{"product_id":"digital-output-module-ics-triplex-t8513-trusted","title":"Digital Output Module | ICS Triplex T8513 Trusted","description":"\u003ch2\u003eICS Triplex T8513 Trusted Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for specific technical task in Trusted TMR safety systems, the \u003cstrong\u003eICS Triplex T8513\u003c\/strong\u003e (\u003cstrong\u003eT8513\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. The module drives a single-channel 24 VDC output rated at 1 A to command safety-critical field field actuators, solenoids, and interposing relays. Operating directly within the Triple Modular Redundant architecture, the hardware components process logic commands while executing continuous diagnostic fault monitoring and enforcing a 500 V electrical isolation barrier between the internal system backplane and external field loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8513\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified (backplane draw dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V between system and field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eReal-time internal loop fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eTrusted TMR safety systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-swappable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 percent to 95 percent, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy \u0026amp; Safety Execution\u003c\/h3\u003e\n\u003cp\u003eThe T8513 architecture integrates directly with the triple modular redundancy (TMR) 2oo3 architecture voting mechanisms of the host safety platform. The module establishes systemic galvanic isolation up to 500 V across its electronic boundaries to interrupt transient faults before they affect control processors. If a component degradation event or loop open\/short condition occurs, the module initiates fail-safe state execution to drive the field channel into a designated de-energized or defined safe state, maintaining overall process boundary safety without false trips.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can an operator execute a hot-swap replacement on the T8513 module during active process operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports live online hot-swap insertion and extraction, allowing maintenance technicians to exchange components without removing power from the active rack or shutting down the process.\u003c\/p\u003e\n\u003cp\u003eQ: What specific field devices does the 24 VDC, 1 A channel output typically command?\u003c\/p\u003e\n\u003cp\u003eA: The discrete output channel delivers standard 24 VDC power directly mapped to final control elements such as emergency shutdown solenoids, critical process actuators, and safety interposing relays.\u003c\/p\u003e\n\u003cp\u003eQ: How does the integrated diagnostic subsystem handle field wiring anomalies?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostic hardware constantly reads internal loops to verify output line continuity, executing real-time fault detection for field circuit interruptions or overcurrent states, and reporting the health status to the main processor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the module chassis guides precisely with the active slot rails within the Trusted rack enclosure during physical insertion.\u003c\/li\u003e\n\u003cli\u003eEnforce the 500 V isolation parameters by ensuring that all field wiring bundles remain segregated from low-voltage logic cables inside the panel ducts.\u003c\/li\u003e\n\u003cli\u003eConnect the field loop return lines using dedicated terminal blocks, ensuring single-point reference grounding schemas to counter electrical noise.\u003c\/li\u003e\n\u003cli\u003eConfirm that the ambient temperature inside the sealed enclosure remains below 55 deg C through appropriate panel ventilation layout.\u003c\/li\u003e\n\u003cli\u003eVerify that terminal connection screws are torqued down to standard industrial parameters to prevent loose contact points on high-vibration platforms.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":43753201074266,"sku":"T8513","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/221._02f7ea67-f0a0-4f5f-84ac-5f8aed977a6f.jpg?v=1785287187","url":"https:\/\/www.spareoil.com\/es\/products\/digital-output-module-ics-triplex-t8513-trusted","provider":"SpareOil Automation","version":"1.0","type":"link"}