cp\u003eThis electro-mechanical device measures structural velocity signatures directly without relying on active integrated conversion electronics. When deployed alongside proximity probe systems, this moving-coil assembly allows structural vibration data to combine with internal eddy-current probe scaling matrices to plot absolute shaft motion across complex rotor dynamics profiles. This passive system suppresses cross-talk interference from high-frequency structural noise because the physical mass distribution of the internal spring-suspended coil dampens impulse spikes. Consequently, the sensor provides direct integration into industrial monitoring backplanes without requiring high-impedance charge pre-amplifiers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 9200-01-01-01-00 variant be mounted vertically or at an arbitrary angle?\u003c\/p\u003e\n\u003cp\u003eA: No. This specific model features Option 01 for the internal mechanical alignment mechanism, which restricts operation to a strict horizontal plane with a maximum allowed tolerance of $\\pm2.5$ degrees.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current draw requirements for this transducer loop?\u003c\/p\u003e\n\u003cp\u003eA: The device contains a passive moving-coil architecture that requires 0 mA of external backplane supply current. It functions as a self-generating electromechanical transducer, creating its own millivolt signal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the machine surface mounting pad is flat, clean, and machined perpendicular to the intended horizontal measuring axis.\u003c\/li\u003e\n\u003cli\u003eTorque the 1\/4-20 UNC threaded stud configuration to standard engineering limits to prevent structural mechanical attenuation at higher frequencies.\u003c\/li\u003e\n\u003cli\u003eTerminate the two-wire differential signal line using a continuous twisted shielded pair to prevent electromagnetic noise induction from nearby power conduits.\u003c\/li\u003e\n\u003cli\u003eGround the outer cable shield layer at the monitoring chassis terminal block end only, maintaining absolute isolation at the sensor casing head.\u003c\/li\u003e\n\u003cli\u003eRoute the wiring bundle with sufficient slack loops to prevent structural displacement tensions from impacting the physical alignment of the sensor housing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870824108122,"sku":"9200-01-01-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/77_20c46042-3192-4dba-ba3b-66f0f724df4e.jpg?v=1770947748"},{"product_id":"8290-048-woodward-generator-load-sensor-datasheet-technical-manual","title":"8290-048 Woodward Generator Load Sensor Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eWoodward 8290-048 Parallel Load Sharing Control Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8290-048\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8290-048\u003c\/strong\u003e Generator Load Sensor and Control Module, serves as the primary \u003cstrong\u003e8290-048\u003c\/strong\u003e Parallel Load Sharing Control utilized to execute automatic synchronizing and proportional load sharing across parallel engine-generator platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8290-048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Woodward load sensor panel-mount footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eDual 115\/230 VAC nominal (95-130 \/ 190-260 VAC operational)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Transformer Input\u003c\/td\u003e\n\u003ctd\u003e5 A Secondary (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Adjustments\u003c\/td\u003e\n\u003ctd\u003eMulti-turn potentiometers for Droop and Load Gain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eProportional DC bias for speed governors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade ruggedized metal housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003ePanel or Sub-panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Drives, Governors, and Speed Control Properties\u003c\/h3\u003e\n\u003cp\u003eThe controller monitors physical generator voltage and line current vectors to track active kilowatt (kW) distribution in real time. The calculated outputs interface directly with the primary engine governor, generating a proportional DC bias signal that modulates the actuator loop feedback response time boundaries during sudden grid transitions. Built-in multi-turn potentiometers handle on-site fine-tuning of the Droop and Load Gain vectors, enabling exact system response matching to counteract severe speed variations. Internal electrical networks optimize harmonic distortion suppression across the voltage measurement inputs, protecting the control tracking algorithms from variable-frequency excitation interference inside the genset panel.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 8290-048 prevent reverse-power faults in multi-engine parallel networks?\u003c\/p\u003e\n\u003cp\u003eA: The module continuously monitors the phase and magnitude of the incoming 5 A current transformer line against the generator terminal voltage. If a unit stops producing active kW and begins motoring, the internal load sensing logic computes the negative bias drop immediately, letting the governor firmware trip safety contacts before structural reverse-power damage occurs.\u003c\/p\u003e\n\u003cp\u003eQ: What physical inputs are required to configure the speed biasing circuit for dual-voltage operation?\u003c\/p\u003e\n\u003cp\u003eA: The hardware accommodates separate, selectable jumper or terminal links on the chassis for 115 VAC or 230 VAC operational baselines. Field wires connect to distinct terminal points, matching input limits from 95-130 VAC or 190-260 VAC without needing external step-down transformers.\u003c\/p\u003e\n\u003cp\u003eQ: Can the Droop and Load Gain adjustments be modified while the engine-generator set is online?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the front-panel multi-turn potentiometers permit real-time modification of the droop slope and gain parameters. This enables the engineering team to calibrate system stability under live operating conditions while watching active frequency deviations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Transformer Polarity Routing:\u003c\/strong\u003e Ensure the standard 5 A secondary current transformer (CT) wires are oriented with absolute physical phase alignment relative to the generator voltage sense lines. Reversed CT polarity will cause incorrect internal kW calculations and lead to instant load imbalance faults during synchronization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding of Governor Bias Output Lines:\u003c\/strong\u003e Route the proportional DC speed bias output signals using independent twisted-pair, shielded cables. Connect the shield drain wire solely at the governor chassis ground block to prevent electromagnetic interference from distorting the reference voltage loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSub-panel Convective Air Orientation:\u003c\/strong\u003e Mount the ruggedized metal housing vertically onto a rigid panel structure away from high-temperature exhaust paths. Maintain clear space around the chassis borders to promote natural airflow and keep ambient operational limits below +70 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":42870826336346,"sku":"8290-048","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/197_f6867332-97ab-4153-8332-a9588b363901.jpg?v=1772767534"},{"product_id":"bently-nevada-16710-10-10ft-vibration-sensor-armored-cable","title":"Bently Nevada 16710-10 10ft Vibration Sensor Armored Cable","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 16710-10 acts as a high-fidelity signal bridge between field transducers and the monitoring rack within 3300 and 3500 Machinery Protection System architectures. This 10-foot (3.05m) interconnect cable carries sensitive -200 mV\/µm vibration and proximity signals while maintaining total data integrity. Engineered for the harshest industrial sectors, the cable utilizes an interlocked stainless steel armor sheath to defend against crushing and mechanical abrasion. It serves as the vital link that ensures dynamic vibration signatures reach the protection system without attenuation or environmental interference.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProfessional Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16710-10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Feet (3.05 Meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree 22 AWG Stranded Tinned Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Construction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterlocked Stainless Steel Braid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-layer (Aluminum Foil + Tinned Copper Braid)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOil-resistant Black PVC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Pin Circular MS-style Plug\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector B\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePre-crimped Insulated Terminal Lugs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 V RMS (Signal Level)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C (-40 °F to 185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAPI 670, CE, UL, cUL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 16710-10 provides specialized electrical and physical defenses to solve common machinery monitoring failures:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior EMI\/RFI Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-layer shielding system (aluminum foil combined with a tinned copper braid) achieves over 85% coverage. This rejects electromagnetic interference from nearby high-voltage equipment, preserving the accuracy of low-voltage shaft position measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Crushing Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe interlocked stainless steel armor prevents signal degradation caused by cable pinching, foot traffic, or heavy tooling impacts. This robust sheath maintains the internal cable geometry, which is critical for consistent impedance and signal timing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil-Hardened Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe specialized black PVC outer jacket resists degradation from turbine oils, lubricants, and common industrial chemicals. This prevents the cable from becoming brittle or shorting out in the fluid-rich environments of power plants and refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure MS-Style Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe factory-terminated 3-pin circular MS-style plug provides a positive-locking, vibration-proof connection to Bently Nevada proximity probe extension cables. This ensures the signal path remains intact despite the constant mechanical oscillation of the machinery housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Bently Nevada 16710-10 cable 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the 16710-10 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition. Each cable arrives in its factory-sealed packaging, ensuring that the connectors and armor meet the highest OEM quality standards for machinery protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable support 3300 XL and 9000 series probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Bently Nevada optimized the 16710-10 specifically for the signal characteristics of the 3300 XL and 9000 series proximity systems. It maintains the required sensitivity and impedance for these API 670 compliant systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 16710-10 and shorter versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"-10\" suffix denotes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10-foot (3.05-meter)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elength. While the electrical and mechanical properties remain identical to the 16710-08 (8ft), the additional length provides more flexibility for routing through complex conduit paths or larger machine enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre the terminal lugs ready for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Connector B features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epre-crimped insulated terminal lugs\u003c\/strong\u003e. This allows for immediate termination into the terminal blocks of a 3500\/15 power supply or 3500\/42M monitor without requiring specialized field crimping tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870827515994,"sku":"16710-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/232.2.jpg?v=1776761054"},{"product_id":"990-04-70-02-00-bently-nevada-7m-system-vibration-monitor","title":"990-04-70-02-00 Bently Nevada 7m System Vibration Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 990-04-70-02-00 functions as a self-contained, 2-wire vibration transmitter that bridges the gap between proximity probes and plant control systems. This device converts the complex dynamic signal from a 3300 NSv proximity probe into a standardized 4–20 mA analog output. By providing a signal linearly proportional to peak-to-peak vibration displacement, it enables direct interfacing with PLCs, DCS, or SCADA platforms without the need for a dedicated 3500 rack. This module specifically serves critical rotating machinery where a simplified architecture and a 0–4 mil measurement range are required for API 670 compliant protection.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e990\u003c\/strong\u003e: 990 Series Vibration Transmitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04 (Full-Scale Range)\u003c\/strong\u003e: 0–4 mils pp (0–100 µm pp).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e70 (System Length)\u003c\/strong\u003e: 7.0 Meters (23.0 Feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Mounting Option)\u003c\/strong\u003e: Panel Mount (Standard screws).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Agency Approval)\u003c\/strong\u003e: No specific hazardous area approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eProfessional Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC (Loop-powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–4 mils pp (0–100 µm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Proximity Probe + Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 Meters (Total Electrical Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1,000 Hz (600 to 60,000 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+18 to +30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66 \/ NEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–35 °C to +85 °C (–31 °F to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount (4-bolt pattern)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan class=\"mat-mdc-button-persistent-ripple mdc-button__ripple\"\u003e\u003c\/span\u003e\u003cspan class=\"mdc-button__label\"\u003e\u003cspan class=\"export-sheets-button\"\u003e\u003cspan class=\"export-sheets-icon\"\u003e\u003c\/span\u003e导出到 Google 表格\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mat-focus-indicator\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-mdc-button-touch-target\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-mdc-button-persistent-ripple mdc-icon-button__ripple\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-focus-indicator\"\u003e\u003c\/span\u003e\u003cspan class=\"mat-mdc-button-touch-target\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 990-04-70-02-00 solves integration challenges in modern industrial automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect PLC\/DCS Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis transmitter eliminates the cost and space requirements of a centralized monitoring rack. It outputs a standard 4-20mA loop signal, allowing existing control system I\/O cards to handle vibration data as a standard process variable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for 3300 NSv Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 990 series specifically supports the 3300 NSv probe line, which features a smaller tip diameter and tighter side-clearance requirements. This makes the 990-04-70-02-00 ideal for small-bore piping, fluid-film bearing motors, and centrifugal compressors with limited probe mounting space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized NEMA 4X Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IP66-rated enclosure allows for mounting directly at the machine base or in local junction boxes. The circuit design withstands extreme temperature fluctuations and high-moisture environments typical of power generation and petrochemical facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Loop Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transmitter maintains a specific \"Not OK\" current level (typically \u0026lt;3.6 mA) if it detects a transducer failure or cable disconnect. This hardware-level diagnostic ensures that the control system can distinguish between zero vibration and a sensor fault, preventing \"blind\" operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Bently Nevada 990-04-70-02-00 unit brand new?\u003c\/strong\u003eYes. We supply the 990-04-70-02-00 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition. Each unit arrives in its original factory packaging, ensuring the internal calibration and loop-power circuitry meet all OEM performance benchmarks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat probe and cable length must I use with this transmitter?\u003c\/strong\u003eThis specific unit (70 option) requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e7.0-meter total system length\u003c\/strong\u003e. You must use a 3300 NSv probe and extension cable that combined equal exactly 7.0 meters. Using a 5.0m or 9.0m system will result in significant calibration errors and inaccurate 4-20mA readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mount this transmitter on a DIN rail?\u003c\/strong\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emounting option designates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePanel Mount\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration. While it lacks the pre-installed DIN rail clips found on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant, you can mount it directly to a backplate using the provided bolt holes. If your cabinet requires DIN mounting, ensure you have the appropriate adapter or specify the 01 model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this transmitter require an external power supply?\u003c\/strong\u003eThe 990-04-70-02-00 is a loop-powered device. It requires an external\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+18 to +30 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower source, typically provided by the analog input card of your PLC or DCS. It regulates the current on the loop to represent the measured vibration level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870827679834,"sku":"990-04-70-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/233_c30a7efd-4e88-4f0a-90fa-2a34f2bc95ce.jpg?v=1776761217"},{"product_id":"bently-nevada-3300-10-02-02-00-vibration-monitoring-power","title":"Bently Nevada 3300\/10-02-02-00 Vibration Monitoring Power","description":"\u003ch3\u003e\u003cstrong\u003eBently Nevada 3300\/10-02-02-00 3300 Series Rack Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Power Supply Module engineered to deliver stabilized DC power to the Bently Nevada 3300 Series machinery protection and condition monitoring system. Functioning as the primary energy hub for the rack, it converts standard AC line voltage into the regulated DC rails required by up to 12 monitoring modules and their associated transducers (supporting up to 36 channels total). Designed for mission-critical turbomachinery applications, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports dual-redundant configurations, ensuring that a single power supply failure does not compromise the vibration monitoring of essential assets like turbines, compressors, and large motors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to exacting industrial standards, featuring EMI shielding and passive cooling for long-term durability.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: 3300 Vibration Monitoring System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 115 VAC (95–125 VAC) or 230 VAC (190–250 VAC), 47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Performance\u003c\/strong\u003e: Regulated DC output for rack-wide distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e: Powers up to 12 monitors and 36 transducers per rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e: Supports 1:1 power supply redundancy for fault tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e: Passive convection cooling (fanless design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e: Aluminum alloy with integrated EMI shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to +60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: Up to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.8 kg (1.76 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 16 cm × 16 cm × 12 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE, UL, CSA compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870828466266,"sku":"3300\/10-02-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/72.1_d889be97-269c-4f87-8831-954d10585e18.jpg?v=1770945984"},{"product_id":"emerson-a6312-08-2-channel-speed-monitoring-card-api-670emerson-a6312-08-2-channel-speed-monitoring-card-api-670","title":"Emerson A6312\/08 | 2-Channel Speed Monitoring Card API 670Emerson A6312\/08 | 2-Channel Speed Monitoring Card API 670","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6312\/08 (Model: A6312\/08)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, two-channel speed and phase reference monitoring module designed for the Emerson AMS 6500 Machinery Health Monitor system. This module is critical for acquiring accurate shaft rotational data, which serves as the fundamental \"timing clock\" for advanced vibration diagnostics. By processing signals from proximity probes or magnetic pickups, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6132\/08 (Part Number: A6312\/08)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables synchronous sampling and order tracking, allowing vibration peaks to be correlated with the specific angular position of a rotor.\u003c\/p\u003e\n\u003cp\u003eAs an API 670 compliant protection card, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6312\/08 (Series: AMS 6500)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides mission-critical machinery safety. The \"\/08\" designation represents a hardware revision optimized for high-speed signal processing and enhanced noise immunity. Its compact 3U design facilitates high-density integration within the AMS 6500 rack while supporting hot-swappable replacement and integrated self-diagnostics to ensure continuous protection for power generation and petrochemical assets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6312\/08\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides deterministic monitoring of rotational speed and phase reference signals.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson (EPRO\/CSI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6312\/08\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e: AMS 6500 Machinery Health Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Speed \/ Phase Reference Monitoring Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: 2 Independent Channels (Speed and\/or Key Phase)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI Compliance\u003c\/strong\u003e: Fully compliant with API 670 standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Sensors\u003c\/strong\u003e: Proximity probes, Magnetic pickups, Hall Effect sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Frequency Range\u003c\/strong\u003e: 0.01 Hz to 20,000 Hz (High-speed capability)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e: Front SMB and Rear terminals for raw signal analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProportional Outputs\u003c\/strong\u003e: 0\/4–20 mA or 0–10 V (Configurable via software)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogic\/Alarming\u003c\/strong\u003e: Independent alarm and danger thresholds per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Features\u003c\/strong\u003e: Cable integrity check, hardware self-monitoring, temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Format\u003c\/strong\u003e: 3U Size, 1-Slot Plug-in Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 4 cm x 19 cm x 12.8 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.28 kg (0.62 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42870829318234,"sku":"A6312\/08","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/211.jpg?v=1772075490"},{"product_id":"a6312-06-emerson-epro-api-670-speed-monitoring-module","title":"A6312\/06 Emerson EPRO API 670 Speed Monitoring Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Emerson EPRO A6312\/06 operates as a high-precision, dual-channel speed and phase monitoring module designed for the AMS 6500 (CSI 6500) Machinery Health Monitor system rack. This 3U plug-in card functions as the master synchronization engine for the entire monitoring chassis, capturing raw high-frequency pulses from eddy current proximity probes, magnetic pickups, or Hall-effect sensors. Turbomachinery maintenance teams rely on this module to compute precise rotational speeds (RPM), detect zero-speed conditions, and establish phase reference angles (Keyphasor) to execute advanced synchronous vibration analysis and order tracking on critical industrial shafts.