{"product_id":"ge-fanuc-ic695acc412-rx3i-pacsystem-cap-pack-module","title":"GE Fanuc IC695ACC412 RX3i PacSystem Cap Pack Module","description":"\u003cp\u003eConfigured for temporary hold-up power generation in PACSystems RX3i networks, the \u003cstrong\u003eGE Fanuc IC695ACC412\u003c\/strong\u003e (\u003cstrong\u003eIC695ACC412\u003c\/strong\u003e Cap Pack Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ACC412\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.80 kg (15.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEnclosure compliant with NEMA\/UL Type 1 standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustry standard 0 to 60 deg C (ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive energy storage device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Execution\u003c\/td\u003e\n\u003ctd\u003eTemporary holdup voltage to preserve volatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Interface\u003c\/td\u003e\n\u003ctd\u003e1 green STAT LED indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eIntegrated 1 meter controller link cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Mounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail assembly or panel top surface placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003ePollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe device functions within high-availability topologies alongside specialized CPU energy packs, maintaining continuous hardware operations across Profinet \/ EtherNet\/IP deterministic networks during localized voltage dips. It feeds power directly into the processing unit during input dropouts, ensuring backplane bus communication velocity remains stable long enough to save data parameters. This targeted retention mechanism isolates internal tracking structures from runtime data collapse during extensive I\/O density scaling routines, guaranteeing that firmware flash compatibility blocks are preserved until safely committed to non-volatile registers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What operational status is verified by the single green STAT LED indicator?\u003c\/p\u003e\n\u003cp\u003eA: The green STAT LED monitors the baseline charge state and hardware integrity of the internal capacitor banks. A solid illumination confirms the capacitance matrix is pressurized to the correct target threshold and is ready to deliver holding current.\u003c\/p\u003e\n\u003cp\u003eQ: Can this hardware assembly be installed directly adjacent to high-heat dissipation modules?\u003c\/p\u003e\n\u003cp\u003eA: No. To prevent thermal degradation of the internal storage components, the unit requires a strict minimum physical clearance of 25 mm (1 inch) on all sides to allow proper convection and heat dissipation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eTerminate all power feeds going to the RX3i chassis frame prior to mounting or handling the external capacitance device.\u003c\/li\u003e\n\u003cli\u003eFix the unit onto an EN50022 compliant DIN rail, or position it directly at the designated bottom base section of the master energy pack assembly.\u003c\/li\u003e\n\u003cli\u003eVerify that the 1-meter controller cable is securely plugged into the matching port interface on the host CPU or energy pack module.\u003c\/li\u003e\n\u003cli\u003eMaintain a clean enclosure perimeter matching the Pollution Degree 2 rating, ensuring no conductive airborne particulates enter the IP20 vent openings.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43627090870362,"sku":"IC695ACC412","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC695ACC402_ecad1e52-612d-4594-bb5d-13218673ede4.png?v=1783653612","url":"https:\/\/www.spareoil.com\/es\/products\/ge-fanuc-ic695acc412-rx3i-pacsystem-cap-pack-module","provider":"SpareOil Automation","version":"1.0","type":"link"}