100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

Configured for displacement measurement in rotating machinery, the Bently Nevada 330101-00-16-10-02-05 (330101 8 mm Proximity Probe) provides direct physical execution of gap-to-voltage conversion for vibration and position monitoring.

Suffix Breakdown & Model Matrix

Option Component Selection Description
Model 330101 3300 XL 8 mm Proximity Probe
Unthreaded Length 00 0 mm
Case Length 16 160 mm
Total Length 10 1.0 m
Connector 02 Miniature coaxial ClickLoc
Agency Approval 05 Approvals required (Region specific)

Hardware Specifications

Parameter Specification
Model 330101-00-16-10-02-05
Brand Bently Nevada
Origin USA
Weight 2.0 kg
Dimensions 8 mm tip diameter, 160 mm case length
Operating Temp -51 deg C to +177 deg C
Power Consumption Driven by 3300 XL Proximitor Sensor
Linear Range 0.25 mm to 2.3 mm

Bently Nevada Mechanical Monitoring and TSI Characteristics

The 330101 probe system relies on precise eddy-current probe scaling to ensure accurate output, typically calibrated to 7.87 V/mm (200 mV/mil). During commissioning, gap voltage validation against -10 VDC targets at the center of the linear range is mandatory to ensure proper operation within the Proximitor sensor's signal envelope. When monitoring rotor dynamics, maintain sufficient probe spacing to facilitate cross-talk suppression and prevent signal interference between adjacent measurement points. All cabling must utilize shielded coaxial conductors to maintain signal integrity across long distances.

Frequently Asked Questions

Q: What is the primary function of the ClickLoc connector in the 3300 XL system?

A: The ClickLoc connector ensures a constant contact impedance for the coaxial signal path and prevents mechanical disconnection due to machine-induced vibration.

Q: Can the 1.0 m cable length be extended?

A: The total system length is fixed at 1.0 m for this part number. Extending the cable beyond the factory-calibrated length for the specific Proximitor sensor will alter the system's sensitivity and frequency response.

Field Installation Guidelines

  1. Mount the probe using the appropriate bracket, ensuring it is perpendicular to the target surface.
  2. Adjust the probe gap until the output voltage measured at the Proximitor terminal matches the required -10 VDC offset.
  3. Tighten the jam nuts securely to lock the probe position, ensuring no movement occurs during high-speed machine operation.
  4. Route the coaxial cable away from high-voltage AC lines or power supply conductors to minimize electromagnetic interference.
  5. Apply silicone-free thread-locking compounds if necessary to secure the probe housing in the mounting hole.