{"product_id":"duplexed-safety-control-unit-dcs-yokogawa-ssc60d-f2542","title":"Duplexed Safety Control Unit DCS Yokogawa SSC60D-F2542","description":"\u003ch2\u003eYokogawa SSC60D-F2542 Duplexed Safety Control Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-availability process control in CENTUM VP and Vnet\/IP platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SSC60D-F2542\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eSSC60D-F2542\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuplexed Safety Control Unit) provides direct physical signal processing and redundant execution for distributed control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebase model designates the duplexed safety control unit architecture designed for rack-mounted installations. The suffix code breakdown for the specific\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D-F2542\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is defined as follows:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eF\u003c\/strong\u003e: Indicates hardware revision\/variant specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2\u003c\/strong\u003e: Dual-redundant power supply configuration for primary and secondary power rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5\u003c\/strong\u003e: Standard assembly without specific explosion protection certification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4\u003c\/strong\u003e: 220–240 V AC power supply input module requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2\u003c\/strong\u003e: Base control unit variant without specific Safety Control Function licenses (compatible with R4.01 or later system software).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSSC60D-F2542\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack Mountable Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +40 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant input requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVnet\/IP Deterministic Network\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D-F2542\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes channel-to-channel isolation and galvanic separation to maintain process integrity across complex control loops. To facilitate accurate data acquisition, the unit manages 4-20 mA HART loop protocol connectivity, allowing for seamless integration with smart transmitters and diagnostic analyzers. The architecture supports internal cold junction compensation (CJC) logic for analog input modules connected to the local bus, ensuring precision in temperature-sensitive control environments. Furthermore, the duplexed design incorporates high-speed synchronization interfaces to ensure bumpless transfer during primary-to-secondary controller failover events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the power supply units be hot-swapped while the controller is active?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the dual-redundant power supply configuration supports the removal and replacement of individual power modules without interrupting the execution of the control logic, provided the secondary power rail remains energized.\u003c\/p\u003e\n\u003cp\u003eQ: How does the lack of a Safety Control Function license affect module operation?\u003c\/p\u003e\n\u003cp\u003eA: The base unit without the specific Safety Control Function license operates as a standard DCS controller. It executes routine regulatory control tasks but cannot perform logic functions explicitly reserved for SIL-rated safety instrumented systems.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the controller within a standard 19-inch instrumentation rack. Ensure that the chassis ground is bonded to the cabinet main earth bar using a low-impedance copper conductor to mitigate common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries requires adequate airflow. Maintain a minimum clearance of 50 mm above and below the unit to prevent thermal throttling, as the operating range is restricted to -20 deg C to +40 deg C for this specific standard configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Cabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect 220–240 V AC sources to the redundant power inputs. Utilize independent circuit protection for each feed to ensure that a localized short circuit does not compromise both power rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll I\/O cabling must utilize shielded twisted-pair conductors. Terminate shields at the cabinet-specific terminal block to minimize the ingress of EMI\/RFI, which could degrade A\/D conversion accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43612014051418,"sku":"SSC60D-F2542","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/428.1_256b3fd5-ff91-4178-8b9b-9a482c031382.jpg?v=1783403337","url":"https:\/\/www.spareoil.com\/es\/products\/duplexed-safety-control-unit-dcs-yokogawa-ssc60d-f2542","provider":"SpareOil Automation","version":"1.0","type":"link"}