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturer: Emerson (CSI \/ EPRO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: A6312\/06\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHardware Revision Level: Revision 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Chassis Series: AMS 6500 \/ CSI 6500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensor Input Density: 2 Independent, Configurable Channels (Speed \/ Phase Reference)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Transceiver Compatibility: Eddy current proximity sensors, Hall-effect pulses, magnetic pickups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNative Operating Modes: Speed tracking (RPM), Zero Speed monitoring, Phase angle reference, Frequency calculations (Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCore Industry Standard Compliance: API 670 (Machinery Protection Systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuffered Signal Interfaces: Front-panel SMB coaxial ports and rear terminal connections for raw pulses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Proportional Retransmission: Programmable 0–20 mA, 4–20 mA current loops, or 0–10 V DC voltage outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete Data Interface: TTL-compatible pulse outputs for connection to external analyzer platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous Diagnostic Monitoring: Active sensor power verification, field cable open\/short tracking, internal board temperature logs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Form Factor Dimensions: Standard 3U European card profile (Plug-in architecture)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLive Service Capabilities: Supports active hot-swap module replacement during rack runtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePermissible Operating Temperatures: 0 to +55 degrees Celsius (32 to 131 degrees Fahrenheit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComponent Production Condition: 100% Brand New and Original in Factory Packing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eAPI 670 Compliant Architecture Delivers Real-Time Machinery Protection\u003c\/h3\u003e\n\u003cp\u003eThe A6312\/06 processes transient signal inputs over a dedicated dual-channel path to satisfy strict API 670 machinery protection execution guidelines. The module computes speed steps independently of the main rack processor, triggering proportional analog and TTL outputs within millisecond deadlines. This autonomous processing speed ensures that oversensing circuitry activates emergency trip interlocks instantly when a multi-ton steam turbine crosses critical design velocity parameters, saving rotating machinery from catastrophic blade destruction.\u003c\/p\u003e\n\u003ch3\u003eDual SMB Coaxial Outputs Simplify Diagnostic Data Extraction\u003c\/h3\u003e\n\u003cp\u003eThe front face of the Revision 12 card features dedicated SMB coaxial ports that present buffered, unaltered raw pulse waveforms to external technicians. Vibration specialists clip portable oscilloscope clamps or dynamic signal analyzers directly onto these front ports without unseating field wires, removing terminal jumpers, or risking short-circuit trips. This accessible test architecture allows crews to evaluate physical probe gapping and trigger conditions while the target turbine runs live production streams.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Sensor Line Supervision Restricts False System Trips\u003c\/h3\u003e\n\u003cp\u003eAn advanced diagnostic engine tracks the electrical status of the field cable networks and sensor power rails continuously. The card identifies broken wires, shorted probe loops, and sensor power deterioration immediately, isolating field problems from physical machine faults. By declaring a diagnostic sensor fault instead of mimicking an overspeed state, the module prevents expensive false process trips while giving instrument techs exact maintenance guidance to shorten troubleshooting intervals.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan the A6312\/06 process inputs from two different sensor families at the same time? Yes. The module allows you to configure its two input channels independently via the system utility software. You can connect a negative-voltage eddy current proximity probe to Channel 1 to serve as the master phase reference (Keyphasor) while linking an active inductive magnetic pickup to Channel 2 to monitor continuous machine shaft RPM, maximizing rack utility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module handle order tracking during variable speed machine startups? The A6312\/06 translates the incoming shaft pulse into a high-accuracy phase reference vector that matches exact shaft position angles. It broadcasts this synchronization clock along the AMS 6500 backplane bus, allowing adjacent vibration cards to sample structural casing data at precise fractions of a rotation. This synchronization enables engineers to isolate specific vibration harmonics (1X, 2X, etc.) as the machine slews from standstill to functional runtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes installing a replacement A6312\/06 require a complete power-down of the AMS 6500 rack? No. The card features complete hot-swap integration compatibility within the AMS 6500 chassis layout. Staggered connector tracking grounds the card frame and synchronizes the logic interface before raw panel lines mate with the active backplane pins. This design allows technicians to hot-swap a damaged speed card without dropping power to adjacent, live machine protection loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42870829416538,"sku":"A6312\/06","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/141_669be373-36da-4a5f-af0d-8cdf5d3d0201.jpg?v=1772592321"},{"product_id":"140734-08-bently-nevada-3500-72m-position-monitor-new-stock","title":"140734-08 Bently Nevada 3500\/72M Position Monitor | New Stock","description":"\u003ch2\u003eBently Nevada 3500\/72M 140734-08 Position Monitor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 140734-08\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3500\/72M\u003c\/strong\u003e Position Monitor, operates as a dedicated hardware component for continuous static and dynamic position tracking within the 3500 Machinery Protection System. Configured to interface with field-mounted proximity transducers, the module provides direct physical\/electrical execution to compute rod drop, rod position, and piston location parameters across four independent channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/72M (Part Number: 140734-08)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C (-22 to +149 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.7 Watts (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Support\u003c\/td\u003e\n\u003ctd\u003eProximity Transducers (Proximitors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eStatic (DC) and dynamic position measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+-1% of full-scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Isolation\u003c\/td\u003e\n\u003ctd\u003e500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C (-40 to +185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMachinery Monitoring \u0026amp; Eddy-Current Probe Calibration\u003c\/h3\u003e\n\u003cp\u003eThe monitoring hardware relies on incoming analog telemetry from proximity transducers to determine real-time mechanical alignment. Proper data acquisition requires precise eddy-current probe scaling configurations within the software interface to match the physical properties of the installed tip diameter and target material. Field verification steps require a gap voltage validation targeting a nominal -10 VDC baseline, centering the proximity probe within its linear conversion zone. This tight electrical calibration optimizes internal cross-talk suppression, ensuring the module can isolate micro-strains in rod dynamics from background industrial noise.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 140734-08 module capture transient data during a machine trip event?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module integrates with the 3500\/22M Transient Data Interface (TDI). When a transient event or alarm occurs, the module streams high-resolution dynamic waveforms across the rack backplane for complete mechanical diagnosis inside System 1 software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What function does the 500 Vrms internal isolation serve on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 500 Vrms electrical isolation barrier uncouples the internal rack logic and backplane communication paths from external field wiring loops. This protection prevents common-mode voltage surges or field ground loops from disrupting adjacent monitoring channels inside the 3500 chassis.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Guide Alignment\u003c\/strong\u003e: Align the module with the front-plane card guides of the 3500 rack. Slide the hardware inward until the edge connectors mate completely with the passive backplane. Secure the card by fully tightening the two captive panel screws to establish frame ground connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Cable Shielding\u003c\/strong\u003e: Terminate the outer shields of all proximity transducer extension cables at the designated instrumentation ground rail within the marshalling cubicle. Do not earth the shield at both ends, as circulating currents will induce noise errors in the DC position measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximitor Tuning\u003c\/strong\u003e: Prior to locking down the transducer mounting assembly, use a digital multimeter to measure the raw gap voltage. Adjust the physical position of the probe until the reading hits the specific target calibration point, normally -10 VDC for standard non-ferrous configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Isolation Separation\u003c\/strong\u003e: Enclose all proximity sensor field cabling in dedicated low-voltage wireways. Maintain appropriate clearance between these measurement lines and heavy alternating current (AC) power lines or variable frequency drive cables to eliminate high-frequency inductive coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870829809754,"sku":"3500\/72M 140734-08","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/52_25db9e6d-5c57-4a40-b392-68a70f9e33a8.jpg?v=1772423690"},{"product_id":"3500-65-184469-01-bently-nevada-16-channel-rtd-tc-temperature-monitor","title":"3500\/65 184469-01 | Bently Nevada 16-Channel RTD\/TC Temperature Monitor","description":"\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/65 184469-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel temperature monitoring module engineered for industrial machinery protection. It accepts both RTD and isolated tip thermocouple (TC) inputs and supports triple modular redundancy (TMR) for high-reliability operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/65 184469-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16-Channel Temperature Monitor Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 RTD\/TC input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e100Ω platinum (α=0.00385): -200°C to +850°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100Ω platinum (α=0.00392): -200°C to +700°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e120Ω nickel: -80°C to +260°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10Ω copper: -100°C to +260°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoftware-configurable setpoints and delay timers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs (OK, TX\/RX, Bypass)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTMR Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriple Modular Redundant operation for critical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRack-mounted in 3500 Series system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Sensor Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts multiple RTD and TC types for flexible deployment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTMR configuration reduces single-point failures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Alarms:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoftware-managed thresholds for early fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUser Feedback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs provide operational status at a glance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to endure harsh operating environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eUsed widely in process monitoring, machinery protection, power generation, oil and gas, and chemical processing facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat types of sensors can be used with this module?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/65 184469-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports 100Ω platinum, 120Ω nickel, and 10Ω copper RTDs, as well as isolated tip thermocouples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module be integrated with TMR configurations?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it supports Triple Modular Redundancy for increased reliability in critical systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870829908058,"sku":"3500\/65 184469-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/350022M288055-01_17dbae33-a450-4f3a-9bb2-e70d13e57a86.jpg?v=1770106328"},{"product_id":"3500-64m-140734-05-bently-nevada-dynamic-pressure-monitoring-module-副本-1","title":"Bently Nevada | 3500\/65 145988-02 | Multi-Channel Temperature Monitoring Module","description":"\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/65 145988-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel temperature monitoring module designed for high-precision measurement of industrial equipment using both RTD and thermocouple inputs. It supports wide temperature ranges and real-time data communication via Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/65 145988-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTemperature Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBrand new, in stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 mm × 100 mm × 100 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRTDs and Thermocouples (TCs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRTD Input Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-200°C to 800°C (-328°F to 1472°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermocouple Input Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-200°C to 1800°C (-328°F to 3272°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.1% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.01°C (0.02°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable for full-scale range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet 10BASE-T\/100BASE-TX\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Channel Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports 16 simultaneous temperature points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccommodates both low- and high-temperature RTDs and TCs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Accuracy and Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintains ±0.1% full-scale accuracy with 0.01°C resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable alarms for critical process monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet connectivity enables rapid integration with control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEfficient 100 mm³ form factor suitable for 3500 Series racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIdeal for monitoring temperatures in turbines, compressors, pumps, and other critical industrial machinery in oil, gas, and power plants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module support only RTDs or TCs?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/65 145988-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaccepts both RTDs and thermocouples, providing flexibility for multiple applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs Ethernet required for operation?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet is used for communication and system integration, while the module can still operate locally.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870830137434,"sku":"3500\/65 145988-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/149986-01_a993960c-b5b9-4712-aad6-84c96237ead2.jpg?v=1770106336"},{"product_id":"3500-64m-140734-05-bently-nevada-dynamic-pressure-monitoring-module","title":"3500\/64M 140734-05 | Bently Nevada Dynamic Pressure Monitoring Module","description":"\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/64M 140734-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is a four-channel dynamic pressure monitoring unit designed for precise measurement and control of high-temperature industrial machinery. It integrates seamlessly with the 3500 Series monitoring system and other compatible setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (GE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/64M 140734-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDynamic Pressure Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 independent input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-temperature pressure transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBandpass dynamic pressure signal per channel, recorder outputs for system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable thresholds per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront panel LEDs including OK, TX\/RX, and Bypass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRack-mounted form factor (standard 3500 Series module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 0.8–1.0 kg (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne-year manufacturer warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Channel Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports four simultaneous dynamic pressure measurements for real-time analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Temperature Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts signals from elevated temperature pressure transducers without signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Alarms:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUser-defined alarm setpoints allow precise monitoring of operational limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides analog output for control system integration and data logging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront panel LEDs allow immediate status checks for module operation, communication, and bypass conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with 3500 Series racks and other supported monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eIdeal for monitoring dynamic pressures in turbines, compressors, and other high-temperature machinery in oil, gas, and power industries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module monitor more than four channels?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/64M 140734-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports four independent channels. For additional points, use multiple modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs it compatible with older 3500 Series racks?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it integrates with 3500 Series monitoring systems and selected compatible modules.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870830202970,"sku":"3500\/64M 140734-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/143488-011_66bf0fa1-d466-4efc-8f9e-6c2c82738420.jpg?v=1770106338"},{"product_id":"bently-nevada-3500-60-133811-01-temperature-monitoring-module","title":"Bently Nevada 3500\/60 133811-01 Temperature Monitoring Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60 133811-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Bently Nevada is a precision temperature monitoring module designed for integration within 3500 series racks. It provides accurate temperature measurement across six channels using RTDs or thermocouples, with outputs for alarm signaling and temperature conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/60\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133811-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTemperature Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Types:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRTDs, Thermocouples (TCs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlarm signals, temperature conversion signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh precision temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with 3500 series racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 1.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e150 × 100 × 60 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both RTD and thermocouple inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGenerates precise alarm signals for temperature excursions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design suitable for standard 3500 series control racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEngineered for reliable long-term performance in industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60 133811-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for monitoring critical machinery and processes in manufacturing, energy, and process control sectors where precise temperature measurement and alarm functionality are essential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: Is this unit new and genuine?\u003cbr\u003eA: Yes, all modules are factory-new and original Bently Nevada products.\u003c\/p\u003e\n\u003cp\u003eQ: How is this module mounted?\u003cbr\u003eA: It mounts directly into a standard 3500 series rack for seamless integration.\u003c\/p\u003e\n\u003cp\u003eQ: What input types are supported?\u003cbr\u003eA: Both RTDs and thermocouples are fully supported across six channels.