{"product_id":"hima-22100-planar4-safety-series-datasheet-technical-manual","title":"HIMA 22100 Planar4 Safety Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eHIMA 22100 Planar4 Safety Series\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal capturing in Safety Instrumented Systems (SIS), the \u003cstrong\u003eHIMA 22100\u003c\/strong\u003e (\u003cstrong\u003e22100\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e22100 (also cataloged as 22 100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e72 x 144 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePotential-free, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in self-test, short-circuit and open-circuit detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508), PLe (EN ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, TUV approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh Reliability Safety Control (SIS)\u003c\/h3\u003e\n\u003cp\u003eThe module architecture meets SIL 3 certification and PLe thresholds through integrated hardware diagnostic blocks that continuously verify inner logic path continuity. The internal system execution relies on a triple modular redundancy (TMR) 2oo3 architecture array to perform deterministic input validation voting loops. Continuous galvanic isolation separates the potential-free input stages from internal processing nodes, suppressing common-mode transients and ensuring deterministic fail-safe state execution within the safety loop during external field wiring faults.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 22100 module process input state changes during a localized short-circuit condition?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostic routines monitor loop impedance dynamically. Upon detecting an external short-circuit, the module registers a fault code on the system bus while forcing the affected channel log into its pre-configured fail-safe state.\u003c\/p\u003e\n\u003cp\u003eQ: Is this hardware component rated for hot-swapping inside a live Planar4 subrack assembly?\u003c\/p\u003e\n\u003cp\u003eA: Active module insertion and extraction are supported under powered backplane conditions, provided that subrack ground reference continuity is locked via the integrated retention mechanisms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module onto standard DIN-rail tracks or directly onto the structural backplane plate inside an enclosure maintaining a minimum index rating of IP54. Route all low-voltage field instrument cables through dedicated wireways, enforcing physical separation from adjacent parallel AC power lines or high-capacity motor feed circuits. Terminate the instrumentation screen layers exclusively at a single connection point on the main safety ground busbar to mitigate circulating ground loops. Maintain adequate clearance envelopes above and below the IP20 chassis to facilitate non-restricted vertical thermal dissipation.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43484423192666,"sku":"22100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/291._c4b9a105-3669-473d-b0ee-b42f0e06df3e.jpg?v=1781230791","url":"https:\/\/www.spareoil.com\/es\/products\/hima-22100-planar4-safety-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}