{"product_id":"honeywell-51304516-250-mc-pstx03-smart-transmitter-interface-multivariable","title":"Honeywell 51304516-250 MC-PSTX03 Smart Transmitter Interface Multivariable Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell 51304516-250 is a high-performance MC-PSTX03 Smart Transmitter Interface Multivariable (STIM) module, engineered to serve as a robust communication gateway between intelligent field transmitters and Honeywell distributed control systems. This processor assembly is designed to handle up to 16 input channels, facilitating the integration of multivariable transmitter data into advanced process control loops. By enabling the acquisition of both primary process variables and diagnostic information, the module enhances controller-level visibility and diagnostic accuracy in demanding industrial environments, including petrochemical, refinery, and power generation facilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 16 smart transmitter input channels for high-density signal processing.\u003c\/li\u003e\n\u003cli\u003eCE-compliant architecture featuring advanced electromagnetic compatibility (EMC) protections.\u003c\/li\u003e\n\u003cli\u003eEnhanced signal integrity through filtered IOP backpanel connectors.\u003c\/li\u003e\n\u003cli\u003eImproved shielding continuity via dedicated IOP grounding panels.\u003c\/li\u003e\n\u003cli\u003eRear backpanel shield structure to minimize interference in electrically noisy zones.\u003c\/li\u003e\n\u003cli\u003eConformal coated circuitry to provide superior resistance against humidity and airborne industrial contaminants.\u003c\/li\u003e\n\u003cli\u003eOptimized for deterministic communication and long-term operational stability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-PSTX03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304516-250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSmart Transmitter Interface Multivariable (STIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE Compliant (Enhanced EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eFiltered IOP connectors, grounding panels, rear shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cp\u003eTo ensure optimal performance and system longevity, observe the following installation protocols:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system backplane is powered down before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is correctly seated within the designated slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUtilize the integrated grounding panels to maintain shielding continuity; ensure the rear shield is correctly installed to meet EMC requirements.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage lines and sources of significant electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the module to ensure operating temperatures remain within the specified 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eHandle the unit using ESD-safe practices to prevent damage to internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the 51304516-250 module?\u003c\/strong\u003e\u003cbr\u003eThis module acts as a communication interface between smart field transmitters and the Honeywell control system, allowing for the processing of multivariable data and device diagnostics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat distinguishes the 51304516-250 from non-CE versions?\u003c\/strong\u003e\u003cbr\u003eThe 51304516-250 includes specific EMC enhancements, such as filtered IOP connectors, grounding panels, and a rear backpanel shield, which provide superior protection against electromagnetic interference in industrial settings.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this module suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes, the module features conformal coating, which provides protection against humidity and airborne contaminants typically found in industrial plant environments.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44012719439962,"sku":"51304516-250","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_00626069-f833-4aa1-8066-ab3b9335b62d.jpg?v=1788579256","url":"https:\/\/www.spareoil.com\/es\/products\/honeywell-51304516-250-mc-pstx03-smart-transmitter-interface-multivariable","provider":"SpareOil Automation","version":"1.0","type":"link"}