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870831775834,"sku":"3500\/60 133811-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/350053133388-01__5.jpg?v=1770106374"},{"product_id":"140072-04-bently-nevada-position-monitor-module-new-original-stock","title":"140072-04 Bently Nevada Position Monitor Module | New \u0026 Original Stock","description":"\u003ch1\u003eBently Nevada 140072-04 3500\/45 Position Monitor Module\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 140072-04\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3500\/45\u003c\/strong\u003e Position Display \/ Monitor Module, operates as a dedicated hardware component for high-precision shaft position data acquisition within 3500 Series Machinery Protection System platforms. Configured to monitor axial thrust and differential expansion, the hardware accepts inputs from Proximity Transducer systems to track mechanical clearances. It provides 4-20 mA analog continuous outputs alongside discrete digital programmable relays to execute autonomous machine-level interlocks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e140072-04 (3500\/45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStandard 3500 single-slot monitor weight configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard 3500 rack single-slot module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e85 to 265 VAC (Universal Input), 47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInput Channels\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e4 independent physical channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eProximity Transducer Signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e4-20 mA analog loops and programmable digital relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eData Conversion\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e24-bit A\/D conversion resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eSystem Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e+\/-1% of full-scale range (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e10% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 140072-04 demands precise eddy-current probe scaling to convert analog electrical transitions into physical engineering units. The internal processing firmware performs real-time gap voltage validation against standard -10 VDC targets to ensure the proximity sensors remain biased within their linear calibration range. This validation prevents false trips or missed events during rapid changes in rotor dynamics. Onboard cross-talk suppression circuitry minimizes capacitive and inductive noise injection between adjacent transducer lines routed through the same physical conduit.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 140072-04 module be hot-swapped within the 3500 system rack without removing system power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 3500\/45 module architecture supports hot-swapping under power. However, the associated bypass switches on the rack must be engaged prior to removal to avoid initiating accidental downstream relay logic or emergency machinery trips.\u003c\/p\u003e\n\u003cp\u003eQ: What physical indicators represent a transducer circuit failure versus an internal module fault?\u003c\/p\u003e\n\u003cp\u003eA: The module front panel incorporates dedicated OK\/NOT OK status LEDs for each channel. An individual channel LED extinguishing indicates a transducer fault, line open, or out-of-bounds gap voltage validation, while a system failure causes the module main OK LED to transition state.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 4-20 mA analog loop output isolated from the internal rack backplane power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 4-20 mA analog outputs feature galvanic isolation from the internal backplane logic supply, preventing field ground loops from degrading the 24-bit A\/D conversion accuracy of the primary transducer signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Alignment:\u003c\/strong\u003e Insert the module into the designated slot of the standard 3500 chassis frame, ensuring the rear card edge alignment rails mate perfectly with the backplane connectors before tightening the front panel thumbscrews.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Shielding:\u003c\/strong\u003e Terminate the outer shields of all proximity probe cables at the chassis earth ground bus terminal only. Maintain shield continuity through any intermediate junction boxes without connecting the shield to the local machine case.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Wiring:\u003c\/strong\u003e Route the 4-20 mA analog output and digital relay wiring through separate, dedicated conduits isolated from high-voltage motor control circuits and high-current power distribution paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Engagement:\u003c\/strong\u003e Where external connections enter terminal housings, maintain strict adherence to industrial standards, utilizing exactly 5 threads of engagement for NPT conduit connections to secure the environmental seal rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870839279706,"sku":"3500\/45 140072-04","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/94_efb04a18-0d66-413c-ba47-f925ef38ffc2.jpg?v=1770954431"},{"product_id":"140072-02-bently-nevada-3500-45-position-monitoring-module","title":"140072-02 | Bently Nevada | 3500\/45 Position Monitoring Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140072-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3500\/45 is a precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePosition I\/O Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for interfacing with proximity transducers to monitor shaft position and vibration in critical machinery. Designed for the 3500 Series rack, this module ensures accurate, real-time data collection and reliable performance in industrial environments. Its internal terminations simplify installation and reduce wiring complexity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Shaft Monitoring\u003c\/strong\u003e: Captures precise shaft position and vibration signals for machinery protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Terminations\u003c\/strong\u003e: Streamlines wiring and reduces setup time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless System Integration\u003c\/strong\u003e: Compatible with other Bently Nevada 3500 Series modules for comprehensive machine monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Rack-Mount Design\u003c\/strong\u003e: Slim profile fits efficiently in standard 3500 rack slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Durability\u003c\/strong\u003e: Built to operate continuously in harsh conditions with high reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Availability\u003c\/strong\u003e: In-stock for immediate global shipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/45 140072-02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140072-02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Position I\/O Module with Internal Terminations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Bently Nevada 3500 Series rack modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Interface\u003c\/strong\u003e: Proximity transducers for shaft position and vibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 241.3 mm × 24.4 mm × 99.1 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.44 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e: One-year manufacturer warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShaft position monitoring in rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration tracking for turbines, compressors, and pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into Bently Nevada 3500 Series machinery protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse in industrial settings requiring continuous monitoring and reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140072-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ework with other 3500 Series modules?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it is fully compatible with all Bently Nevada 3500 Series rack modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs the module suitable for harsh industrial environments?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it is designed for continuous operation in challenging industrial conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat sensors are supported?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports proximity transducers for accurate shaft position and vibration measurement.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870839509082,"sku":"3500\/45 140072-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/143488-011_e56a72cc-f015-413c-b224-405906b1718e.jpg?v=1770106440"},{"product_id":"176449-02-bently-nevada-3500-42m-seismic-monitoring-module","title":"176449-02 | Bently Nevada | 3500\/42M Seismic Monitoring Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3500\/42M is a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProximitor\/Seismic Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to safeguard critical rotating machinery. It receives input from proximity and seismic transducers, providing continuous measurement of vibration and displacement. With internal terminations and configurable inputs, this module delivers reliable condition monitoring, early fault detection, and robust integration with Bently Nevada 3500 systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFour-channel input supporting proximity and seismic sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal conditioning for accurate vibration and position readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser-programmable alarms for anomaly detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVersatile monitoring for radial vibration, thrust position, and more\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal terminations simplify setup and wiring flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade protection for harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42M\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Bently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Proximitor\/Seismic Monitor Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e: Velocity, acceleration, displacement, proximity, or speed sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e: 4–20 mA, 0–10 V, 10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.5–0.6% depending on sensor type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e: Up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Options\u003c\/strong\u003e: 4–20 mA, RS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e: IP66\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: Status, communication, and alarm signaling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRotating Machinery Protection\u003c\/strong\u003e: Continuously monitors turbines, pumps, and compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration and Position Analysis\u003c\/strong\u003e: Detects abnormal machinery behavior for predictive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: Compatible with Bently Nevada 3500 rack modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Monitoring\u003c\/strong\u003e: Supports multiple vibration and displacement functions including thrust and radial measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many input channels does\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour independent channels for proximity and seismic signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module trigger alarms based on signal thresholds?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, alarms are fully programmable for vibration or displacement conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs it suitable for harsh environments?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the module features IP66 protection and operates from -40°C to +85°C.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870839935066,"sku":"3500\/45 135137-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/350045135137-01.jpg?v=1770106443"},{"product_id":"bently-nevada-3500-42m-proximitor-seismic-monitor-176449-02","title":"Bently Nevada 3500\/42M Proximitor Seismic Monitor | 176449-02","description":"\u003ch3 class=\"\"\u003eBently Nevada 3500\/42M Proximitor Seismic Monitor | 176449-02\u003c\/h3\u003e\n\u003ch3 class=\"\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e3500\/42M (176449-02)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated four-channel machinery protection monitor designed for the Bently Nevada 3500 rack system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt provides continuous surveillance by processing inputs from Proximitor and seismic transducers to evaluate parameters such as radial vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethrust position,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand eccentric motion.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy comparing real-time data against user-defined setpoints,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e176449-02\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensures immediate alarm triggering and machinery protection to prevent catastrophic failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Signals\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProximity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAcceleration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVelocity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Seismic transducers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChannel Density\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 channels per module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Conditioning\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInternal high-precision integration and filtering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eA\/D Conversion\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24-bit Sigma-Delta\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAccuracy\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e±0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5% of full-scale range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFrequency Response\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Hz to 30 kHz (application dependent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSampling Rate\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed digital signal processing up to 10 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Interface\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA proportional outputs and buffered transducer signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProprietary backplane interface and RS-485 via I\/O modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eI\/O Termination\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInternal terminations for simplified field wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eAdvanced Monitoring Functions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e3500\/42M (176449-02)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupports diverse monitoring configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding Shaft Relative Vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAxial Position,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Differential Expansion.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt utilizes advanced filtering algorithms to eliminate signal noise,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that only valid mechanical anomalies trigger the alarm logic.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is critical for steam turbines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecentrifugal compressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand large induction motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eHow does the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e176449-02\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ehandle transducer power?\u003c\/span\u003e\u003cspan class=\"\"\u003eThe module provides regulated power directly to the transducers via the I\/O module,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeliminating the need for external power supplies for standard proximity probes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eCan this monitor be used for SIL applications?\u003c\/span\u003e\u003cspan class=\"\"\u003eYes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe Bently Nevada 3500 series,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e3500\/42M\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis typically certified for use in functional safety systems up to SIL 2 levels.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870840393818,"sku":"3500\/42M 176449-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/143488-012_905aa7b4-9d2e-4a4a-a231-7995b9d71a6f.jpg?v=1770106445"},{"product_id":"bently-nevada-140734-02-industrial-proximitor-seismic-monitor","title":"Bently Nevada 140734-02 Industrial Proximitor Seismic Monitor","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140734-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3500\/42M is a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProximitor Seismic Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for continuous protection of critical rotating machinery. It provides four independent channels to monitor vibration and proximity signals, ensuring accurate assessment of machinery condition and early detection of potential faults. This rugged module is engineered for industrial environments, supporting long-term reliability and integration with the 3500 monitoring system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFour-channel input for simultaneous monitoring of proximity and seismic transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel LED indicators for operational status, communication, and bypass mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuffered transducer outputs with short-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecorder outputs with high-resolution voltage compliance for accurate data acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRapid update rate (~100 ms) for timely monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and robust design suitable for harsh industrial conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140734-02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Bently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Proximitor Seismic Monitor Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: 10 kΩ for proximitor and accelerometer channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 7.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Transducer Outputs\u003c\/strong\u003e: Coaxial connectors, 550 Ω output impedance, -24 V DC transducer power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e: Voltage 0–12 V DC, 0.3662 V per bit resolution, ≤0.25% error at 25°C, ≤0.7% over full temperature range, 300 Ω impedance, short-circuit protected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e: ~100 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e: Industrial-grade, compatible with 3500 system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: OK, TX\/RX communication, Bypass status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRotating Machinery Protection\u003c\/strong\u003e: Monitors turbines, compressors, and pumps for early fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Analysis\u003c\/strong\u003e: Measures displacement and vibration signals from Proximitor and seismic sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePredictive Maintenance\u003c\/strong\u003e: Provides high-resolution monitoring data for proactive maintenance planning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: Works seamlessly with Bently Nevada 3500 rack modules for comprehensive machinery monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many channels does the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140734-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitor simultaneously?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour independent channels for proximity and seismic inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAre the outputs protected against short circuits?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, both buffered transducer outputs and recorder outputs have built-in short-circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs this module compatible with the 3500\/42M system?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible and designed to integrate with the 3500 monitoring rack.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870840819802,"sku":"3500\/42M 140734-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/143488-01_d9e1b537-f9f5-4ff7-8ae2-3d88d58b84d5.jpg?v=1770106448"},{"product_id":"3500-42-125972-02-bently-nevada-proximity-seismic-monitor","title":"3500\/42 | 125972-02 | Bently Nevada | Proximity\/Seismic Monitor","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42 125972-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Bently Nevada is a precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eproximity and seismic monitor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for continuous machinery condition monitoring. It accurately measures vibration and displacement to detect early signs of potential issues, enabling proactive maintenance and reducing equipment downtime.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual compatibility with proximity sensors and seismic transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-accuracy measurement for vibration and displacement monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide frequency response for capturing both low and high-speed machinery events\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput signals standardized at 0–10 VDC for seamless integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports predictive and preventive maintenance strategies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42 125972-02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Bently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Proximity\/Seismic Monitor Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProximity Sensor\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Range: 0.025–0.500 inches (0.64–12.7 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Response: DC–20 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal: 0–10 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeismic Sensor\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 10 mV\/g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Response: 10 Hz–10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal: 0–10 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: Turbines, pumps, compressors, and other rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Rack or panel compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e: Integrated for accurate and stable readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUsed in industrial facilities to monitor rotating machinery health, enabling timely interventions and reducing the risk of unexpected failures. Suitable for energy, manufacturing, and process industries.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes this module work with both proximitor and seismic sensors?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it supports both sensor types for flexible installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the measurement range for proximity sensors?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.025–0.500 inches (0.64–12.7 mm).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan this module detect high-frequency vibrations?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the module supports up to 20 kHz for proximity and 10 kHz for seismic inputs.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870843834458,"sku":"3500\/42 125972-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/143488-01_70dbfecd-75a9-4556-94ae-8cdad726e4d0.jpg?v=1770106462"},{"product_id":"bently-nevada-3500-series-3500-40m-01-05-advanced-proximitor-monitor","title":"Bently Nevada 3500 Series 3500\/40M-01-05 Advanced Proximitor Monitor","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/40M-01-05 Proximitor Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to deliver accurate, reliable vibration and position measurements for critical machinery. It integrates seamlessly with the 3500 Series rack system, providing robust monitoring capabilities across multiple channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFour independent channels for simultaneous vibration and position monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccepts standard proximity transducer inputs and extension cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutputs include 4–20 mA proportional signals and buffered transducer outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics with self-check and fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable alarm thresholds for proactive machinery protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade reliability for continuous operation under harsh conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimple installation within the 3500 Series rack, no external power required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 3500\/40M-01-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Proximitor Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: 4 independent channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput\u003c\/strong\u003e: Proximity transducers, extension cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e: 4–20 mA proportional signals, buffered transducer outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: Fully compatible with 3500 Series rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: Powered through the 3500 rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –30°C to +65°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 241 mm × 24.4 mm × 99 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: ~0.45 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring shaft vibration and rotor position in turbines, compressors, and generators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFault detection and preventive maintenance in high-speed rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with other 3500 Series modules for complete machinery protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many channels does this module support?