{"product_id":"ge-fanuc-ic693tcm302-series-90-30-temperature-control-module","title":"GE Fanuc IC693TCM302 Series 90-30 Temperature Control Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693TCM302\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693TCM302\u003c\/strong\u003e Temperature Control Module, operates as a dedicated hardware component for temperature monitoring and loop control within GE Fanuc Series 90-30 PLC systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693TCM302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 lbs (0.11 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot Series 90-30 module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA at 5 VDC (internal backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 thermocouple inputs \/ 8 control outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 36 VDC (2.5 A inrush)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per output channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Threshold Current\u003c\/td\u003e\n\u003ctd\u003e700 mA typical at 2 ms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Thermocouple Impedance\u003c\/td\u003e\n\u003ctd\u003e30 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eAutomatic mode, Manual mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003e12 status LEDs for channel state and fault diagnosis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC693TCM302 processes thermocouple sensor inputs and directly drives digital control outputs while executing temperature loop algorithms locally on the module. High-speed data exchange with the central processing unit is maintained over the Series 90-30 backplane bus without burdening main ladder logic execution. Dedicated channel diagnostics continuously evaluate loop continuity to detect open-circuit and reverse-polarity faults, updating status registers across the backplane in real time while maintaining strict firmware flash compatibility across Series 90-30 hardware revisions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power source is required to drive the output channels of the IC693TCM302?\u003c\/p\u003e\n\u003cp\u003eA: While internal logic draws 150 mA at 5 VDC from the Series 90-30 backplane, the field control outputs require an external 18 to 36 VDC power supply to provide output driving voltage.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module indicate hardware or sensor connection faults?\u003c\/p\u003e\n\u003cp\u003eA: The front panel includes 12 diagnostic LED indicators that report real-time channel status and fault conditions, including open-circuit thermocouples and reverse-polarity wiring connections.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum allowable thermocouple loop impedance for the input channels?\u003c\/p\u003e\n\u003cp\u003eA: Input channels support a maximum thermocouple wiring loop impedance of 30 Ohms to ensure measurement accuracy across the conversion circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRemove power from the Series 90-30 backplane and field power supplies before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the IC693TCM302 module housing with the target rack slot, engaging the bottom hook into the baseplate before snapping the top clip firmly into place.\u003c\/li\u003e\n\u003cli\u003eWire thermocouple lead extension pairs to the input terminal block, observing correct wire polarity and maintaining total loop resistance below 30 Ohms.\u003c\/li\u003e\n\u003cli\u003eRoute low-level thermocouple signal lines in separate, shielded conduits away from high-voltage AC lines and motor wiring to eliminate noise coupling.\u003c\/li\u003e\n\u003cli\u003eConnect external 24 VDC loop power to the designated supply terminals to power the 8 control outputs, ensuring proper circuit fusing to handle potential inrush current.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43778185887834,"sku":"IC693TCM302","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693TCM302.png?v=1785727953","url":"https:\/\/www.spareoil.com\/es\/products\/ge-fanuc-ic693tcm302-series-90-30-temperature-control-module","provider":"SpareOil Automation","version":"1.0","type":"link"}