{"title":"Yokogawa network card","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eYokogawa VI701\u003c\/strong\u003e\u003cspan\u003e is a high-performance, 1Gbps Ethernet interface card designed for \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003eCS 3000\u003c\/strong\u003e\u003cspan\u003e DCS environments. It installs into industrial PCs to establish a reliable, dual-redundant connection to the \u003c\/span\u003e\u003cstrong\u003eVnet\/IP\u003c\/strong\u003e\u003cspan\u003e control bus. By supporting \u003c\/span\u003e\u003cstrong\u003e1000BASE-T\u003c\/strong\u003e\u003cspan\u003e standards and PCI\/PCI-X slots, it ensures high-speed, deterministic data exchange between operator stations and control units. This \u003c\/span\u003e\u003cstrong\u003ebrand-new\u003c\/strong\u003e\u003cspan\u003e original card features a rugged design for 24\/7 mission-critical stability, handling complex packet processing to offload the host CPU in demanding process industries.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"yokogawa-centum-cs-3000-vi701-vnet-ip-communication-card","title":"Yokogawa CENTUM CS 3000 VI701 Vnet\/IP Communication Card","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa VI701\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary hardware gateway between industrial workstations and the Vnet\/IP control bus. This high-performance interface card integrates Human Interface Stations (HIS) and Engineering Stations (ENG) into the CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e, ensuring maximum data throughput for your mission-critical process network.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe VI701 card establishes a high-speed, 1 Gbps redundant link over Yokogawa’s proprietary Vnet\/IP protocol. By installing this card into a standard PCI or PCI-X slot of an industrial PC, operators gain reliable access to real-time plant data and control parameters. The card handles the complex packet processing required for industrial Ethernet, offloading the communication burden from the PC’s main processor to maintain system responsiveness during high network traffic.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa VI701 configurations often follow specific suffix codes for functional variations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVI701-S1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard type for Vnet\/IP communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVI701-S1\/F9:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard type with additional compliance or documentation for specific regional standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVI701\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 Mbps (1 Gbps) Full Duplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000BASE-T Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePCI Bus Spec 3.0 (32-bit\/33 MHz) \/ PCI-X Compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual RJ45 (Supports Redundancy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAT5e UTP or higher\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 A at 3.3 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 meters to Layer 2 Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Path Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VI701 supports two physical ports, enabling a dual-redundant Vnet\/IP configuration. If one network path fails, the card switches communication to the secondary path instantaneously without interrupting process control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Bandwidth Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing 1 Gbps technology, this card prevents communication bottlenecks even in large-scale plant architectures with thousands of I\/O points and high-resolution HMI graphics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy Slot Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile optimized for PCI Bus 3.0, the card maintains physical and electrical compatibility with PCI-X slots at 33 MHz. This allows plants to utilize the card in a wide range of industrial server hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VI701 utilizes autonegotiation for 1000BASE-T, simplifying the handshake process with industrial Layer 2 switches and reducing the time required for network commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for 24\/7 continuous operation, the VI701 resists the electromagnetic interference (EMI) typical of industrial control rooms, ensuring data packets remain uncorrupted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the VI701 into a standard office PC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the VI701 uses a standard PCI interface, we strictly recommend installation in Yokogawa-certified industrial PCs. Industrial PCs provide the necessary cooling, power stability, and vibration resistance required for the VI701 to operate reliably within a DCS environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the VI701 require specific drivers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the VI701 operates under the CENTUM VP or CS 3000 software environment. The communication drivers are included with the Yokogawa HIS or ENG software packages to facilitate seamless Vnet\/IP bus recognition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the VI701 backward compatible with Vnet (non-IP) systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The VI701 is specifically designed for Vnet\/IP. If you are operating an older legacy Vnet (bus-based) system, you would typically require a different interface card like the VF701.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable distance between the VI701 and the switch?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1000BASE-T standard allows for a maximum distance of 100 meters using CAT5e or CAT6 UTP cabling. For distances exceeding 100 meters, you must utilize a fiber optic media converter or an intermediate switch.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194844086362,"sku":"VI701","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/416._11bb8278-256e-4de3-96e2-f7c0b4946f6a.jpg?v=1775715862"},{"product_id":"vi702-yokogawa-vnet-ip-interface-card-for-centum-vp-dcs","title":"VI702 Yokogawa Vnet\/IP Interface Card for CENTUM VP DCS","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa VI702\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-speed communication gateway for modern CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This PCI Express (PCIe) interface card connects Human Interface Stations (HIS) and Engineering Stations (ENG) directly to the Vnet\/IP control bus. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging to ensure mission-critical network reliability.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe VI702 replaces legacy PCI-based cards by utilizing the faster PCI Express x1 bus interface. It facilitates 1Gbps full-duplex communication, allowing operator stations to manage massive data flows from control units without latency. Designed for high-availability environments, the card supports redundant network architectures to prevent single points of failure in power plants, refineries, and chemical processing facilities. By offloading network stack processing to the specialized hardware on the VI702, the host PC maintains peak performance for HMI and engineering software applications.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa VI702 often includes suffix codes that designate specific hardware revisions or regional standards:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVI702-S1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard type for Vnet\/IP communication using the PCIe interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS9660DJ-01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal manufacturing or assembly reference code associated with the VI702 series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVI702\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePCI Express x1 slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 Mbps (1 Gbps) Full Duplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000BASE-T Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual RJ45 (Supports Redundant Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAT5e UTP or higher\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 VDC via PCI Express Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, RoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModern Hardware Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PCIe x1 interface ensures compatibility with the latest generation of industrial workstations and servers, bypassing the limitations of obsolete PCI slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital signal processing on the VI702 eliminates data packet loss during high-congestion periods. This ensures that critical alarms and process variables reach the operator station with sub-millisecond precision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Network Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual RJ45 ports allow for a physically redundant Vnet\/IP configuration. The card automatically manages path switching, ensuring continuous communication even if a cable or network switch fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact design improves airflow within the PC chassis, while the low current consumption (approx. 2.5 A) minimizes heat generation, extending the lifespan of both the card and the host workstation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Environment Preparedness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand industrial contamination, the VI702 maintains stable performance in environments where dust or humidity could compromise standard commercial network equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a legacy VI701 card with the VI702?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VI702 is the PCIe version of the VI701 (which uses standard PCI). While they perform the same communication role, the VI702 requires a PCI Express x1 slot. Verify your workstation’s motherboard slots before upgrading to ensure physical compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the VI702 support autonegotiation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The card fully supports autonegotiation for 1000BASE-T standards. It automatically synchronizes with industrial Layer 2 switches to establish the most stable 1Gbps full-duplex link available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs any special software required for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VI702 operates within the Yokogawa CENTUM VP or CS 3000 software environment. You must install the corresponding Vnet\/IP drivers provided with your Yokogawa DCS software package for the card to be recognized by the operating system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable distance supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card supports a maximum distance of 100 meters between the VI702 and the nearest Layer 2 switch using CAT5e or better cabling. For distances beyond 100 meters, we recommend using fiber optic media converters.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194856800346,"sku":"VI702","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/417._e3a69e60-3bff-457b-ad0f-8a697db67615.jpg?v=1775716238"},{"product_id":"vi451-10-style-s1-yokogawa-rs-485-rs-232-communication-module","title":"VI451-10 Style S1 Yokogawa RS-485 RS-232 Communication Module","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa VI451-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Communication Interface Module engineered for the CENTUM VP and CS 3000 Distributed Control Systems (DCS). This module establishes a robust bridge between field devices, standalone controllers, and supervisory networks. