Configured for non-contacting displacement and vibration measurements in 3300 XL Proximity Transducer System networks, the Bently Nevada 330105-02-12-05-02-01 (330105 Reverse Mount Probe) provides direct physical/electrical execution.
| Parameter | Specification |
|---|---|
| Model | 330105-02-12-05-02-01 |
| Brand | Bently Nevada |
| Origin | U.S.A. |
| Weight | 0.350 kg nominal |
| Dimensions | 8 mm probe tip diameter, M10 x 1 thread size, 12 ft (3.6 m) cable length |
| Operating Temp | -35 deg C to +100 deg C |
| Power Consumption | Sourced via matched external 3300 XL Proximitor Sensor loop |
| Measurement Principle | Eddy current displacement measurement |
| Output Signal | Voltage proportional to displacement (7.87 V/mm / 200 mV/mil) |
| Frequency Response | DC to 10 kHz |
| System Length | 5 m system matching criteria (probe + extension cable) |
The 330105-02-12-05-02-01 assembly uses an inverse hardware orientation to execute eddy-current probe scaling against a target machine shaft via an 8 mm probe tip. Accurate transduction across the DC to 10 kHz frequency spectrum requires proper local gap voltage validation during positioning. Mechanical adjusters must manipulate the reverse mount insertion depth until the static electrical output at the Proximitor sensor measures the specific -10 VDC targets. This anchors the physical gap at the linear center of the 200 mV/mil voltage loop. Proper calibration ensures that dynamic rotor dynamics are recorded without signal saturation, while integrated shielding architecture guarantees cross-talk suppression between radial-orthogonal sensor pairings.
Q: How does the specific 12 ft (3.6 m) cable length influence total system impedance matching?
A: The transducer loop demands an exact electrical length to maintain a linear 200 mV/mil output. This 3.6 m probe must be integrated into a standard 5 m total system length using the correct matched extension cable; swapping with components intended for 9 m systems invalidates the calibrated eddy-current probe scaling.
Q: What failure mode occurs if fluid contaminants bypass the coaxial connection insulation?
A: Ingress of water, oil, or conductive cutting fluids at the ClickLoc junction alters the nominal line impedance. This induces drift during gap voltage validation, limits high-frequency response, and compromises cross-talk suppression.