{"title":"Prosoft","description":"\u003cp\u003e\u003cspan class=\"citation-19 citation-end-19\"\u003eProsoft Technology specializes in connecting disparate automation systems.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e This collection features original in-rack communication modules and standalone gateways. We provide 100% genuine Prosoft components that enable seamless data exchange between PLC\/DCS platforms and various industrial protocols.\u003c\/p\u003e","products":[{"product_id":"mvi69-pdps-prosoft-mvi69-compactlogix-communication","title":"MVI69-PDPS | ProSoft MVI69 | CompactLogix Communication","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69-PDPS (MVI69-PDPS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized backplane-compatible communication interface designed by ProSoft Technology for the Allen-Bradley CompactLogix™ platform. This module allows a Rockwell Automation processor to function as a slave station on a Profibus DP network. It is an essential component for hybrid control architectures, enabling seamless data exchange between CompactLogix systems and Profibus-based Masters, such as Siemens S7 PLCs or various Distributed Control Systems (DCS). By offloading complex protocol timing to the module hardware, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69-PDPS (MVI69-PDPS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that the main CPU’s scan time remains unaffected by network traffic.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69-PDPS (MVI69-PDPS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoccupies a single slot in any 1769-based rack and operates as a standard I\/O module within the Logix Designer environment.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProSoft Technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI69-PDPS (MVI69-PDPS)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley CompactLogix (1769 L2\/L3\/L4 series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProfibus DP-V0 Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaud Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9.6 kbps to 12 Mbps (Hardware auto-detect)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Data:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 244 bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Data:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 244 bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Database:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e400 registers (16-bit words)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e800 mA @ 5 VDC; 0 mA @ 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ45 (RS-232) utilizing the ProSoft Configuration Builder (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500V optical isolation between Profibus network and backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Status Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModule Status, Application Status, Backplane Activity, Serial Activity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 1769 Single-slot width\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% (Non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":42870831579226,"sku":"MVI69-PDPS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/431._8b991b88-dd25-494a-9671-a65213fd965c.jpg?v=1773106541"},{"product_id":"prosoft-5301-mbp-dfcm-modbus-plus-to-df1-gateway","title":"ProSoft 5301-MBP-DFCM Modbus Plus to DF1 Gateway","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft 5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance bridge between Schneider Electric\/Modicon Modbus Plus networks and Allen-Bradley DF1 serial devices. This gateway enables bi-directional data exchange, allowing legacy SLC 500 or MicroLogix controllers to communicate directly with Modbus Plus-based SCADA systems and PLCs. By mapping DF1 data into Modbus Plus register space, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates phased system upgrades and cross-platform integration without requiring extensive code rewrites. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment to ensure maximum network uptime and data integrity in your industrial architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProSoft Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus Plus ↔ DF1 Protocol Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModbus Plus Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × DB9 Female (Global Data \u0026amp; Peer-to-Peer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModbus Plus Addressing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSoftware selectable: 1–64\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDF1 Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 4 Configurable Serial Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232, RS-422, or RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDF1 Master or Slave, Half\/Full Duplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptical isolation on all communication paths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLEDs for Power, Link Status, and Port Activity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Port Scalability\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures up to four independent serial ports. This allows a single gateway to act as a central data concentrator, polling multiple DF1 slaves simultaneously and consolidating their data onto the Modbus Plus backbone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Signal Isolation\u003c\/strong\u003e: ProSoft incorporates specialized optical isolation on all communication ports. This hardware barrier prevents ground loops and electrical surges—common in large-scale manufacturing plants—from damaging the connected PLC hardware or corrupting data packets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBi-Directional Determinism\u003c\/strong\u003e: The gateway manages complex data mapping in real-time. Whether reading register values from a Modicon PLC or writing control commands to an Allen-Bradley drive, the module maintains strict timing to ensure process stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Configuration\u003c\/strong\u003e: Engineers utilize ProSoft’s Windows-based software to define data maps. This eliminates the need for complex ladder logic programming within the controllers, as the gateway handles all protocol translation and byte-swapping internally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5301-MBP-DFCM integrate with both RS-232 and RS-485 devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The configurable DF1 ports support RS-232, RS-422, and RS-485 physical layers. You can tailor each port to match the specific electrical requirements of your field instrumentation or legacy controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the Modbus Plus port require specialized drivers for the PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module appears as a standard node on the Modbus Plus network (Addressing 1–64). Standard Modicon PLCs use MSTR blocks or Global Data configurations to interact with the gateway exactly as they would with any other Modbus Plus peer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure data integrity over long serial cable runs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor RS-485 or RS-422 configurations, ensure you install proper termination resistors at the end of the network segments. