{"product_id":"ge-fanuc-ic694mdl655-pacsystems-rx3i-discrete-input-module","title":"GE Fanuc IC694MDL655 PACSystems RX3i Discrete Input Module","description":"\u003cp\u003eConfigured for receiving discrete binary field signals in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC694MDL655\u003c\/strong\u003e (\u003cstrong\u003eIC694MDL655\u003c\/strong\u003e Discrete Input Module) provides direct physical\/electrical execution. This high-density module features 32 distinct input channels divided into four isolated groups of eight, allowing interface capabilities with proximity sensors, limit switches, and pushbuttons.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC694MDL655\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.26 kg (0.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm x 30 mm x 115 mm (Standard single-slot width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195 mA maximum @ 5 VDC (backplane), 224 mA typical @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 (4 groups of 8 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-state Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 to 30.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-state Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-state Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-state Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time (On\/Off)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute (Backplane to Frame Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGroup-to-Group Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 VAC continuous; 500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo male 24-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling \u0026amp; Logic Configuration\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL655 provides high-density I\/O density scaling by packing 32 discrete channels into a single-slot module width. The circuitry supports both positive and negative logic (sink or source configurations). Wiring configuration is established per group; positive logic requires the positive field conductor connected directly to the input channel with the negative terminal routed to the common, while negative logic reverses this orientation. Isolation boundaries are placed between the four separate input groups to permit independent wiring configurations under varying voltage potentials.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can different input groups on the IC694MDL655 operate with different logic types simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. Because electrical isolation is maintained between the four groups of eight channels, you can wire one group for positive logic (sinking) and another group for negative logic (sourcing) on the same physical module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum recommended field wiring distance for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The maximum cable length for field devices wired to the IC694MDL655 must not exceed 30 meters to limit signal degradation and shield the inputs from electromagnetic noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indication is provided for individual input channel states?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module faceplate features 32 green LED indicators corresponding to each channel. An active LED signifies that the respective input channel is receiving an on-state voltage of 11.5 to 30.0 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Positioning:\u003c\/strong\u003e Turn off the PACSystems RX3i baseplate power prior to insertion. Insert the module into any available I\/O slot on the local rack or a distributed baseplate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Termination:\u003c\/strong\u003e Secure the field wiring to the two front-facing 24-pin male connectors. Ensure the terminal screws are torqued to prevent loose physical connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Routing:\u003c\/strong\u003e Run input sensor wiring in dedicated conduits separate from high-voltage AC motor power lines to mitigate cross-talk and transient voltage spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e When powering the field side from an external 24 VDC supply, ensure the supply output does not exceed 30 VDC continuous.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43667989856346,"sku":"IC694MDL655","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694MDL655.jpg?v=1784255404","url":"https:\/\/www.spareoil.com\/es\/products\/ge-fanuc-ic694mdl655-pacsystems-rx3i-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}