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring seamless data exchange across heterogeneous industrial environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe VI451-10 functions as a versatile multi-protocol gateway, allowing the Yokogawa DCS to communicate with external hardware using Modbus, Profinet, or EtherNet\/IP. It handles high-speed data acquisition with sampling rates up to 100 kHz, making it ideal for monitoring fast-acting process variables. By centralizing disparate signal types—including analog, digital, and pulse—into the unified Ovation\/CENTUM architecture, the VI451-10 simplifies system integration and enhances real-time process visibility.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe VI451 series utilizes specific suffixes to designate hardware and protocol capabilities:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVI451-10:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard high-speed communication module with support for Ethernet and serial protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStyle S1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the specific hardware revision and internal board architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVI451-10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Typical); \u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e 15 W Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e RJ-45 (100 Mbps Full Duplex)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e RS-485; 1 \u003cspan class=\"math-inline\"\u003e$\\times$\u003c\/span\u003e RS-232C (D-Sub 9-pin)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU\/TCP, Profinet, EtherNet\/IP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Hz to 100 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\/Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit resolution; \u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e 0.01% FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated 600 mA Self-resetting PTC Fuse\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReliability (MTTF)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 100,000 Hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Heterogeneous Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VI451-10 eliminates the need for third-party protocol converters by supporting Modbus, Profinet, and EtherNet\/IP natively. This reduces latency and simplifies the overall system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Capture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a sampling rate reaching 100 kHz, the module accurately tracks rapid pressure surges or high-speed pulse inputs that standard I\/O modules might miss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvercurrent Self-Healing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated 600 mA self-resetting PTC fuse protects the internal circuitry from field wiring faults. This feature allows the module to return to normal operation automatically once the fault is cleared, significantly reducing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Serial \u0026amp; Quad Ethernet Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe inclusion of four Ethernet ports and three serial interfaces (RS-485\/RS-232) in a single modular footprint maximizes cabinet space while providing extensive connectivity for smart instruments and PLCs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMission-Critical Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA Mean Time To Failure (MTTF) exceeding 100,000 hours ensures the VI451-10 meets the rigorous demands of continuous-process industries such as oil \u0026amp; gas and power generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the VI451-10 handle both Modbus RTU and Modbus TCP simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The hardware features dedicated RS-485 ports for RTU serial communication and RJ-45 Ethernet ports for TCP communication, allowing the module to act as a central hub for various Modbus-based devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a field device causes an overcurrent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module’s built-in PTC fuse will trip to protect the electronic components. Unlike traditional fuses, this PTC fuse resets itself once the electrical fault is removed and the module cools down, eliminating the need for manual fuse replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support high-resolution analog inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VI451-10 provides up to 16-bit resolution with an accuracy of\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e0.01% Full Scale. This precision makes it suitable for sensitive process variables that require high-fidelity measurement for accurate control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the VI451-10 compatible with the latest CENTUM VP software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The VI451-10 is fully compatible with CENTUM VP and legacy CS 3000 systems. Ensure you have the correct communication drivers and I\/O definitions configured within your engineering station.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194875641946,"sku":"VI451-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/418._1fddaa90-c2b1-4b38-9b09-757372459873.jpg?v=1775716640"},{"product_id":"sb301-yokogawa-dcs-interface-card-brand-new-original","title":"SB301 Yokogawa DCS Interface Card Brand New Original","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SB301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical S1 Interface Card designed for the CENTUM CS 3000 Distributed Control System (DCS). This module establishes the primary communication pathway between the core control architecture and external subsystems, ensuring seamless data synchronization. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, direct from Japan-origin stock, to guarantee system integrity in mission-critical environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe SB301 module functions as a robust bridge within the Yokogawa DCS ecosystem. It manages high-volume data traffic between the control stations and peripheral devices, maintaining the deterministic communication required for complex process automation. By utilizing the Style S1 architecture, this card provides the stable connectivity necessary to integrate sensors, actuators, and operator interfaces into a unified control strategy. It plays a fundamental role in maintaining the high availability and fault tolerance standards of the CENTUM CS 3000 series.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe SB301 series often includes specific manufacturing codes and style designations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSB301:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase model number for the Interface Card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStyle S1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the hardware revision and circuit board configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS9911DD-04:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal Yokogawa manufacturing reference for the specific card assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSB301 (Style S1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM CS 3000 DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS9911DD-04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication \/ System Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 cm x 26.2 cm x 24.9 cm (1.0 x 10.3 x 9.8 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg (0.75 lbs - 2.0 lbs depending on housing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTariff Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8517620050\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Bus Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SB301 utilizes specialized chipsets to manage bus arbitration. This prevents data collisions and ensures that time-sensitive control commands reach their destination without jitter or delay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for continuous-process industries, the card supports installation into active CS 3000 racks. This allows maintenance teams to replace interface components without forcing a total system shutdown, significantly reducing plant downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Slot Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2.5 cm slim profile allows for high-density mounting in control cabinets. This maximizes the available space within standard Yokogawa racks, facilitating future system expansion without requiring additional cabinetry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade EMI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe card features robust electromagnetic interference (EMI) shielding. This protection ensures that high-voltage equipment in the vicinity—such as turbines or large motors—does not corrupt the low-voltage communication signals passing through the SB301.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJapanese Precision Engineering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufactured in Japan, the SB301 meets the highest global standards for reliability (MTBF). It withstands the thermal stresses of 24\/7 operation in harsh petrochemical and power generation environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SB301 compatible with the newer CENTUM VP systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SB301 is primarily engineered for the CENTUM CS 3000 series. While Yokogawa offers migration paths, you should consult your specific system topology to determine if an SB301 or a newer VP-series card is required for your hardware revision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Style S1\" designation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Style\" code indicates a specific hardware version. Style S1 ensures that the card features the standardized circuitry and component layout required for compatibility with original CS 3000 backplanes. We recommend matching the style code of your existing card for seamless replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this card require manual configuration or calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SB301 is a digital interface card. Most configurations occur within the CENTUM engineering software. Once installed into the correct slot on the base unit, the system software recognizes the card and assigns the necessary communication parameters based on your project database.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the SB301 handle communication faults?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes built-in diagnostic LEDs that provide immediate status feedback. If a communication error occurs, the card reports the fault back to the HIS (Human Interface Station), allowing operators to pinpoint the exact location of the connectivity issue.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194884128858,"sku":"SB301","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/195._e579b961-2678-4f1e-97d1-e9f901dbb1c3.jpg?v=1775716858"},{"product_id":"vf701-yokogawa-dual-redundant-control-bus-card-original","title":"VF701 Yokogawa Dual Redundant Control Bus Card Original","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa VF701\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Style S3) is a high-performance Vnet\/IP Control Bus Interface Card designed for the CENTUM VP and ProSafe-RS Distributed Control Systems (DCS). This card installs directly into industrial PCs to facilitate a high-speed link between operator stations and the control network. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packing to ensure maximum uptime in critical process environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe VF701 acts as the primary hardware gateway for Vnet\/IP communication. It manages high-volume data traffic between Human Interface Stations (HIS), Engineering Stations (ENG), and field control units. By supporting 1 Gbps transmission speeds, the VF701 ensures real-time data synchronization and rapid alarm response. This card plays a decisive role in large-scale industrial plants where synchronized control and safety communication are non-negotiable.