{"product_id":"ge-fanuc-ic694alg222-pacsystems-rx3i-analog-input-module","title":"GE Fanuc IC694ALG222 PACSystems RX3i Analog Input Module","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694ALG222\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC694ALG222\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for analog voltage signal processing within PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694ALG222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.69 lbs (0.31 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e112 mA at 5 VDC backplane and 41 mA at 24 VDC user supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended or 8 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC (unipolar), -10 to +10 VDC (bipolar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bit (2.5 mV\/count at 0-10 V; 5.0 mV\/count at -10 to +10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e6 ms for 16 single-ended channels; 3 ms for 8 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25% at 25 deg C; +\/-0.5% full scale over operating temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Response\u003c\/td\u003e\n\u003ctd\u003e200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute (field to backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd\u003e20-screw terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC694ALG222 module enhances backplane bus communication velocity across PACSystems RX3i backplane racks by transferring digitized 12-bit voltage readings directly into the host CPU table within execution scan cycles as fast as 3 ms for differential configurations. Scalable I\/O density scaling allows flexible wiring layouts for up to 16 single-ended or 8 differential voltage channels on a single 20-screw terminal block. Firmware flash compatibility ensures uniform register allocation and automatic scanning across unipolar and bipolar signal boundaries. Optical isolation of 1500 VAC protects internal backplane logic from external ground loops and transient voltage disturbances.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What backplane and user power supplies are required for the IC694ALG222?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 112 mA from the +5 VDC backplane supply bus and 41 mA from an isolated +24 VDC external user supply.\u003c\/p\u003e\n\u003cp\u003eQ: How do the channel scan update rates vary between wiring configurations?\u003c\/p\u003e\n\u003cp\u003eA: All 8 differential input channels complete a full update scan in 3 ms, whereas all 16 single-ended channels require 6 ms for a complete update cycle.\u003c\/p\u003e\n\u003cp\u003eQ: What is the digital step resolution for the supported input voltage ranges?\u003c\/p\u003e\n\u003cp\u003eA: The 12-bit resolution yields 2.5 mV per count (1 LSB) for the 0 to 10 VDC unipolar range and 5.0 mV per count (1 LSB) for the -10 to +10 VDC bipolar range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect backplane system power and de-energize external 24 VDC loops before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the baseplate slot and push firmly until the rear connector latches into the RX3i backplane bus.\u003c\/li\u003e\n\u003cli\u003eFasten the top and bottom mounting screws to secure mechanical grounding and lock the module against chassis vibration.\u003c\/li\u003e\n\u003cli\u003eConnect signal leads to the 20-screw terminal block according to either single-ended (16 channels) or differential (8 channels) terminal configurations.\u003c\/li\u003e\n\u003cli\u003eRoute low-voltage analog wiring in dedicated raceways separated from AC power lines, grounding cable shields at a single chassis ground point.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43737672024154,"sku":"IC694ALG222","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694ALG222.png?v=1785132555","url":"https:\/\/www.spareoil.com\/es\/products\/ge-fanuc-ic694alg222-pacsystems-rx3i-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}