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5301-MBP-DFCM\u003c\/strong\u003e's isolated ports already provide significant protection against common-mode noise found in long-distance industrial wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":42870831743066,"sku":"5301-MBP-DFCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/1._f87f8cf7-9d85-41a0-9a32-81fcbfc23930.jpg?v=1774503534"},{"product_id":"5204-dfnt-pdpm-prosoft-gateway-new-original-stock","title":"5204-DFNT-PDPM ProSoft Gateway | New \u0026 Original Stock","description":"\u003ch2\u003eProSoft 5204-DFNT-PDPM ProLinx Protocol Master Gateway\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed bi-directional data exchange between EtherNet\/IP and PROFIBUS DP networks, the \u003cstrong\u003eProSoft 5204-DFNT-PDPM\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eProSoft 5204-DFNT-PDPMV1\u003c\/strong\u003e Protocol Master Gateway, provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5204-DFNT-PDPM (Alternative Part #: 5204-DFNT-PDPMV1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.90 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard ProLinx compact housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial rating (contact manufacturer for exact limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (18 to 32 VDC allowable range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps RJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x PROFIBUS DP Master DB9 female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mm screwdriver blade required for GND\/Power terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVer. 2.45 (OS 2.41)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Network Performance\u003c\/h3\u003e\n\u003cp\u003eThe gateway architecture optimizes protocol conversion latencies through dual-port internal memory mapping. The EtherNet\/IP interface utilizes up to 5 independent TCP server sockets, executing PCCC on CIP for explicit messaging (Services 0x4C and 0x4D). Data table mapping is structured with a fixed origin at N10, processing data packets up to 1000 words.\u003c\/p\u003e\n\u003cp\u003eSimultaneously, the PROFIBUS DP Master engine executes full physical and link layer management per IEC 61158. The DB9 interface supports transmission velocities up to 12 Mbps, maintaining cyclic IO scanning and DPV1 extended diagnostic messaging for up to 125 downstream slave devices. Internal propagation delay between the EtherNet\/IP driver and the PROFIBUS master stack is governed by the backplane polling cycle, ensuring deterministic updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this gateway support hot-swapping or live extraction under load?\u003c\/strong\u003e A: No. The DC power terminal blocks and communication cables must be isolated before removing the module from the DIN-rail to prevent electrical arcing, backplane current spikes, or data corruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the EtherNet\/IP interface handle simultaneous read and write requests from multiple PLCs?\u003c\/strong\u003e A: Yes. The module features 5 independent TCP server sockets, allowing concurrent connections from multiple Rockwell Automation controllers (ControlLogix, CompactLogix, or SLC). However, aggregating cross-communication within the internal 1000-word memory layout requires strict index mapping to prevent data collision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if a PROFIBUS slave device drops offline or encounters a fault?\u003c\/strong\u003e A: The master engine utilizes the DPV1 specification to capture extended diagnostics and alarms. This status data is mapped into the internal register structure and mirrored to the EtherNet\/IP host controller via CIP services, allowing the master PLC to detect individual slave dropouts within one network cycle.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Orientation:\u003c\/strong\u003e Install the module vertically on a grounded, 35 mm steel DIN-rail. Ensure a minimum clearance of 50 mm above and below the unit to allow natural convective thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower and Grounding Architecture:\u003c\/strong\u003e Connect a regulated 24 VDC external power supply to the screw terminals using a 2.5 mm screwdriver blade. Connect the dedicated GND terminal directly to the central equipment rack ground bus using a low-impedance copper conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Requirements:\u003c\/strong\u003e Use double-shielded, twisted-pair Type A PROFIBUS cable for all serial runs. Ensure the DB9 connector outer metal shell makes continuous 360-degree contact with the cable shield to suppress high-frequency EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e The final slave device on the PROFIBUS segment and the master gateway (if positioned at the physical end of the bus topology) must have active termination enabled via the standard DB9 terminating resistor switch.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474821152858,"sku":"5204-DFNT-PDPM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/5._f7ab789e-d5e1-4721-b54d-24bba76a2528.jpg?v=1781053054"},{"product_id":"mvi56e-mcmxt-prosoft-controllogix-datasheet-technical-manual","title":"MVI56E-MCMXT ProSoft ControlLogix Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eProSoft MVI56E-MCMXT ControlLogix Modbus Communication Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56E-MCMXT\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI56E-MCMXT\u003c\/strong\u003e Modbus Master\/Slave Enhanced Network Interface Module, operates as a dedicated hardware component for multi-port serial data exchange within Allen-Bradley ControlLogix backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI56E-MCMXT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.36 kg (3.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-slot ControlLogix module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane powered, 800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Occupancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Type Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal or Remote rack placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 user-definable 16-bit registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x independent isolated Modbus RTU\/ASCII ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 baud to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone, Even, Odd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStop Bits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTS Timing Delays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 65535 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-character scrolling alphanumeric LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Ethernet port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Serial Performance\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with ControlLogix processors via localized backplane bus communication, converting industrial serial data into standard I\/O data tables. Operating as a Modbus Master, each independent port handles up to 100 commands, executing binary RTU mode with CRC-16 error checking or ASCII mode with LRC error checking.