{"product_id":"1c31232g02-emerson-ovation-series-datasheet-technical-manual","title":"1C31232G02 Emerson Ovation Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eEmerson 1C31232G02 Ovation Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson 1C31232G02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1C31232G02\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for converting analog signals from field instruments into digital data within Ovation DCS networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1C31232G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.8 x 2.8 x 9.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (rack powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loop, 0-10 VDC voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit or 16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2500 VDC channel-to-backplane isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in fault detection, open-loop monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 samples per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, IEC 61131-2 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation\u003c\/h3\u003e\n\u003cp\u003eThe 1C31232G02 hardware platform implements 2500 VDC galvanic isolation to establish high channel-to-backplane signal integrity and eliminate external electrical noise injection. The subsystem structure supports multi-channel interface configurations optimized for standard 4-20 mA HART loop protocol architectures. Internal circuit tracking uses precise calibration nodes to mitigate thermal offset, maintaining stable A\/D signal sampling thresholds under continuous operational transitions across processing zones.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the open-loop monitoring feature function within the 1C31232G02 module?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostics track signal continuity. When an current signal drops below specified minimums (e.g., \u0026lt;3.6 mA on a 4-20 mA loop), the module reports an open-loop fault directly to the backplane register.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of hot-swapping under powered backplane conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, insertion and removal can occur without interrupting power to adjacent modules, provided that the chassis grounding limits conform to standard Ovation hardware extraction rules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit securely within the standard Ovation I\/O slot to align all backplane connection points properly. Shielded twisted-pair cabling must execute throughout all external instrumentation runs to minimize electromagnetic interference. All field loop cable shields must terminate strictly at the dedicated plant instrumentation ground busbar, avoiding multi-point connections that introduce ground loop distortions. Maintain appropriate horizontal clearances within the enclosure to ensure proper airflow distribution and thermal stabilization.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43484082339930,"sku":"1C31232G02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/451_434d9f84-ab16-4042-b8aa-bc59ebf89512.jpg?v=1781226230","url":"https:\/\/www.spareoil.com\/es\/products\/1c31232g02-emerson-ovation-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}