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe VF701 series includes specific hardware revisions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVF701:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the Vnet\/IP Interface Card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStyle S3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the third-generation hardware revision, optimized for modern PCI bus stability and enhanced EMI resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVF701 (Style S3)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP \/ ProSafe-RS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 Mbps (1 Gbps) \/ 100 Mbps Full Duplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000BASE-T \/ 100BASE-TX Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ-45 (Ethernet) \/ BNC (Legacy 10BASE-2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard PCI Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Dual-Redundant Vnet\/IP Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +55°C (32°F to 131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (Shipping Weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGigabit Deterministic Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VF701 utilizes 1000BASE-T technology to deliver low-latency communication. This ensures that safety-critical signals and high-frequency process variables reach the operator console without the jitter associated with standard commercial network cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Redundant Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe card facilitates Yokogawa’s signature redundant Vnet\/IP networking. If a primary network path fails, the card manages an instantaneous switchover to the secondary path, preventing any loss of control or visibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy and Modern Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe inclusion of both RJ-45 and BNC connectors allows the VF701 to bridge modern Ethernet-based networks with legacy 10BASE-2 coaxial segments. This makes it an ideal choice for phased system upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa engineers the VF701 with high-level electromagnetic interference (EMI) resistance. It maintains stable data packets even in electrical rooms housing high-capacity variable frequency drives (VFDs) and heavy switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePassive Host Offloading:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard processor handles network protocol management, significantly reducing the CPU load on the host PC. This allows the HIS or ENG station to maintain peak performance during complex engineering tasks or major plant upsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the VF701 support ProSafe-RS safety systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The VF701 is fully compatible with both CENTUM VP control systems and ProSafe-RS safety instrumented systems (SIS), allowing for a unified communication platform across the entire plant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the VF701 in any standard PC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VF701 requires a standard PCI slot. While it fits many industrial PCs, we recommend verifying that your station’s motherboard and operating system support Yokogawa's Vnet\/IP drivers for this specific card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum distance for Vnet\/IP cabling with this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen using the RJ-45 (Ethernet) port, the maximum distance to the nearest switch is 100 meters. For legacy BNC coaxial connections, the card supports distances up to 185 meters per segment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the card receive power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VF701 draws all necessary power directly from the host PC's PCI bus. It requires no external power supply, which simplifies installation and reduces the potential points of failure within the cabinet.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194936361050,"sku":"VF701","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/202._91a24ed3-b81f-4ffa-8a01-888a0b2a0133.jpg?v=1775720831"},{"product_id":"100mbps-fast-ethernet-bus-module-eb501-10-s2-yokogawa","title":"100Mbps Fast Ethernet Bus Module | EB501-10 S2 Yokogawa","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa EB501-10 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance System Bus Communication Interface Module designed for the CENTUM VP and CS 3000 Distributed Control Systems (DCS). This module establishes the primary communication link across the S2 system bus and the Vnet\/IP network. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packing to ensure maximum network stability for your industrial automation architecture.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe EB501-10 S2 acts as the critical hardware bridge between controllers, Human Interface Stations (HIS), and engineering tools. It facilitates deterministic, high-speed data exchange, ensuring that process variables and control commands synchronize across the entire DCS network. By supporting the S2 bus architecture, this module offloads complex communication tasks from the main processor, maintaining sub-millisecond response times even in high-traffic process environments. Its compact, PCI-based design allows for seamless integration into station backplanes, making it essential for stable system-wide data transparency.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa EB501 configurations follow a specific technical nomenclature:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEB501:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the System Bus Interface Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-10:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the specific version and communication speed profile (100 Mbps).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the hardware style and revision for S2 bus compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEB501-10 S2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP \/ CS 3000 (S2 Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication interface for System Bus\/Vnet-IP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbps Fast Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePCI-based card for station integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ-45 Ethernet Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 V via backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 cm x 2.5 cm x 12.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic S1\/S2 Bus Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe EB501-10 S2 provides a dedicated path for 100 Mbps communication, eliminating data packet collisions and ensuring that time-critical process data reaches the controller with absolute predictability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Backplane Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PCI-based architecture allows the module to draw its operational 3.3 VDC power directly from the backplane. This removes the need for external power wiring and reduces potential failure points within the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa builds this module with high-level electromagnetic interference (EMI) resistance. It maintains uncorrupted signal transmission even when located in electrical rooms housing high-capacity variable frequency drives (VFDs) or heavy switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact, High-Density Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring only 2.5 cm in width, this modular card maximizes available slot density within the control station. This allows for complex network configurations in space-constrained industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe RJ-45 port supports CAT5e or higher cabling, ensuring a secure mechanical lock and high-speed data integrity over distances up to 100 meters without signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the S1 and S2 versions of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S2\" suffix indicates the hardware style specifically optimized for the S2 bus architecture used in certain CENTUM VP station configurations. While both support Fast Ethernet, the S2 revision ensures timing synchronization with modern S2-bus compatible backplanes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the EB501-10 S2 require separate software drivers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module integrates natively with the Yokogawa CENTUM VP engineering station software. Once you seat the card in the PCI slot and perform a system scan, the DCS recognizes the hardware and configures the communication parameters automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard Ethernet cables for the S2 bus link?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module utilizes a standard RJ-45 connector and supports CAT5e or higher cabling. For industrial environments with high electrical noise, we recommend using shielded (STP) cables to protect the 100 Mbps data packets from EMI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the communication status?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EB501-10 S2 features onboard LED indicators that provide real-time status of link activity, data transmission, and hardware health. These indicators help engineers quickly troubleshoot network issues without opening the DCS diagnostic software.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194941472858,"sku":"EB501-10 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/203._594aec52-8e2d-4adf-85a6-f52495069058.jpg?v=1775721228"},{"product_id":"vf702-yokogawa-vnet-ip-pcie-interface-card-for-centum-vp","title":"VF702 Yokogawa Vnet\/IP PCIe Interface Card for CENTUM VP","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa VF702\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Style S1) is a high-performance, dual-port PCI-Express (PCIe) x1 Control Bus Interface Card engineered for the CENTUM VP Distributed Control System (DCS) and ProSafe-RS Safety Instrumented System (SIS). This card establishes the critical Vnet\/IP link between Human Interface Stations (HIS) or Engineering Stations (ENG) and the control network. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packing, ensuring mission-critical stability for your plant's communication backbone.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe VF702 facilitates high-speed, redundant 1 Gbps data transmission, serving as the hardware gateway for the Vnet\/IP control bus. By utilizing the modern PCIe x1 architecture, it offers significantly faster data throughput and lower latency compared to legacy PCI interface cards. This module manages real-time process data, alarms, and control commands, ensuring seamless synchronization between operator stations and field control units in large-scale industrial environments.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa VF702 series hardware adheres to strict revision and style standards:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVF702:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the Vnet\/IP PCIe Interface Card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStyle S1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the first-generation PCIe hardware revision, optimized for dual-port redundancy and modern workstation compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVF702 (Style S1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM VP, ProSafe-RS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePCI-Express (PCIe) x1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 Mbps (1 Gbps) \/ 100 Mbps Full Duplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000BASE-T \/ 100BASE-TX Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual RJ-45 Ethernet Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Dual-Redundant Vnet\/IP Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Cable Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 m (Standard Ethernet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +55°C (32°F to 131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (Shipping weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized PCIe Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe VF702 leverages the PCI-Express x1 bus to provide superior data bandwidth over older PCI cards. This architecture minimizes communication bottlenecks during major plant upsets when alarm traffic and data polling peak.