\u003c\/p\u003e\n\u003cp\u003eInternal database mapping allocates up to 5,000 registers for slave configuration, maintaining low protocol conversion latencies across asynchronous serial networks. Hardware-level physical layer isolation protects the memory registers from common-mode line noise, and user-definable RTS delays prevent packet collisions on RS-485 multi-drop loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI56E-MCMXT support Remove and Insert Under Power (RIUP) operations?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The module hardware is fully compliant with 1756 backplane hot-swap standards, allowing extraction and insertion while the chassis is powered. However, active Modbus serial polling on the sub-networks will terminate instantly upon module removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the \"XT\" suffix in this module variant?\u003c\/strong\u003e \u003cstrong\u003eA: The XT designation\u003c\/strong\u003e specifies that the module is equipped with conformal coating to defend internal components against caustic atmospheric environments. It is designed to match the mechanical and electrical specifications of the Allen-Bradley ControlLogix-XT control platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the internal database configuration be retrieved or updated remotely over the Ethernet network?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The module is CIPconnect enabled, which permits full engineering access, database modifications, and diagnostics via bridged 1756-ENBT or similar network interface modules over an EtherNet\/IP topology.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment and Insertion:\u003c\/strong\u003e Align the circuit board with the top and bottom guides of a single slot in the 1756 backplane. Press firmly until the module latches secure it into the chassis connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding Protocols:\u003c\/strong\u003e Ensure that the ControlLogix chassis is bonded to the industrial enclosure ground bus using a low-impedance conductor. Serial communication cables must utilize shielded twisted-pair wire, with the shield terminated at one point only to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Segment Node Limits:\u003c\/strong\u003e When configuring the serial ports as a Modbus Master, respect the physical limitation of up to 247 slave node addresses per port. Ensure proper end-of-line termination resistors (typically 120 ohms) are applied to RS-485 network segments to maintain signal integrity at higher baud rates up to 115.2 kbps.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474880626778,"sku":"MVI56E-MCMXT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/6._9801f77a-5122-424d-82d3-f2f778cb97c3.jpg?v=1781053401"},{"product_id":"prosoft-mvi56-hart-hart-master-module-new-original-stock","title":"ProSoft MVI56-HART HART Master Module | New \u0026 Original Stock","description":"\u003ch2\u003eProSoft MVI56-HART HART Master Multi-drop Network Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-HART\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI56-HART\u003c\/strong\u003e HART Master Multi-drop Network Interface Module, operates as a dedicated hardware component for multi-channel process instrument data acquisition within Allen-Bradley ControlLogix platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI56-HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.31 kg (0.68 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 cm x 9.3 cm x 13.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial rating (contact manufacturer for exact limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane powered, 800 mA at 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Occupancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Type Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756 ControlLogix backplane compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 independent HART master ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 15 devices per channel (60 total devices max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 registers maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; HART Loop Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe interface module executes cyclic data transfer via the 1756 backplane using standard ladder logic and pre-defined data objects, appearing directly to the ControlLogix processor as a native Input\/Output module. Each of the four channels features an independent 4-20 mA HART loop protocol engine, allowing concurrent multi-drop configurations.\u003c\/p\u003e\n\u003cp\u003eThe internal database stores digital primary variable data, secondary variables, and device status registers. By managing master protocol commands autonomously, the module handles up to 5000 internal registers without overloading the main PLC processor's scanning cycle. It maintains compatibility with HART field transmitters across more than 170 instrument models from over 105 manufacturers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI56-HART support online hardware replacement while the ControlLogix chassis is powered?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The module is designed to slide directly into any standard 1756 chassis slot and supports hot-swapping under backplane power. However, pulling the module while active will instantly break the 4-20 mA digital instrumentation loop communication for all 60 connected field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a single channel mix different types of instruments, such as flow meters and pressure transmitters?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e Because each channel acts as a true HART master in multi-drop mode, you can connect up to 15 unique, parallel-addressed field instruments to a single channel, provided each device is assigned a distinct polling address between 1 and 15.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the 4-20 mA analog signal loop power handled by this module?\u003c\/strong\u003e \u003cstrong\u003eA: The module does not supply loop power\u003c\/strong\u003e directly to the field instruments. External 24 VDC process loop power supplies must be integrated into the field wiring architecture to power the connected field transmitters.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e Ensure the 1756 ControlLogix chassis is mounted securely to a grounded subpanel. The ground clips on the rear of the module must make firm, clean physical contact with the chassis rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Separation:\u003c\/strong\u003e Always route the 4-20 mA HART signal cables through dedicated low-voltage wire ways. Keep these cables separated from high-voltage AC motor lines or variable frequency drive (VFD) output cables to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-drop Loop Impedance:\u003c\/strong\u003e To guarantee clean digital FSK (Frequency Shift Keying) signal modulation superimposed on the analog line, ensure that each loop contains a minimum loop resistance of 250 ohms between the external power supply and the module terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474893471834,"sku":"MVI56-HART","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/7_67cb8596-9d68-4a10-ac26-6f6dac2a4aae.jpg?v=1781053638"},{"product_id":"mvi56e-mnetc-prosoft-controllogix-series-datasheet-technical-manual","title":"MVI56E-MNETC ProSoft ControlLogix Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eProSoft MVI56E-MNETC ControlLogix Modbus TCP\/IP Enhanced Communication Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-throughput