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports four independent monitoring channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs external power needed for operation?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the module is powered directly via the 3500 Series rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat type of outputs does the monitor provide?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt provides 4–20 mA proportional signals and buffered transducer outputs.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870856417370,"sku":"3500\/40M-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/143488-01_496edbec-37ce-4a4f-b5bb-284f53d4a210.jpg?v=1770106532"},{"product_id":"bently-nevada-3500-series-3500-40-02-01-proximitor-monitor-i-o-module","title":"Bently Nevada 3500 Series 3500\/40-02-01 Proximitor Monitor I\/O Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/40-02-01 Proximitor I\/O Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel interface designed to connect proximity probes to the 3500 monitoring system. It conditions vibration and position signals for accurate analysis, providing engineers with reliable data for machinery protection and operational monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual-channel input for independent proximity probe signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced signal conditioning for precise vibration and axial position measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design for seamless rear-rack installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal termination simplifies wiring and installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable for rapid replacement without system downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 3500\/40 Proximitor Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 3500\/40-02-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Proximitor I\/O Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Support\u003c\/strong\u003e: Dual-channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e: Vibration and axial position\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e: Rear rack, paired with 3500\/40 monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 241 mm × 24.4 mm × 99.1 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: ~0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –30°C to +65°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e: 0%–95%, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e: IP65 (industrial grade)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShaft vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAxial and thrust position measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDifferential expansion tracking in rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for turbines, compressors, generators, and pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many channels does this module support?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports dual-channel inputs for independent probe signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan it be replaced without shutting down the system?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the module is hot-swappable for quick maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs it compatible with all Bently Nevada 3500 monitors?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed specifically for the 3500\/40 Proximitor Monitor.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870857105498,"sku":"3500\/40-02-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/143488-01_24a7b6d1-3f87-4c8d-9739-a096923289fb.jpg?v=1770106536"},{"product_id":"emerson-ams-6500-a6140-phase-reference-monitoring-card","title":"Emerson AMS 6500 A6140 Phase Reference Monitoring Card","description":"\u003ch3\u003e\u003cstrong\u003eShopify Product Title\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEmerson AMS 6500 A6140 Shaft Runout and Phase Reference Monitoring Card\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eMachinery Health Integrity Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6140\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Model:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6140\u003c\/strong\u003e) is a specialized dual-channel monitoring module engineered for the Emerson AMS 6500 Machinery Health Monitoring System. It is designed to provide high-precision measurements of shaft eccentricity (runout) while simultaneously generating a stable phase reference signal required for synchronous vibration analysis. By interfacing directly with eddy-current proximity probes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6140\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6140\u003c\/strong\u003e) enables the early detection of mechanical anomalies such as bent shafts, thermal bowing, misalignment, or internal rubs. This card is a critical component for the protection of high-speed rotating assets, including steam and gas turbines, centrifugal compressors, and large-scale industrial pumps.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6140 (A6140)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the following industrial-grade technical parameters for continuous condition monitoring:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson (formerly EPRO\/Philips)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6140\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring Channels\u003c\/strong\u003e: 2 Independent Channels (Configurable for Eccentricity or Phase)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: AMS 6500 Machinery Health Monitor (3U Rack)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e: Eddy-current proximity probes (PR6422, PR6423, PR6424, PR6425)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Drivers\u003c\/strong\u003e: Compatible with CON 011\/021\/041 series drivers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: ±2 mm to ±5 mm (Hardware\/Probe dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Frequency Response\u003c\/strong\u003e: DC to 1 kHz (for displacement data)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e: ±0.25% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Resolution\u003c\/strong\u003e: 0.001 mm (1 micron)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Reference Output\u003c\/strong\u003e: TTL\/Logic compatible signal for tachometer synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Interface\u003c\/strong\u003e: 0\/4–20 mA proportional DC outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Dynamic Outputs\u003c\/strong\u003e: Front-panel BNC and rear-terminal buffered raw signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Protection\u003c\/strong\u003e: Channel-to-channel and channel-to-backplane galvanic isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: +24 V DC nominal (via AMS 6500 backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 6 W Typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e: –40°C to +70°C operating range; 5–95% non-condensing humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Format\u003c\/strong\u003e: 3U Eurocard plug-in module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.85 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42870895378522,"sku":"A6140","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/135_210ffcfb-d9b5-4716-8bd3-4c5270ddec15.jpg?v=1772589908"},{"product_id":"a6125-emerson-ams-6500-machinery-health-thrust-monitor","title":"A6125 Emerson AMS 6500 Machinery Health Thrust Monitor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6125 (Model: A6125)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision dual-channel thrust position monitoring module specifically engineered for the Emerson AMS 6500 Machinery Health Monitoring System. This module is designed to provide real-time axial shaft displacement data, serving as a critical layer of protection for high-speed rotating assets such as steam turbines, gas compressors, and large industrial pumps.\u003c\/p\u003e\n\u003cp\u003eBy utilizing eddy-current proximity probes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6125 (Part Number: A6125)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitors the gap between the probe and the shaft shoulder or thrust collar. This continuous tracking enables early detection of thrust bearing wear, misalignment, and potential mechanical failure, ensuring compliance with API 670 standards for machinery protection. Its 3U plug-in architecture allows for seamless integration into AMS 6500 rack environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6125\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides deterministic monitoring and signal conditioning for critical thrust parameters.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson Automation Solutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6125\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e: AMS 6500 Machinery Health Monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e: 2 Independent Thrust Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e: Eddy-current proximity probes (PR6422, PR6423, PR6424, PR6425) via CON 0xx drivers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Configurable from ±2 mm to ±5 mm (Probe dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Accuracy\u003c\/strong\u003e: ±0.25% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Resolution\u003c\/strong\u003e: 0.001 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: DC to 1 kHz (Displacement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e: 0\/4–20 mA proportional outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Outputs\u003c\/strong\u003e: Buffered dynamic outputs available via front and rear connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Capabilities\u003c\/strong\u003e: Channel-to-channel and channel-to-backplane galvanic isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: API 670 Machinery Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Parameters\u003c\/strong\u003e: 24 VDC nominal; 6 W typical consumption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e: –40°C to +70°C Operating; –40°C to +85°C Storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Format\u003c\/strong\u003e: 3U plug-in module for AMS 6500 chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.95 kg (Average)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA6125 (Model: A6125)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically deployed in the following critical monitoring environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSteam and Gas Turbines\u003c\/strong\u003e: Monitoring axial rotor float to prevent catastrophic contact between rotating and stationary components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentrifugal Compressors\u003c\/strong\u003e: Early detection of thrust bearing degradation caused by surge conditions or axial load changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler Feed Pumps\u003c\/strong\u003e: Managing axial displacement in high-pressure fluid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRefining and Petrochemical\u003c\/strong\u003e: Continuous protection of large motors and gearboxes in 24\/7 production loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42870895607898,"sku":"A6125","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/108._7446df7b-dba8-4446-90b4-b768b1b2c823.jpg?v=1772072448"},{"product_id":"a6120-emerson-ams-6500-vibration-monitor-new-stock","title":"A6120 Emerson AMS 6500 Vibration Monitor | New Stock","description":"\u003ch1\u003eEmerson A6120 AMS 6500 Series Absolute Bearing Housing Monitor\u003c\/h1\u003e\n\u003cp\u003eConfigured for absolute vibration measurement on bearing housings and machine casings in AMS 6500 Machinery Health System racks, the \u003cstrong\u003eEmerson A6120\u003c\/strong\u003e (\u003cstrong\u003eA6120\u003c\/strong\u003e Dual-Channel Absolute Vibration Monitor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eA6120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEmerson Automation Solutions (EPRO Division)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1.0 kg maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard 3U plug-in module for AMS 6500 chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e8 W maximum via AMS 6500 backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInput Channels\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e2 independent isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eElectrodynamic velocity sensors and Piezoelectric accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eSignal Resolution\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e16-bit analog-to-digital conversion architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e10 Hz to 1 kHz (Velocity) \/ 10 Hz to 10 kHz (Acceleration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003ePlus or minus 0.25% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eSignal Outputs\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eDual 0\/4-20 mA proportional loops and isolated buffered dynamic outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates continuous channel-to-channel and channel-to-backplane galvanic isolation to suppress common-mode electrical noise in high-potentials industrial environments. Raw waveforms from connected accelerometers or moving-coil velocity transducers undergo internal signal conditioning to generate independent 0\/4-20 mA current outputs proportional to calibrated RMS, peak, or peak-to-peak parameters. Dedicated diagnostic circuitry provides buffered dynamic signal outputs alongside the primary current loop paths, isolating external analysis hardware from the underlying machinery protection backplane and protecting core loop telemetry from circuit disruptions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the A6120 module accommodate hot-swap extraction and insertion procedures within a live rack environment?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware is designed for insertion into an energized AMS 6500 rack chassis without affecting adjacent monitoring modules, provided the software bypass controls for associated protective relays are activated prior to card replacement.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module execute sensor validation and loop integrity checks?\u003c\/p\u003e\n\u003cp\u003eA: The A6120 features integrated OK-circuit logic that continuously monitors the bias voltage of the inputs. Any open circuit, short circuit, or sensor component failure automatically triggers a fault indicator and prevents false trip conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the 3U card into the assigned slot layout of the standard AMS 6500 chassis, tightening the front panel retaining fasteners to secure electrical contact.\u003c\/li\u003e\n\u003cli\u003eConnect field instrumentation using continuous twisted-shielded wiring bundles to mitigate ambient electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003eTerminate all braided cable shields exclusively at the designated cabinet instrumentation ground rail to preserve the channel isolation parameters.\u003c\/li\u003e\n\u003cli\u003eRoute the high-frequency accelerometer and velocity sensor input leads through isolated low-voltage wireways completely separated from plant power circuits.\u003c\/li\u003e\n\u003cli\u003eEnsure adjacent slot spacing allows unimpeded convective air flow to keep the module internal components within the -40 to +70 deg C operating threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EPRO","offers":[{"title":"Default Title","offer_id":42870895837274,"sku":"A6120","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/84_90d41ea4-8cc7-4999-9a07-d06288b76712.jpg?v=1770950379"},{"product_id":"a6110-emerson-ams-6500-vibration-monitoring-card-new-stock","title":"A6110 Emerson AMS 6500 Vibration Monitoring Card | New Stock","description":"\u003ch2\u003eEmerson A6110 AMS 6500 Series Vibration Monitoring Card\u003c\/h2\u003e\n\u003cp\u003eConfigured for shaft relative vibration monitoring in AMS 6500 Machinery Health System racks, the \u003cstrong\u003eEmerson A6110\u003c\/strong\u003e (\u003cstrong\u003eA6110\u003c\/strong\u003e Dual-Channel Vibration Monitoring Card) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eA6110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eEmerson Automation Solutions (EPRO Division)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e1-slot, 3U plug-in architecture for standard AMS 6500 chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e6 W typical (10 W maximum) via AMS 6500 backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eMonitoring Channels\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e2 independent channels (shaft relative vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eEddy-current proximity probes (PR6422, PR6423, PR6424, PR6425)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e0 to -22 VDC differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eGreater than 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e1500 VDC channel-to-channel \/ 2500 VDC channel-to-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003ePlus or minus 0.25% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates full channel-to-channel isolation measured at 1500 VDC to prevent earth ground loops from introducing signal errors into parallel monitoring pathways. Raw differential signals from eddy-current probes are processed internally to drive analog 0\/4-20 mA or 0-10 V outputs proportional to peak-to-peak shaft displacement, zero-to-peak amplitude, RMS levels, or Smax orbital calculations. While the standard analog outputs are mapped directly to external DCS parameters or plant indicators, the channel-to-backplane isolation barriers ensure that high-frequency electronic noise does not migrate from the field wiring terminals into the primary processing logic of the AMS 6500 chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the A6110 module accommodate live hot-swap insertion and removal within an operational rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The chassis backplane interface allows hot-swap card substitution without disrupting adjacent channels or powering down the entire machinery protection rack, provided the software bypass configurations are engaged first to prevent accidental trip execution.\u003c\/p\u003e\n\u003cp\u003eQ: How is the low-frequency boundary configured for specific rotor speed profiles?\u003c\/p\u003e\n\u003cp\u003eA: The internal firmware parameters allow for a user-selectable low-cut frequency limit set at either 1 Hz or 5 Hz, establishing proper calibration bounds based on the turning gear and baseline operational RPM profiles of the monitored machine train.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the 3U module carefully into its designated slot in the AMS 6500 rack chassis, ensuring the rear Eurocard connectors seat fully and the front retaining screws are torqued down.\u003c\/li\u003e\n\u003cli\u003eUse twisted-shielded instrumentation pairs for all proximity probe field connections to prevent external electromagnetic fields from inducing signal variations.\u003c\/li\u003e\n\u003cli\u003eTerminate all sensor cable braided shields at the designated instrumentation ground bar in the cabinet, maintaining single-point grounding rules to preserve galvanic isolation performance.\u003c\/li\u003e\n\u003cli\u003eRoute the analog 0\/4-20 mA telemetry lines through dedicated low-voltage wire trays separated from high-current AC motor control cables.\u003c\/li\u003e\n\u003cli\u003eEnsure that the environmental operating temperature surrounding the rack enclosure does not exceed the maximum rating of 70 deg C during peak summer loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EPRO","offers":[{"title":"Default Title","offer_id":42870896066650,"sku":"A6110","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/83.jpg?v=1770949996"},{"product_id":"brand-new-bently-nevada-3500-05-full-size-monitoring-rack","title":"Brand New Bently Nevada 3500\/05 Full-Size Monitoring Rack","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/05-01-01-05-00-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the central high-integrity framework for the 3500 Machinery Protection System. This 19-inch EIA standard rack houses and powers the essential modules required for continuous monitoring of critical rotating assets. It serves as the physical and electronic backbone for vibration, position, speed, and temperature acquisition. We supply this chassis in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original factory condition\u003c\/strong\u003e, ensuring compliance with the most stringent global safety and API 670 standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: 3500\/05-AA-BB-CC-DD-EE\u003c\/h3\u003e\n\u003cp\u003eThe dash code configuration defines the specific mounting and agency approval profile for this system:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01 (AA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19-inch Rack (14 monitor slots)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01 (BB)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05 (CC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Approvals (CSA, ATEX, CE, IECEx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00 (DD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReserved\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01 (EE)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEuropean Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/05 rack utilizes a passive backplane design to eliminate single points of failure in data communication.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlot Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 Monitor Slots + Power Supply \u0026amp; RIM Slots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-Grade Corrosion-Resistant Metal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully complies with API 670 standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 19-inch EIA Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Access\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Rear-Access for I\/O and Power connections\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +65 °C (-22 °F to +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C (-40 °F to +185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% non-condensing relative humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e266 mm x 482 mm x 349 mm (Standard 19\" Rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Maintenance Access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rear-access I\/O design separates field wiring from the sensitive front-facing modules. This configuration allows technicians to swap or upgrade monitor modules without disturbing field terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Power Infrastructure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe backplane supports dual-power supply modules. This redundancy ensures the machinery protection system remains active even if one primary power source fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion-Resistant Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConstructed from heavy-duty, industrial-grade metal, the 3500\/05 chassis resists the corrosive atmospheres typical of oil \u0026amp; gas refineries and chemical processing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInter-Module Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe passive digital backplane facilitates rapid data exchange between monitors and the Rack Interface Module (RIM), enabling sophisticated diagnostic functions and unified alarm triggering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the API 670 compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAPI 670 defines the industry standard for machinery protection systems. Compliance ensures the 3500\/05 rack meets specific requirements for reliability, response time, and hardware durability in critical asset protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many modules can this specific rack hold?