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Redundancy Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-port design allows for direct connection to redundant Vnet\/IP networks. The card automatically manages path switching without host CPU intervention, guaranteeing continuous visibility of the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Latency Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized onboard processing ensures that control signals and safety interlocks transmit with minimal delay. This determinism is vital for synchronizing complex control loops across multiple stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade EMI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for the electrical noise of industrial control rooms, the VF702 features robust electromagnetic interference (EMI) resistance. It maintains signal integrity even when installed in workstations near high-power switchgear or VFDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Safety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause the VF702 is compatible with both CENTUM VP and ProSafe-RS, it enables a unified communication environment. This simplifies spare parts management and training for maintenance teams overseeing both control and safety systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main difference between the VF701 and the VF702?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe primary difference lies in the bus interface. The VF701 uses a standard PCI slot, while the VF702 utilizes the faster and more modern PCI-Express (PCIe) x1 interface, making it compatible with current-generation industrial workstations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this card require an external power source?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The VF702 draws all necessary operational power directly from the PCIe x1 slot on the station's motherboard. This simplifies internal cabinet wiring and reduces potential failure points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the redundancy on the VF702?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRedundancy is handled through the Yokogawa Vnet\/IP driver settings within the CENTUM VP or ProSafe-RS engineering environment. Once you connect cables to both RJ-45 ports, the software manages the primary and secondary communication paths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the VF702 operate at 100 Mbps if my switch does not support Gigabit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The card supports auto-negotiation and can operate at 100 Mbps (100BASE-TX) full duplex, though 1000 Mbps (1Gbps) is recommended to take full advantage of the Vnet\/IP bus performance.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194965622874,"sku":"VF702","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/208_3aef3e01-f49e-4243-a741-e98ae8609c6d.jpg?v=1775723218"},{"product_id":"alp111-s00-12mbps-communication-card-yokogawa-centum-vp","title":"ALP111-S00 12Mbps Communication Card | Yokogawa CENTUM VP","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ALP111-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance PROFIBUS-DP Communication Module designed for the CENTUM VP and CS 3000 Distributed Control Systems (DCS). This module provides essential PROFIBUS-DP master functionality, allowing the Field Control Station (FCS) to manage and exchange data with a wide array of field devices. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory packaging, ensuring seamless integration and industrial-grade reliability for your FIO (Field I\/O) units.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ALP111-S00 operates as a dedicated communication gateway between Yokogawa's control stations and PROFIBUS-DP slave devices such as remote I\/O, PLCs, and smart transmitters. By supporting the DP-V0 standard, this module facilitates deterministic data acquisition and control commands across the fieldbus. It offloads complex protocol management from the main processor, ensuring that your DCS maintains peak performance even when managing high-density fieldbus networks. This module is indispensable for plants utilizing multi-vendor field devices within a unified Yokogawa control environment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eALP111-S00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS-DP (DP-V0 Compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 kbps to 12 Mbps (Auto-negotiation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 km per segment (at 9.6 kbps)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEIA-RS-485 Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully Isolated Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAFV30\/40, ANB10\/11, ANR10 Node Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 cm (W) x 12.4 cm (H) x 12.6 cm (D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg (Net) \/ 1.5 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Determinism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ALP111-S00 supports transmission speeds up to 12 Mbps. This allows for rapid I\/O updates and minimizes loop latency, making it ideal for high-speed manufacturing and safety-critical process controls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe EIA-RS-485 interface features full signal isolation. This hardware barrier prevents ground loops and protects the DCS backplane from electrical surges and EMI noise generated by field-side equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Deployment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module fits into a wide variety of Yokogawa node units, including the ANB10 (ESB bus) and ANR10 (ER bus). This flexibility enables engineers to place PROFIBUS-DP master functionality exactly where the field density requires it.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Distance Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting lower baud rates, the module facilitates communication segments up to 1.2 km. This eliminates the need for expensive repeaters in large-scale plant layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFIO System Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 2.2 cm width allows for maximum card density within the FIO rack. This reduces the total number of node units required, lowering the overall cost of the control system infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ALP111-S00 support the DP-V1 or DP-V2 standard?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ALP111-S00 is primarily compliant with the PROFIBUS-DP V0 standard. It focuses on high-speed cyclic data exchange (Input\/Output data). For applications requiring acyclic communication (DP-V1), please verify your specific DCS software revision and GSD file requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this module in an active Field Control Unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, Yokogawa FIO modules generally support hot-swapping within redundant configurations. However, we recommend following the procedure outlined in the CENTUM VP hardware manual to ensure the bus remains stable during the insertion of a new ALP111-S00 module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of slave devices per module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ALP111-S00 can theoretically address the standard PROFIBUS limit of 126 devices; however, the actual number of connected slaves depends on the bus speed, the amount of data per slave, and the DCS station's total I\/O capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a specific cable required for the 12 Mbps speed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To achieve speeds up to 12 Mbps, you must use PROFIBUS-certified Type A shielded twisted-pair cable. Standard RS-485 cable may not provide sufficient signal integrity for the higher frequency data rates supported by the ALP111-S00.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43194967720026,"sku":"ALP111-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/209._7da40061-2696-46bd-98b8-55925efa6ff8.jpg?v=1775723403"},{"product_id":"acm22rs-422-485-yokogawa-serial-communication-module-new","title":"ACM22RS-422\/485 Yokogawa Serial Communication Module New","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ACM22RS-422\/485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Serial Communication Module designed for the CENTUM VP and CS 3000 Distributed Control Systems (DCS). This module provides two independent ports for RS-422 or RS-485 connectivity, allowing the DCS to interface directly with external PLCs, analyzers, and intelligent field instruments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring stable and high-speed data exchange for your critical process automation network.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ACM22RS-422\/485 acts as a robust gateway for serial data, supporting industry-standard protocols such as Modbus RTU. By offloading serial polling tasks from the main Field Control Station (FCS), this module maintains system responsiveness even when managing dense networks of slave devices. It effectively bridges the gap between supervisory control and specialized third-party hardware, making it a vital component for oil and gas, chemical processing, and power generation facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACM22RS-422\/485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-422 \/ RS-485 (Selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Independent Serial Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 bps to 115.2 kbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Distance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 1200 m (RS-485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptical Isolation (Field-to-System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU, Proprietary Serial Protocols\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC via Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Block for Field Wiring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Isolation Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ACM22RS incorporates advanced optical isolation between the field-side circuits and the internal system bus. This hardware barrier prevents ground loops and protects the DCS from high-voltage transients often encountered in long-distance serial wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Port Integration Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach module provides two independent ports. This allows engineers to manage two separate serial networks (e.g., one Modbus RTU loop and one proprietary loop) using a single card, significantly reducing the required rack space and system costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Transmission Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports reliable communication over distances up to 1200 meters using the RS-485 standard. This eliminates the need for signal repeaters in large-scale plant layouts where external instruments reside far from the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith selectable baud rates up to 115.2 kbps, the ACM22RS handles rapid data polling for real-time monitoring. This ensures that the DCS captures process changes from intelligent devices with minimal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Industrial Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for 24\/7 operation in harsh environments, the card performs reliably in temperatures up to 60°C. The robust terminal block connectors ensure gas-tight, vibration-resistant field connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use Port 1 for RS-422 and Port 2 for RS-485 simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The two ports on the ACM22RS operate independently. You can configure each port with its own communication standard, baud rate, and parity settings to match the specific requirements of your field equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support Modbus ASCII?