{"product_id":"centum-cs3000-analog-input-card-yokogawa-aam50-s1","title":"CENTUM CS3000 | Analog Input Card YOKOGAWA AAM50-S1","description":"\u003ch2\u003eYOKOGAWA AAM50-S1 CENTUM Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density 16-channel analog signal acquisition in CENTUM CS\/CS3000 platforms, the \u003cstrong\u003eYOKOGAWA AAM50-S1\u003c\/strong\u003e (\u003cstrong\u003eAAM50\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution for process transmitter loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAM50-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e76 mm x 25 mm x 178 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC via backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signals\u003c\/td\u003e\n\u003ctd\u003eCurrent (4-20 mA DC, 0-20 mA DC), Voltage (0-10 VDC, +\/-10 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit \/ 16-bit ADC conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VDC (input to output logic) \/ 1500 VAC (channel-to-ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eEngineers utilize the AAM50-S1 module to capture high-density field transmitter telemetry across Field Control Stations (PFCS\/PFCD) via the 4-20 mA HART loop protocol. Integrated galvanic isolation rated at 1500 VDC breaks ground loops and isolates field-side electrical surges from the internal system backplane. Active noise filtering suppresses high-frequency electromagnetic interference (EMI) across all signal paths before digitizing. Internal health diagnostics continuously monitor loop wiring to detect open circuits, signal over-range conditions, and analog-to-digital converter execution status.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle fault isolation during field wiring short circuits?\u003c\/p\u003e\n\u003cp\u003eA: Optical and transformer galvanic isolation barriers rated at 1500 VDC prevent high-voltage electrical faults on field wiring terminals from migrating across the backplane connector, keeping the central processor node operational.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting options support the physical installation of the AAM50-S1 card?\u003c\/p\u003e\n\u003cp\u003eA: Installers insert the module directly into standard CENTUM Node Interface Units (NIU), Field Control Station nests, or I\/O expansion racks via integrated backplane guide rails and connector slots.\u003c\/p\u003e\n\u003cp\u003eQ: How do internal diagnostics communicate signal faults to the central control processor?\u003c\/p\u003e\n\u003cp\u003eA: Diagnostic routines scan each channel for wire breaks, out-of-range current\/voltage thresholds, and internal hardware faults, setting system status flags that transmit across the 5 VDC backplane bus directly to the DCS database.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInspect the target slot inside the Node Interface Unit or I\/O rack for debris before inserting the module card edge. Slide the card firmly along the slot guide rails until the backplane connector locks completely into position. Wire field loops using shielded twisted-pair cabling, terminating all cable shields at a dedicated cabinet earth bus bar to eliminate ground potential loops. Avoid running field signal wires in close proximity to high-voltage AC power distribution lines or frequency drives. Maintain proper cabinet air circulation to keep the ambient enclosure temperature strictly between 0 deg C and +55 deg C during continuous operation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43791461253210,"sku":"AAM50-S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/735.jpg?v=1785980095","url":"https:\/\/www.spareoil.com\/es\/products\/centum-cs3000-analog-input-card-yokogawa-aam50-s1","provider":"SpareOil Automation","version":"1.0","type":"link"}