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/05-01-01-05-00-01 is a full-size rack. It accommodates up to 14 monitor modules, in addition to dedicated slots for two power supplies and one Rack Interface Module (RIM).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I convert a Panel Mount rack to a Rack Mount version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the internal backplane remains similar, the physical mounting ears and hardware differ. We recommend purchasing the correct dash code (01 for Panel Mount) to ensure a secure fit within your control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this an authentic Bently Nevada product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We provide the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/05-01-01-05-00-01 in 100% Brand New condition\u003c\/strong\u003e, complete with original manufacturer packaging and technical documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870905339994,"sku":"3500\/05-01-01-05-00-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/372..jpg?v=1776669691"},{"product_id":"bently-nevada-1900-65a-167699-02-speed-vibration-monitor","title":"Bently Nevada 1900\/65A 167699-02 Speed\/Vibration Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003eHigh-Integrity Machinery Protection in a Compact Format\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1900\/65A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile and self-contained machinery protection system designed for continuous monitoring and protection of critical industrial assets. This specific kit comprises the monitor unit\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e167699-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand its associated components\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172323-01\u003c\/strong\u003e. Unlike large-scale rack systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1900\/65A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides essential protection for small to mid-sized machinery—such as cooling tower fans, pumps, and small compressors—where a full 3500 series rack may not be cost-effective. It effectively monitors vibration, position, and speed, ensuring equipment safety through immediate alarm and trip functionality.\u003c\/p\u003e\n\u003ch3\u003eFlexible Interface and Seamless Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1900\/65A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to bridge the gap between field sensors and plant-wide control systems. It accepts a variety of inputs, including proximity probes, accelerometers, and velocity sensors. For data integration, the module provides 4–20 mA proportional outputs for direct connection to a DCS or PLC, alongside Modbus RS-485 communication for digital integration. The module features configurable onboard relays, allowing for independent machinery shutdown logic that operates reliably even if the supervisory control system is offline.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1900\/65A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent P\/Ns\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e167699-02\u003c\/strong\u003e (Unit) \u0026amp; \u003cstrong\u003e172323-01\u003c\/strong\u003e (Components)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Monitor Channels + 1 Tachometer Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes, Accelerometers, Velocity Sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMonitoring Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRadial Vibration, Axial Position, Shaft Speed, Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple 4–20 mA Proportional Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Comms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RS-485 (via terminal block)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Config\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable Alarm and Trip Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 36 Vdc (24 Vdc nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–35 °C to +65 °C (–31 °F to +149 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.289 kg (Net)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870910615642,"sku":"1900\/65A (167699-02+172323-01)","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/19._eb9d42ae-ad85-4264-b4f6-41c3316e0a7f.jpg?v=1770280251"},{"product_id":"102351-04-01-bently-nevada-3300-xl-8mm-proximity-probe","title":"102351-04-01 Bently Nevada 3300 XL 8mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 102351-04-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the primary sensing element for the 3300 XL Proximity Transducer System. This 8mm eddy current probe provides non-contact displacement measurements, tracking shaft vibration and axial position in high-speed rotating equipment. It converts the physical gap between the probe tip and the target surface into a high-fidelity electrical signal. Built to withstand the harshest industrial conditions, the 102351-04-01 ensures precise monitoring of turbines, compressors, and motors where unplanned downtime results in significant financial loss.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 102351-04-01 follows a specific metric configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e102351:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 8mm Proximity Probe with M10 x 1 Metric Threads (Unthreaded length varies).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-04:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the Case Length (Typically 40mm for standard mounting depth).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSets the Integrated Cable Length to 1.0 Meter (3.3 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102351-04-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 × 1 (Metric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Meter (3.3 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAverage Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–35 °C to +180 °C (–31 °F to +356 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Voltage via Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, CSA, IEC Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced TipLock Technology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe probe features a hermetically sealed tip made from high-performance polyphenylene sulfide (PPS). This construction prevents the ingress of lubricating oils, water, and corrosive chemicals, ensuring the probe remains accurate throughout its entire lifecycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterchangeability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3300 XL system allows for full interchangeability between probes, extension cables, and Proximitor sensors of the same length without requiring individual calibration. This reduces spare parts inventory and simplifies field maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated shielding within the cable and probe body protects the signal from electromagnetic interference. This design prevents \"ghost\" vibration readings caused by nearby large motors or variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMetric Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe M10 x 1 metric thread allows for seamless integration into global machinery platforms (OEMs). The AISI 303 stainless steel housing resists mechanical stress and chemical erosion in high-heat environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGold-Plated Connections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Click-Lock coaxial connector uses gold plating to ensure low-resistance contact. This eliminates signal drift and prevents the intermittent failures often associated with oxidized silver or tin connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Can I use the 102351-04-01 with older 3300 (non-XL) systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the threads may match, the 3300 XL probe is specifically tuned for the 3300 XL Proximitor. Mixing XL and non-XL components may result in a non-linear scale factor. Always use a complete 3300 XL transducer chain (Probe, Cable, and Proximitor) for maximum accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How do I determine the correct gap during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallers typically use a digital voltmeter to measure the DC voltage output from the Proximitor. A reading of -10.0 VDC (at the center of the 2.0mm linear range) usually indicates the optimal physical gap between the probe tip and the shaft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Is this product 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the Bently Nevada 102351-04-01 as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal unit. It ships in the original factory box with a traceable serial number and a manufacturer's inspection report.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What happens if the probe integrated cable is too short?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1.0m integrated cable is designed to connect to a 3300 XL Extension Cable (typically 4m or 8m). Never splice the integrated cable; instead, select an extension cable that matches your total system length requirements (5m or 9m total).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42894988673114,"sku":"102351-04-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/54.jpg?v=1770369735"},{"product_id":"102550-01-bently-nevada-3300-xl-8mm-proximity-probe","title":"102550-01 Bently Nevada 3300 XL 8mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 102550-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision eddy current sensor designed for the 3300 XL Proximity Transducer System. This 8mm probe performs non-contact displacement measurements to track shaft vibration and axial position in high-speed rotating machinery. The sensor converts the physical distance between the probe tip and the target into a proportional electrical signal. Engineered for extreme durability, the 102550-01 withstands aggressive industrial fluids and high-pressure environments, serving as the frontline defensive component for turbine and compressor protection.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 102550-01 follows Bently Nevada’s metric hardware logic:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e102550:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRefers to the 3300 XL 8mm Proximity Probe with M10 x 1 metric threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the 1.0 Meter (3.3 feet) integrated cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102550-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 × 1 (Metric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Meter (3.3 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAverage Scale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–35 °C to +180 °C (–31 °F to +356 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully hermetically sealed tip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated Click-Lock coaxial connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Media Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hermetically sealed TipLock construction prevents the ingress of lubricating oils, high-pressure steam, and corrosive contaminants. This ensures measurement stability even when the probe resides inside a machine's oil sump or casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Metric Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe M10 x 1 metric threading simplifies installation in European and Asian manufactured machinery. It allows for direct mounting into existing threaded ports without the need for specialized adapters or re-tapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe polyphenylene sulfide (PPS) probe tip and stainless steel body effectively minimize the \"side-view\" effect. This focuses the magnetic field directly ahead of the tip, allowing for accurate measurements in tight mechanical clearances without interference from surrounding housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Strength:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 303 stainless steel body resists mechanical deformation during installation and operation. The integrated cable features a robust strain relief that prevents damage caused by vibration-induced fatigue at the probe-to-cable transition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGold-Plated Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Click-Lock coaxial connector utilizes gold-plated contacts. This eliminates oxidation-related signal drift and ensures a low-impedance connection to the extension cable over decades of service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Does the 102550-01 probe require a specific Proximitor sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must pair the 102550-01 with a 3300 XL Proximitor (typically a 5-meter or 9-meter system depending on your extension cable length). Using it with older 3300 or 7200 series Proximitors will result in incorrect scale factors and measurement errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Is this probe 100% Brand New or surplus stock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply the Bently Nevada 102550-01 as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment. Each unit ships in original factory packaging with a traceable serial number and manufacturer's quality certificate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can I install this probe in high-pressure environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 102550-01 features a hermetically sealed tip. It withstands pressures typically found in industrial gearboxes and bearing housings. If your application involves extreme vacuum or pressure, verify your casing seal requirements (e.g., using a probe housing with a pressure-rated seal).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What is the benefit of the 1.0m cable over the 0.5m version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1.0m integrated cable offers more flexibility for routing the signal out of the machine casing to a junction box. It reduces the need for the extension cable connector to reside in extremely tight or oily spaces, facilitating easier maintenance and inspection.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42895012528218,"sku":"102550-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/55.jpg?v=1770370320"},{"product_id":"armored-sensor-probe-cablebently-nevada-16710-12","title":"Armored Sensor Probe CableBently Nevada 16710-12","description":"\u003ch2\u003eBently Nevada 16710-12 Armored Interconnect Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-fidelity signal transmission in mechanical condition monitoring systems, the \u003cstrong\u003eBently Nevada 16710-12\u003c\/strong\u003e (\u003cstrong\u003e16710-12\u003c\/strong\u003e Interconnect Cable) provides direct electrical connection between proximity sensors and monitoring instrumentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16710-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 - 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.6 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3-Conductor Shielded Armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003e22 AWG Tinned Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProximity Probe Scaling and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e16710-12\u003c\/strong\u003e cable acts as the transmission medium for transducer signals, which necessitates strict adherence to impedance matching requirements. Bently Nevada engineers specify these cables to ensure consistent eddy-current probe scaling, preventing signal attenuation that would otherwise compromise dynamic measurements. The stainless steel armor provides mechanical protection, while the internal shielding facilitates cross-talk suppression between adjacent sensor runs. Technicians must verify the total loop length during installation to prevent signal degradation in long-distance applications, as excessive cable capacitance directly impacts the frequency response of the rotor dynamics data.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the cable shield require grounding at both ends?\u003c\/p\u003e\n\u003cp\u003eA: You must maintain a single-point ground for the cable shield at the monitoring system interface. Connecting the shield at both ends creates ground loops, which introduce 50\/60 Hz interference into the vibration signal.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable be used for high-temperature turbine applications?\u003c\/p\u003e\n\u003cp\u003eA: While the cable supports operation up to +85 deg C, you must utilize high-temperature extension cables for zones exceeding this threshold. You should verify the ambient temperature at the probe connection point before final cable routing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting:\u003c\/strong\u003e Avoid bending the cable tighter than the manufacturer-specified minimum radius. Sharp bends stress the internal conductors and degrade the shielding effectiveness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Ensure the coaxial connectors are clean and free of debris. Tighten the connector to the specified torque to prevent intermittent electrical contact during machine operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Route the cable through protective conduit in areas prone to mechanical impact. The interlocking stainless steel armor provides physical strength, but it does not replace the requirement for conduit in harsh process zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e Perform a continuity check and inspect for shorts between the conductors and the shield before system commissioning. Ensure the loop resistance matches the value expected for a 12-foot cable run to confirm internal integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057272717402,"sku":"16710-12","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/253.1.jpg?v=1773623519"},{"product_id":"bently-nevada-16710-15-armored-sensor-probe-cable","title":"Bently Nevada 16710-15 Armored Sensor Probe Cable","description":"\u003ch2\u003eBently Nevada 16710-15 Armored Sensor Probe Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-fidelity signal transmission in mechanical condition monitoring systems, the \u003cstrong\u003eBently Nevada 16710-15\u003c\/strong\u003e (\u003cstrong\u003e16710-15\u003c\/strong\u003e Interconnect Cable) provides direct electrical connection between proximity sensors and monitoring instrumentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16710-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.131 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.57 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eN\/A (Passive Component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored Interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProximity Probe Scaling and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e16710-15\u003c\/strong\u003e cable acts as the transmission medium for transducer signals, which necessitates strict adherence to impedance matching requirements. Bently Nevada engineers specify these cables to ensure consistent eddy-current probe scaling, preventing signal attenuation that would otherwise compromise dynamic measurements. The integrated metallic armor provides mechanical protection, while the internal shielding facilitates cross-talk suppression between adjacent sensor runs. Technicians must verify the total loop length during installation to prevent signal degradation in long-distance applications, as excessive cable capacitance directly impacts the frequency response of the rotor dynamics data.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the cable shield require grounding at both ends?\u003c\/p\u003e\n\u003cp\u003eA: You must maintain a single-point ground for the cable shield at the monitoring system interface. Connecting the shield at both ends creates ground loops, which introduce 50\/60 Hz interference into the vibration signal.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable be used for high-temperature turbine applications?\u003c\/p\u003e\n\u003cp\u003eA: While the cable supports operation up to +80 deg C, you must utilize high-temperature extension cables for zones exceeding this threshold. You should verify the ambient temperature at the probe connection point before final cable routing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting:\u003c\/strong\u003e Avoid bending the cable tighter than the manufacturer-specified minimum radius. Sharp bends stress the internal conductors and degrade the shielding effectiveness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Ensure the coaxial connectors are clean and free of debris. Tighten the connector to the specified torque to prevent intermittent electrical contact during machine operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Route the cable through protective conduit in areas prone to mechanical impact. The interlocking armor provides physical strength, but it does not replace the requirement for conduit in harsh process zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e Perform a continuity check and inspect for shorts between the center conductor and the shield before system commissioning. Ensure the loop resistance matches the value expected for a 15-foot cable run to confirm internal integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057274454106,"sku":"16710-15","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/254.jpg?v=1773624071"},{"product_id":"bently-nevada-9200-01-05-01-00-two-wire-velocity-probe","title":"Bently Nevada 9200-01-05-01-00 Two-Wire Velocity Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9200-01-05-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision two-wire Seismoprobe velocity transducer designed for continuous machinery protection and condition monitoring. Unlike standard accelerometers, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries utilizes moving-coil technology to provide a self-generated voltage signal proportional to vibration velocity, making it ideal for monitoring bearing housings, casings, and structural vibrations in rotating equipment. This specific configuration features a 0° mounting angle and a top-mount terminal block, engineered for reliability in power generation, oil and gas, and heavy manufacturing environments where the detection of low-to-medium frequency mechanical faults is critical.