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ACM22RS primarily targets Modbus RTU for high-efficiency industrial data exchange. However, compatibility with other serial protocols depends on the configuration of the Yokogawa DCS communication package. Most proprietary serial strings are manageable via the station builder.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the optical isolation feature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn industrial plants, long serial cables often pass near high-power motors or switchgear, which can induce significant electrical noise. Optical isolation ensures this noise does not reach the CPU or backplane, preventing system crashes and data corruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the terminating resistors for RS-485?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTerminating resistors are essential for long-distance RS-485 loops to prevent signal reflection. You typically set these resistors via hardware switches on the module or through external wiring at the terminal block, depending on the specific hardware revision.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43195054260314,"sku":"ACM22RS-422\/485","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/214._92fdc57a-3a33-48a2-8a42-b3760a854bfa.jpg?v=1775727595"},{"product_id":"yokogawa-fca4-a-interface-module-card","title":"Yokogawa FCA4*A Interface Module Card","description":"\u003ch2\u003eYokogawa FCA4*A Interface Module Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa FCA4*A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFCA4*A\u003c\/strong\u003e Interface Module Card, operates as a dedicated hardware component for signal communication and I\/O integration within Yokogawa control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFCA4*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan \/ Singapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 20 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capability\u003c\/td\u003e\n\u003ctd\u003eAnalog and digital signal processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe FCA4*A facilitates high-speed data exchange between field instrumentation and control processors. To maintain loop integrity in distributed control systems, the module supports multi-channel I\/O configurations, which require precise impedance matching for 4-20 mA HART loop protocol adherence. In applications where long cable runs are present, ensure that channel-to-channel isolation parameters are observed to prevent ground loops that could introduce common-mode noise into the process signal. When integrating with Foundation Fieldbus or Profibus PA segments, verify that the module firmware revision is compatible with the existing host control station bus communication velocity to avoid deterministic network latencies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swapping within the control rack?\u003c\/p\u003e\n\u003cp\u003eA: The FCA4*A allows for removal and replacement; however, ensure the specific I\/O channel is set to a safe state or manual control mode within the DCS software to prevent process disturbances during the transition.\u003c\/p\u003e\n\u003cp\u003eQ: Is external signal conditioning required for low-level thermocouple inputs?\u003c\/p\u003e\n\u003cp\u003eA: While the FCA4*A supports various analog signals, ensure the internal module configuration matches the specific sensor type. If cold junction compensation (CJC) is not handled internally by the specific sub-model configuration, external hardware or baseplate compensation may be required to maintain measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the FCA4*A securely into the designated rack slot, ensuring the backplane pins are aligned to prevent mechanical damage. If using the optional panel or DIN rail mount, ensure the module housing is flush to prevent vibration-induced stress on the connector terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field wiring using the appropriate shielded twisted-pair cables. Ground the shield at the cabinet entry point using an approved grounding bar to maintain electromagnetic compatibility (EMC) and prevent interference from high-frequency power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e After physical installation, perform a status check via the DCS maintenance interface to confirm module recognition and power-on self-test (POST) completion. Validate loop continuity for each channel before initiating active control output.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43582292590682,"sku":"FCA4*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/431._c675449b-721f-4205-97e8-c0da930d53a3.jpg?v=1782979856"},{"product_id":"yokogawa-dp97-b-distributed-control-system-processor-card","title":"Yokogawa DP97-B Distributed Control System Processor Card","description":"\u003ch2\u003eYokogawa DP97-B Display Processor Card\u003c\/h2\u003e\n\u003cp\u003eConfigured for graphical rendering and operator interface management in Yokogawa distributed control systems, the \u003cstrong\u003eYokogawa DP97-B\u003c\/strong\u003e (\u003cstrong\u003eDP97-B\u003c\/strong\u003e Display Processor Card) provides direct physical execution of HMI video signal processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 195.938px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 39.4907%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 55.9895%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003eDP97-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003e2.5 × 38.1 × 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003e12 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003eInterface\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003e4 Coaxial (KB, R, G, B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.4907%; height: 19.5938px;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"width: 55.9895%; height: 19.5938px;\"\u003eRack-mount \/ Backplane slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Signal Isolation and Graphical Integrity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDP97-B\u003c\/strong\u003e utilizes dedicated video signal processing to maintain graphical determinism across operator stations. To preserve image fidelity, the card incorporates channel-to-channel isolation within the internal video circuitry. This design mitigates electromagnetic interference (EMI) that often manifests as visual noise or jitter in high-speed rendering paths. By isolating the video signal ground from the primary system bus, the module prevents potential ground loops generated by peripheral display hardware, ensuring stable HMI refreshes during critical control operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DP97-B support hot-swapping for rapid maintenance?\u003c\/p\u003e\n\u003cp\u003eA: No, the DP97-B does not support hot-swapping. The system must be powered down and the backplane de-energized before extracting or inserting the module to prevent electrical damage to the bus interface.\u003c\/p\u003e\n\u003cp\u003eQ: What are the requirements for video signal cabling?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes four coaxial connectors for KB, R, G, and B signals. Shielded coaxial cabling is required to maintain signal integrity and meet the electromagnetic compatibility (EMC) standards of the installation environment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the rack-mount slot is clean and free of debris. Align the module carefully with the backplane guides and press firmly until the connector fully seats. Secure the front panel screws to ensure robust grounding to the cabinet chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the module to the cabinet protective earth (PE) bus. Ensure that the impedance of the ground connection is within industrial limits to maintain the isolation efficacy of the video output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Use shielded cabling for all video outputs. Route cables away from high-current power lines or VFD cabling to minimize inductive coupling and potential distortion of the graphical output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Operate within the specified temperature range of 0 to 50 deg C. Monitor airflow around the card cage to prevent heat accumulation, as the module requires passive convection for its 12 W thermal profile.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43627032969306,"sku":"DP97-B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/497._9b5538d5-e7cb-4000-b174-498cc9b07ce3.jpg?v=1783651416"},{"product_id":"32-channel-digital-i-o-card-yokogawa-mx3-d-cs-3000","title":"32-Channel Digital I\/O Card | Yokogawa MX3*D CS 3000","description":"\u003ch2\u003eYokogawa MX3*D Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa MX3*D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMX3\u003c\/strong\u003e Digital I\/O Card, operates as a dedicated hardware component for discrete input and output signal processing within CENTUM VP and CS 3000 networks. The hardware interfaces directly with field switches, interlock relays, and solenoid loops, converting high-density external state variations into structured status arrays for transmission across the system backplane bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMX3*D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (module weight) \/ 0.6 kg (with packaging configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 25 mm x 130 mm (card size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.0 W (calculated from 5 VDC, 1.2 A backplane draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 digital I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete ON\/OFF (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (channel-to-system, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Process Interface\u003c\/h3\u003e\n\u003cp\u003eThe discrete card processes 32 high-density digital I\/O channels configured for nominal 24 VDC industrial loops. To intercept common-mode transient voltage spikes from reaching the core system processors, the module maintains an onboard galvanic isolation barrier rated at 1500 VAC between the field terminal side and the system logic interface. Individual field outputs support a continuous driving capacity up to 0.5 A per channel, deploying automatic overcurrent dampening thresholds to protect the internal silicon switches from inductive voltage kickback during valve or relay de-energization. Front-panel diagnostic indicators map specific states directly, utilizing physical LEDs to indicate discrete channel ON\/OFF conditions and active circuit faults.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the MX3*D respond to an overcurrent condition on a single digital output channel?\u003c\/p\u003e\n\u003cp\u003eA: The card incorporates autonomous electronic current limiting for each individual output path. When a connected solenoid or external load exceeds the 0.5 A allocation, the localized channel circuit clamps the current to prevent internal thermal degradation, illuminating the front-panel fault indicator without affecting the logic execution of adjacent channels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support online extraction and replacement during active dual-redundant execution?