{"product_id":"analog-input-module-with-hart-pass-through-yokogawa-asi133-h00-s1","title":"Analog Input Module with HART Pass-through YOKOGAWA ASI133-H00 S1","description":"\u003ch2\u003eYOKOGAWA ASI133-H00 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density signal acquisition in hazardous area control networks, the \u003cstrong\u003eYOKOGAWA ASI133-H00\u003c\/strong\u003e (\u003cstrong\u003eASI133-H00\u003c\/strong\u003e Analog Input Module) provides direct physical signal interface with integrated intrinsic safety for Zone 1\/Division 1 instrumentation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eASI133\u003c\/td\u003e\n\u003ctd\u003e8-Channel Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-H00\u003c\/td\u003e\n\u003ctd\u003eStandard Configuration with HART pass-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASI133-H00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 12.7 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA @ 5 VDC, 450 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe ASI133-H00 features channel-to-channel and channel-to-system electrical isolation, which eliminates common-mode noise interference in complex field wiring layouts. By incorporating dedicated intrinsic safety (Ex i) barriers directly into the module architecture, the device maintains rigorous isolation from hazardous area potential. It supports full HART protocol transparency, allowing for seamless digital communication overlay on the 4-20 mA loop. This design enables real-time device diagnostics and remote parameter configuration without impacting the primary control loop's signal latency or integrity. Cold junction compensation is handled via the integrated signal conditioning circuitry, ensuring stability across the specified operating temperature range.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ASI133-H00 support field-side power supply for 2-wire transmitters?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module provides a transmitter power supply (\u0026gt;= 16 VDC, max 20 mA per channel) required for powering 2-wire loops directly from the input terminals.\u003c\/p\u003e\n\u003cp\u003eQ: Are the channels hot-swappable during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Maintenance procedures should strictly follow the specific system cabinet guidelines. While the module is designed for industrial durability, input loops must be verified as de-energized or set to \"Maintenance Mode\" in the DCS\/SIS software prior to physical module extraction to avoid potential signal jumps.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e To ensure the efficacy of the built-in intrinsic safety barriers, the module chassis must be connected to a high-integrity instrument earth ground. Ensure impedance to ground is within specified limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted-pair cables for signal runs. Terminate cable shields at the designated ground bar near the entry point of the cabinet to minimize EMI\/RFI ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Separation:\u003c\/strong\u003e Maintain rigid separation between intrinsically safe (IS) wiring and non-IS wiring. Keep cables bundled in separate trays or conduits to prevent cross-coupling of high-energy transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Given the power consumption characteristics, ensure the module is installed in a rack with sufficient vertical clearance to allow for passive convection airflow, preventing localized hotspots.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43582680432730,"sku":"ASI133-H00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/127._93aa6620-ef7c-4c19-afda-81f1158f7d24.jpg?v=1782981706","url":"https:\/\/www.spareoil.com\/es\/products\/analog-input-module-with-hart-pass-through-yokogawa-asi133-h00-s1","provider":"SpareOil Automation","version":"1.0","type":"link"}