100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

Configured for non-contacting displacement measurement in 3300 XL Machinery Protection Systems, the Bently Nevada 330104-00-08-10-01-05 (330104 Proximity Probe) provides direct physical/electrical execution. The hardware establishes a high-frequency eddy-current field to track relative distance variances between the probe tip and a target surface, routing raw voltage deviations across an integrated coaxial link back to an external transducer module.

Hardware Specifications

Parameter Specification
Model 330104-00-08-10-01-05
Brand Bently Nevada
Origin U.S.A.
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 303 or 304 stainless steel (SST)
Thread Type 3/8-24 UNF standard thread
Operating Temp -51 to +177 deg C
Power Consumption Passive sensor assembly (excited by external loop power)
Dimensions 80 mm case length, 1.0 meter total cable length
Weight Less than 1.0 kg nominal

Cross-Talk Suppression

When deploying multiple 330104-00-08-10-01-05 probes within the same mechanical plane to monitor rotor dynamics, precise physical spacing is required to maintain cross-talk suppression. Inter-probe spacing must maintain a minimum distance of 40 mm (1.6 inches) between standard 8 mm tips to prevent electromagnetic field overlaps. If spatial restrictions compromise this limit, adjacent high-frequency channels will experience mutual inductance, degrading loop signal integrity and generating false vibration frequencies at the monitoring rack.

Frequently Asked Questions

Q: Can this 1.0-meter total length probe be terminated directly into a 3300 XL monitor?

A: No. The proximity probe must be matched to a corresponding Proximitor Sensor loop length. A 1.0-meter probe requires an intermediate extension cable (e.g., 4.0 meters or 8.0 meters) to complete the tuned impedance loop.

Q: What are the installation implications of the country-specific approval option on this module?

A: The approval suffix dictates specific regional certification listings and electrical compliance markers on the probe housing. The structural design and internal coil configuration remain completely identical to the standard baseline configuration.

Field Installation Guidelines

  • Housing Torque Thresholds: When threading the 80 mm case into its position, clamp the locknut to a maximum torque rating of 33.9 N-m (300 in-lb) to eliminate thread stress.
  • Coaxial Core Protection: Route the 1.0-meter integrated lead path with a minimum mechanical bend radius of 25.4 mm (1.0 inch) to preserve internal copper insulation layers.
  • Electrical Ground Segregation: Ensure the terminal miniature coaxial ClickLoc connector is isolated from structural machinery casing to mitigate potential ground loop disruptions.