\u003c\/p\u003e\n\u003cp\u003eA: Yes, when deployed in a paired dual-redundant configuration within the slot framework, the backup architecture permits full hot-swap operations. Removing an active module shifts the discrete I\/O polling sequence to the parallel card within less than one system scan cycle, preventing signal drops to critical field safety loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubrack Engagement Sequence:\u003c\/strong\u003e Slide the I\/O card along the designated vertical guide slots within the field control unit (FCU) chassis assembly. Verify that the alignment tabs seat perfectly into the rear backplane receptacle before pivoting the extraction levers to secure the module pins into the active multi-pin connector block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Signal Shielding:\u003c\/strong\u003e Route all 24 VDC discrete signal paths through dedicated field wiring ducts separate from primary AC distribution lines. Terminate all multi-pair cable shields at the single instrument ground plane bar located inside the marshalling cabinet enclosure to inhibit external inductive noise propagation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Thermal Maintenance:\u003c\/strong\u003e Maintain uniform convective air patterns beneath the chassis card space. Ensure that total cumulative module current demands do not force the localized ambient microclimate above the 60 deg C operational limits, preventing rapid thermal stress on the electronic solid-state switches.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43668069285978,"sku":"MX3*D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/584..jpg?v=1784257878"},{"product_id":"mx6-a-yokogawa-centum-vp-analog-i-o-module-s9840bp-05","title":"MX6*A Yokogawa CENTUM VP Analog I\/O Module S9840BP-05","description":"\u003ch2\u003eYOKOGAWA MX6*A INTERFACE MODULE CARD\u003c\/h2\u003e\n\u003cp\u003eConfigured for Specific Technical Task in System\/Network Name, the \u003cstrong\u003eYOKOGAWA MX6*A\u003c\/strong\u003e (\u003cstrong\u003eMX6-A\u003c\/strong\u003e Analog I\/O Module) provides direct physical\/electrical execution. This hardware component interfaces directly with field transmitters, sensors, and actuators to process high-density analog signals while maintaining structural isolation from the core backplane logic. The module supports point-to-point operational monitoring via integrated diagnostic light-emitting diodes (LEDs) to verify localized loop continuity and operational state transitions without external diagnostic tooling.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMX6*A (MX6-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 25 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number Variant\u003c\/td\u003e\n\u003ctd\u003eS9840BP-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 analog I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 1 to 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1 to 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (channel-to-system, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators for channel ON\/OFF and fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant operation supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mounted (FCU slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Analog Loop Execution\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA MX6*A\u003c\/strong\u003e utilizes a dedicated 4-20 mA HART loop protocol architecture to govern field communication loops, ensuring deterministic updates across all 32 channels. Channel-to-channel isolation parameters prevent ground loop transients from propagating through the internal field control units (FCU). For thermal and voltage stabilization, the onboard firmware applies cold junction compensation (CJC) algorithms alongside zero-point offset tracking to suppress signal drift across the entire 0 to 60 deg C operational band. The module dynamically manages output impedances to ensure linear actuator positioning and precise sensor conversions down to the +\/-0.1% accuracy threshold.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module execute dual-redundancy switching during a backplane communication fault?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on parallel rail topology inside the FCU slot. When the primary card drops internal heartbeats, the backup module assumes control of the 4-20 mA loop within predefined milliseconds without interrupting output signals to field actuators.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the field control unit is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, hot-swapping is supported. However, the online replacement sequence requires the user to verify the redundant mate is active and error-free before extracting the faulty module to prevent loop interruption.\u003c\/p\u003e\n\u003cp\u003eQ: What specific fault states trigger the diagnostic LEDs?\u003c\/p\u003e\n\u003cp\u003eA: The hardware diagnostic LEDs change status when detecting open-loop field wiring conditions, short circuits on individual 4-20 mA loops, or an internal hardware failure within the analog-to-digital converter circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Alignment:\u003c\/strong\u003e Insert the module vertically into the designated rack-mounted FCU slot. Ensure the top and bottom locking tabs click into place to maintain reliable electrical connectivity with the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate all analog signal cable shields at the dedicated marshalling cabinet ground bar. Do not allow multi-point grounding loops to form between the field transmitter chassis and the module rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route low-voltage 4-20 mA and 1-5 VDC signal lines via separate wire ducts, maintaining a distance of at least 300 mm from high-voltage AC power lines to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain unimpeded vertical airflow through the chassis assembly. Verify that total cabinet power consumption does not exceed the ambient heat dissipation rating to keep temperatures below 60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43668088586330,"sku":"MX6*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/585.jpg?v=1784258040"},{"product_id":"yokogawa-nc2-c-centum-vp-network-module-nc2-c","title":"Yokogawa NC2 C CENTUM VP Network Module NC2*C","description":"\u003ch2\u003eYOKOGAWA NC2*C Vnet\/IP Network Communication Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for Specific Technical Task in System\/Network Name, the \u003cstrong\u003eYOKOGAWA NC2*C\u003c\/strong\u003e (\u003cstrong\u003eNC2 C\u003c\/strong\u003e Network Communication Module) provides direct physical\/electrical execution. This hardware component functions as the deterministic interface layer managing raw data packet transmissions between field control units (FCUs) and the primary Vnet\/IP system bus. The module establishes physical media connections over Ethernet-based infrastructure to synchronize control topologies, utilizing localized light-emitting diodes (LEDs) to register hardware status transitions, link activity, and bus fault codes directly at the rack assembly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNC2*C (NC2 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 25 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP (Ethernet-based)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant communication supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (system-to-bus, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators for link, activity, and fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mounted (FCU slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Network Topology Execution\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA NC2*C\u003c\/strong\u003e coordinates industrial control network frames across the Vnet\/IP bus architecture via dedicated channel-to-channel isolation circuits designed to arrest electrical transients before they reach the control backplane. To protect internal communication loops, the module maintains a strict 1500 VAC system-to-bus galvanic isolation standard. The internal processor handles high-speed 100 Mbps data throughput using precise clock synchronization mechanics, mitigating transmission latencies and ensuring deterministic network scheduling. Dual-bus media control rules prevent data collisions and ground potential differentials from corrupting real-time process control data streams under steady-state operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the network module execute the switchover sequence during a Vnet\/IP cable break?\u003c\/p\u003e\n\u003cp\u003eA: The module operates on a dual-redundant Vnet\/IP bus topology. If the active channel detects a link failure or packet corruption, the internal communication processor switches all transmission lines to the secondary bus path within deterministic limits to maintain real-time process monitoring.\u003c\/p\u003e\n\u003cp\u003eQ: Are there any hardware restrictions when hot-swapping this module in an active FCU rack?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is permitted provided that the parallel redundant module is fully initialized, online, and carrying active network traffic. You must verify that the fault LED on the companion module is completely dark before removing the target card.\u003c\/p\u003e\n\u003cp\u003eQ: What structural grounding measures protect the 100 Mbps Vnet\/IP physical layer?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on integrated shielding contacts within the FCU slot and standard RJ45\/STP connectors. These components shunt high-frequency electrostatic noise away from the internal logic circuits directly into the common rack ground plane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Insertion:\u003c\/strong\u003e Align the module guide rails with the designated vertical FCU slot. Push the assembly inward until the structural locking connectors click completely into the backplane, confirming full pin engagement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cabling:\u003c\/strong\u003e Use high-quality Shielded Twisted Pair (STP) cables to connect to the Vnet\/IP network switches. Avoid laying communication media parallel to high-voltage AC cables to minimize cross-talk interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocol:\u003c\/strong\u003e Ensure the main equipment rack connects to a low-impedance instrument ground system. Verify that the shield drain wires of the network trunks terminate at a single point to prevent internal ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Limits:\u003c\/strong\u003e Verify that cabinet cooling fans maintain steady airflow over the slot array. Ambient operating temperatures must not exceed 60 deg C, and relative humidity must remain non-condensing between 5 and 95%.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43668092321882,"sku":"NC2*C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/586..jpg?v=1784258334"},{"product_id":"st3-a-yokogawa-centum-vp-interface-module","title":"ST3*A Yokogawa CENTUM VP Interface Module","description":"\u003ch2\u003eYOKOGAWA ST3*A System Bus Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA ST3*A\u003c\/strong\u003e serves as the primary \u003cstrong\u003eST3 A\u003c\/strong\u003e System Bus Interface Module utilized to execute deterministic data transfer across CENTUM VP platforms. This hardware component mounts directly into the field control unit (FCU) rack slot to establish a physical and electrical communication link between the internal logic processors and the external ESB\/ER extension buses. The unit processes field signal configurations via embedded diagnostic circuitry, utilizing localized light-emitting diodes (LEDs) to monitor link status, bus activity, and hardware faults in real time.