{"product_id":"330103-00-12-10-01-00-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330103-00-12-10-01-00 Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330103-00-12-10-01-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330103\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for proximity and vibration sensing within Bently Nevada 3300 or 3500 Monitoring Systems. The hardware executing the physical displacement verification translates mechanical rotor dynamics into proportional electrical signals via high-frequency eddy-current probe scaling circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-00-12-10-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 metre (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector and Cable Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 mm tip diameter, 120 mm case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven by Proximitor Sensor (Typically 12 mA at -24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Target Scale\u003c\/td\u003e\n\u003ctd\u003e2.0 V\/mm (50 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Calibration\u003c\/h3\u003e\n\u003cp\u003eThe sensor relies on eddy-current probe scaling to precisely match the target material configuration, typically AISI 4140 steel. Proper gap voltage validation must be performed during mechanical setup to ensure the quiescent operation point matches the -10 VDC target within the linear range. Strict impedance matching between the probe, extension cable, and the Proximitor sensor suppresses cross-talk interference and preserves signal integrity across high-frequency rotor dynamics transitions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the consequence of incorrect gap voltage validation during installation?\u003c\/p\u003e\n\u003cp\u003eA: Deviating from the target -10 VDC gap voltage restricts the available linear operating region, leading to premature signal saturation or clipping during dynamic rotor movements.\u003c\/p\u003e\n\u003cp\u003eQ: Can the standard cable be shorted or altered in the field?\u003c\/p\u003e\n\u003cp\u003eA: No. Altering the physical cable length modifies the total electrical length and system capacitance, which de-calibrates the eddy-current probe scaling and invalidates accuracy parameters.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the mechanical mounting bracket provides adequate rigidity to prevent structural resonance from degrading probe readings. Maintain a minimum clearance of 30 mm from adjacent metals to avoid peripheral eddy-current interaction. Thread the probe into the mounting port until the gap voltage registers precisely -10 VDC on the calibrated voltmeter. Hand-tighten the locknut to the recommended torque specification, ensuring the ClickLoc coaxial connector remains clean and dry. Use the integrated connector protector to isolate the physical junction from fluid contaminants.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43580597207130,"sku":"330103-00-12-10-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330103-00-04-10-02-00_e11e5d60-6182-4c6d-a1b6-f0fbe9488220.png?v=1782959096","url":"https:\/\/www.spareoil.com\/es\/products\/330103-00-12-10-01-00-bently-nevada-3300-xl-8-mm-proximity-probe","provider":"SpareOil Automation","version":"1.0","type":"link"}