{"product_id":"ge-ic698cpe020-rx7i-pacsystem-central-processing-module","title":"GE IC698CPE020 RX7i PACsystem Central Processing Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC698CPE020\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC698CPE020\u003c\/strong\u003e CPU Processor utilized to execute real-time control logic and user program actuation across PACSystem RX7i platforms. The rack-mounted processor acts as the primary controller node over the VME64 backplane, coordinating signal execution and routing digitized data across physical I\/O grids.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC698CPE020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMulti-slot rack module profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC: 4.5 A nominal (3.2 A baseline draw); +12 VDC: 0.042 A nominal; -12 VDC: 0.008 A nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd\u003ePentium III (700 MHz clock velocity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e10 MB RAM (User Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Memory\u003c\/td\u003e\n\u003ctd\u003e10 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e32 Kbits (%I and %Q)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e32 Kwords (%AI and %AQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Program Blocks\u003c\/td\u003e\n\u003ctd\u003e512 blocks (Maximum block size: 128 KB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connectivity\u003c\/td\u003e\n\u003ctd\u003e2x 10\/100 Mbps auto-sensing switched ports (Single IP mapping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e3x isolated ports (1x RS-232, 1x RS-485, 1x RS-232 Station Manager)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Speed\u003c\/td\u003e\n\u003ctd\u003e0.14 ms per 1000 Boolean contacts\/coils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe IC698CPE020 is engineered around a high-speed VME64 architecture that maintains fast data throughput and prevents localized register bottlenecking during comprehensive I\/O density scaling routines. Network communication integrates directly into Profinet \/ EtherNet\/IP deterministic networks via integrated Modbus TCP, EGD, and SRTP protocol channel stacks. Firmware flash compatibility ensures unified processing blocks for floating-point calculations and multi-language compiling, enabling seamless execution of concurrent runtime instructions without clock jitter.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane location constraints when installing this processor into an RX7i rack?\u003c\/p\u003e\n\u003cp\u003eA: The IC698CPE020 must be permanently keyed and installed into Slot 1 of the primary RX7i master chassis to properly govern the VME64 parallel bus allocation and line arbitration vectors.\u003c\/p\u003e\n\u003cp\u003eQ: How are network time protocols and media redundancy managed across the integrated dual Ethernet ports?\u003c\/p\u003e\n\u003cp\u003eA: The dual embedded interfaces act as switched ports under a single IP address assignment. Media redundancy is executed over LAN 2 pathways, while firmware releases 5.0 or later enable native SNTP network synchronization routines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Thermal Mitigation:\u003c\/strong\u003e Ensure that the rack enclosure maintains clear ventilation channels. The 700 MHz Pentium III architecture requires stable convection flow to remain within the 0 to 60 deg C operating baseline under maximum load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Diagnostic Isolation:\u003c\/strong\u003e When using the dedicated RS-232 Station Manager port for system queries, execute shield continuity termination to avoid high-frequency noise injection into the neighboring CPU logic circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware and Configuration Matching:\u003c\/strong\u003e Utilize Proficy Machine Edition Logic Developer PLC software version 4.0 or newer to define the memory partitioning and download application logic blocks securely to the 10 MB RAM partition.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43624485847130,"sku":"IC698CPE020","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC698CPE020.png?v=1783587713","url":"https:\/\/www.spareoil.com\/es\/products\/ge-ic698cpe020-rx7i-pacsystem-central-processing-module","provider":"SpareOil Automation","version":"1.0","type":"link"}