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eST3*A (ST3 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 25 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, ~1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eESB\/ER bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant communication supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbps (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (system-to-bus, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Density\u003c\/td\u003e\n\u003ctd\u003e32 points (16 x 2 configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection Type\u003c\/td\u003e\n\u003ctd\u003eM4 Screw Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators for link, activity, and fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mounted (FCU slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Analog Loop Execution\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA ST3*A\u003c\/strong\u003e incorporates channel-to-channel isolation architecture to prevent high-voltage transients from compromising the internal system bus logic during active data acquisition. Operating over the ESB\/ER bus protocol, the module provides a strict 1500 VAC galvanic isolation barrier between the processing logic and external physical lines. Internal circuitry mitigates common-mode noise issues, allowing the 32-point signal distribution matrix to maintain linear signal integrity without zero-drift distortion. The module dynamically manages data packet prioritization over the 100 Mbps communication medium, enabling continuous synchronization between remote expansion chassis and the master controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle a communication failure on the primary ESB\/ER bus line?\u003c\/p\u003e\n\u003cp\u003eA: The module executes a dual-redundant tracking routing strategy. If the primary extension bus link experiences a packet timeout or signal degradation, the onboard hardware logic initiates a hot-standby switchover to the secondary redundant bus line without causing an interruption in the control process.\u003c\/p\u003e\n\u003cp\u003eQ: Is it permissible to perform an online hot-swap of this module while the FCU is live?\u003c\/p\u003e\n\u003cp\u003eA: Yes, online replacement is supported provided that the parallel tracking module is fully functional and synchronized. The field technician must confirm that the active mate displays a solid green link status and no fault indications before extracting the module from the backplane connector.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary structural differences between the two weight specifications listed in product variants?\u003c\/p\u003e\n\u003cp\u003eA: The base rack-mounted card component weighs approximately 0.35 kg, whereas variations equipped with integrated M4 screw terminal block assemblies and structural field wiring enclosures weigh up to 1.5 kg.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the printed circuit board edges with the guide rails of the designated FCU slot. Smoothly slide the module inward until the rear pins seat completely into the backplane connector, then secure the top and bottom latch mechanisms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Connect all external signal cable shields to the main instrumentation ground bus of the cabinet. Do not configure multi-point shield connections, as this induces ground loop interference across the 32-channel system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Constraints:\u003c\/strong\u003e Route the high-speed ESB\/ER bus cables through dedicated low-voltage wiring trays. Maintain a minimum physical clearance of 300 mm from any high-current AC power conductors or variable frequency drive cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Conditioning:\u003c\/strong\u003e Verify that the open spaces above and below the FCU rack remain free of obstructions. The ambient air inside the enclosure must not exceed 60 deg C to protect the internal galvanic isolation components from thermal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43668095696986,"sku":"ST3*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/587..jpg?v=1784258698"},{"product_id":"yokogawa-rm81-a-centum-vp-relay-output-module-rm81-a","title":"Yokogawa RM81-A CENTUM VP Relay Output Module RM81*A","description":"\u003ch2\u003eYOKOGAWA RM81*A Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA RM81*A\u003c\/strong\u003e serves as the primary \u003cstrong\u003eRM81-A\u003c\/strong\u003e Relay Output Module utilized to execute discrete output signals across CENTUM VP platforms. The module manages physical contact state changes to actuate interlocks, alarms, and external field devices via discrete dry contact interfaces. Integrated diagnostic circuits track electrical execution status directly through localized light-emitting diodes (LEDs) positioned on the faceplate assembly, enabling localized verification of channel transitions and coil status without interruption to the primary controller communication backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRM81*A (RM81-A \/ RM81A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 25 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CS 3000, CENTUM XL, MICRO XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 relay output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDry contact relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 2 A, 120 VAC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (channel-to-system, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators for channel ON\/OFF and fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant operation supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mounted (FCU slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Analog Loop Execution\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA RM81*A\u003c\/strong\u003e provides structured galvanic isolation rated at 1500 VAC for 1 minute between the internal low-voltage logic bus and the external electrical field connections. To maintain total signal loop integrity within multi-channel environments, the module enforces structural channel-to-channel isolation that limits noise coupling and blocks voltage spikes from passing backwards into the main processing core. Integrated circuit layouts suppress transient contact arcing during high-frequency switching operations, preserving the linearity and response thresholds of associated 4-20 mA HART loop protocol instruments operating within the same enclosure architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle output state transitions during a primary processor failure in a dual-redundant configuration?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes dual-redundant control paths routed through the FCU slot backplane. When the primary control node drops its active transmission sequence, the tracking secondary module matches the contact states within strict millisecond parameters, keeping the dry contacts closed or open without dropping the field load.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation restrictions concerning the hot-swap function for this module?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping requires the redundant partner card to be fully online and displaying normal status indications. The field technician must ensure that no active interlock loops are cycling during the extraction phase to prevent spurious trips caused by mechanical contact bounce.\u003c\/p\u003e\n\u003cp\u003eQ: Why does the technical data sheet reflect alternative mechanical weight parameters?\u003c\/p\u003e\n\u003cp\u003eA: The standard base module weight sits at approximately 0.35 kg when installed as a bare board within the card cage. Sub-assembly variations that incorporate heavy-duty field terminal adapters or integrated mounting brackets increase the net mass to approximately 1.25 lbs (~0.57 kg).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Insertion:\u003c\/strong\u003e Align the module frame with the dedicated vertical slots of the FCU rack. Press the card firmly until the backplane pins are fully engaged, and secure the mechanical locking tabs to prevent vibration-induced displacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Terminations:\u003c\/strong\u003e Connect all external control loop shields to the designated instrumental grounding bar of the enclosure. Ensure that no loop shields are tied to ground at multiple locations to avoid circulating currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Cables:\u003c\/strong\u003e Route the discrete relay terminal wires through separate conduits away from high-voltage motor starters and low-voltage analog signal cables to maintain electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Boundaries:\u003c\/strong\u003e Maintain clear spatial margins at the ventilation intake paths of the rack chassis. Ensure cabinet cooling parameters keep the internal temperature below 60 deg C to mitigate thermal fatigue on the relay coils.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43668106543194,"sku":"RM81*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/588.jpg?v=1784258992"},{"product_id":"yokogawa-vi701-s1-centum-vp-communication-interface-card","title":"YOKOGAWA VI701-S1 CENTUM VP Communication Interface Card","description":"\u003ch2\u003eYOKOGAWA VI701-S1 CENTUM VP Vnet\/IP Communication Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA VI701-S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVI701\u003c\/strong\u003e Vnet\/IP Interface Card, operates as a dedicated hardware component for high-speed deterministic control communication and workstation data transfer within CENTUM VP and CS3000 DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVI701-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e106.68 mm x 167.64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 2.5 A (5 W via PCIe bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Slot\u003c\/td\u003e\n\u003ctd\u003ePCI Express x1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP (1 Gbps Full Duplex Gigabit Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eDual RJ45 ports for CAT5e\/CAT6 STP cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003e100 m per segment (station to network switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Diagnostics\u003c\/td\u003e\n\u003ctd\u003eFront bracket LEDs (RDY, RCV, SND, Link\/Activity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Fieldbus Connectivity Characteristics\u003c\/h3\u003e\n\u003cp\u003eProcess engineers install the VI701-S1 communication card into Human Interface Stations (HIS) and Engineering Stations (ENG) to establish low-latency Vnet\/IP real-time network integration. Dual RJ45 Gigabit Ethernet ports execute dual-port network redundancy, maintaining uninterrupted deterministic communication across primary and secondary control buses during physical cable or switch outages. The hardware architecture utilizes hardware-level packet processing to achieve full-duplex 1 Gbps throughput without overloading workstation host CPU resources. Real-time LED indicators continuously display port activity, transmission status, and link health for diagnostic validation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the dual-port redundancy on the VI701-S1 prevent network communication interruption?\u003c\/p\u003e\n\u003cp\u003eA: The card connects simultaneously to independent redundant Vnet\/IP network switches via Bus 1 and Bus 2 ports. Internal controller logic monitors packet delivery in real time, automatically routing traffic through the secondary active path if a cable break or switch failure occurs on the primary bus.\u003c\/p\u003e\n\u003cp\u003eQ: What physical system slot is required to install the VI701-S1 card inside an engineering workstation?\u003c\/p\u003e\n\u003cp\u003eA: The card installs into a standard PCI Express x1 slot on the workstation motherboard. Power is drawn directly from the 5 VDC PCIe bus, consuming up to 5 W without requiring auxiliary internal power cables.\u003c\/p\u003e\n\u003cp\u003eQ: What cable specifications ensure reliable 1 Gbps signal integrity across 100-meter segment runs?