data exchange between ControlLogix processors and Modbus TCP\/IP networks, the \u003cstrong\u003eProSoft MVI56E-MNETC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e Enhanced Network Interface Module, provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI56E-MNETC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology (Belden ProSoft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 cm x 14.0 cm x 14.5 cm (Single-slot occupancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C (-40 deg F to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane powered, 800 mA @ 5 VDC \/ 3 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 10\/100 Mbps base-T RJ45 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 words (16-bit registers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTariff Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Network Performance\u003c\/h3\u003e\n\u003cp\u003eThe module executes concurrent Client and Server operations across local or remote 1756 ControlLogix backplanes. The network interface supports up to 30 simultaneous Client connections and processes up to 100 independent Client commands, transmitting Modbus packets mapped straight into the 10,000-word internal database memory.\u003c\/p\u003e\n\u003cp\u003eIntegrating dual 10\/100 Mbps Ethernet ports allows network segmentation or device-level architecture partitioning, isolating configuration tracking from active automation control. The internal execution engine handles protocol conversion latencies through optimized data block transfers, converting Modbus TCP\/IP registers directly into native processor I\/O data tables.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI56E-MNETC module support Remove and Insert Under Power (RIUP) actions?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The internal hardware components match standard 1756 chassis bus parameters, enabling hot-swap extraction and insertion while the slot is energized. However, disconnecting the module drops all active Modbus TCP\/IP Client\/Server sockets instantly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the dual Ethernet ports be configured for a redundant Ring topology?\u003c\/strong\u003e \u003cstrong\u003eA: No.\u003c\/strong\u003e The two RJ45 ports provide independent IP routing structures designed for network segmentation (e.g., separating plant network access from local instrumentation loops). They do not serve as an integrated Device Level Ring (DLR) switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are configurations preserved if the module loses power?\u003c\/strong\u003e \u003cstrong\u003eA: Configuration variables\u003c\/strong\u003e and command maps are stored in non-volatile flash memory inside the module. Backplane parameter setups and the Add-On Instruction (AOI) loaded in the RSLogix 5000 v16+ runtime automatically restore mapping tables during startup.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Slide the module firmly into any single available slot of a grounded 1756 ControlLogix chassis. Verify the mechanical locking tabs at the top and bottom snap fully into place to maintain physical backplane bus contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded Network Cabling:\u003c\/strong\u003e Utilize Category 5e or higher shielded twisted-pair (STP) Ethernet cabling for all network lines. Ground the cable shields at the switch infrastructure to isolate the internal communications logic from industrial electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Address Allocation:\u003c\/strong\u003e Configure distinct static IP addresses for each utilized Ethernet port via the ProSoft Configuration Builder utility. Avoid assigning matching subnets to both ports to prevent local routing tables from conflicting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474901762138,"sku":"MVI56E-MNETC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/8._9ef3d608-a962-4b6b-be37-0755ca6d09df.jpg?v=1781053975"},{"product_id":"mvi69-mcm-prosoft-compactlogix-series-datasheet-technical-manual","title":"MVI69-MCM ProSoft CompactLogix Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eProSoft MVI69-MCM CompactLogix Modbus Communication Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI69-MCM\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI69-MCM\u003c\/strong\u003e Modbus Master\/Slave Network Interface Module, operates as a dedicated hardware component for multi-port serial data exchange within Rockwell Automation CompactLogix platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI69-MCM (Spare Model: MVI69MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology (Belden ProSoft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg (0.35 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 cm x 8.7 cm x 13.2 cm (Standard 1769 Single-slot Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial rating (contact manufacturer for exact limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane powered, 800 mA max @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Occupancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation CompactLogix (1769 backplane architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Transfer Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronized ladder logic data blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 baud to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNode Address Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 247 per port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTariff Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Serial Networking\u003c\/h3\u003e\n\u003cp\u003eThe module bridges the local 1769 backplane to standard Modbus networks, running up to two independent serial ports concurrently. Each interface is individually configurable to execute as either a Modbus Master or Modbus Slave using RTU or ASCII transmission formats.\u003c\/p\u003e\n\u003cp\u003eData transfers between the module memory registers and the CompactLogix processor are managed through small block transfers embedded in the asynchronous ladder logic scanning cycle. This internal arbitration system governs data mapping directly to user-defined arrays, ensuring that serial protocol conversion latencies do not introduce jitter into the time-deterministic operations of the main PLC backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the MVI69-MCM module be removed or inserted into the 1769 chassis while backplane power is active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: No.\u003c\/strong\u003e Unlike larger 1756 architectures, the 1769 CompactLogix backplane system does not support Remove and Insert Under Power (RIUP) actions. Removing the module while the system is energized will trigger a fatal backplane bus fault on the controller and risk permanent electrical damage to the interface circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the maximum current consumption bounded under full dual-port serial load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: The maximum internal power draw\u003c\/strong\u003e from the 1769 backplane is strictly limited to 800 mA at 5 VDC. External serial line loads, termination resistors, or transient voltage suppression states across both active lines are factored into this threshold, requiring correct sizing of the 1769 power supply budget.