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9200-01-05-01-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e: Two-Wire Seismoprobe Velocity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Angle Option (01)\u003c\/strong\u003e: 0° ±2.5° (Vertical orientation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Operating Frequency\u003c\/strong\u003e: 4.5 Hz (270 cpm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Option (05)\u003c\/strong\u003e: Terminal block, top-mount orientation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Base Option (10)\u003c\/strong\u003e: Circular base with M10 x 1 threaded stud\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval (00)\u003c\/strong\u003e: No approvals required (Standard industrial version)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: 10 Hz to 1,000 Hz ±3.0 dB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: Self-generating voltage proportional to velocity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -35°C to +121°C (-31°F to +250°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e: 300-series stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.3 kg (Transducer unit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057384620122,"sku":"9200-01-05-10-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/259._51ba5549-f5be-4396-82cd-45a94d3809ca.jpg?v=1773625686"},{"product_id":"9200-01-05-10-00-bently-nevada-seismoprobe-velocity-transducer","title":"9200-01-05-10-00 Bently Nevada Seismoprobe Velocity Transducer","description":"\u003ch2\u003eBently Nevada 9200-01-05-10-00 Seismoprobe Velocity Transducer\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-01-05-10-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e9200\u003c\/strong\u003e Seismoprobe, operates as a dedicated hardware component for measuring absolute vibration velocity of bearing housings and structural components within industrial monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9200-01-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard industrial housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSelf-generating (Passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eProportional voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200\u003c\/strong\u003e series transducer utilizes a moving-coil design that generates a voltage output directly proportional to vibration velocity, providing performance optimized for low-to-medium frequency ranges. This device facilitates machinery protection by tracking absolute housing vibration, which allows for effective monitoring of bearing health. The sensor design requires vertical mounting orientation (0 deg ±2.5 deg) to maintain accurate rotor dynamics feedback and signal calibration. Cross-talk suppression is inherent in the robust seismoprobe construction, ensuring that housing vibrations are isolated from external environmental interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the transducer require an external power supply? A: No, the 9200-01-05-10-00 is an electrodynamic sensor that self-generates the output signal, functioning as a passive two-wire device.\u003c\/p\u003e\n\u003cp\u003eQ: How is the transducer integrated into the field environment? A: The device features a top-mount terminal block for wiring and a circular M10 x 1 threaded base, which permits secure attachment to bearing housings and structures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the mounting surface is prepared for the M10 x 1 threaded stud to guarantee a stable mechanical connection.\u003c\/li\u003e\n\u003cli\u003eVerify that the transducer is oriented vertically to meet the specified 0 deg ±2.5 deg mounting requirements.\u003c\/li\u003e\n\u003cli\u003eTerminate the field wiring at the top-mount terminal block, ensuring correct polarity for the self-generating voltage output.\u003c\/li\u003e\n\u003cli\u003eConfirm the installation complies with API 670 guidelines for machinery protection systems before system initialization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057386848346,"sku":"9200-02-01-10-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/261_6442f474-1971-4325-b41e-69af727cbfb7.jpg?v=1773626686"},{"product_id":"79512-03-bently-nevada-3500-high-performance-monitor","title":"79512-03 Bently Nevada 3500 High-Performance Monitor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e79512-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Keyphasor Monitor Module designed for the Bently Nevada 3500 series machinery protection system. This dual-channel module is fundamental for advanced machinery diagnostics, providing a highly accurate phase reference signal derived from shaft rotation. By processing inputs from proximity probes or magnetic pickups, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e79512-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egenerates a digital pulse once per revolution, enabling the monitoring system to calculate precise shaft speed and phase-locked vibration data. This information is critical for distinguishing between mechanical unbalance, misalignment, and other synchronous faults in high-speed turbines, compressors, and large industrial motors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e79512-03\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Dual-Channel Keyphasor Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e: 3500 Monitoring System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Support\u003c\/strong\u003e: Proximity Transducers, Magnetic Pickups, and Active (non-contact) Speed Sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: TTL-compatible Keyphasor pulse to the 3500 system backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e: Two independent channels (supports redundancy or multiple shaft speeds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: Supports shaft speeds from 1 RPM to 99,999 RPM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: Typically \u0026lt;5 Watts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -30°C to +65°C (-22°F to +150°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Standard 3500 Rack internal slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.998 kg (1000g)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057436852314,"sku":"79512-03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/267..jpg?v=1773629143"},{"product_id":"81228-01-bently-nevada-rtd-tc-input-monitor-6-channel","title":"81228-01 Bently Nevada RTD\/TC Input Monitor 6-Channel","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e81228-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Six-Channel Temperature Monitor module specifically engineered for the Bently Nevada 3300 series machinery protection system. This high-reliability module provides continuous surveillance of critical machinery temperatures by interfacing with Resistance Temperature Detectors (RTDs) or Thermocouples (TCs). By monitoring bearing temperatures, winding temperatures, and lubrication fluid states, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e81228-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eidentifies thermal trends that could indicate mechanical friction, cooling failure, or impending bearing seizure. It integrates seamlessly into the 3300 rack to provide local display and relay-driven protective shutdowns, ensuring that high-speed rotating assets are protected against catastrophic thermal events.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eThermal Asset Protection and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e81228-01\u003c\/strong\u003e is designed to meet the rigorous requirements of API 670 for machinery protection. Adhering to technical Google E-E-A-T principles, this module employs high-resolution analog-to-digital conversion and cold-junction compensation (for thermocouples) to ensure precision readings in volatile industrial environments. Unlike vibration monitoring alone, temperature tracking via the \u003cstrong\u003e81228-01\u003c\/strong\u003e provides a vital secondary indicator of machine health—often detecting lubrication issues or load imbalances before they manifest as increased vibration. The module features comprehensive self-diagnostics, including \"NOT OK\" circuit detection to prevent false trips caused by sensor wire breaks or short circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e81228-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Six-Channel Temperature Monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e: 3300 Monitoring System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring Channels\u003c\/strong\u003e: 6 independent channels per module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility\u003c\/strong\u003e: Supports RTDs (e.g., Pt100) and various Thermocouple types (config-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±1°C (±2°F) typical at room temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e: 4-20 mA proportional analog outputs for PLC\/DCS integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Configuration\u003c\/strong\u003e: Independent Alert and Danger setpoints for each channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e: Dry contact relays for protective machinery trips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: Integrated front-panel digital display for real-time temperature tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Internal slot installation for 3300 series 6-slot or 14-slot chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057510023258,"sku":"81228-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/271.1_ff03479f-1513-4a11-ae30-e3387cc468b1.jpg?v=1773630913"},{"product_id":"109549-01-bently-nevada-3300-xl-nsv-photoelectric-proximity-probe","title":"109549-01 Bently Nevada 3300 XL NSv Photoelectric Proximity Probe","description":"\u003ch2\u003eBently Nevada 109549-01 NSv Photoelectric Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 109549-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e109549-01\u003c\/strong\u003e Photoelectric Proximity Probe, operates as a dedicated hardware component for measuring shaft speed, vibration, and position within 3300 XL NSv transducer system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e109549-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e188 mm case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConsult manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eZero-speed to high-speed diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 109549-01\u003c\/strong\u003e utilizes NSv technology optimized for small-shaft machinery, specifically targets with diameters under 51 mm (2 inches). The probe facilitates precise tachometer readings and overspeed protection by providing high-resolution data relevant to rotor dynamics. Integration requires adherence to eddy-current probe scaling principles adapted for non-contact photoelectric sensing to ensure accurate shaft position and vibration capture. The sensor design incorporates cross-talk suppression to maintain signal fidelity in tight physical constraints where multiple transducers may be installed in close proximity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this probe compatible with standard 3300 XL eddy-current systems? A: The probe is engineered specifically for the 3300 XL NSv (Narrow Side-view) system and is utilized where standard eddy-current proximity probes are unsuitable due to tight physical constraints or small target diameters.\u003c\/p\u003e\n\u003cp\u003eQ: Does the probe require specialized hazardous area approvals? A: Yes, the probe is ATEX, IECEx, FM, and CSA compliant, making it suitable for use in diverse industrial hazardous environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the mounting location provides adequate clearance for the 188 mm overall case length.\u003c\/li\u003e\n\u003cli\u003ePosition the probe to align with targets under 51 mm for shafts or under 15 mm for flat target configurations to ensure measurement precision.\u003c\/li\u003e\n\u003cli\u003eRoute the transducer cabling in accordance with industrial standards, ensuring proper shielding is maintained to prevent electrical interference.\u003c\/li\u003e\n\u003cli\u003eVerify the probe output during machinery commissioning to confirm it provides the expected phase reference and tachometer signals for the associated protection system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057516380250,"sku":"109549-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/275.jpg?v=1773632421"},{"product_id":"bently-nevada-79492-01-3300-series-six-channel-temperature-monitor","title":"Bently Nevada 79492-01 3300 Series Six-Channel Temperature Monitor","description":"\u003ch2\u003eBently Nevada 79492-01 Six-Channel Temperature Monitor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 79492-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e79492-01\u003c\/strong\u003e Six-Channel Temperature Monitor, operates as a dedicated hardware component for continuous thermal surveillance of critical industrial assets within Bently Nevada 3300 series machinery protection system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e79492-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eConsult 3300 System Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConsult 3300 System Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Channels\u003c\/td\u003e\n\u003ctd\u003e6 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n\u003ctd\u003eResistance Temperature Detectors (RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 79492-01\u003c\/strong\u003e performs static temperature monitoring by interfacing directly with RTDs to measure bearing metal temperatures, stator windings, and lubrication systems. The module incorporates individual channel bypass and self-test capabilities, enabling verification of relay logic and alarm thresholds without interrupting active monitoring of remaining channels. Integrated \"NOT OK\" circuitry provides fault detection by sensing transducer and wiring integrity. By processing these thermal inputs, the device facilitates the establishment of precise temperature baselines and dual-level alarm logic to monitor for thermal growth or bearing friction.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module allow for testing alarm thresholds while the system is in operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module features individual channel bypass and self-test capabilities, which permit technicians to verify relay logic and alarm thresholds without interrupting the monitoring of other healthy channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the monitor integrate with external control systems?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 4-20 mA proportional analog signals, which allow for direct integration into external DCS or PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the 3300 monitoring rack is de-energized to prevent electrical shorts during the installation of the analog assembly.\u003c\/li\u003e\n\u003cli\u003eSlide the 79492-01 into the designated slot within the 3300 series rack, ensuring proper alignment with the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eTerminate RTD sensor wiring to the corresponding terminal blocks, maintaining correct polarity and shield grounding to minimize noise interference.\u003c\/li\u003e\n\u003cli\u003ePerform a system-level checkout to confirm that the \"NOT OK\" circuit validates transducer integrity and that alarm thresholds are correctly configured for the specific machinery asset.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057519951962,"sku":"79492-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/277..jpg?v=1773633105"},{"product_id":"102566-02-bently-nevada-3300-xl-proximitor-sensor","title":"102566-02 Bently Nevada 3300 XL Proximitor Sensor","description":"\u003ch2\u003eBently Nevada 102566-02 Proximitor Sensor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 102566-02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e102566-02\u003c\/strong\u003e Proximitor Sensor, operates as a dedicated hardware component for converting eddy-current probe signals into linearized voltage outputs within 3300 XL proximity transducer system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e102566-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eConsult manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 3300 XL form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e-200 mV\/mil (7.87 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 102566-02\u003c\/strong\u003e executes precision eddy-current probe scaling to ensure vibration and position data remain accurate across varying operating conditions. System integration necessitates strict gap voltage validation, targeting -10 VDC levels to maintain linear measurement ranges for turbine and compressor monitoring. The sensor design utilizes internal circuitry to manage signal characteristics relevant to rotor dynamics, enabling the detection of sub-synchronous or synchronous vibration components. Additionally, the hardware architecture implements cross-talk suppression, which isolates signal paths when multiple proximity probes are installed in close proximity on the same machine casing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 102566-02 require specific system length calibration? A: Yes, the system must be configured for either 5.0 meter or 9.0 meter total system lengths (probe, extension cable, and proximitor) to ensure impedance matching and signal accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Can this sensor be used in hazardous environments? A: The device maintains compatibility with CSA, ATEX, and IECEx standards; however, users must verify the specific unit labeling against site-specific hazardous area requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the 3300 XL proximity probe and extension cables for physical degradation before connecting them to the proximitor.\u003c\/li\u003e\n\u003cli\u003eMount the proximitor in a dry, accessible enclosure, ensuring the housing remains securely grounded to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003eApply a stable power supply between -17.5 Vdc and -26 Vdc to the proximitor power terminals.\u003c\/li\u003e\n\u003cli\u003ePerform gap voltage checks at the probe tip to verify the -10 VDC target before commissioning the signal loop for machine protection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057524932698,"sku":"102566-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/279.jpg?v=1773639652"},{"product_id":"rugged-sensor-mounting-kit-164952-01-01-bently-nevada","title":"Rugged Sensor Mounting Kit | 164952-01-01 Bently Nevada","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e164952-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision-engineered Accelerometer Mounting Kit designed to provide a secure, high-integrity mechanical interface for Bently Nevada vibration sensors. In industrial condition monitoring, the quality of the sensor-to-machine coupling is the single most critical factor for data accuracy. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e164952-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that accelerometers are firmly attached to equipment casings, minimizing resonance and signal distortion across high-frequency ranges. This kit also provides essential environmental protection, shielding sensitive transducers from moisture, dust, and mechanical impact in harsh industrial environments like refineries and power generation plants.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e164952-01-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Accelerometer Mounting Kit \/ Protective Housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Sensor stabilization, signal optimization, and environmental shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e: Precision-machined, rugged industrial-grade alloy\/composite\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Interface\u003c\/strong\u003e: Supports standard Bently Nevada accelerometer bolt patterns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 133 mm x 133 mm x 178 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.74 kg to 0.82 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e: Designed for high-moisture and high-dust industrial zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE compliant; suitable for API 670 machinery protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Optimized for Bently Nevada 330400, 330450, and 350300 series accelerometers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e: 12 Months\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43057681236058,"sku":"164952-01-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/281..jpg?v=1773640347"},{"product_id":"285691-01-bently-nevada-3500-42e-encore-4-channel-monitor","title":"285691-01 | Bently Nevada | 3500\/42E Encore 4-Channel Monitor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285691-01\u003c\/strong\u003e) is a high-performance, 4-channel machinery protection module designed for the Bently Nevada 3500 Series Rack. As an \"Encore\" series module, it is specifically engineered to provide a seamless upgrade or replacement path for legacy vibration monitoring systems while maintaining full compatibility with modern Proximitor* proximity sensors and seismic transducers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously processes signals to provide critical radial vibration, thrust position, and differential expansion measurements for high-speed rotating machinery.\u003c\/p\u003e\n\u003cp\u003eEach channel of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285691-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis independently programmable via the 3500 Rack Configuration Software, allowing it to perform specialized functions such as shaft absolute measurement, eccentricity, acceleration, and velocity monitoring. The module compares conditioned signals against user-defined Alert and Danger setpoints, providing real-time machinery protection. This ensures early detection of mechanical issues like imbalance, misalignment, and bearing wear in turbines, compressors, and large industrial pumps. Its high sampling rate and dynamic range make it a cornerstone for Reliability-Centered Maintenance (RCM) and plant safety protocols.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42E\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285691-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e: 4 independent channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e: Radial Vibration, Thrust Position, Differential Expansion, Shaft Absolute, Eccentricity, Acceleration, Velocity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Acceptance\u003c\/strong\u003e: Proximitor proximity probes, seismic sensors (Velocity\/Accelerometers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: 0.1 Hz to 10 kHz (sensor dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Processing\u003c\/strong\u003e: True RMS, Peak, Peak-to-Peak detection; configurable digital filters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: Within ±1% of full-scale range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e: Programmable Alert and Danger thresholds for each channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e: Front-panel coaxial connectors for dynamic signal analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Output\u003c\/strong\u003e: 4–20 mA current loops and relay contact integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -30 °C to +65 °C (-22 °F to +149 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 228 mm x 50 mm x 289 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 1.27 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE, CSA, ATEX (Hazardous Area Rated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Application \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285691-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for high-criticality assets in power plants and petrochemical facilities where unplanned downtime results in significant revenue loss. The module’s ability to handle multiple measurement types—such as switching between radial vibration for journal bearings and thrust position for axial load monitoring—provides engineers with the flexibility to protect diverse machine trains. By integrating the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto a 3500 rack, facilities gain a deterministic protection layer that operates independently of the plant DCS, ensuring safety even during network interruptions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3500\/42E compatible with older 3500 rack backplanes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285691-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to fit standard 3500 Series racks. However, you should verify that your 3500 Rack Configuration Software version supports the 42E \"Encore\" firmware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module include the I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285691-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically refers to the main monitor module. Depending on your wiring requirements (internal or external termination), you may require a specific I\/O module such as the 128229-01 or 128240-01.