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must use CAT5e or CAT6 shielded twisted pair (STP) copper cabling with standard RJ45 connectors. The cable shielding must be grounded at the patch panel or network switch enclosure to protect high-frequency data streams against external electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eField technicians must switch off workstation host power and attach an ESD grounding wrist strap before opening the computer chassis. Insert the VI701-S1 card into a designated PCI Express x1 motherboard slot, pressing down firmly until the connector edge seats completely into the slot housing. Secure the metal mounting bracket to the computer frame using a retaining screw to establish structural grounding. Connect dual CAT6 STP cables to the primary and secondary RJ45 ports, ensuring the latch connectors click into place. Route network cables away from high-voltage AC lines, keeping environmental temperatures around the computer enclosure strictly between 0 deg C and +50 deg C.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43791461580890,"sku":"VI701 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/736.1.jpg?v=1785980486"},{"product_id":"sb401-10-s1-yokogawa-centum-cs-esb-bus-interface-card","title":"SB401-10-S1 YOKOGAWA CENTUM CS ESB Bus Interface Card","description":"\u003ch2\u003eYOKOGAWA SB401-10-S1 CENTUM ESB Bus Interface Slave Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed ESB bus communication in CENTUM CS and CENTUM VP platforms, the \u003cstrong\u003eYOKOGAWA SB401-10-S1\u003c\/strong\u003e (\u003cstrong\u003eSB401\u003c\/strong\u003e ESB Bus Interface Slave Module) provides direct physical\/electrical execution for interconnecting Field Control Units (FCU) to downstream Node Units.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSB401-10-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32.8 mm x 143 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power from FIO Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus (Slave Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e128 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transmission Distance\u003c\/td\u003e\n\u003ctd\u003e10 m (ESB bus cable run)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration (installed in paired slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eField engineers deploy the SB401-10-S1 module within FIO Node Units (such as ANB10D or ANB10S) or Base Plate A2BE2D assemblies to maintain real-time data link integrity over the 128 Mbps ESB bus. Paired with EC401 or EC402 ESB Bus Coupler Modules, the hardware facilitates high-speed signal passing between central controllers and up to 9 connected node units. Galvanic and electrical shielding across the backplane bus isolates high-frequency digital noise and voltage spikes, ensuring stable 4-20 mA HART loop protocol communications, fieldbus telemetry, and IO channel processing without logic degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical adapter hardware is required to complete the external ESB bus cabling on the SB401-10-S1?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an ESB Bus Adapter (A2EE1A). Depending on the node's position in the topology, technicians fit either the connector version (A2EE1A-N) for pass-through cabling or the terminator version (A2EE1A-T) for end-of-line bus termination.\u003c\/p\u003e\n\u003cp\u003eQ: How is dual-redundant bus operation configured using the SB401-10-S1 module?\u003c\/p\u003e\n\u003cp\u003eA: Dual-redundancy requires two identical SB401-10-S1 modules installed in dedicated B1 and B2 slots of the FIO Node Unit. In single non-redundant setups, the module populates slot B1 while a dedicated dummy cover protects slot B2.\u003c\/p\u003e\n\u003cp\u003eQ: What happens to bus communication if one module fails in a dual-redundant pair?\u003c\/p\u003e\n\u003cp\u003eA: The slave node architecture detects signal loss or hardware fault on the active channel and automatically switches control traffic to the standby module without interrupting 128 Mbps I\/O data transmission to the Field Control Unit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify that node rack power is disabled and proper ESD grounding precautions are in place before inserting the SB401-10-S1 module into slot B1 or B2. Align the module housing with the node chassis guide rails and push firmly until the backplane connector seats completely. When configuring a single non-redundant node, always install a protective dummy cover over the unused B2 slot to prevent thermal bypass and dust accumulation. Ensure the external ESB bus cable length does not exceed the maximum 10-meter limit between nodes, and install the A2EE1A-T termination adapter at the final bus drop to prevent signal reflections. Maintain passive cabinet airflow to ensure ambient operating temperatures remain between 0 deg C and +55 deg C.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43791461941338,"sku":"SB401-10 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/737.1.jpg?v=1785980694"},{"product_id":"communication-interface-module-yokogawa-vf701-s2-centum-vp","title":"Communication Interface Module | YOKOGAWA VF701-S2 CENTUM VP","description":"\u003ch2\u003eYOKOGAWA VF701-S2 CENTUM VP Vnet\/IP Interface Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA VF701-S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVF701\u003c\/strong\u003e Vnet\/IP Interface Card, operates as a dedicated hardware component for deterministic real-time communication within CENTUM VP control network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVF701-S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22 mm x 124 mm x 126 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard PCI bus power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003ePCI expansion slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP real-time control network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStation Compatibility\u003c\/td\u003e\n\u003ctd\u003eHuman Interface Station (HIS), Engineering Station (ENG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Requirements\u003c\/td\u003e\n\u003ctd\u003eCore2 Duo min 2.13 GHz \/ Xeon Dual Core min 2.0 GHz CPU, 6 GB RAM, 20 GB free HDD space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eEngineers install the VF701-S2 interface module into workstation PCI expansion slots to interface host processing units directly with the Vnet\/IP control network. Operating over standard 4-20 mA HART loop protocol parameters and high-speed digital automation buses, the card maintains deterministic data exchange between operator consoles and field control stations. Optical isolation barriers separate host PCI bus lines from field-facing communication physical layers, shielding sensitive processor electronics from transient voltage spikes and high-frequency industrial noise.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What host PC bus interface is required to install the VF701-S2 communication card?\u003c\/p\u003e\n\u003cp\u003eA: The VF701-S2 installs into a standard PCI expansion slot on compatible industrial workstations. The card draws operational power directly through the PCI motherboard connector without requiring external DC auxiliary wiring.\u003c\/p\u003e\n\u003cp\u003eQ: How does the VF701-S2 maintain network integrity during high-traffic DCS operations?\u003c\/p\u003e\n\u003cp\u003eA: Dedicated onboard network controllers offload Vnet\/IP communications protocol processing from the workstation host CPU. This dedicated hardware execution guarantees deterministic packet delivery and prevents message latency under heavy system monitoring loads.\u003c\/p\u003e\n\u003cp\u003eQ: What grounding steps prevent electrical noise from corrupting Vnet\/IP communication?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must firmly lock the card's metallic mounting bracket to the workstation chassis using standard retention hardware. This screw connection establishes a direct low-impedance grounding path to earth, neutralizing electrostatic discharge and electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure workstation main power is completely disconnected and fit an ESD-protective wrist strap before opening the computer chassis. Carefully align the VF701-S2 edge connector with an available PCI slot and press down evenly until the card seats firmly into the socket. Tighten the retaining screw on the rear expansion bracket to secure physical grounding to the computer enclosure. Connect the Vnet\/IP network cable to the external connector, verifying that latching mechanisms engage cleanly. Maintain clear enclosure ventilation paths to keep internal cabinet operating temperatures strictly between 0 deg C and +55 deg C.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43791462793306,"sku":"VF701-S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/738..jpg?v=1785980993"},{"product_id":"eb401-10-s1-yokogawa-centum-vp-bus-interface-module","title":"EB401-10 S1 Yokogawa CENTUM VP Bus Interface Module","description":"\u003ch2\u003eYokogawa EB401-10 S1 Bus Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed deterministic fieldbus communication in CENTUM CS and CENTUM VP distributed control systems, the \u003cstrong\u003eYokogawa EB401-10 S1\u003c\/strong\u003e (\u003cstrong\u003eEB401-10\u003c\/strong\u003e Bus Interface Module) provides direct physical and data link layer execution between the Field Control Unit and peripheral nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEB401-10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 12.7 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W (typical backplane load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS, CENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e128 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003eMax. 10 m (ESB Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFOUNDATION Fieldbus and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module integrates seamlessly within Yokogawa DCS architecture to pass field data including FOUNDATION Fieldbus H1 and 4-20 mA HART protocol frames across the high-speed ESB bus backbone. Internal hardware design incorporates channel-to-channel galvanic isolation and noise-suppression circuitry to protect backplane data integrity against field-side electrical transients and common-mode voltage spikes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is dual redundancy implemented with this module on the backplane?\u003c\/p\u003e\n\u003cp\u003eA: Installing two EB401-10 S1 modules in adjacent designated slots (B1 and B2) establishes a dual-redundant ESB bus link. If a single module is deployed, slot B1 must host the module while slot B2 requires a dummy cover to maintain thermal balance and bus shielding.\u003c\/p\u003e\n\u003cp\u003eQ: What physical bus accessories are required to complete the cable connection to the node unit?\u003c\/p\u003e\n\u003cp\u003eA: Connection requires an ESB Bus Adapter (A2EE1A), which must be configured using either the inline connector variant (A2EE1A-N) or the bus terminator variant (A2EE1A-T) depending on node position within the bus segment topology.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePrior to inserting the module into the base plate or FIO node unit, verify that the system power supply is isolated or that local hot-swap safety protocols are fully satisfied. Align the circuit board edges carefully with the slot guide rails and push the module firmly into the backplane connector until the locking latches engage completely. Ensure all ESB bus signal cables are routed separately from high-voltage AC power wiring and inductive motor leads to prevent electromagnetic interference. Ground the cable shielding at a single dedicated earth point in strict accordance with standard industrial grounding practices.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43791468265562,"sku":"EB401-10 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/739..jpg?v=1785981701"}],"url":"https:\/\/www.spareoil.com\/collections\/yokogawa-network-card.oembed?page=3","provider":"SpareOil Automation","version":"1.0","type":"link"}