{"product_id":"140dao85300-schneider-quantum-32-point-ac-discrete-output-module","title":"140DAO85300 Schneider Quantum 32-Point AC Discrete Output Module","description":"\u003ch2\u003eSchneider Electric 140DAO85300 Modicon Quantum Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signaling and control over physical output components in Modicon Quantum automation platform networks, the \u003cstrong\u003eSchneider Electric 140DAO85300\u003c\/strong\u003e (\u003cstrong\u003e140DAO85300\u003c\/strong\u003e AC Discrete Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140DAO85300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eTechnical data not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (0.99 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eTechnical data not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBus current requirement: 320 mA | Power dissipation calculation:\u003c\/p\u003e\n\u003cp\u003e$$$1.60 + (1.0\\text{ V} \\times \\text{total module load current}$$\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd\u003e32 channels (4 groups of 8 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e20-253 V AC (Supply frequency: 47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e2 output words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Output\u003c\/td\u003e\n\u003ctd\u003e300 Vrms for 10 s AC | 400 Vrms for 1 cycle AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e16 A rms per module | 4 A rms per group | 1 A rms per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.88 mA @ 230 V per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.5 ms (state 0 to state 1 and state 1 to state 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eInternal 4 A fuse per group | Internal RC filter per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial PLC Control \u0026amp; Drive Networks Properties\u003c\/h3\u003e\n\u003cp\u003eOperating inside the Modicon Quantum hardware architecture, this high-density AC output block utilizes specific backplane bus communication velocity parameters to cycle field-side loads at critical speeds. The component handles high I\/O density scaling profiles by allocating 32 output channels into 4 electrically isolated groups of 8 channels. It maintains direct firmware flash compatibility with Quantum controllers, enforcing fast response switching thresholds \u0026lt;= 0.5 ms and managing extreme voltage transients (\u003c\/p\u003e\n\u003cp\u003e$$dV\/dt = 400\\text{ V\/ms}$$\u003c\/p\u003e\n\u003cp\u003e) over Profinet \/ EtherNet\/IP deterministic networks without inducing logic jitter or communication bus faults.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the continuous and surge electrical current limitations for an individual output point?\u003c\/p\u003e\n\u003cp\u003eA: Each separate output channel manages a maximum continuous load current of 1 A rms up to 253 V AC. The internal circuit handles an instantaneous surge current rating of up to 2.5 A for a maximum duration of 1 ms.\u003c\/p\u003e\n\u003cp\u003eQ: How does the internal hardware protection shield the discrete output circuits against electrical overloads?\u003c\/p\u003e\n\u003cp\u003eA: The module protects its internal circuitry via a built-in RC filter assigned to each output point to dampen voltage spikes, alongside an integrated 4 A fuse protecting each individual channel group from overcurrent conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What visible diagnostic indicators are available on the faceplate assembly during a fault state?\u003c\/p\u003e\n\u003cp\u003eA: The front panel provides 32 green LEDs for individual output state verification, 1 green LED indicating active backplane bus communication, and 1 red external fault LED (F) that illuminates when the module detects a field-side malfunction or trip.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSeat the 140DAO85300 module into its designated slot position on the Modicon Quantum backplane rack, checking that the rear interface pin array locks fully into the bus power rails. Wire the AC control circuits to the corresponding field terminal connections, strictly observing the 20 to 253 V AC electrical limits and the 4 A rms maximum current threshold per channel group. Maintain physical separation between these high-voltage AC output wires and low-voltage DC communication or signal lines using dedicated panel wire trays to mitigate inductive cross-talk. Ground the chassis frame to the master instrument ground bus bar inside the enclosure to shield the internal logic against electromagnetic interference.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43545395167322,"sku":"140DAO85300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/234_cfda82ea-4c18-42f0-998a-3ad49edc2f39.jpg?v=1782289147","url":"https:\/\/www.spareoil.com\/es\/products\/140dao85300-schneider-quantum-32-point-ac-discrete-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}