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43091528843354,"sku":"3500\/42E 285691-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/284..jpg?v=1774247050"},{"product_id":"bently-nevada-3500-93-135785-01-api-670-system-monitor","title":"Bently Nevada 3500\/93 135785-01 API 670 System Monitor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/93\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135785-01\u003c\/strong\u003e) is a high-resolution Graphical LCD System Display designed for the Bently Nevada 3500 Machinery Protection System. This module provides localized visualization of critical asset condition data, allowing operators to monitor real-time machinery health without a separate workstation. With a 640 x 480 pixel resolution, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135785-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers clear, actionable information including system event lists, alarm logs, and all rack-resident data such as channel values, monitor statuses, relay states, and Keyphasor* tachometer readings.\u003c\/p\u003e\n\u003cp\u003eEngineered for extreme industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/93\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures an exceptionally wide operating temperature range from -40°C to +85°C, making it suitable for outdoor cabinets or high-heat processing areas. The display can be face-mounted directly onto the 3500 rack or remotely positioned for improved ergonomic access. By adhering to API 670 requirements, this display module ensures that safety-critical information is always available to maintenance personnel, facilitating rapid response to vibration anomalies or mechanical faults in turbines, compressors, and large-scale pump trains.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/93\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135785-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(often paired with E4482 components)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e: Backlit Graphical LCD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 640 x 480 Pixels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Refresh Rate\u003c\/strong\u003e: 200 Hz internal acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e: Ethernet\/IP (via Display Interface Module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 12 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e: Face mount (Slot 15), Rack, Panel, or Independent remote mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40 °C to +85 °C (-40 °F to +185 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 °C to +105 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 150 mm x 120 mm x 30 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.2 kg (Net)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e: API 670, CE, UL, IEC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration \u0026amp; Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135785-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates in conjunction with the 3500\/93 Display Interface Module (DIM). For face-mount applications, the DIM must be installed in Slot 15 (the right-most slot) of the 3500 chassis to properly drive the display. Unlike the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/94\u003c\/strong\u003e, which utilizes a VGA output for larger external touchscreens, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/93\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(135785-01) provides a compact, ruggedized integrated viewing solution directly at the machinery protection rack. It is the preferred choice for petrochemical and power generation facilities requiring reliable, local situational awareness in harsh field conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 135785-01 compatible with the 3500\/94 VGA system?\u003c\/strong\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135785-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a proprietary LCD designed specifically for the 3500\/93 system architecture. The 3500\/94 uses standard VGA monitors and is a different hardware branch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mount this display several meters away from the rack?\u003c\/strong\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/93\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem supports independent and panel mounting. However, ensure that the cable length between the DIM and the display remains within Bently Nevada's specified signal integrity limits for Ethernet\/IP or proprietary links.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43092120731738,"sku":"3500\/93 135785-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/287..jpg?v=1774248759"},{"product_id":"bently-nevada-176449-02-sil2-certified-4-channel-monitor","title":"Bently Nevada 176449-02 SIL2 Certified 4-Channel Monitor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e) is a high-reliability, 4-channel Proximitor Seismic Monitor designed for the Bently Nevada 3500 Machinery Protection System. This specific configuration,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42-09-00\u003c\/strong\u003e, is an \"Enhanced\" monitor (M series) integrated with SIL2 functional safety certification. It is engineered to accept inputs from a wide array of transducers, including Proximitor* proximity probes, seismic velocity sensors, and accelerometers, providing continuous protection for critical rotating assets such as turbines, compressors, and high-pressure pumps.\u003c\/p\u003e\n\u003cp\u003eWhat sets the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42M-SIL2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapart is its compliance with IEC 61508 standards for functional safety. It doesn't just measure radial vibration, thrust position, and shaft dynamic signals; it does so with a mathematically proven level of reliability required for Safety Instrumented Systems (SIS). The module conditions these signals in real-time and compares them against user-programmable Alert and Danger setpoints. When paired with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e09\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O module (featuring internal terminations), it supports Prox\/Velom, Prox\/Accel, and Velomitor configurations, ensuring flexible field wiring and reduced cabinet space requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42M\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Code\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42-09-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain Module PN\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada (Baker Hughes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring Channels\u003c\/strong\u003e: 4 Independent Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e: SIL2 Certified (IEC 61508)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Type\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e09\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Prox\/Velom with Internal Terminations)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Types\u003c\/strong\u003e: Radial Vibration, Thrust Position, Shaft Absolute, Eccentricity, Velocity, Acceleration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: 0.1 Hz to 10 kHz (Sensor dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e: True RMS, Peak, and Peak-to-Peak detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±1% of full-scale range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -30 °C to +65 °C (-22 °F to +149 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 241.3 mm x 24.4 mm x 241.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e: 2.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e: API 670, SIL2, CE, CSA, ATEX\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication \u0026amp; Safety Role\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42M 176449-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the standard choice for petrochemical plants, power stations, and LNG facilities where the machinery protection system must interface with a Safety Instrumented System (SIS). The SIL2 rating ensures that the probability of failure on demand is extremely low, protecting not only the equipment but the personnel and the environment. By using the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e09\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O option, engineers can connect various sensor types—including the high-temperature HTVS sensors—directly to the module’s internal terminal blocks without needing external termination panels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 3500\/42M in a non-SIL application?\u003c\/strong\u003eYes. While the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e176449-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis SIL2 certified, it functions perfectly in standard machinery protection roles. It provides superior signal processing and diagnostic capabilities compared to legacy non-\"M\" modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the internal termination (Option 09)?\u003c\/strong\u003eInternal termination allows for a cleaner installation within the 3500 rack. The field wiring from the sensors connects directly to the terminal blocks on the I\/O module at the rear of the rack, simplifying maintenance and troubleshooting.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43092315570266,"sku":"3500\/42M-SIL2-09-R0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/290._4cb0c4a7-5587-4ec2-93fc-3193de5f9e1f.jpg?v=1774249796"},{"product_id":"145004-47-bently-nevada-3300-xl-11mm-proximitor-sensor","title":"145004-47 | Bently Nevada | 3300 XL 11mm Proximitor Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330180-X1-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e145004-47\u003c\/strong\u003e) serves as the high-precision signal conditioning core for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL 11mm Proximity Transducer System\u003c\/strong\u003e. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal Proximitor sensor utilizes advanced eddy-current technology to track shaft vibration and axial position without physical contact. Specifically engineered for 11mm probe systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e145004-47\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers a linear voltage output directly proportional to the distance between the probe face and the target shaft. Engineers specify this 11mm configuration over standard 8mm units when the application requires enhanced mechanical robustness and superior signal stability in heavy-duty turbomachinery environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration (MOD\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e145004-47\u003c\/strong\u003e) defines the specific calibration parameters required for industrial machinery protection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180\u003c\/strong\u003e: 3300 XL Proximitor Sensor Base Model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX1\u003c\/strong\u003e: Performance series designation for high-reliability vibration monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 5.0-meter total system length calibration (matches 5m probe and extension cable sets).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD 145004-47\u003c\/strong\u003e: Specialized modification for 11mm probe system sensitivity and scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Probe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 11mm Proximity Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 V\/mm (100 mV\/mil) Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 mm (160 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz (DC) to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 Meters (Factory Calibrated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithin ±0.25% of full-scale range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 °C to +100 °C (-31 °F to +212 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 Vdc to -26 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAPI 670 Machinery Protection standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncreased Mechanical Strength:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 11mm probe system, powered by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e145004-47\u003c\/strong\u003e, offers a larger measurement footprint than 8mm sensors. This design provides superior performance on large-diameter shafts where surface irregularities or larger gap requirements demand higher signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Thermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries circuitry minimizes temperature drift. The Proximitor maintains an accurate 100 mV\/mil output even during rapid thermal cycling in steam turbine environments, preventing false vibration alerts and nuisance trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Signal Delivery:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor produces a low-impedance analog signal that remains resilient against electromagnetic interference (EMI). This allows the signal to travel long distances from the machine to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/42M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitor in the control room without data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Interchangeability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-standardized calibration allows maintenance teams to replace a damaged Proximitor without performing a complex field recalibration. Simply matching any 5-meter 11mm probe set to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e145004-47\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erestores the protection loop to full operational accuracy immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 145004-47 with an 8mm proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e145004-47\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically tuned for the electrical characteristics of an 11mm probe tip. Connecting it to an 8mm probe results in incorrect scale factors and non-linear measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable length does this Proximitor support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific module is calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0-meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etotal system length. You must ensure the combined length of your proximity probe and extension cable equals 5 meters to maintain specified accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"MOD\" designation affect installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD 145004-47\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eidentifies the unit as part of the 11mm transducer family. While the exterior housing matches other 3300 XL sensors, the internal gain curves are unique to the 11mm probe’s larger magnetic field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43093543190618,"sku":"145004-47","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/295_43f6694f-b3cf-4929-bf1b-93d297d6ef4c.jpg?v=1774252360"},{"product_id":"ez1900-080-emerson-ams-ez-1000-sensor-cable","title":"EZ1900-080 | Emerson AMS | EZ 1000 Sensor Cable","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson EZ1900-080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized 8-meter extension cable for the AMS EZ 1000 series eddy current proximity sensors. This cable bridges the critical gap between the displacement sensor and the monitoring transmitter, facilitating precise measurement of shaft vibration, eccentricity, and axial displacement. Specifically engineered for large rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEZ1900-080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains the impedance and signal integrity required for accurate data acquisition in turbines, compressors, and high-speed fans. We supply this cable as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment to guarantee the performance and reliability of your machinery protection system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEZ1900-080\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMS EZ 1000 Eddy Current Sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 Meters (Approx. 26.2 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-Armored (Flexible Shielded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Sensors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMS EZ 1000 Proximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFerromagnetic steels (42CrMo4, P235S, ASTM A276 Type 410)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin. Shaft Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 mm (3.15\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin. Target Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 mm (1.57\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTurbines, Gearboxes, Compressors, Pumps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Signal Transmission\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEZ1900-080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a shielded, low-capacitance design that prevents signal attenuation over its 8-meter length. This ensures that the vibration monitoring system receives a high-fidelity representation of shaft movement without electronic noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Installation Pathing\u003c\/strong\u003e: The non-armored construction provides a tight bend radius compared to corrugated armored variants. This flexibility allows technicians to route the cable through narrow conduit or complex internal machine housings where space is limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Calibration Matching\u003c\/strong\u003e: Emerson engineers this cable to match the electrical characteristics of the AMS EZ 1000 system. Using the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEZ1900-080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for recalibrating the transmitter to account for non-standard cable resistance or impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLightweight Durability\u003c\/strong\u003e: Despite its length, the cable remains lightweight (0.5 kg), reducing mechanical stress on junction box connectors and sensor leads during high-vibration operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the EZ1900-080 in environments with high mechanical impact?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEZ1900-080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a non-armored design for maximum flexibility. For installations where the cable faces exposure to falling debris or heavy physical contact, you must use an armored variant or provide protective rigid conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this extension cable affect the sensor's accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AMS EZ 1000 system requires a specific total cable length for calibrated accuracy. Ensure your transmitter and sensor settings match the 8-meter length of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEZ1900-080\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain precise displacement measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with 42CrMo4 and other common shaft materials?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The cable supports signal transmission for sensors targeting various ferromagnetic steels, including 42CrMo4, P235S, and ASTM A276 Type 410, common in industrial turbomachinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43130982695002,"sku":"EZ1900-080","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/232_02b7f581-1203-47c7-94d6-dc695bec9016.jpg?v=1774505929"},{"product_id":"emerson-ez1080-08-00-010-non-contact-displacement-sensor","title":"Emerson EZ1080-08-00-010 Non-Contact Displacement Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson EZ1080-08-00-010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-precision 8mm eddy current proximity probe within the AMS EZ 1000 and AMS 8000 series machinery protection systems. This sensor provides non-contact measurement of shaft vibration, axial displacement, and eccentricity in critical rotating equipment. Its compact M10×1 threaded body and 8mm tip diameter allow for installation in confined bearing housings where space is limited. We supply this probe as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment, ensuring deterministic data acquisition for your power generation or petrochemical assets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEZ1080\u003c\/strong\u003e: Base Series (8mm Eddy Current Probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-08\u003c\/strong\u003e: 8.0 mm Probe Tip Diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Standard Mount (Non-Armored Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-010\u003c\/strong\u003e: 1.0 Meter Integral Cable Length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEZ1080-08-00-010\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMS EZ 1000 \/ AMS 8000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBody Thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 × 1.0 (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Meter Integral Cable (Non-Armored)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Jacket\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyurethane Shielded\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 mm to 2.0 mm (Standard Gap)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFerromagnetic Steels (42CrMo4, P235S, C35, 410 SS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–35°C to +180°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin. Shaft Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 mm (3.15\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin. Target Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 mm (1.57\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Temperature Resilience\u003c\/strong\u003e: The probe operates reliably in extreme thermal environments ranging from –35°C up to +180°C. This wide range ensures stable displacement readings inside high-pressure steam turbines and gas compressors where internal temperatures fluctuate significantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Signal Quality\u003c\/strong\u003e: The polyurethane-jacketed shielded cable suppresses electromagnetic interference (EMI) from nearby high-voltage motors. This shielding preserves the integrity of the micro-displacement signals, preventing false trips in your machinery protection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Threaded Profile\u003c\/strong\u003e: The M10×1 threaded stainless-steel housing facilitates precise mechanical gapping. Technicians can fine-tune the sensor-to-shaft distance with high granularity, ensuring the probe remains within the linear operating range of 0.25 to 2.0 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation Protection\u003c\/strong\u003e: Integrated isolation barriers prevent ground loops between the probe body and the system electronics. This design eliminates electrical noise that often contaminates vibration data in large-scale industrial grid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the EZ1080-08-00-010 compatible with 3rd party extension cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe recommend using only Emerson AMS EZ 1000 series extension cables. Eddy current systems depend on specific system impedance; using non-certified cables will result in calibration drift and inaccurate vibration measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this probe in a splash zone with turbine oil?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The stainless-steel housing and polyurethane cable jacket resist common industrial lubricants and hydraulic fluids. However, ensure the connector remains outside the fluid area or use specialized sealing kits to prevent oil ingress into the electrical junctions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1.0-meter integral cable require a driver to function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEZ1080-08-00-010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a passive sensor head. It requires an AMS EZ 1000 Eddy Current Converter (Driver) to translate the proximity signal into a standard voltage or current output for your DCS or PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43131219345498,"sku":"EZ1080-08-00-010","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/323._474966e5-2292-465f-a9e3-22ccd089b4dc.jpg?v=1774506480"},{"product_id":"ams-ez1000-emerson-proximity-sensor-brand-new","title":"AMS EZ1000 Emerson Proximity Sensor Brand New","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson AMS EZ1000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents a modular, high-performance eddy current sensor system engineered for the deterministic monitoring of critical rotating machinery. This system—comprising precision probes, extension cables, and signal converters—tracks shaft vibration, axial displacement, and eccentricity without mechanical contact. By delivering real-time data to the AMS 8000 machinery protection suite, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEZ1000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents catastrophic equipment failure in power plants, refineries, and chemical processing facilities. We provide these components as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment to ensure your facility maintains the highest standards of E-E-A-T (Experience, Expertise, Authoritativeness, and Trustworthiness).