{"product_id":"analog-input-modules-triconex-8300a-tricon-3000-series","title":"Analog Input Modules | Triconex 8300A Tricon 3000 Series","description":"\u003ch2\u003eTriconex 8300A Tricon 3000 Series Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal processing and electrical voltage distribution in Tricon 3000 Series SIS platforms, the \u003cstrong\u003eTriconex 8300A\u003c\/strong\u003e (\u003cstrong\u003e8300A\u003c\/strong\u003e Analog Input \/ Power Module) provides direct physical\/electrical execution. The component executes real-time data acquisition from field transmitters alongside secondary power monitoring subroutines within the rack backplane matrix.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg (4.95 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e177.8 mm x 101.6 mm x 228.6 mm (Alternative chassis: 49 cm x 45.3 cm x 6.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C (Extended limits: -40 to +85 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 W maximum output \/ 24 VDC nominal loop power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loop (standard); configurable for voltage ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003e2500 V RMS channel-to-channel and channel-to-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC nominal, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL3, IEC 61511, TÜV, CE, UL Class I Div 2, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy and Fail-Safe Execution\u003c\/h3\u003e\n\u003cp\u003eThe module hardware uses a triple modular redundancy (TMR) 2oo3 architecture paired with internal voter logic circuitry to achieve continuous fail-safe state execution. Three separate logic legs handle concurrent processing of the incoming 4-20 mA loops, cross-checking values to eliminate single-point hardware faults. 2500 V RMS galvanic isolation protects the subsystem by separating the channel-to-channel and channel-to-backplane conductive paths. These structural diagnostic layers allow the module to maintain active state operation and safety loops under strict IEC 61508 SIL3 certification parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the physical operational limitations during a hot-swap procedure?\u003c\/p\u003e\n\u003cp\u003eA: The module supports online hot-swap operations within a single-slot rack allocation. The replacement procedure must execute while the system is energized, allowing the backup or adjacent redundant channels to manage the processing loop during the physical swap without causing shutdown initialization.\u003c\/p\u003e\n\u003cp\u003eQ: How does the channel isolation network respond to inductive voltage spikes from field wiring?\u003c\/p\u003e\n\u003cp\u003eA: The input architecture employs independent galvanic isolation rated at 2500 V RMS. This physical barrier stops transient overvoltages and common-mode noise from entering the internal backplane logic arrays.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module vertically inside the designated single-slot position of the Tricon 3000 Series SIS rack. Confirm the guide pins route securely into the backplane sub-assembly before tightening the module retention screws. Field personnel must terminate all 4-20 mA instrument lines at the corresponding termination baseplate. Apply continuous cable shielding and low-impedance grounding across all analog loops to minimize electromagnetic interference (EMI). Route all low-level signal cables through dedicated wiring ducts separate from high-voltage AC lines inside the cabinet.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":43736137957466,"sku":"8300A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/193._49d5d293-61de-4b48-bffe-85ab837531ec.jpg?v=1785115210","url":"https:\/\/www.spareoil.com\/es\/products\/analog-input-modules-triconex-8300a-tricon-3000-series","provider":"SpareOil Automation","version":"1.0","type":"link"}