{"product_id":"honeywell-8c-taixa1-51307127-175-series-c-analog-input-module","title":"Honeywell 8C-TAIXA1 51307127-175 Series C Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell 8C-TAIXA1 (51307127-175) is a Series C HART-capable Analog Input Module engineered for seamless integration with Experion PKS and C300 control systems. This module serves as a high-precision interface between field instrumentation and the control layer, facilitating reliable signal acquisition for process automation. It is designed to mount directly onto an Input Output Termination Assembly (IOTA), streamlining cabinet wiring and reducing installation complexity in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Compatibility:\u003c\/strong\u003e Supports bidirectional digital communication with smart field devices for advanced diagnostics and remote configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Provides robust protection between field inputs and system electronics to mitigate ground loops and electrical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Continuous monitoring of signal status, including detection of open circuits, out-of-range conditions, and internal hardware faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Input Support:\u003c\/strong\u003e Versatile configuration for voltage, current, and temperature (RTD\/PT100) signal types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision:\u003c\/strong\u003e 16-bit resolution with 0.1 percent accuracy for critical process measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely deployed in mission-critical process industries, including oil and gas, power generation, and chemical processing. It is ideal for applications requiring high-density, reliable analog data acquisition and HART-enabled field device management within an Experion PKS architecture.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAIXA1 (51307127-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-10V, 0-20V, -5 to 5V, -10 to 10V, 4-20mA, PT100\/RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for direct mounting onto a Series C IOTA. Ensure the IOTA is securely fastened to a standard DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling:\u003c\/strong\u003e Always use a grounded wrist strap when handling the module to prevent electrostatic discharge damage to sensitive internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowering:\u003c\/strong\u003e Ensure the system is powered down before inserting or removing the module from the IOTA to prevent electrical arcing or configuration errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Ensure all field wiring is properly terminated at the IOTA. Use shielded twisted-pair cabling for analog signals to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain proper chassis grounding for the control cabinet to ensure the effectiveness of the module's galvanic isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat systems is the 8C-TAIXA1 compatible with?\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for use with the Honeywell Experion PKS and C300 controller platforms.\u003c\/p\u003e\u003ch3\u003eDoes this module support HART communication?\u003c\/h3\u003e\u003cp\u003eYes, the 8C-TAIXA1 is HART-capable, allowing for digital communication with smart field instruments for configuration and diagnostic data retrieval.\u003c\/p\u003e\u003ch3\u003eIs the module isolated?\u003c\/h3\u003e\u003cp\u003eYes, the module features channel-to-system galvanic isolation to protect against electrical noise and ground loops.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43965341827162,"sku":"8C-TAIXA1 51307127-175","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_98503ac5-92a2-4d48-b0a8-d5e5fcfa5aeb.jpg?v=1788112872","url":"https:\/\/www.spareoil.com\/es\/products\/honeywell-8c-taixa1-51307127-175-series-c-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}