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are network node configurations maintained if the module encounters a total power loss scenario?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: All protocol properties\u003c\/strong\u003e, mapping schemes, and port configuration matrices are permanently written to non-volatile onboard flash memory. Upon restoration of the 5 VDC backplane supply, the gateway initializes automatically from the stored profile without requiring a configuration download from the processor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Attachment and Bus Interlocking:\u003c\/strong\u003e Power down the CompactLogix system prior to installation. Slide the module onto the standard 35 mm DIN-rail alongside adjacent 1769 components, ensuring the integrated tongue-and-groove guides align smoothly. Close the bus levers to firmly lock the backplane connectors together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding Infrastructure:\u003c\/strong\u003e Connect all serial communication networks using high-quality twisted-pair cabling. Ground the cable drain wire at a single point near the enclosure ground terminal block to suppress high-frequency electromagnetic field interference across the asynchronous serial paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-485 Segment Termination:\u003c\/strong\u003e For networks operating at long physical distances or high baud rates up to 115.2 kbps, ensure a matching 120-ohm end-of-line resistor is attached across the balanced Tx\/Rx lines at the terminal limits of the physical segment to prevent signal wave reflection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474910347354,"sku":"MVI69-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/9._45566b0e-633c-4655-96a5-90b76bd6e706.jpg?v=1781054377"},{"product_id":"mvi69e-mbtcp-prosoft-modbus-module-new-original-stock","title":"MVI69E-MBTCP ProSoft Modbus Module | New \u0026 Original Stock","description":"\u003ch2\u003eProSoft MVI69E-MBTCP CompactLogix Modbus TCP\/IP Enhanced Communication Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI69E-MBTCP\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI69E-MBTCP\u003c\/strong\u003e Modbus TCP\/IP Enhanced Communication Module, operates as a dedicated hardware component for multi-client\/server data interface management within Allen-Bradley CompactLogix platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI69E-MBTCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (1.06 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.8 cm x 21.6 cm x 8.1 cm (7.0 in x 8.5 in x 3.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane powered, 5 VDC slot draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps base-T RJ45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Layer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Enhanced Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTariff Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8517620050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModbus TCP\/IP Deterministic Networks \u0026amp; Data Transfer\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with the CompactLogix processor over the local 1769 backplane via scheduled I\/O data blocks. The integrated single 10\/100 Mbps Ethernet port runs simultaneous Client and Server connections, translating Modbus TCP\/IP data packets directly into the host controller memory arrays.\u003c\/p\u003e\n\u003cp\u003eBy mapping internal data registers without intermediate serialization hardware, the communications engine lowers system propagation delays across Ethernet networks. The execution pipeline utilizes pre-allocated data tables within the module memory, enabling synchronous data block delivery across the backplane bus without interrupting deterministic PLC logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI69E-MBTCP support hot-swapping or Remove and Insert Under Power (RIUP) functions?\u003c\/strong\u003e \u003cstrong\u003eA: No.\u003c\/strong\u003e The 1769 backplane architecture does not feature isolated pin connections for live-swapping. The CompactLogix system must be completely powered down before extracting or inserting this module to avoid electrical breakdown or processor fault states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the single Ethernet port handle monitoring diagnostics and runtime control data concurrently?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The 10\/100 Mbps RJ45 interface handles both simultaneous Modbus TCP\/IP Client\/Server process communication and configuration polling from engineering software utilities on the same subnetwork.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the mapping layout protected against volatilization during a total power disruption?\u003c\/strong\u003e \u003cstrong\u003eA: All register configurations\u003c\/strong\u003e, command lists, and communication metrics are written directly to internal non-volatile flash memory, allowing automated state recovery upon backplane power restoration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion Constraints:\u003c\/strong\u003e Ensure the rack power supply is completely switched off. Align the integrated side guides of the module with the adjacent 1769 module slots and lock the bus levers to establish solid mechanical and electrical continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding Standards:\u003c\/strong\u003e Use standard Category 5e or higher shielded twisted-pair (STP) lines for the Ethernet network. Ensure the shield terminates at the network switch infrastructure to isolate internal communication traces from external electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Configuration Routines:\u003c\/strong\u003e Allocate a static IP address to the module matching the plant subnet. Avoid DHCP address schemes for runtime controllers to ensure reliable connectivity with downstream Modbus servers.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474920308826,"sku":"MVI69E-MBTCP","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/10.1_a1cb1726-4259-4800-8a74-04bc25f6a4dc.jpg?v=1781054625"},{"product_id":"mvi56e-mnet-prosoft-modbus-tcp-module-new-original-stock","title":"MVI56E-MNET ProSoft Modbus TCP Module | New \u0026 Original Stock","description":"\u003ch2\u003eProSoft MVI56E-MNET ControlLogix Modbus TCP\/IP Enhanced Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56E-MNET\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI56E-MNET\u003c\/strong\u003e Enhanced Network Interface Module, operates as a dedicated hardware component for Modbus TCP\/IP Client\/Server data conversion within Allen-Bradley ControlLogix platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI56E-MNET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology (Belden ProSoft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg (0.57 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 cm x 14.7 cm x 14.0 cm (1.3 in x 5.8 in x 5.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C (-40 deg F to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane powered, 800 mA at 5 VDC \/ 3 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps Base-T RJ45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 words (16-bit registers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery Status (ERR), Application Status (APP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder (PCB) \/ CIPconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix V 10 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTariff Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8537101190 (also classified under 8517620050)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Network Performance\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with standard 1756 ControlLogix backplanes, running concurrent Modbus TCP\/IP Client and Server software stacks via a single RJ45 interface. The communication processor routes network data packages straight into an internal database containing 5000 16-bit registers.