{"product_id":"ge-ic220alg320-versapoint-analog-output-module","title":"GE IC220ALG320 VersaPoint Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC220ALG320\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC220ALG320\u003c\/strong\u003e VersaPoint Analog Output Module, operates as a dedicated hardware component for single-channel analog current and voltage signal generation within GE VersaPoint I\/O control systems. The unit executes digital-to-analog signal conversion with 16-bit resolution across configurable ranges including 0 to 20 mA, 4 to 20 mA, and 0 VDC to 10 VDC, interfacing directly to 2-wire field actuators via an IC220TBK203 terminal block.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC220ALG320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 lbs (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaPoint module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via VersaPoint local bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, 0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Interface\u003c\/td\u003e\n\u003ctd\u003e2-wire connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints\u003c\/td\u003e\n\u003ctd\u003e8 point base integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Terminal Block\u003c\/td\u003e\n\u003ctd\u003eIC220TBK203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module establishes direct serial connection across the VersaPoint local bus backplane, transmitting high-resolution 16-bit output directives with minimal propagation latency. Hardware configuration data and channel scaling parameters reside in non-volatile module memory, enabling immediate output state resolution without burdening central processor execution cycles. The architecture maintains backplane signal integrity during continuous cyclic updates across industrial Ethernet or controller-level deterministic network interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IC220TBK203 terminal block required for field signal termination?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module requires the IC220TBK203 terminal block base to establish proper physical electrical connections for 2-wire field output loops.\u003c\/p\u003e\n\u003cp\u003eQ: What range formats are supported for the single analog output channel?\u003c\/p\u003e\n\u003cp\u003eA: The channel can be software-configured to output standard analog ranges of 0 to 20 mA, 4 to 20 mA, or 0 VDC to 10 VDC at 16-bit conversion resolution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the module onto the DIN-rail assembly alongside adjacent VersaPoint I\/O blocks, ensuring firm mechanical engagement with the backplane bus connectors.\u003c\/li\u003e\n\u003cli\u003eInstall the required IC220TBK203 terminal block onto the front interface of the module prior to wiring.\u003c\/li\u003e\n\u003cli\u003eConnect 2-wire analog field devices using shielded twisted-pair cabling to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround the cable shielding at a single entry point on the cabinet ground rail in accordance with standard industrial wiring practices.\u003c\/li\u003e\n\u003cli\u003eConfirm supply voltage stability across the local bus before energizing the control system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796878032986,"sku":"IC220ALG320","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC220ALG320.jpg?v=1786090682","url":"https:\/\/www.spareoil.com\/es\/products\/ge-ic220alg320-versapoint-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}