{"product_id":"ge-fanuc-ic693pwr322-series-90-30-power-supply-module","title":"GE Fanuc IC693PWR322 Series 90-30 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693PWR322\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693PWR322\u003c\/strong\u003e Standard Power Supply, operates as a dedicated hardware component for internal backplane power distribution and DC\/DC conversion within Series 90-30 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693PWR322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 lbs (0.57 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30 power supply slot width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 W with VDC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd\u003e30 Watts total capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eStart: 21 to 56 VDC; Run: 18 to 56 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC Output Power\u003c\/td\u003e\n\u003ctd\u003e15 Watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolated +24 VDC Output\u003c\/td\u003e\n\u003ctd\u003e20 Watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay +24 VDC Output\u003c\/td\u003e\n\u003ctd\u003e15 Watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 A peak, 100 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup \/ Ride-Through Time\u003c\/td\u003e\n\u003ctd\u003e14 ms minimum holdup time; 10 ms minimum ride-through time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Diagnostic LEDs\u003c\/td\u003e\n\u003ctd\u003ePWR, OK, RUN, BATT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485 serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Power Distribution\u003c\/h3\u003e\n\u003cp\u003eThe IC693PWR322 power module delivers stable DC operating voltages across the Series 90-30 backplane, maintaining system backplane bus communication velocity and processing continuity during DC supply line fluctuations. It converts a nominal 24\/48 VDC input into three regulated outputs: +5 VDC logic power, +24 VDC isolated power, and +24 VDC relay power up to a total load of 30 Watts. Firmware flash compatibility and internal diagnostic monitoring are supported through front-panel LEDs (PWR, OK, RUN, BATT) and an integrated RS-485 serial interface. An internal energy storage stage provides a 14 ms minimum holdup time to prevent CPU logic resets under transient power dropouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the input DC voltage operating boundaries for the IC693PWR322?\u003c\/p\u003e\n\u003cp\u003eA: The module requires 21 to 56 VDC to initiate system start-up and continues operation across a running input voltage range of 18 to 56 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How is the maximum output power distributed across the internal supply rails?\u003c\/p\u003e\n\u003cp\u003eA: The module provides up to 30 Watts total output power, divided into +5 VDC logic power (15 W max), isolated +24 VDC power (20 W max), and relay +24 VDC power (15 W max).\u003c\/p\u003e\n\u003cp\u003eQ: What peak inrush current must be accounted for during system power-up?\u003c\/p\u003e\n\u003cp\u003eA: The power supply generates a peak inrush current of 4 A with a maximum duration of 100 ms at initial energization.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate primary field DC power sources before mounting or removing the power supply from the baseplate rack.\u003c\/li\u003e\n\u003cli\u003eInsert the IC693PWR322 into the left-most slot of the Series 90-30 baseplate rack, ensuring complete engagement with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eSecure the top and bottom mounting screws to ground the module housing against the baseplate chassis ground.\u003c\/li\u003e\n\u003cli\u003eWire input power leads (24\/48 VDC nominal) to the designated screw terminals using appropriate copper conductor gauges.\u003c\/li\u003e\n\u003cli\u003eRoute primary DC input power cables away from low-voltage communication and analog input wiring to prevent noise coupling.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43737902317658,"sku":"IC693PWR322","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693PWR322.png?v=1785132725","url":"https:\/\/www.spareoil.com\/es\/products\/ge-fanuc-ic693pwr322-series-90-30-power-supply-module","provider":"SpareOil Automation","version":"1.0","type":"link"}