\u003c\/p\u003e\n\u003cp\u003eBy eliminating standalone serial-to-ethernet bridges, the hardware achieves low protocol conversion latencies. It integrates into the host controller memory maps using standard Add-On Instructions (AOI) or sample ladder logic. The internal memory layout matches legacy MVI56 parameter profiles, enabling backward compatibility for drop-in physical replacement without requiring complete application code overhauls.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI56E-MNET module support Remove and Insert Under Power (RIUP) actions?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The electrical interface is compliant with 1756 ControlLogix chassis hot-swap standards, allowing live module replacement while backplane power is active. However, removing the module instantly drops all active Modbus TCP\/IP sockets and halts asynchronous backplane block transfers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is configuration data extracted or updated on the module over the plant network?\u003c\/strong\u003e \u003cstrong\u003eA: The module supports CIPconnect\u003c\/strong\u003e, which enables ProSoft Configuration Builder software running on a network PC to bridge through the ControlLogix processor. This permits remote configuration downloads, configuration uploads, and diagnostic access without requiring a direct connection to the module's local port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module maintain configuration variables if the chassis experiences a total power outage?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e Configuration parameters, network tables, and operational profiles are saved directly to internal non-volatile memory arrays. Onboard battery status is actively tracked by the ERR LED to warn of physical cell degradation affecting volatile register backup.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Installation and Interlocking:\u003c\/strong\u003e Power down the system if regional safety rules require it, though hot-swapping is supported. Slide the module straight into any unreserved slot of a grounded 1756 ControlLogix chassis until the top and bottom retention tabs click into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Infrastructure Shielding:\u003c\/strong\u003e Connect the RJ45 port to the local automation network using high-quality Category 5e or higher shielded twisted-pair (STP) copper cabling. Ensure the cable shield terminates at the network switch housing to isolate the signaling path from common industrial electrical transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e The 1756 chassis housing must be low-impedance bonded to the main enclosure ground panel. Verify that the chassis spring clips are clean and unpainted to maintain good electrical continuity with the module casing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474925420634,"sku":"MVI56E-MNET","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/11._001e546c-4d60-4dd2-8dfe-224b38652eb0.jpg?v=1781054844"},{"product_id":"prosoft-mvi46-mcmslc-500-series-datasheet-technical-manual","title":"ProSoft MVI46-MCMSLC 500 Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eProSoft MVI46-MCM SLC Modbus Communication Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI46-MCM\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI46MCM\u003c\/strong\u003e Modbus Master\/Slave Interface Module, operates as a dedicated hardware component for asynchronous serial data conversion within Allen-Bradley SLC 500 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI46-MCM (Spare Model: MVI46MCM 1700095)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology (Belden ProSoft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg (0.50 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 15.2 cm x 12.7 cm (1.0 in x 6.0 in x 5.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C (-40 deg F to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g from 10 to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Occupancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1746 chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 mA @ 5 VDC (also rated up to 5.1 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Memory Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000-word register space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Backplane Arbitration\u003c\/h3\u003e\n\u003cp\u003eThe module functions as a local input\/output card interface between the Modbus serial network topology and the Rockwell Automation 1746 backplane. Data allocation within the hardware architecture uses an integrated 5000-word register memory segment to hold data values transferred between the foreign devices and the SLC processor.\u003c\/p\u003e\n\u003cp\u003eThe physical transmission of bits across the serial network link runs asynchronously from the backplane transfer cycle. This dual-port decoupling controls protocol conversion latencies, protecting the main SLC ladder program scan time from network polling delays. The configuration supports both Modbus Master and Modbus Slave roles to manage foreign data concentrator functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI46-MCM module support hot-swapping or Remove and Insert Under Power (RIUP) actions within the 1746 rack?\u003c\/strong\u003e \u003cstrong\u003eA: No.\u003c\/strong\u003e The 1746 chassis and backplane architecture do not permit online component extraction. System power must be isolated before sliding the module into or out of the slot to prevent physical circuit breakdown or hardware failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is data synchronized between the module's 5000-word register space and the SLC processor?\u003c\/strong\u003e \u003cstrong\u003eA: Data routing uses M0 and M1 files\u003c\/strong\u003e driven by the SLC logic application. Because the memory block exchange runs asynchronously to the serial protocol loop, user logic handles the data block pagination without stalling the network transmission lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum current load drawn from the 1746 chassis power supply?