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAMS EZ1000\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Sizes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mm, 8 mm, 11 mm (Application Dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 mm to 2.0 mm (Typical Gap)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFerromagnetic Steels (42CrMo4, P235S, C35, 410 SS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +180°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegral Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 m to 10.0 m Options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable in Armored and Non-Armored variants\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin. Shaft Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥80 mm (3.15”)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully compatible with AMS 8000 \/ AMS 6500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Signal Accuracy\u003c\/strong\u003e: The EZ1000 system utilizes eddy current technology to measure the distance between the probe tip and the target material with sub-micron resolution. This allows engineers to detect microscopic shaft movements before they escalate into mechanical failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Installation Flexibility\u003c\/strong\u003e: The system architecture supports various integral and extension cable lengths (up to 10 meters). This modularity allows for the placement of drivers in protected cabinets while the sensors operate within the harsh, high-temperature environment of the turbine housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior EMI Shielding\u003c\/strong\u003e: Emerson employs specialized shielding in both the probe leads and extension cables. This protection eliminates signal \"noise\" from nearby large motors or power lines, ensuring that the vibration data reflects actual shaft behavior rather than electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized for Extreme Environments\u003c\/strong\u003e: With an operating temperature range reaching +180°C and options for stainless steel armor, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEZ1000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esurvives continuous exposure to hot turbine oil, high-pressure steam, and corrosive atmospheric gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I select the correct probe tip size?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSelect the tip size (5mm, 8mm, or 11mm) based on your required measurement range and target area. Smaller tips (5mm) offer high sensitivity in tight spaces, while larger tips (11mm) provide an extended linear range for significant axial displacement monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix non-armored probes with armored extension cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided the electrical lengths and impedance remain compatible. However, we recommend maintaining consistent armor protection across the entire cable run in environments where mechanical abrasion or fluid exposure is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the EZ1000 system require manual calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the probes are factory-calibrated for specific target materials (typically 42CrMo4), you must perform a \"gap voltage\" check during installation using a multimeter to ensure the sensor sits within its linear operating region (typically -10V DC for a mid-range gap).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43131244740698,"sku":"EZ1000","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/326._7fc117df-50f9-4206-b68c-89a55381ff46.jpg?v=1774506774"},{"product_id":"pr6423-01h-030-emerson-non-contact-displacement-sensor","title":"PR6423\/01H-030 Emerson Non-Contact Displacement Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson CON021 + PR6423\/01H-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassembly provides a complete, high-precision solution for non-contact machinery monitoring. This modular system pairs the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\/01H-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8mm eddy current probe with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal conditioning driver to translate physical shaft displacement into accurate electronic signals. Engineered for the AMS Machinery Protection series, this combination tracks shaft vibration, axial position, and eccentricity in high-speed turbines, compressors, and pumps. We supply this entire assembly as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment to ensure your mission-critical assets remain protected by authentic Emerson technology.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\/Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Assembly\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCON021 + PR6423\/01H-030\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 Meters (Integral, Non-Armored)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 mm to 2.0 mm (Linear Gap)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFerromagnetic Steels (e.g., 42CrMo4, ASTM A276 Type 410)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConditioned Voltage Output for AMS 8000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +180°C (Probe Tip)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation between Probe and System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin. Shaft Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥80 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMin. Target Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePre-Matched Impedance\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edriver matches the electrical impedance of the 3.0m\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprobe cable. This factory-aligned pairing eliminates the need for manual field calibration, ensuring the output voltage accurately represents the physical gap immediately upon installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Conditioning\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edriver filters out electronic background noise and amplifies the micro-vibrations detected by the probe. This ensures that your monitoring system receives a \"clean\" signal, which is critical for identifying early-stage bearing wear or shaft misalignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Temperature Durability\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprobe survives continuous operation in temperatures up to +180°C. This allows for direct installation inside the turbine or gearbox housing where heat levels typically degrade standard proximity sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Contact Precision\u003c\/strong\u003e: By utilizing eddy current technology, the sensor monitors the shaft without physical touch. This eliminates mechanical wear and ensures the system provides reliable data for years without requiring recalibration or component replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the PR6423\/01H-030 without the CON021 driver?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprobe is a passive sensor that requires the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edriver to provide the excitation frequency and condition the return signal. Using the probe without its matched driver will result in no signal output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the initial gap for this 8mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians typically use a multimeter to measure the DC output voltage from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e. For a standard 2.0 mm range, you generally aim for a \"middle\" voltage (often -10V DC) that corresponds to a gap of approximately 1.0 mm to 1.25 mm from the shaft surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3.0m cable length fixed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for exactly 3.0 meters of integral cable. You should not cut or shorten this cable, as doing so will change the system impedance and invalidate the calibration. If your installation requires more distance, use a certified Emerson extension cable designed for the AMS series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43131253293146,"sku":"CON021+PR6423\/01H-030","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/327._8e89ef46-e5e3-49b9-8f9e-6063c11aa282.jpg?v=1774507087"},{"product_id":"pr6423-01c-030-emerson-8mm-eddy-current-sensor-3m-cable","title":"PR6423\/01C-030 Emerson 8mm Eddy Current Sensor 3m Cable","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson CON021 + PR6423\/01C-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassembly constitutes a modular, industrial-grade solution for the non-contact measurement of shaft vibration and displacement. This high-performance kit pairs the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\/01C-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earmored 8mm probe with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal converter (driver). The system excels in steam, gas, and hydro turbine applications where detecting radial and axial movement is critical for operational safety. The armored cable construction provides essential mechanical protection in high-stress environments. We supply this complete assembly as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment, ensuring full compatibility with Emerson AMS 8000 and EPRO monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Breakdown: PR6423\/01C-030\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePR6423\u003c\/strong\u003e: 8 mm Tip Diameter Eddy Current Probe Series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01C\u003c\/strong\u003e: Armored Cable Version (provides superior mechanical protection against abrasion and fluid ingress).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e030\u003c\/strong\u003e: 3.0 Meter (approx. 9.8 ft) Integral Cable Length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\/Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (USA \/ EPRO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Assembly\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCON021 + PR6423\/01C-030\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eArmored, 3.0 Meter Integral Length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDriver Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 15 μs (Ultra-fast response)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 20 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 mm to 2.0 mm (Linear Gap)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFerromagnetic Steels (e.g., 42CrMo4, ASTM A276 Type 410)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–35°C to +180°C (Probe Tip)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic isolation between field and system electronics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX Certified for hazardous areas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Mechanical Durability\u003c\/strong\u003e: The \"01C\" designation specifies an armored cable jacket. This ruggedized layer protects the internal coaxial leads from mechanical crushing, sharp bends, and caustic turbine oils, significantly extending the service life in harsh chemical or power generation environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Diagnostic Precision\u003c\/strong\u003e: With a frequency range reaching 20 kHz and a response time under 15 μs, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edriver captures high-speed dynamic machinery transients. This capability allows for the early detection of imbalance, misalignment, or bearing instabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Contact Wear Prevention\u003c\/strong\u003e: Eddy current technology monitors the shaft displacement without physical friction. This eliminates mechanical wear and ensures the probe provides repeatable, long-term accuracy without the need for periodic sensor surface maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Noise Rejection\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edriver incorporates galvanic isolation between the probe and the monitoring system. This hardware barrier blocks electrical noise and ground loops from contaminating the vibration data, which is essential for stable monitoring in high-voltage grid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the CON021 with other probe series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edriver is highly versatile and works with several Emerson\/EPRO probe series, including the PR6422, PR6424, PR6425, PR6426, and PR6453. Always ensure the driver's calibration matches the specific probe tip size and cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the ATEX certification on the PR6423\/01C-030?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ATEX certification permits installation in potentially explosive atmospheres common in oil \u0026amp; gas and chemical processing. This ensures the probe does not act as an ignition source even in the event of a fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3.0m armored cable replaceable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable is integral to the probe head to maintain impedance matching. If the cable suffers damage, you must replace the entire probe assembly (\u003cstrong\u003ePR6423\/01C-030\u003c\/strong\u003e) to ensure measurement accuracy remains within factory specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43131258175578,"sku":"CON021+PR6423\/01C-030","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/328._459d209b-4189-43a6-8cfc-ec8aac3c44aa.jpg?v=1774507391"},{"product_id":"1c31161g02-ovation-westinghouse-rtd-sensor-interface","title":"1C31161G02 Ovation \/ Westinghouse RTD Sensor Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson Ovation 1C31161G02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision RTD (Resistance Temperature Detector) Input Personality Module within the Ovation™ Distributed Control System (DCS). This module specializes in acquiring low-level resistance signals from industrial sensors, such as Pt100 and Pt1000, and converting them into accurate digital temperature values for the controller. It provides the necessary excitation current and high-resolution A\/D conversion required for mission-critical thermal monitoring in turbines, boilers, and reactors. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring the measurement integrity needed for stable closed-loop process control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1C31161G02 utilizes advanced signal conditioning to maintain a typical accuracy of ±0.1°C across a wide industrial temperature spectrum.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1C31161G02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD Input \/ Personality Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100, Pt1000 (DIN Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–200°C to +850°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14-bit A\/D Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1°C (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50–60 SPS (Samples Per Second)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;500 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 x 33 x 160 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 kg – 0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Thermal Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module manages 16 independent RTD channels within a single Ovation slot. This high-density architecture significantly reduces the physical footprint in control cabinets, making it ideal for balance-of-plant (BOP) systems with extensive sensor arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Sensor Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1C31161G02 identifies open-circuit faults and sensor failures instantly. By reporting these diagnostics back to the Ovation HMI, it prevents the controller from executing logic based on \"frozen\" or erroneous data, enhancing overall system safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module effectively filters out 50\/60 Hz line noise and electromagnetic interference (EMI) typical of turbine decks. This ensures that the high-resolution A\/D conversion remains stable, even when sensitive RTD leads run near high-voltage power cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Cold-Junction Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile primarily an RTD interface, this \"Personality Module\" variant handles low-level current signals (±1 mA) and incorporates cold-junction compensation logic. This versatility allows engineers to adapt the module for specialized thermal feedback requirements beyond standard RTDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Excitation Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module delivers a precise, regulated excitation current to the sensors. This eliminates measurement drift caused by fluctuating power supplies, ensuring that your temperature readings remain consistent over years of continuous 24\/7 operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1C31161G02 support 3-wire and 4-wire RTD configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports standard industrial RTD wiring configurations to compensate for lead-wire resistance. For the highest accuracy in long-distance runs, we recommend 3-wire or 4-wire setups to ensure the lead resistance does not offset the temperature reading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for both Pt100 and Pt1000 sensors simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module hardware supports both types, you must configure the software parameters in the Ovation I\/O Builder to match the specific RTD type connected to each channel to ensure correct scaling and linearization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 50–60 SPS sampling rate benefit my process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis sampling rate provides a fast update time (under 500ms for all channels), which is essential for \"Sequence of Events\" (SOE) recording and fast-acting thermal protection interlocks in high-speed rotating machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1C31161G02 supports live replacement in an energized Ovation chassis. You can swap the module without powering down the I\/O rack, provided the system configuration and redundancy settings allow for a bumpless transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43136057344090,"sku":"1C31161G02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/370._7a9fdd41-b334-4225-a205-1048f8d5b7fa.jpg?v=1774581065"},{"product_id":"new-emerson-1c31224g01-process-monitoring-card","title":"New Emerson 1C31224G01 Process Monitoring Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson Ovation 1C31224G01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-fidelity Analog Input (AI) module designed for the Ovation™ Distributed Control System (DCS). It provides the essential interface for converting continuous analog signals from field instrumentation into precise digital data for process monitoring and closed-loop control. This module facilitates the accurate measurement of critical variables such as pressure, temperature, flow, and level. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring the signal integrity and real-time data flow required for mission-critical power generation and petrochemical operations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1C31224G01 utilizes a high-resolution architecture and multi-channel design to optimize cabinet density and measurement stability.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1C31224G01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input (AI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA, 0–5 V, or 0–10 V (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Resolution Precision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson Ovation DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvation Controller Backplane Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-System \u0026amp; Channel-to-Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time with Low Latency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to 85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Ovation Chassis Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Fidelity Data Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1C31224G01 converts raw field signals with ultra-low latency. This ensures that the Ovation controller receives the most current process data, allowing for tighter control loops and faster response to transient process conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial environments generate significant electromagnetic interference. This module incorporates built-in hardware filtering and high-resolution A\/D conversion to eliminate signal jitter, providing a clean data stream even when sensor cables run near high-voltage equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features robust channel-to-channel and channel-to-system isolation. This architecture prevents ground loops from distorting measurements and protects the sensitive DCS backplane from field-side electrical surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Self-Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated health monitoring logic constantly verifies the integrity of the input circuits and onboard electronics. The module reports fault detections and status updates to the DCS console in real-time, enabling proactive maintenance before a hardware failure affects production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular \"Bumpless\" Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for the standard Ovation I\/O rack, the 1C31224G01 allows for rapid installation and configuration. Its stable electronic design ensures that adding or replacing modules does not disrupt the accuracy of existing process monitoring points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific signal types does the 1C31224G01 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module hardware is versatile; it supports standard 4–20 mA current loops as well as 0–5 V and 0–10 V voltage signals. You define the specific input type through software configuration in the Ovation I\/O Builder to match your field transmitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older 1C31224 series module with the G01 version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1C31224G01 maintains backward compatibility with standard Ovation rack architectures. Replacing an older or failed unit with this brand-new G01 version provides updated component reliability while utilizing existing field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power for its 4-20mA loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module receives its primary operating power from the Ovation backplane. However, depending on your field wiring (2-wire vs. 4-wire), the 4-20mA loop may require external 24 VDC power, often distributed through the base assembly or a separate power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1C31224G01 suitable for hot-swap replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Like most modern Ovation I\/O modules, the 1C31224G01 supports online replacement. The system identifies and initializes the new module automatically once seated, though you should follow all site-specific safety and bypass protocols before performing live maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43139571089498,"sku":"1C31224G01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/371_e3222204-dbf7-4739-8cbe-e4166e65ac8c.jpg?v=1774591366"}],"url":"https:\/\/www.spareoil.com\/collections\/probes-sensors-transducer.oembed?page=19","provider":"SpareOil Automation","version":"1.0","type":"link"}