{"product_id":"bently-nevada-330130-070-00-05-3300-xl-series-extension-cable","title":"Bently Nevada 330130-070-00-05 3300 XL Series Extension Cable","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330130-070-00-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330130\u003c\/strong\u003e Extension Cable, operates as a dedicated hardware component for RF signal transmission within 3300 XL Proximitor Sensor networks. It acts as the electrical link connecting an eddy-current proximity probe to a remote transducer module, maintaining analog measurement loop parameters without introducing uncompensated impedance mismatches or signal phase shifts.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330130\u003c\/strong\u003e - Base Model: 3300 XL Standard Extension Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-070\u003c\/strong\u003e - Cable Length Option: 7.0 metres (23.0 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e - Connector Protector and Cable Option: Standard cable (non-armored)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e - Agency Approval Option: Multiple Approvals (CSA, ATEX, IECEx for hazardous locations)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-070-00-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.3 cm x 3.2 cm x 10.0 cm (coiled envelope dimensions); 7.0 m physical cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.0 W (Passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Impedance\u003c\/td\u003e\n\u003ctd\u003e75.0 ohm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe physical construction of the 330130-070-00-05 extension cable provides strict shielding geometry necessary to preserve calibrated eddy-current probe scaling over the 7.0 m distance. This continuous coaxial shielding configuration ensures high-frequency cross-talk suppression when routed in proximity to adjacent machine instrumentation. Stabilizing the transmission path parameters enables consistent gap voltage validation, targeting the traditional nominal -10 VDC baseline across standard rotor dynamics monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this 7.0 m extension cable be interchanged with a 4.5 m cable within a standard calibrated loop?\u003c\/p\u003e\n\u003cp\u003eA: No. Proximitor sensors are engineered for an exact total system electrical length (typically 5.0 m or 9.0 m). Swapping a 7.0 m cable into a loop tuned for a different parameter changes total circuit capacitance and invalidates the transducer calibration profile.\u003c\/p\u003e\n\u003cp\u003eQ: What physical protection does this non-armored (-00 option) cable require when routed near raw mechanical parts?\u003c\/p\u003e\n\u003cp\u003eA: Because the -00 option designates a standard non-armored jacket, the cable lacks native resistance to crushing or shearing. It must be installed inside grounded structural conduits or liquid-tight junction boxes to shield the inner dielectric from distortion.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the combined electrical length of the proximity probe and the extension cable matches the fixed calibration specification printed on the Proximitor sensor label.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum static bend radius of 25.4 mm along the entire routing sequence to prevent permanent physical changes to the coaxial impedance structure.\u003c\/li\u003e\n\u003cli\u003eIsolate all miniature coaxial connectors from structural metalwork and conduits by fully deploying the specialized installation sleeves or applying self-fusing electrical insulation tape.\u003c\/li\u003e\n\u003cli\u003eRoute the non-armored line exclusively through dedicated low-voltage instrumentation channels to prevent external electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43650563211354,"sku":"330130-070-00-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330130-070-00-05.png?v=1783929027","url":"https:\/\/www.spareoil.com\/es\/products\/bently-nevada-330130-070-00-05-3300-xl-series-extension-cable","provider":"SpareOil Automation","version":"1.0","type":"link"}