{"product_id":"aip444-s1-yokogawa-centum-vp-analog-input-module","title":"AIP444-S1 YOKOGAWA  CENTUM VP Analog Input Module","description":"\u003ch2\u003eYOKOGAWA AIP444-S1 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-accuracy signal acquisition in CENTUM VP FIO network platforms, the \u003cstrong\u003eYOKOGAWA AIP444-S1\u003c\/strong\u003e (\u003cstrong\u003eAIP444-S1\u003c\/strong\u003e Analog Input Module) provides direct physical and electrical execution of multi-channel analog monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIP444-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 25 x 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 to 8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Connectivity and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module operates within the CENTUM VP Field I\/O (FIO) architecture, interfacing directly with the Field Control Unit (FCU) to execute deterministic sampling. To ensure data integrity, the design implements rigorous channel-to-channel isolation and channel-to-backplane isolation, effectively suppressing common-mode interference in high-density installations. Integrated diagnostics perform continuous module health monitoring and open-circuit detection, providing real-time status updates to the controller via the backplane bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary isolation requirements for the AIP444-S1 signal inputs?\u003c\/p\u003e\n\u003cp\u003eA: The module provides channel-to-channel and channel-to-backplane isolation to prevent ground loops. Shielding must be terminated correctly at the cabinet entry point to maintain this galvanic separation during signal transition.\u003c\/p\u003e\n\u003cp\u003eQ: Is the AIP444-S1 hot-swappable within the FIO node unit?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for use in FIO baseplates (A2BE1D\/A2BE2D). While physical insertion is supported, verify the specific node configuration and CPU redundancy status before extraction to prevent control loop interruptions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Align the module with the designated slot on the A2BE1D or A2BE2D baseplate. Ensure the connector pins are fully engaged and secure the module using the integrated locking mechanisms to prevent vibration-induced disconnects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Utilize high-quality shielded twisted-pair cabling for all 4-20 mA loops. Route signal cables away from high-voltage AC lines to maintain signal-to-noise ratios. Always terminate cable shields at the dedicated grounding bus, not the module housing, to optimize noise immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Given the power dissipation of 6 to 8 W, verify that the cabinet ventilation system maintains ambient temperatures within the 0 deg C to +55 deg C range to prevent accelerated component aging.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43601674371162,"sku":"AIP444 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/458._e1ae2478-f25b-46ff-8d82-7a0e308a9110.jpg?v=1783310357","url":"https:\/\/www.spareoil.com\/es\/products\/aip444-s1-yokogawa-centum-vp-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}