{"product_id":"ic200pwr102-ge-fanuc-versamax-power-supply-module","title":"IC200PWR102 GE Fanuc VersaMax Power Supply Module","description":"\u003cp\u003eConfigured for backplane power distribution in VersaMax system platforms, the \u003cstrong\u003eGE Fanuc IC200PWR102\u003c\/strong\u003e (\u003cstrong\u003eIC200PWR102\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. The module converts AC mains input power into regulated 5 VDC and 3.3 VDC system buses to power attached CPUs, Network Interface Units (NIUs), and expansion I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PWR102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 lbs (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot VersaMax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e27 VA input power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Ranges\u003c\/td\u003e\n\u003ctd\u003e85-132 VAC (120 VAC nominal) \/ 176-264 VAC (240 VAC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Selection\u003c\/td\u003e\n\u003ctd\u003eJumper installed: 120 VAC; Jumper uninstalled: 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e5 VDC and 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e1.5 A total (up to 1.5 A @ 5 VDC, up to 1.0 A @ 3.3 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Protection\u003c\/td\u003e\n\u003ctd\u003eShort circuit and overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module executes direct power injection to the VersaMax system backplane, supplying up to 1.5 A combined current across the internal 5 VDC and 3.3 VDC buses. It operates either as the primary system power supply or as a supplemental booster supply mounted on a Power Supply Booster carrier. The unit maintains voltage regulation during momentary power losses with a 20 ms holdup time. Overload and short-circuit protection circuits continuously monitor output parameters to preserve backplane voltage integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the input voltage selection set between 120 VAC and 240 VAC on the IC200PWR102?\u003c\/p\u003e\n\u003cp\u003eA: A hardware terminal jumper on the unit controls the range: installing the jumper selects 120 VAC nominal (85-132 VAC), while omitting the jumper selects 240 VAC nominal (176-264 VAC).\u003c\/p\u003e\n\u003cp\u003eQ: What is the total maximum combined output current supplied to the backplane?\u003c\/p\u003e\n\u003cp\u003eA: The combined total output current across both 5 VDC and 3.3 VDC rails cannot exceed 1.5 A maximum.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC200PWR102 be used in expansion configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it can serve as a primary power module or as a secondary supply when attached to a VersaMax Power Supply Booster carrier.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that AC input power is de-energized before mounting or wiring the module carrier.\u003c\/li\u003e\n\u003cli\u003eVerify hardware jumper configuration prior to applying voltage: install the jumper for 120 VAC mains or remove it completely for 240 VAC operation.\u003c\/li\u003e\n\u003cli\u003eWire incoming AC line, neutral, and protective earth conductors securely to the designated terminals.\u003c\/li\u003e\n\u003cli\u003eMount the module chassis firmly onto the VersaMax base carrier until the retaining mechanisms snap into place.\u003c\/li\u003e\n\u003cli\u003eApply input power and verify proper backplane startup and status indicators.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796922728538,"sku":"IC200PWR102","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200PWR1022.png?v=1786092405","url":"https:\/\/www.spareoil.com\/es\/products\/ic200pwr102-ge-fanuc-versamax-power-supply-module","provider":"SpareOil Automation","version":"1.0","type":"link"}