\u003c\/strong\u003e \u003cstrong\u003eA: The module demands 800 mA\u003c\/strong\u003e directly from the 5 VDC (up to 5.1 VDC) internal backplane rail. This current draw must be factored into the overall power budget calculations of the local 1746 power supply unit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion Restrictions:\u003c\/strong\u003e De-energize the 1746 chassis fully. Align the printed circuit board card guides into the target slot tracks of the rack and apply even pressure until the top and bottom plastic retaining tabs snap lock into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Wiring Shielding:\u003c\/strong\u003e Route all serial communication lines through dedicated low-voltage wire conduits. Use high-quality shielded twisted-pair cables, and ensure the drain wire terminates at a single low-impedance grounding bar within the control panel to block industrial electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Termination Requirements:\u003c\/strong\u003e For long physical cable runs or configurations experiencing high signal reflection, connect a 120-ohm matching end-of-line resistor across the differential RX\/TX lines on the termination blocks of the final network nodes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474962972762,"sku":"MVI46-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/12.1_54754087-9129-4333-b69e-4baa7bdf346e.jpg?v=1781055054"},{"product_id":"mvi56-gsc-prosoft-controllogix-series-datasheet-technical-manual","title":"MVI56-GSC ProSoft ControlLogix Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eProSoft MVI56-GSC Generic ASCII Serial Communication Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-GSC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI56GSC\u003c\/strong\u003e Generic ASCII Serial Communication Module, operates as a dedicated hardware component for ASCII serial character processing within Allen-Bradley ControlLogix backplane platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI56-GSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 15.2 cm x 12.7 cm (1.0 in x 6.0 in x 5.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane powered, 800 mA max @ 5 VDC \/ 3 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Occupancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x independent isolated serial channels (RS-232\/422\/485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneric ASCII raw character stream transmit\/receive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTariff Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8517620050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Serial Execution\u003c\/h3\u003e\n\u003cp\u003eThe module serves as a bidirectional raw character pipeline between the control processor and peripheral serial hardware. Data packets are read from and written to the module memory registers via asynchronous backplane block transfers managed through the host controller ladder logic.\u003c\/p\u003e\n\u003cp\u003eInternal microprocessing paths optimize protocol conversion latencies by buffering incoming character streams independently per port prior to backplane encapsulation. This hardware-level separation limits internal loop transit delays, preventing byte stream serialization bottlenecks during high-frequency barcode transmissions or weighing matrix processing cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI56-GSC support Remove and Insert Under Power (RIUP) actions?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The module's mechanical interface complies with standard 1756 ControlLogix backplane design, allowing hot-swapping while the chassis is live. However, live extraction immediately terminates raw serial buffer processing and results in lost data characters on active asynchronous links.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the two onboard serial channels be configured for different physical layer standards simultaneously?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e Port 1 and Port 2 are completely independent electrical circuits. Hardware jumpers on the module motherboard permit one channel to be configured for RS-232 point-to-point signaling while the alternate channel executes on an RS-485 or RS-422 multi-drop network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the raw character buffer managed when a packet exceeds the backplane block size allocation?\u003c\/strong\u003e \u003cstrong\u003eA: The module firmware parses data\u003c\/strong\u003e using defined termination characters or packet byte timeouts. When an incoming data stream exceeds a single backplane transfer block, the module partitions the characters across consecutive data blocks, utilizing internal pointers to maintain original payload order for the PLC logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment Constraints:\u003c\/strong\u003e Ensure the 1756 ControlLogix chassis is adequately bonded to earth ground. Align the module card edges with the designated slot guides and press firmly until both the top and bottom extraction tabs snap lock onto the chassis rim.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Signal Grounding and Shielding:\u003c\/strong\u003e Install raw serial runs utilizing high-quality shielded cables. Terminate the drain wire exclusively at the enclosure grounding bus bar to prevent high-frequency common-mode noise propagation from distorting the differential RS-485\/422 data streams.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination of Multidrop Cables:\u003c\/strong\u003e When deploying the module over an RS-485 or RS-422 bus layout, confirm that appropriate 120-ohm end-of-line resistors are fixed across the rx\/tx terminal pins of the most distant physical nodes to avoid wave reflections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43474993021018,"sku":"MVI56-GSC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/13._d050e589-9937-4532-9b9e-acf08bf49a54.jpg?v=1781055353"},{"product_id":"prosoft-mvi56-gec-ethernet-module-new-original-stock","title":"ProSoft MVI56-GEC Ethernet Module | New \u0026 Original Stock","description":"\u003ch2\u003eProSoft MVI56-GEC Ethernet Communications Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft MVI56-GSC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMVI56-GEC\u003c\/strong\u003e Generic ASCII Ethernet Communications Interface Module, serves as the primary \u003cstrong\u003eMVI56\u003c\/strong\u003e interface module utilized to execute bidirectional raw ASCII data transfers over Ethernet networks across Allen-Bradley ControlLogix platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMVI56-GEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (0.62 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 cm x 14.7 cm x 8.9 cm (1.7 in x 5.8 in x 3.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane powered, 800 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V optical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Placement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal or Remote rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Base-T RJ45 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232 serial configuration port (CFG, RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 baud to 115,200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Transfer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLadder Logic block transfers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Data Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with the ControlLogix processor across the 1756 backplane using scheduled block transfers governed by the controller's asynchronous ladder logic runtime. By isolating raw ASCII TCP\/IP encapsulation tasks onto an independent onboard communication processor, the unit preserves the master PLC CPU processing bandwidth.\u003c\/p\u003e\n\u003cp\u003eThe 500 V optical isolation protection layer guards internal backplane logic components from field-side electrical transients encountered on the 10\/100 Base-T network infrastructure. Serial character streams are buffered locally, preventing data overflow and packet degradation under peak network data rates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI56-GEC module support Remove and Insert Under Power (RIUP) operations?