{"product_id":"ge-fanuc-ic200alg320-versamax-analog-output-module","title":"GE Fanuc IC200ALG320 VersaMax Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200ALG320\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ALG320\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for multi-channel analog current signal generation within VersaMax I\/O platforms. The unit executes digital-to-analog signal conversion across 4 current-sourcing channels, delivering 4-20 mA control signals to field actuators and positioning devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 lbs (0.28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot VersaMax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA max from backplane; 240 mA max external current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e4 analog current-sourcing outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits (4 uA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.3% typical, +\/-1% maximum full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e0.3 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC or 9.6 to 15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eLoss of user side power detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e2 LEDs (FLD PWR and OK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module interfaced through the VersaMax backplane structure operates with a maximum update rate of 0.3 ms, processing 12-bit output directives sent from the CPU or network interface unit. Output channel logic draws up to 50 mA from the internal 5 VDC system bus while utilizing external 12\/24 VDC user side power for field-loop actuation. Upon fault detection or loss of backplane communication, the hardware executes configurable fail-safe states, reverting channels to 4 mA or holding the last valid output state via jumper selection.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200ALG320 require an external power supply to operate field output loops?\u003c\/p\u003e\n\u003cp\u003eA: Yes, while logic power is derived from the 5 VDC backplane bus (50 mA max), the analog output channels require external field power rated at 18 to 30 VDC or 9.6 to 15 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What fail-safe output response modes are available upon CPU stoppage or fault?\u003c\/p\u003e\n\u003cp\u003eA: The module can be configured via jumper settings to either hold the last known output state or drop the output signal to 4 mA.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module indicate operating status and field power presence?\u003c\/p\u003e\n\u003cp\u003eA: The module contains 2 onboard LED indicators: the OK LED confirms backplane power supply and system initialization, while the FLD PWR LED confirms active user side field power.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the module securely onto the VersaMax I\/O rail carrier prior to attaching field termination blocks.\u003c\/li\u003e\n\u003cli\u003eConfirm that backplane logic power is de-energized before inserting or removing the output module.\u003c\/li\u003e\n\u003cli\u003eWire the external 18-30 VDC loop power supply and 4-20 mA field actuators using shielded twisted-pair cables.\u003c\/li\u003e\n\u003cli\u003eGround cable shields at a single ground point on the enclosure grounding bar to suppress noise and prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify output response behavior configurations (Hold Last State vs. 4 mA default) via hardware jumper placement before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796914012250,"sku":"IC200ALG320","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200ALG320.jpg?v=1786091379","url":"https:\/\/www.spareoil.com\/es\/products\/ge-fanuc-ic200alg320-versamax-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}