{"product_id":"330104-00-08-50-12-00-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330104-00-08-50-12-00 | Bently Nevada | 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eConfigured for non-contacting shaft displacement tracking in 3300 XL Machinery Protection Systems, the \u003cstrong\u003eBently Nevada 330104-00-08-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe) provides direct physical\/electrical execution. The instrument introduces a high-frequency radio frequency field onto a moving conductive shaft target to capture mechanical changes, transferring raw gap impedance modulations over an integrated coaxial transmission line to an external matching Proximitor Sensor.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe (3\/8-24 UNF standard thread)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector and Cable-Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-08-50-12-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Infrastructure\u003c\/td\u003e\n\u003ctd\u003eFluidLoc moisture-resistant coaxial line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive element (excited by external Proximitor loop supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e80 mm case length, 5.0 meters total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg shipping weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC Targets)\u003c\/h3\u003e\n\u003cp\u003eField deployment requires systematic gap voltage validation to anchor the probe within its calibrated linear measurement envelope. During the physical threading process, engineers must adjust the mechanical insertion depth of the 80 mm case relative to the target surface while tracing the electrical output. Aligning the sensor tip to achieve a baseline output of exactly -10 VDC establishes the physical center of the linear calibration span, optimizing signal accuracy for monitoring raw rotor dynamics and enforcing cross-talk suppression against adjacent active measurement channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What technical protection does the FluidLoc cable option provide compared to standard coaxial lines?\u003c\/p\u003e\n\u003cp\u003eA: The option 12 FluidLoc cable features an internal sealing matrix designed to block the capillary migration of process liquids, oil, or moisture through the cable jacket interior if the outer sheath sustains mechanical punctures.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 5.0-meter probe loop be cut or field-spliced to shorten the installation path?\u003c\/p\u003e\n\u003cp\u003eA: No. Coaxial cables for proximity transducers are strictly matched to specific loop electrical lengths. Cutting or field-splicing the lead alters the tuned circuit impedance and invalidates the scale factor of the system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Tightening Limits:\u003c\/strong\u003e Secure the probe case within its mounting port using a calibrated torque wrench, restricting mechanical load to a maximum of 33.9 N-m (300 in-lb) to prevent housing distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Pathway Routing Constraints:\u003c\/strong\u003e Route the 5.0-meter FluidLoc lead with care to maintain a minimum structural bend radius of 25.4 mm (1.0 inch) to preserve internal dielectric geometries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Ground Isolation:\u003c\/strong\u003e The outer metallic body of the miniature coaxial ClickLoc connector joint must be isolated from the machine structure. Do not ground the cable shield at the machine casing; routing loops must reference the instrument rack enclosure ground exclusively.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43585419378778,"sku":"330104-00-08-50-12-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330104-00-08-05-02-00_94d8a9dd-d33b-4744-8c2a-e2cb4da109e6.png?v=1783048665","url":"https:\/\/www.spareoil.com\/es\/products\/330104-00-08-50-12-00-bently-nevada-3300-xl-8-mm-proximity-probe","provider":"SpareOil Automation","version":"1.0","type":"link"}