{"product_id":"f-3dio8-801-hima-himatrix-safety-series-datasheet-technical-manual","title":"F 3DIO8\/801 HIMA HIMatrix Safety Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eHIMA F3DIO8\/801 HIMatrix Safety Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F3DIO8\/801\u003c\/strong\u003e serves as the primary \u003cstrong\u003eF3DIO8\/801\u003c\/strong\u003e Digital Input\/Output (I\/O) Module utilized to execute discrete signal processing across HIMatrix safety platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3DIO8\/801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.6 x 7.7 x 11.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage Range (Inputs)\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay or transistor outputs (depending on configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating (Outputs)\u003c\/td\u003e\n\u003ctd\u003e2 A @ 24 VDC \/ 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in self-test, short-circuit and open-circuit detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508), PLe (EN ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eEthernet, Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, TUV approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh Reliability Safety Control (SIS)\u003c\/h3\u003e\n\u003cp\u003eThe module architecture incorporates SIL3 certification and PLe functional parameters to guarantee safety loop logic validation across all channels. The internal data conversion networks deploy a triple modular redundancy (TMR) 2oo3 architecture voting loop to verify discrete logic states and eliminate transient measurement faults. Complete galvanic isolation rated at 1500 V RMS channel-to-ground suppresses cross-talk and field-side inductive spikes, driving an immediate fail-safe state execution through the processor bus whenever loop thresholds exceed pre-configured safety limits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal monitoring logic respond during an external open-circuit condition?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostic circuits continuously track the line impedance of the digital circuits. Upon detection of an open-circuit path, the module writes a specific fault bit to the controller register and sets the channel to its fail-safe state.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module rated for direct integration with Modbus networks?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the embedded processing architecture natively handles Modbus TCP\/IP and standard Ethernet protocols to broadcast diagnostic and I\/O status data to supervisory networks.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSnap the physical housing assembly securely onto a standard symmetrical DIN-rail, ensuring that the structural mounting clips latch fully onto the metal profile. Field signal wires must be routed inside dedicated, enclosed wiring ducts that are completely isolated from high-voltage 3-phase AC power lines or heavy motor control wiring. All external instrumentation shields must connect to the central safety earth busbar at a single point to prevent the formation of circulating ground paths. Ensure that proper vertical spacing is maintained around the IP20 enclosure to allow unrestricted natural air currents for internal heat dissipation.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43484594110554,"sku":"F3DIO8\/801","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/297_9cd994fa-0ffb-499d-ae5f-778309c0b6a7.jpg?v=1781232579","url":"https:\/\/www.spareoil.com\/es\/products\/f-3dio8-801-hima-himatrix-safety-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}