{"product_id":"0916nd-foxboro-base-to-base-cable-new-original-stock","title":"0916ND FOXBORO Base-to-Base Cable | New \u0026 Original Stock","description":"\u003ch2\u003eFOXBORO P0916ND I\/A Series Fieldbus Base-to-Base Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFOXBORO P0916ND\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFOXBORO P0916ND\u003c\/strong\u003e Base-to-Base Cable, operates as a dedicated hardware component for 2 Mbps high-speed data interconnection between adjacent Fieldbus Module baseplates within Foxboro I\/A Series DCS networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0916ND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFOXBORO (Invensys \/ Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e2 Mbps Base-to-Base Fieldbus Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series DCS \/ FBM Baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Cable Length\u003c\/td\u003e\n\u003ctd\u003e0.25 meters (25.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Velocity\u003c\/td\u003e\n\u003ctd\u003e2 Mbps deterministic data transfer rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Application\u003c\/td\u003e\n\u003ctd\u003eInter-baseplate communication bus expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Protection\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty low-profile jacketed data bus connector assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Weight\u003c\/td\u003e\n\u003ctd\u003e0.15 lbs ( 0.07 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control and Loop Protocols\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFOXBORO P0916ND\u003c\/strong\u003e data assembly functions as the hardware link that extends the internal 2 Mbps fieldbus backplane across multiple baseplate segments. By establishing low-latency signal continuity, this interconnect component enables synchronous data exchange between processing units and remote Fieldbus Modules (FBMs). The internal multi-conductor balancing controls crosstalk and electromagnetic induction, maintaining the data frame accuracy required to process complex 4-20 mA HART loop protocol lines. This steady transmission line integrity ensures that downstream channel-to-channel and channel-to-bus isolation circuits execute validation routines without experiencing communication drift or packet loss.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the P0916ND bus cable be safely disconnected while the adjacent FBM baseplates are powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Unplugging the base-to-base cable while the system backplane is energized interrupts the 2 Mbps fieldbus trunk, which will instantly drop downstream modules offline and force all dependent control loops into their fail-safe trip states.\u003c\/p\u003e\n\u003cp\u003eQ: How does the short length of the P0916ND cable affect signal propagation and impedance matching on the bus?\u003c\/p\u003e\n\u003cp\u003eA: The 0.25-meter physical footprint is precisely calculated by the factory to minimize transmission line reflections and match the exact characteristic impedance of the Foxboro I\/A Series backplane communication bus.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental shielding properties prevent data corruption across this cable interface?\u003c\/p\u003e\n\u003cp\u003eA: The cable assembly features an integrated braided foil shield that encapsulates the data lines. This construction paths transient high-frequency noise directly to the chassis frame via the baseplate ground tabs, protecting signal frames from ambient interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Keying Alignment\u003c\/strong\u003e: Line up the integrated mechanical alignment keys on the P0916ND plug with the matching receptacle shroud on the baseplate prior to pushing the connector home to prevent pins from bending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLatch Engagement Validation\u003c\/strong\u003e: Push the cable plugs into the baseplate ports until the internal mechanical retention clips click into place, securing the link against typical control cabinet vibrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Constraints\u003c\/strong\u003e: Do not force sharp bends or kinks into the 0.25-meter cable body during close-coupled cabinet routing. Maintain a smooth loop configuration to preserve the integrity of the internal copper wire strands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Continuity\u003c\/strong\u003e: Check that the FBM baseplates themselves are locked to a common low-impedance master ground bus to ensure the braided shielding on the cable drains induced currents efficiently.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43450875871322,"sku":"P0916ND","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/200_93d5cd7f-e6bd-4ef2-8080-006351a42cce.jpg?v=1780554618","url":"https:\/\/www.spareoil.com\/es\/products\/0916nd-foxboro-base-to-base-cable-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}