{"product_id":"adv151-p63-s2-yokogawa-centum-vp-digital-input-module","title":"ADV151-P63 S2 Yokogawa CENTUM VP Digital Input Module","description":"\u003ch2\u003eYokogawa ADV151-P63 S2 Digital Input Modules\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete status acquisition in CENTUM VP and ProSafe-RS control platforms, the \u003cstrong\u003eYokogawa ADV151-P63 S2\u003c\/strong\u003e (\u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution. The module processes binary field inputs across dedicated channels to update system logic blocks. Featuring 2000 VAC system isolation, status display indicators, and ISA Standard G3 conformal coating, the module maintains continuous signal supervision across redundant DCS communication backplanes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P63 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 - 0.45 kg (1.5 kg shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa I\/O module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C (G3 standard compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e400 mA (5 VDC), 200 mA (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 \/ 32 channels (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Thresholds\u003c\/td\u003e\n\u003ctd\u003eON: 18 to 26.4 VDC; OFF: \u0026lt;= 5.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/- 20% per channel (at rated voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Permissible Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 8 ms (for status input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC between input signal and system logic for 1 minute; 500 VAC between commons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eYokogawa DCS architectures require electrical isolation to protect central control units from field-side electrical surges. The ADV151-P63 S2 module provides 2000 VAC withstand galvanic isolation between field signal connections and internal backplane processing logic, alongside 500 VAC channel group isolation. When operating in hybrid control cabinets alongside 4-20 mA HART analog loops, this high dielectric withstand capability mitigates cross-talk and ground loop currents, ensuring signal integrity across adjacent control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input voltage thresholds determine the logic states for the ADV151-P63 module? A: The module records a valid logic ON state between 18 and 26.4 VDC, and transition to a logic OFF state occurs at or below 5.0 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation ratings apply between field signal groups and internal logic buses? A: The hardware withstands 2000 VAC for 1 minute between field terminals and system logic circuits, and 500 VAC for 1 minute between internal common groups.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ADV151-P63 support hot-swapping during active control execution? A: Yes, when configured within a dual-redundant I\/O architecture, operators can replace the module online without disrupting system logic execution or adjacent channel signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect loop power or verify active execution of the redundant partner module before inserting or removing hardware from the rack slot.\u003c\/li\u003e\n\u003cli\u003eConfirm that physical alignment pins on the module base engage properly with the backplane connector to prevent mechanical pin deformation.\u003c\/li\u003e\n\u003cli\u003eFasten field wiring connectors or interface cable adapters using standard torque specs to ensure stable electrical connections.\u003c\/li\u003e\n\u003cli\u003eRoute low-voltage DC input wires through dedicated wire raceways separated from high-voltage AC conductors to reduce inductive coupling.\u003c\/li\u003e\n\u003cli\u003eConnect cable shield drain wires directly to the cabinet protective earth bar using short, low-impedance grounding conductors.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43787399659610,"sku":"ADV151-P63","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/722..jpg?v=1785898094","url":"https:\/\/www.spareoil.com\/es\/products\/adv151-p63-s2-yokogawa-centum-vp-digital-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}