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e The module electrical interface satisfies standard 1756 chassis bus specifications, allowing hot-swap module replacement while the backplane is energized. Extraction will immediately terminate active Ethernet sockets and halt asynchronous logic data transfers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the RS-232 configuration port (CFG) be used for runtime ASCII communication?\u003c\/strong\u003e \u003cstrong\u003eA: No.\u003c\/strong\u003e The dedicated RJ45 RS-232 serial port is strictly limited to terminal diagnostics, system configuration setup, and firmware flashing via the ProSoft Configuration Builder software utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the impact on data packet integrity if the ladder logic scan time is slower than the incoming network data velocity?\u003c\/strong\u003e \u003cstrong\u003eA: The module contains internal FIFO ring buffers\u003c\/strong\u003e to store incoming ASCII character streams. If the backplane block transfer rate fails to pull data rapidly enough, the local buffer prevents character drops until its capacity is exceeded, at which point an overrun error bit is set in the module status block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment and Ingress Protection:\u003c\/strong\u003e Power down the ControlLogix system prior to insertion if required by plant safety standards. Insert the single-slot module into the 1756 chassis along the designated alignment guides until the upper and lower locking tabs click securely to the rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Infrastructure Shielding:\u003c\/strong\u003e Connect the 10\/100 Base-T interface using high-quality Category 5e or superior shielded twisted-pair (STP) copper cabling. Ground the cable shield solely at the network switch enclosure to prevent common-mode ground currents from looping through the module chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Diagnostic Connection:\u003c\/strong\u003e For initial configuration via the CFG port, utilize an RJ45 to DB9 adapter cable wired for standard null-modem serial execution, matching the communication velocity constraints of the host engineering station.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43475000459354,"sku":"MVI56-GEC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/14._810bfc8f-5320-402c-9628-0cfb49e83a2e.jpg?v=1781055586"},{"product_id":"5201-dfnt-mcm-prosoft-prolinx-datasheet-technical-manual","title":"5201-DFNT-MCM ProSoft ProLinx Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eProSoft 5201-DFNT-MCM ProLinx Protocol Gateway\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft 5201-DFNT-MCM\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e5201-DFNT-MCM\u003c\/strong\u003e EtherNet\/IP to Modbus Master\/Slave Gateway, serves as the primary \u003cstrong\u003e5201\u003c\/strong\u003e ProLinx standalone gateway utilized to execute high-speed protocol conversion across industrial network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5201-DFNT-MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.44 kg (0.97 lbs) \/ Net Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 cm x 13.5 cm x 13.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 50 deg C (-4 deg F to 122 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C (-40 deg F to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (50\/60 Hz internal filter baseline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA max @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps RJ45 connection port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x independent isolated channels (RS-232, RS-422, or RS-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 baud to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTariff Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion Latencies \u0026amp; Network Performance\u003c\/h3\u003e\n\u003cp\u003eThe standalone gateway houses a hardware conversion engine designed to map EtherNet\/IP commands straight into Modbus RTU or ASCII memory blocks. The EtherNet\/IP driver operates with 5 independent TCP server sockets, supporting explicit messaging via PCCC on CIP (Services 0x4C and 0x4D) with data lengths up to 125 words per read\/write cycle. Data table allocation starts at a fixed register entry at N10, provisioning sizes of 100 or 1000 words.\u003c\/p\u003e\n\u003cp\u003eOn the serial segment, the two configuration ports act independently as Modbus Master or Slave nodes, executing up to 100 commands per port across a maximum of 5000 Modbus registers. Internal memory mapping optimizes protocol conversion latencies, enabling asynchronous data transfer between EtherNet\/IP host controllers and downstream Modbus fields without delaying the primary network loop execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 5201-DFNT-MCM be extracted from the DIN-rail or field wiring while the module is powered?\u003c\/strong\u003e \u003cstrong\u003eA: No.\u003c\/strong\u003e This standalone device does not possess hot-swap mechanics. The external 24 VDC supply line and communication terminal rails must be isolated before service manipulation to prevent current transients or hardware breakdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the official recommended replacement product line since this module is discontinued?\u003c\/strong\u003e \u003cstrong\u003eA: The designated manufacturer replacement\u003c\/strong\u003e model for this legacy gateway platform is the ProSoft PLX31-EIP-MBS, which provides updated modern hardware profiles for EtherNet\/IP to Modbus protocol bridging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can Port 1 be configured as a Modbus Master running RS-485 while Port 2 operates as a Modbus Slave running RS-232?\u003c\/strong\u003e \u003cstrong\u003eA: Yes.\u003c\/strong\u003e Both serial interfaces function as electrically isolated networks. The serial transmission standard (RS-232, RS-422, or RS-485) and protocol state (Master or Slave) are handled independently via jumper placement and configuration parameters.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-rail Mounting Stability:\u003c\/strong\u003e Install the gateway onto a standard 35 mm DIN-rail. Ensure the internal ground clip makes firm, metal-to-metal contact with the rail, which must be grounded back to the main control panel ground bus bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Isolation and Cabling:\u003c\/strong\u003e Use shielded twisted-pair (STP) Category 5e cables for the Ethernet connection and high-quality shielded serial wire for the Modbus lines. Route all network lines through separate wire trays away from high-voltage motor or actuator lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-485 Line Bias and Termination:\u003c\/strong\u003e When deploying the serial interface in RS-485 mode across long communication distances, install a 120-ohm matching resistor across the terminal tips of the physical end nodes to diminish signal line reflections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":43475010715738,"sku":"5201-DFNT-MCM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/15._f04a8e82-954f-4f9d-a7f7-e6274f083892.jpg?v=1781056028"}],"url":"https:\/\/www.spareoil.com\/collections\/prosoft.oembed?page=2","provider":"SpareOil Automation","version":"1.0","type":"link"}